Robotic fluidic coupling and interrogation of multiple vascularized organ chips
Open accessThe DOI matches its Crossref record; 64 of the 64 references it cites were found in a registry or an index.
Abstract
Organ chips can recapitulate organ-level (patho)physiology, yet pharmacokinetic and pharmacodynamic analyses require multi-organ systems linked by vascular perfusion. Here, we describe an ‘interrogator’ that employs liquid-handling robotics, custom software and an integrated mobile microscope for the automated culture, perfusion, medium addition, fluidic linking, sample collection and in situ microscopy imaging of up to ten organ chips inside a standard tissue-culture incubator. The robotic interrogator maintained the viability and organ-specific functions of eight vascularized, two-channel organ chips (intestine, liver, kidney, heart, lung, skin, blood–brain barrier and brain) for 3 weeks in culture when intermittently fluidically coupled via a common blood substitute through their reservoirs of medium and endothelium-lined vascular channels. We used the robotic interrogator and a physiological multicompartmental reduced-order model of the experimental system to quantitatively predict the distribution of an inulin tracer perfused through the multi-organ human-body-on-chips. The automated culture system enables the imaging of cells in the organ chips and the repeated sampling of both the vascular and interstitial compartments without compromising fluidic coupling. A system employing liquid-handling robotics and an integrated mobile microscope enables the automated culture, sample collection and in situ microscopy imaging of up to ten fluidically coupled organ chips within a standard tissue-culture incubator.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Reconstituting organ-level lung functions on a chip
Huh, D., Matthews, B. D., Mammoto, A., Montoya-Zavala, M., Hsin, H. Y., & Ingber, D. E. (2010) · Science · doi:10.1126/science.1188302 · Cited by 4,250
Self-citationBhatia, S. N., & Ingber, D. E. (2014) · Nature Biotechnology · doi:10.1038/nbt.2989 · Cited by 3,305
Self-citationKim, H. J., Huh, D., Hamilton, G., & Ingber, D. E. (2012) · Lab on a Chip · doi:10.1039/c2lc40074j · Cited by 1,734
Self-citationDetermination of drug permeability and prediction of drug absorption in Caco-2 monolayers
Hubatsch, I., Ragnarsson, E. G. E., & Artursson, P. (2007) · Nature Protocols · doi:10.1038/nprot.2007.303 · Cited by 1,499
Liver sinusoidal endothelial cells: Physiology and role in liver diseases
Poisson, J., Lemoinne, S., Boulanger, C., Durand, F., Moreau, R., Valla, D., & Rautou, P.-E. (2017) · Journal of Hepatology · doi:10.1016/j.jhep.2016.07.009 · Cited by 1,047
Lost in translation: animal models and clinical trials in cancer treatment.
(2014) · Europe PMC (PubMed Central) · Cited by 1,033
Serine starvation induces stress and p53-dependent metabolic remodelling in cancer cells
Maddocks, O. D. K., Berkers, C. R., Mason, S. M., Zheng, L., Blyth, K., Gottlieb, E., & Vousden, K. H. (2013) · Nature · doi:10.1038/nature11743 · Cited by 1,007
A Human Disease Model of Drug Toxicity–Induced Pulmonary Edema in a Lung-on-a-Chip Microdevice
Huh, D., Leslie, D. C., Matthews, B. D., Fraser, J. P., Jurek, S., Hamilton, G. A., Thorneloe, K. S., McAlexander, M. A., & Ingber, D. E. (2012) · Science Translational Medicine · doi:10.1126/scitranslmed.3004249 · Cited by 993
Self-citationKim, H. J., Li, H., Collins, J. J., & Ingber, D. E. (2016) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1522193112 · Cited by 922
Self-citationMaschmeyer, I., Lorenz, A. K., Schimek, K., Hasenberg, T., Ramme, A. P., Hübner, J., Lindner, M., Drewell, C., Bauer, S., Thomas, A., et al. (2015) · Lab on a Chip · doi:10.1039/c5lc00392j · Cited by 861
Cited by
Human organs-on-chips for disease modelling, drug development and personalized medicine
Ingber, D. E. (2022) · Nature Reviews Genetics · doi:10.1038/s41576-022-00466-9 · Cited by 1,589
Self-citationA guide to the organ-on-a-chip
Leung, C. M., de Haan, P., Ronaldson-Bouchard, K., Kim, G.-A., Ko, J., Rho, H. S., Chen, Z., Habibovic, P., Jeon, N. L., Takayama, S., et al. (2022) · Nature Reviews Methods Primers · doi:10.1038/s43586-022-00118-6 · Cited by 1,116
Organs-on-chips: into the next decade
Low, L. A., Mummery, C., Berridge, B. R., Austin, C. P., & Tagle, D. A. (2021) · Nature Reviews Drug Discovery · doi:10.1038/s41573-020-0079-3 · Cited by 1,029
Organ-on-a-Chip: A New Paradigm for Drug Development
Ma, C., Peng, Y., Li, H., & Chen, W. (2021) · Trends in Pharmacological Sciences · doi:10.1016/j.tips.2020.11.009 · Cited by 576
A multi-organ chip with matured tissue niches linked by vascular flow
Ronaldson-Bouchard, K., Teles, D., Yeager, K., Tavakol, D. N., Zhao, Y., Chramiec, A., Tagore, S., Summers, M., Stylianos, S., Tamargo, M., et al. (2022) · Nature Biomedical Engineering · doi:10.1038/s41551-022-00882-6 · Cited by 512
Self-citationHerland, A., Maoz, B. M., Das, D., Somayaji, M. R., Prantil-Baun, R., Novak, R., Cronce, M., Huffstater, T., Jeanty, S. S. F., Ingram, M., et al. (2020) · Nature Biomedical Engineering · doi:10.1038/s41551-019-0498-9 · Cited by 500
Self-citationAutomated microfluidic platform for dynamic and combinatorial drug screening of tumor organoids
Schuster, B., Junkin, M., Kashaf, S. S., Romero-Calvo, I., Kirby, K., Matthews, J., Weber, C. R., Rzhetsky, A., White, K. P., & Tay, S. (2020) · Nature Communications · doi:10.1038/s41467-020-19058-4 · Cited by 424
Multiorgan-on-a-Chip: A Systemic Approach To Model and Decipher Inter-Organ Communication
Picollet-D’hahan, N., Zuchowska, A., Lemeunier, I., & Le Gac, S. (2021) · Trends in Biotechnology · doi:10.1016/j.tibtech.2020.11.014 · Cited by 379
The gut microbiome: an orchestrator of xenobiotic metabolism
Collins, S. L., & Patterson, A. D. (2020) · Acta Pharmaceutica Sinica B · doi:10.1016/j.apsb.2019.12.001 · Cited by 348
Human disease models in drug development
Loewa, A., Feng, J. J., & Hedtrich, S. (2023) · Nature Reviews Bioengineering · doi:10.1038/s44222-023-00063-3 · Cited by 331
Multi-lineage human iPSC-derived platforms for disease modeling and drug discovery
Sharma, A., Sances, S., Workman, M. J., & Svendsen, C. N. (2020) · Cell Stem Cell · doi:10.1016/j.stem.2020.02.011 · Cited by 296
“Recently, up to 10 independent microphysiological systems mimicking different tissue types have connected in this manner to develop a “physiome-on-a-chip” (Edington et al., 2018; Novak et al., 2020).”
BackgroundFoundations of gastrointestinal-based drug delivery and future developments
Chu, J. N., & Traverso, G. (2022) · Nature Reviews Gastroenterology & Hepatology · doi:10.1038/s41575-021-00539-w · Cited by 289
Ingber, D. E. (2020) · Advanced Science · doi:10.1002/advs.202002030 · Cited by 277
Self-citationOrgan-on-a-chip meets artificial intelligence in drug evaluation
Deng, S., Li, C., Cao, J., Cui, Z., Du, J., Fu, Z., Yang, H., & Chen, P. (2023) · Theranostics · doi:10.7150/thno.87266 · Cited by 260
Marx, U. (2020) · ALTEX · doi:10.14573/altex.2001241 · Cited by 218
“Ingber’s group at Wyss Institute to microfluidically link single-organ chips by an automated Interrogator instrument (PrantilBaun et al., 2018; Herland et al., in press; Novak et al., 2020) have been applied to mimic this homeostasis in vitro.”
MethodMicrofluidics for Drug Development: From Synthesis to Evaluation
Liu, Y., Sun, L., Zhang, H., Shang, L., & Zhao, Y. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.0c01289 · Cited by 202
Brown, T. D., Habibi, N., Wu, D., Lahann, J., & Mitragotri, S. (2020) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.0c00743 · Cited by 182
SARS-CoV-2 induced intestinal responses with a biomimetic human gut-on-chip
Guo, Y., Luo, R., Wang, Y., Deng, P., Song, T., Zhang, M., Wang, P., Zhang, X., Cui, K., Tao, T., et al. (2021) · Science Bulletin · doi:10.1016/j.scib.2020.11.015 · Cited by 164
Bone-on-a-chip: Microfluidic technologies and microphysiologic models of bone tissue
Mansoorifar, A., Gordon, R., Bergan, R. C., & Bertassoni, L. E. (2021) · Advanced Functional Materials · doi:10.1002/adfm.202006796 · Cited by 142
Papamichail, L., Koch, L. S., Veerman, D., Broersen, K., & van der Meer, A. D. (2025) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2025.1515340 · Cited by 120
In Vitro Strategies to Vascularize 3D Physiologically Relevant Models
Dellaquila, A., Le Bao, C., Letourneur, D., & Simon‐Yarza, T. (2021) · Advanced Science · doi:10.1002/advs.202100798 · Cited by 115
Towards in vitro models for reducing or replacing the use of animals in drug testing
Stresser, D. M., Kopec, A. K., Hewitt, P., Hardwick, R. N., Van Vleet, T. R., Mahalingaiah, P. K. S., O’Connell, D., Jenkins, G. J., David, R., Graham, J., et al. (2023) · Nature Biomedical Engineering · doi:10.1038/s41551-023-01154-7 · Cited by 94
Microfluidic high-throughput 3D cell culture
Ko, J., Park, D., Lee, J., Jung, S., Baek, K., Sung, K. E., Lee, J., & Jeon, N. L. (2024) · Nature Reviews Bioengineering · doi:10.1038/s44222-024-00163-8 · Cited by 88
“Automatic fluid delivery systems can be applied to distribute the flow from one organ model to another 27,28,162,163 ; for example, a cell culture module that generates cyclic stretching motion, media flow and replacement has been commercialized for lung and gut models 164 .”
InfluentialBioengineered skin organoids: from development to applications
Hong, Z.-X., Zhu, S.-T., Li, H., Luo, J.-Z., Yang, Y., An, Y., Wang, X., & Wang, K. (2023) · Military Medical Research · doi:10.1186/s40779-023-00475-7 · Cited by 77
“Integration with multi-organ chips can also be explored to establish connections and communication between skin organoids and other preformed organoids [14, 84, 86].”
BackgroundMethodAcademic User View: Organ-on-a-Chip Technology
Busek, M., Aizenshtadt, A., Amirola-Martinez, M., Delon, L., & Krauss, S. (2022) · Biosensors · doi:10.3390/bios12020126 · Cited by 37
“For drug screening, for instance, organ interactions are often important; therefore, most commercial platforms focus especially on this aspect either by implementing media recirculation to different organ compartments [31] or by using pipetting robots to couple single organ models with each other [32].”
BackgroundAlternative strategies in cardiac preclinical research and new clinical trial formats
Kreutzer, F. P., Meinecke, A., Schmidt, K., Fiedler, J., & Thum, T. (2022) · Cardiovascular Research · doi:10.1093/cvr/cvab075 · Cited by 36
“149,150 To no surprise, OOC technology was named one of the top 10 emerging technologies of 2016.”
BackgroundDeveloping Liver Microphysiological Systems for Biomedical Applications
Wang, J., Wu, X., Zhao, J., Ren, H., & Zhao, Y. (2024) · Advanced Healthcare Materials · doi:10.1002/adhm.202302217 · Cited by 27
Bentwich, I. (2023) · Drug Discovery Today · doi:10.1016/j.drudis.2023.103515 · Cited by 22
Metadata
- Authors
- Novak, R., Ingram, M., Marquez, S., Das, D., Delahanty, A., Herland, A., Maoz, B. M., Jeanty, S. S. F., Somayaji, M. R., Burt, M., Calamari, E., Chalkiadaki, A., Cho, A., Choe, Y., Chou, D. B., Cronce, M., Dauth, S., Divic, T., Fernandez-Alcon, J., Ferrante, T., Ferrier, J., FitzGerald, E. A., Fleming, R., Jalili-Firoozinezhad, S., Grevesse, T., Goss, J. A., Hamkins-Indik, T., Henry, O., Hinojosa, C., Huffstater, T., Jang, K.-J., Kujala, V., Leng, L., Mannix, R., Milton, Y., Nawroth, J., Nestor, B. A., Ng, C. F., O’Connor, B., Park, T.-E., Sanchez, H., Sliz, J., Sontheimer-Phelps, A., Swenor, B., Thompson, G., Touloumes, G. J., Tranchemontagne, Z., Wen, N., Yadid, M., Bahinski, A., Hamilton, G. A., Levner, D., Levy, O., Przekwas, A., Prantil-Baun, R., Parker, K. K., & Ingber, D. E.
- Venue
- Nature Biomedical Engineering
- Published
- 2020-01-27
- Volume
- 4
- Issue
- 4
- Pages
- 407-420
- ISSN
- 2157-846X (ISSN-L)
- OpenAlex
- W3002045056
- Cited by
- 427
- References
- 64
- FWCI
- 18.43
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.