Single-impulse panoramic photoacoustic computed tomography of small-animal whole-body dynamics at high spatiotemporal resolution
Open accessThe DOI matches its Crossref record; 45 of the 45 references it cites were found in a registry or an index.
Abstract
Imaging of small animals has played an indispensable role in preclinical research by providing high-dimensional physiological, pathological and phenotypic insights with clinical relevance. Yet, pure optical imaging suffers from either shallow penetration (up to ~1–2 mm) or a poor depth-to-resolution ratio (~3), and non-optical techniques for whole-body imaging of small animals lack either spatiotemporal resolution or functional contrast. Here, we demonstrate that stand-alone single-impulse panoramic photoacoustic computed tomography (SIP-PACT) mitigates these limitations by combining high spatiotemporal resolution (125 μm in-plane resolution, 50 μs per frame data acquisition and 50 Hz frame rate), deep penetration (48 mm cross-sectional width in vivo), anatomical, dynamical and functional contrasts, and full-view fidelity. Using SIP-PACT, we imaged in vivo whole-body dynamics of small animals in real time and obtained clear sub-organ anatomical and functional details. We tracked unlabelled circulating melanoma cells and imaged the vasculature and functional connectivity of whole rat brains. SIP-PACT holds great potential for both preclinical imaging and clinical translation. Single-impulse photoacoustic computed tomography can, at deep penetration and high resolution and contrast, image the whole-body dynamics of small animals in real time, and track injected cancer cells and image the vasculature of whole rat brains.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Siegel, R. L., Miller, K. D., & Jemal, A. (2016) · CA: A Cancer Journal for Clinicians · doi:10.3322/caac.21332 · Cited by 16,003
Computed Tomography — An Increasing Source of Radiation Exposure
Brenner, D. J., & Hall, E. J. (2007) · New England Journal of Medicine · doi:10.1056/nejmra072149 · Cited by 8,748
Brain magnetic resonance imaging with contrast dependent on blood oxygenation.
Ogawa, S., Lee, T. M., Kay, A. R., & Tank, D. W. (1990) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.87.24.9868 · Cited by 6,483
Photoacoustic tomography: In vivo imaging from organelles to organs
Wang, L. V., & Hu, S. (2012) · Science · doi:10.1126/science.1216210 · Cited by 4,331
Self-citationIsolation of rare circulating tumour cells in cancer patients by microchip technology
Nagrath, S., Sequist, L. V., Maheswaran, S., Bell, D. W., Irimia, D., Ulkus, L., Smith, M. R., Kwak, E. L., Digumarthy, S., Muzikansky, A., et al. (2007) · Nature · doi:10.1038/nature06385 · Cited by 3,559
Two-Frame Motion Estimation Based on Polynomial Expansion
Farnebäck, G. (2003) · Lecture Notes in Computer Science · doi:10.1007/3-540-45103-x_50 · Cited by 2,971
k-Wave: MATLAB toolbox for the simulation and reconstruction of photoacoustic wave fields
Treeby, B. E., & Cox, B. T. (2010) · Journal of Biomedical Optics · doi:10.1117/1.3360308 · Cited by 2,337
Going deeper than microscopy: the optical imaging frontier in biology
Ntziachristos, V. (2010) · Nature Methods · doi:10.1038/nmeth.1483 · Cited by 1,896
Multimodal fast optical interrogation of neural circuitry
Zhang, F., Wang, L.-P., Brauner, M., Liewald, J. F., Kay, K., Watzke, N., Wood, P. G., Bamberg, E., Nagel, G., Gottschalk, A., et al. (2007) · Nature · doi:10.1038/nature05744 · Cited by 1,738
Self-citationIn vivo three-photon microscopy of subcortical structures within an intact mouse brain
Horton, N. G., Wang, K., Kobat, D., Clark, C. G., Wise, F. W., Schaffer, C. B., & Xu, C. (2013) · Nature Photonics · doi:10.1038/nphoton.2012.336 · Cited by 1,505
Brain magnetic resonance imaging with contrast-dependent oxygenation
Ogawa, S. (1990) · Medical Entomology and Zoology · Cited by 1,367
Universal back-projection algorithm for photoacoustic computed tomography
Xu, M., & Wang, L. V. (2005) · Physical Review E · doi:10.1103/physreve.71.016706 · Cited by 1,243
Self-citationReal-time imaging reveals the single steps of brain metastasis formation.
Kienast, Y., von Baumgarten, L., Fuhrmann, M., Klinkert, W. E. F., Goldbrunner, R., Herms, J., & Winkler, F. (2010) · Nature Medicine · doi:10.1038/nm.2072 · Cited by 1,138
Wojnar, L. (1998) · Cited by 917
High-speed label-free functional photoacoustic microscopy of mouse brain in action
Yao, J., Wang, L., Yang, J.-M., Maslov, K. I., Wong, T. T. W., Li, L., Huang, C.-H., Zou, J., & Wang, L. V. (2015) · Nature Methods · doi:10.1038/nmeth.3336 · Cited by 716
Self-citationMultispectral opto-acoustic tomography of deep-seated fluorescent proteins in vivo
Razansky, D., Distel, M., Vinegoni, C., Ma, R., Perrimon, N., Köster, R. W., & Ntziachristos, V. (2009) · Nature Photonics · doi:10.1038/nphoton.2009.98 · Cited by 644
Behind the scenes of functional brain imaging: A historical and physiological perspective
Raichle, M. E. (1998) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.95.3.765 · Cited by 616
Noninvasive Pulse Wave Analysis for the Early Detection of Vascular Disease
Cohn, J. N., Finkelstein, S., McVeigh, G., Morgan, D., LeMay, L., Robinson, J., & Mock, J. (1995) · Hypertension · doi:10.1161/01.hyp.26.3.503 · Cited by 474
Deep in vivo photoacoustic imaging of mammalian tissues using a tyrosinase-based genetic reporter
Jathoul, A. P., Laufer, J., Ogunlade, O., Treeby, B., Cox, B., Zhang, E., Johnson, P., Pizzey, A. R., Philip, B., Marafioti, T., et al. (2015) · Nature Photonics · doi:10.1038/nphoton.2015.22 · Cited by 442
Volumetric real-time multispectral optoacoustic tomography of biomarkers
Razansky, D., Buehler, A., & Ntziachristos, V. (2011) · Nature Protocols · doi:10.1038/nprot.2011.351 · Cited by 309
Whole-body three-dimensional optoacoustic tomography system for small animals
Brecht, H.-P. F., Su, R., Fronheiser, M. P., Ermilov, S. A., Conjusteau, A., & Oraevsky, A. A. (2009) · Journal of Biomedical Optics · doi:10.1117/1.3259361 · Cited by 304
Yao, J., Kaberniuk, A. A., Li, L., Shcherbakova, D. M., Zhang, R., Wang, L., Li, G., Verkhusha, V. V., & Wang, L. V. (2016) · Nature Methods · doi:10.1038/nmeth.3656 · Cited by 271
Self-citationImaging of Functional Connectivity in the Mouse Brain
White, B. R., Bauer, A. Q., Snyder, A. Z., Schlaggar, B. L., Lee, J.-M., & Culver, J. P. (2011) · PLoS ONE · doi:10.1371/journal.pone.0016322 · Cited by 253
Quantitative cerebral blood flow with Optical Coherence Tomography
Srinivasan, V. J., Sakadžić, S., Gorczynska, I., Ruvinskaya, S., Wu, W., Fujimoto, J. G., & Boas, D. A. (2010) · Optics Express · doi:10.1364/oe.18.002477 · Cited by 248
Small-Animal Whole-Body Photoacoustic Tomography: A Review
Xia, J., & Wang, L. V. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2283507 · Cited by 242
Self-citationBaker, M. (2010) · Nature · doi:10.1038/463977a · Cited by 225
Jonckers, E., Van Audekerke, J., De Visscher, G., Van der Linden, A., & Verhoye, M. (2011) · PLoS ONE · doi:10.1371/journal.pone.0018876 · Cited by 216
Darne, C., Lu, Y., & Sevick-Muraca, E. M. (2014) · Physics in Medicine and Biology · doi:10.1088/0031-9155/59/1/r1 · Cited by 199
Cox, S. B., Woolsey, T. A., & Rovainen, C. M. (1993) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.1993.113 · Cited by 198
Osmanski, B.-F., Pezet, S., Ricobaraza, A., Lenkei, Z., & Tanter, M. (2014) · Nature Communications · doi:10.1038/ncomms6023 · Cited by 175
The endothelial response to oxygen deprivation: biology and clinical implications
Karimova, A., & Pinsky, D. J. (2001) · Intensive Care Medicine · doi:10.1007/s001340000790 · Cited by 159
Functional optoacoustic neuro-tomography for scalable whole-brain monitoring of calcium indicators
Deán‐Ben, X. L., Sela, G., Lauri, A., Kneipp, M., Ntziachristos, V., Westmeyer, G. G., Shoham, S., & Razansky, D. (2016) · Light Science & Applications · doi:10.1038/lsa.2016.201 · Cited by 149
Taruttis, A., Morscher, S., Burton, N. C., Razansky, D., & Ntziachristos, V. (2012) · PLoS ONE · doi:10.1371/journal.pone.0030491 · Cited by 144
Half-time image reconstruction in thermoacoustic tomography
Anastasio, M. A., Zhang, J., Pan, X., Zou, Y. S., Ku, G., & Wang, L. V. (2005) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2004.839682 · Cited by 138
Self-citationBiology: A Functional Approach
Roberts, M. B. V. (1971) · Cited by 125
Wearable 3-D Photoacoustic Tomography for Functional Brain Imaging in Behaving Rats
Tang, J., Coleman, J. E., Dai, X., & Jiang, H. (2016) · Scientific Reports · doi:10.1038/srep25470 · Cited by 96
Ultrasound Biomicroscopy in Small Animal Research: Applications in Molecular and Preclinical Imaging
Greco, A., Mancini, M., Gargiulo, S., Gramanzini, M., Claudio, P. P., Brunetti, A., & Salvatore, M. (2011) · BioMed Research International · doi:10.1155/2012/519238 · Cited by 91
Gottschalk, S., Fehm, T. F., Deán‐Ben, X. L., & Razansky, D. (2015) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.2014.249 · Cited by 84
Pulse Wave Velocity in End-Stage Renal Disease: Influence of Age and Body Dimensions
Kis, É., Cseprekál, O., Horváth, Z., Katona, G., Fekete, B., Hrapka, E., Szabó, A., Szabo, A. J., Fekete, A., & Reusz, G. (2008) · Pediatric Research · doi:10.1203/pdr.0b013e31815b47ff · Cited by 76
Xia, J., Danielli, A., Liu, Y., Wang, L., Maslov, K., & Wang, L. V. (2013) · Optics Letters · doi:10.1364/ol.38.002800 · Cited by 54
Self-citationWu, D., & Zhang, J. (2016) · NeuroImage · doi:10.1016/j.neuroimage.2015.10.051 · Cited by 48
The biology of human survival : life and death in extreme environments
Piantadosi, C. A. (2003) · Cited by 44
Unique patterns of brain metastasis produced by different human carcinomas in athymic nude mice
Schackert, G., Price, J. E., Bucana, C. D., & Fidler, I. J. (1989) · International Journal of Cancer · doi:10.1002/ijc.2910440524 · Cited by 40
Noninvasive Imaging for Supporting Basic Research
ZANZONICO, P. B. (2010) · Springer eBooks · doi:10.1007/978-3-642-12945-2_1 · Cited by 30
In vivo High Angular Resolution Diffusion-Weighted Imaging of Mouse Brain at 16.4 Tesla
Alomair, O. I., Brereton, I. M., Smith, M. T., Galloway, G. J., & Kurniawan, N. D. (2015) · PLoS ONE · doi:10.1371/journal.pone.0130133 · Cited by 26
Cited by
The emerging role of photoacoustic imaging in clinical oncology
Lin, L., & Wang, L. V. (2022) · Nature Reviews Clinical Oncology · doi:10.1038/s41571-022-00615-3 · Cited by 469
Self-citationWu, Z., Li, L., Yang, Y., Hu, P., Li, Y., Yang, S.-Y., Wang, L. V., & Gao, W. (2019) · Science Robotics · doi:10.1126/scirobotics.aax0613 · Cited by 466
Self-citationZhao, Z., Chen, C., Wu, W., Wang, F., Du, L., Zhang, X., Xiong, Y., He, X., Cai, Y., Kwok, R. T. K., et al. (2019) · Nature Communications · doi:10.1038/s41467-019-08722-z · Cited by 463
Single-breath-hold photoacoustic computed tomography of the breast
Lin, L., Hu, P., Shi, J., Appleton, C. M., Maslov, K., Li, L., Zhang, R., & Wang, L. V. (2018) · Nature Communications · doi:10.1038/s41467-018-04576-z · Cited by 454
Self-citationJiang, Y., Upputuri, P. K., Xie, C., Lyu, Y., Zhang, L., Xiong, Q., Pramanik, M., & Pu, K. (2017) · Nano Letters · doi:10.1021/acs.nanolett.7b02106 · Cited by 395
Metadata
- Authors
- Li, L., Zhu, L., Ma, C., Lin, L., Yao, J., Wang, L., Maslov, K., Zhang, R., Chen, W., Shi, J., & Wang, L. V.
- Venue
- Nature Biomedical Engineering
- Published
- 2017-05-10
- Volume
- 1
- Issue
- 5
- ISSN
- 2157-846X (ISSN-L)
- OpenAlex
- W2613485993
- Cited by
- 477
- References
- 45
- FWCI
- 20.25
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.