Toward higher-performance bionic limbs for wider clinical use
Open accessThe DOI matches its Crossref record; 247 of the 251 references it cites were found in a registry or an index.
Abstract
Most prosthetic limbs can autonomously move with dexterity, yet they are not perceived by the user as belonging to their own body. Robotic limbs can convey information about the environment with higher precision than biological limbs, but their actual performance is substantially limited by current technologies for the interfacing of the robotic devices with the body and for transferring motor and sensory information bidirectionally between the prosthesis and the user. In this Perspective, we argue that direct skeletal attachment of bionic devices via osseointegration, the amplification of neural signals by targeted muscle innervation, improved prosthesis control via implanted muscle sensors and advanced algorithms, and the provision of sensory feedback by means of electrodes implanted in peripheral nerves, should all be leveraged towards the creation of a new generation of high-performance bionic limbs. These technologies have been clinically tested in humans, and alongside mechanical redesigns and adequate rehabilitation training should facilitate the wider clinical use of bionic limbs.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The text we found for this paper looks like another document, so the self-check wasn’t run.
Citations
Cites
A new strategy for multifunction myoelectric control
Hudgins, B., Parker, P., & Scott, R. N. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.204774 · Cited by 2,149 · cited 1×
“The natural patterns of muscle activation associated to specific movements are mapped by supervised learning to the corresponding tasks 78,79 .”
MethodBrain–machine interfaces: past, present and future
Lebedev, M. A., & Nicolelis, M. A. L. (2006) · Trends in Neurosciences · doi:10.1016/j.tins.2006.07.004 · Cited by 1,875
High-performance neuroprosthetic control by an individual with tetraplegia
Collinger, J. L., Wodlinger, B., Downey, J. E., Wang, W., Tyler-Kabara, E. C., Weber, D. J., McMorland, A. J., Velliste, M., Boninger, M. L., & Schwartz, A. B. (2013) · The Lancet · doi:10.1016/s0140-6736(12)61816-9 · Cited by 1,848 · cited 1×
“Implantable selective cortical electrodes can record from hundreds of cortical neurons, and this neural activity can then be associated with the online control of multiple degrees of freedom 132,133 .”
BackgroundUse of NeuroEyeCoach™ to Improve Eye Movement Efficacy in Patients with Homonymous Visual Field Loss
Sahraie, A., Smania, N., & Zihl, J. (2016) · BioMed Research International · doi:10.1155/2016/5186461 · Cited by 1,772
A robust, real-time control scheme for multifunction myoelectric control
Englehart, K., & Hudgins, B. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.813539 · Cited by 1,743
Upper limb prosthesis use and abandonment: A survey of the last 25 years
Biddiss, E. A., & Chau, T. T. (2007) · Prosthetics & Orthotics International · doi:10.1080/03093640600994581 · Cited by 1,111
Targeted Muscle Reinnervation for Real-time Myoelectric Control of Multifunction Artificial Arms
Kuiken, T. A. (2009) · JAMA · doi:10.1001/jama.2009.116 · Cited by 1,089 · cited 1×
“…in redirecting nerves that have lost their natural target muscles to other muscle tissues so as to biologically amplify the activity of the redirected nerve 115–119 — can provide a form of ‘bioscreen’ that displays, via muscle electrical signals, the neural activity of the transferred nerves.”
BackgroundSelf-citationRestoring natural sensory feedback in real-time bidirectional hand prostheses
Raspopovic, S., Capogrosso, M., Petrini, F. M., Bonizzato, M., Rigosa, J., Di Pino, G., Carpaneto, J., Controzzi, M., Boretius, T., Fernandez, E., et al. (2014) · Science Translational Medicine · doi:10.1126/scitranslmed.3006820 · Cited by 1,001 · cited 2×
“This class of implants can establish natural tactile sensations 42,194–196, Epidural stimulation of the spinal cord has been shown to evoke sensory precepts in the missing limbs of amputees 203 .”
BackgroundSelf-citationScheme, E., & Englehart, K. (2011) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2010.09.0177 · Cited by 969
Hands for dexterous manipulation and robust grasping: a difficult road toward simplicity
Bicchi, A. (2000) · IEEE Transactions on Robotics and Automation · doi:10.1109/70.897777 · Cited by 895
Research works printed but not linked: 1
- McDonnall, S., Hiatt, S., Crofts, B., Smith, C. & Merrill, D. Development of a wireless multichannel myoelectric implant for prosthesis control. In Proc. Myoelectric Control and Upper Limb Prosthesis Symposium (MEC 2017) 21 (2017).
Cited by
Manickam, P., Mariappan, S. A., Murugesan, S. M., Hansda, S., Kaushik, A., Shinde, R., & Thipperudraswamy, S. P. (2022) · Biosensors · doi:10.3390/bios12080562 · Cited by 637
“It should be diagnosed in the early stage and be monitored regularly.”
BackgroundFlexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics
Heng, W., Solomon, S., & Gao, W. (2022) · Advanced Materials · doi:10.1002/adma.202107902 · Cited by 609
Kong, L., Li, W., Zhang, T., Ma, H., Cao, Y., Wang, K., Zhou, Y., Shamim, A., Zheng, L., Wang, X., et al. (2024) · Advanced Materials · doi:10.1002/adma.202400333 · Cited by 227
Artificial intelligence meets medical robotics
Yip, M., Salcudean, S., Goldberg, K., Althoefer, K., Menciassi, A., Opfermann, J. D., Krieger, A., Swaminathan, K., Walsh, C. J., Huang, H. (., et al. (2023) · Science · doi:10.1126/science.adj3312 · Cited by 207
Self-citationWearable and Implantable Soft Robots
Yin, S., Yao, D. R., Song, Y., Heng, W., Ma, X., Han, H., & Gao, W. (2024) · Chemical Reviews · doi:10.1021/acs.chemrev.4c00513 · Cited by 173
Yang, S., Cheng, J., Shang, J., Hang, C., Qi, J., Zhong, L., Rao, Q., He, L., Liu, C., Ding, L., et al. (2023) · Nature Communications · doi:10.1038/s41467-023-42149-x · Cited by 172
“When the subject performed eccentric contraction, lowering the dumbbell back to rest position, there was lower muscle activity than in the concentric contraction, and the active zone moved back to the middle (Supplementary Movie 4).”
InfluentialOn human-in-the-loop optimization of human–robot interaction
Slade, P., Atkeson, C. G., Donelan, J. M., Houdijk, H., Ingraham, K. A., Kim, M., Kong, K., Poggensee, K. L., Riener, R., Steinert, M., et al. (2024) · Nature · doi:10.1038/s41586-024-07697-2 · Cited by 199
“To achieve these benefits, however, the robotic devices of the future will need to be far more effective at helping humans 2–4 .”
Marasco, P. D., Hebert, J. S., Sensinger, J. W., Beckler, D. T., Thumser, Z. C., Shehata, A. W., Williams, H. E., & Wilson, K. R. (2021) · Science Robotics · doi:10.1126/scirobotics.abf3368 · Cited by 156
Shaping high-performance wearable robots for human motor and sensory reconstruction and enhancement
Xia, H., Zhang, Y., Rajabi, N., Taleb, F., Yang, Q., Kragić, D., & Li, Z. (2024) · Nature Communications · doi:10.1038/s41467-024-46249-0 · Cited by 164
“Discomfort and problems with body fi tting are common causes of device rejection 112 .”
BackgroundEMG-driven control in lower limb prostheses: a topic-based systematic review
Cimolato, A., Driessen, J. J. M., Mattos, L. S., Momi, E. D., Laffranchi, M., & Michieli, L. D. (2022) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-022-01019-1 · Cited by 127
Bioelectronic medicine: Preclinical insights and clinical advances
Pavlov, V. A., & Tracey, K. J. (2022) · Neuron · doi:10.1016/j.neuron.2022.09.003 · Cited by 119
Active upper limb prostheses: a review on current state and upcoming breakthroughs
Marinelli, A., Boccardo, N., Tessari, F., Domenico, D. D., Caserta, G., Canepa, M., Gini, G. C., Barresi, G., Laffranchi, M., Michieli, L. D., et al. (2023) · Progress in Biomedical Engineering · doi:10.1088/2516-1091/acac57 · Cited by 132
“Besides EMG signals, IMU data have been also combined with NIRS (Zhao et al 2019) and MMG (Wilson and Vaidyanathan 2017, Woodward et al 2017).”
InfluentialMetaverse Wearables for Immersive Digital Healthcare: A Review
Kim, K., Yang, H., Lee, J.-H., & Lee, W. G. (2023) · Advanced Science · doi:10.1002/advs.202303234 · Cited by 128
Nowak, M., Vujaklija, I., Sturma, A., Castellini, C., & Farina, D. (2022) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2022.3194104 · Cited by 79
“At the same time, the induced controller instabilities lead to a lack of predictability which is paramount for establishing an engaging human-machine interface [19]– [21].”
BackgroundSelf-citationApplication of Min-Max Normalization on Subject-Invariant EMG Pattern Recognition
Islam, M. J., Ahmad, S., Haque, F., Reaz, M. B. I., Bhuiyan, M. A. S., & Islam, M. R. (2022) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2022.3220286 · Cited by 73
“Myoelectric pattern recognition is very helpful in identifying an amputee’s intended hand movements [45].”
BackgroundTopological Hydrogels for Long‐Term Brain Signal Monitoring, Neuromodulation, and Stroke Treatment
Shen, Z., Liang, Q., Chang, Q., Liu, Y., & Zhang, Q. M. (2023) · Advanced Materials · doi:10.1002/adma.202310365 · Cited by 78
Implantable hydrogels as pioneering materials for next-generation brain–computer interfaces
Khan, W. U., Shen, Z., Mugo, S. M., Wang, H., & Zhang, Q. M. (2025) · Chemical Society Reviews · doi:10.1039/d4cs01074d · Cited by 79
A myoelectric digital twin for fast and realistic modelling in deep learning
Maksymenko, K., Clarke, A. K., Guerra, I. M., Deslauriers‐Gauthier, S., & Farina, D. (2023) · Nature Communications · doi:10.1038/s41467-023-37238-w · Cited by 78
“For example, signals measured at the surface of the skin from skeletal muscle electrical activity, i.e. surface electromyography (sEMG), are used for the control of bionic limbs 1 .”
MethodSelf-citationThe extraction of neural strategies from the surface EMG: 2004–2024
Farina, D., Merletti, R., & Enoka, R. M. (2024) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00453.2024 · Cited by 91
Self-citationYang, J., Yang, K., An, X., Fan, Z., Yan, L., Yin, L., Long, Y., Pan, G., Liu, H., & Ni, Y. (2025) · Advanced Functional Materials · doi:10.1002/adfm.202416916 · Cited by 83
Novel Wearable HD-EMG Sensor With Shift-Robust Gesture Recognition Using Deep Learning
Chamberland, F., Buteau, É., Tam, S. M., Campbell, E., Mortazavi, A., Scheme, E., Fortier, P., Boukadoum, M., Campeau‐Lecours, A., & Gosselin, B. J. (2023) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2023.3314053 · Cited by 61
“In fact, decades-old myoelectric control schemes are still used in many commercial prostheses, with only one or two electrodes employed for single DoF activation [6], [7].”
BackgroundHong, Y., Zhao, Y., Berman, J., Chi, Y., Li, Y., Huang, H., & Yin, J. (2023) · Nature Communications · doi:10.1038/s41467-023-39741-6 · Cited by 59
“5e and Supplementary Movie 3), the kirigami gripper switches between the open and close states with the ETD ’ s movements operated by the EMG signals 49 – 51 recorded from the wrist extensor and fl exor, respectively.”
Self-citationA lightweight prosthetic hand with 19-DOF dexterity and human-level functions
Yang, H., Tao, Z., Yang, J., Ma, W., Zhang, H., Xu, M., Wu, M., Sun, S., Jin, H., Li, W., et al. (2025) · Nature Communications · doi:10.1038/s41467-025-56352-5 · Cited by 75
“Other limitations may include frequent recalibration before use and performance degradation due to physiological factors such as sweating and muscle fatigue 1,41,42 .”
Li, C., Wang, T., Zhou, S., Sun, Y., Xu, Z., Xu, S., Shu, S., Yi, Z., Jiang, B., Xie, S., et al. (2024) · Research · doi:10.34133/research.0366 · Cited by 54
Embodied Communication: How Robots and People Communicate Through Physical Interaction
Kalinowska, A., Pilarski, P. M., & Murphey, T. D. (2023) · Annual Review of Control Robotics and Autonomous Systems · doi:10.1146/annurev-control-070122-102501 · Cited by 60
3D Bioelectronics with a Remodellable Matrix for Long‐Term Tissue Integration and Recording
Boys, A. J., Carnicer‐Lombarte, A., Güemes, A., van Niekerk, D. C., Hilton, S., Barone, D. G., Proctor, C. M., Owens, R. M., & Malliaras, G. G. (2022) · Advanced Materials · doi:10.1002/adma.202207847 · Cited by 43
Continuous Semi-autonomous Prosthesis Control Using a Depth Sensor on the Hand
Castro, M. N., & Dosen, S. S. (2022) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2022.814973 · Cited by 51
Caillet, A. H., Avrillon, S., Kundu, A., Yu, T., Phillips, A., Modenese, L., & Farina, D. (2023) · eNeuro · doi:10.1523/eneuro.0064-23.2023 · Cited by 58
Self-citationFanciullacci, C., McKinney, Z., Monaco, V., Milandri, G. S., Davalli, A., Sacchetti, R., Laffranchi, M., Michieli, L. D., Baldoni, A., Mazzoni, A., et al. (2021) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-021-00944-x · Cited by 45
“Finally, to make such research relevant to ongoing advancements in neuroprosthesis technology, the relative benefits of various TFP design features and performance settings should also be investigated in the context of advanced neuromuscular integration approaches such as targeted muscle reinnervation and intramuscula…”
BackgroundChiappalone, M., Cota, V. R., Carè, M., Florio, M. D., Beaubois, R., Buccelli, S., Barban, F., Brofiga, M., Averna, A., Bonacini, F., et al. (2022) · Brain Sciences · doi:10.3390/brainsci12111578 · Cited by 48
A hierarchical sensorimotor control framework for human-in-the-loop robotic hands
Seminara, L., Dosen, S. S., Mastrogiovanni, F., Bianchi, M., Watt, S. J., Beckerle, P., Nanayakkara, T., Drewing, K., Moscatelli, A., Klatzky, R. L., et al. (2023) · Science Robotics · doi:10.1126/scirobotics.add5434 · Cited by 48
Ultrathin Soft Wearable Sensor Materials and Structures: A Review of Current Trends and Prospectives
Kim, J., Kang, D.-H., Kwak, M. S., Jung, G., Kim, J., Park, S., Ko, H., & Tsukruk, V. V. (2025) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.5c14329 · Cited by 57
Caillet, A. H., Phillips, A., Farina, D., & Modenese, L. (2022) · PLoS Computational Biology · doi:10.1371/journal.pcbi.1010556 · Cited by 42
Self-citationAbbass, Y., Saleh, M., Dosen, S. S., & Valle, M. (2021) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2021.3107723 · Cited by 44
The Latest Research Progress on Bionic Artificial Hands: A Systematic Review
Guo, K., Lu, J., Wu, Y., Hu, X., & Yang, H. (2024) · Micromachines · doi:10.3390/mi15070891 · Cited by 48
“Hand motion recognition controlled by EMG is also optimized by the algorithm, and the accuracy rate is as high as 98.4%, which provides a bright future for the prosthetic.”
MethodInfluentialNeural prosthesis control restores near-normative neuromechanics in standing postural control
Fleming, A., Liu, W., & Huang, H. (2023) · Science Robotics · doi:10.1126/scirobotics.adf5758 · Cited by 35
“Electro-myographic (EMG) signals recorded from the residual muscles have been widely used as a neural control source for prosthetic limbs ( 26 ), because EMG signals are amplified motor control signals and because amputees retain the ability to generate feedforward activations of their residual…”
BackgroundSelf-citationLaschowski, B., & McPhee, J. (2023) · Journal of Computational and Nonlinear Dynamics · doi:10.1115/1.4056919 · Cited by 39
Gherardini, M., Ianniciello, V., Masiero, F., Paggetti, F., D’Accolti, D., Frazia, E. L., Mani, O., Dalise, S., Dejanovic, K., Fragapane, N., et al. (2024) · Science Robotics · doi:10.1126/scirobotics.adp3260 · Cited by 50
Wearable robots for the real world need vision
Gionfrida, L., Kim, D., Scaramuzza, D., Farina, D., & Howe, R. D. (2024) · Science Robotics · doi:10.1126/scirobotics.adj8812 · Cited by 39
Self-citationBiomimetic versus arbitrary motor control strategies for bionic hand skill learning
Schone, H. R., Udeozor, M., Moninghoff, M., Rispoli, B., Vandersea, J., Lock, B. A., Hargrove, L. J., Makin, T. R., & Baker, C. I. (2024) · Nature Human Behaviour · doi:10.1038/s41562-023-01811-6 · Cited by 49
“It is a widely held assumption that control strategies designed to mimic the biological body might provide unique benefits to the user in terms of device learning, generalization, sense of embodiment and automaticity 4,7,10,20–27 .”
BackgroundSelf-citationEvolution, biomechanics, and neurobiology converge to explain selective finger motor control
Xu, J., Mawase, F., & Schieber, M. H. (2024) · Physiological Reviews · doi:10.1152/physrev.00030.2023 · Cited by 36
Ultrasound as a Neurorobotic Interface: A Review
Yang, X., Castellini, C., Farina, D., & Liu, H. (2024) · IEEE Transactions on Systems Man and Cybernetics Systems · doi:10.1109/tsmc.2024.3358960 · Cited by 33
“Implanted (invasive) neurorobotic interfaces provide a direct connection with human neural cells and achieve relatively high accuracy in motor intention detection [1]; however, the high level of invasiveness, with associated risks, limit their widespread application [2], [3].”
BackgroundSelf-citationBeaubois, R., Cheslet, J., Duenki, T., Venuto, G. D., Carè, M., Khoyratee, F., Chiappalone, M., Branchereau, P., Ikeuchi, Y., & Levi, T. (2024) · Nature Communications · doi:10.1038/s41467-024-48905-x · Cited by 40
“In this context, new therapeutic approaches and technologies are needed both to promote cell survival and regeneration of local circuits 4 and restore long distance communication between disconnected brain regions and circuits 5 .”
BackgroundHuang, H., Hargrove, L. J., Ortiz-Catalan, M., & Sensinger, J. W. (2024) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-110222-095816 · Cited by 42
Self-citationMoctar, S. M. S., Rida, I., & Boudaoud, S. (2024) · IRBM · doi:10.1016/j.irbm.2024.100866 · Cited by 45
In vivo microelectrode arrays for neuroscience
Williams, N. P., Vöröslakos, M., Shi, D., Pwint, M. Y., Lanzio, V., Mao, H., Zolotavin, P., Yoon, E., Stieglitz, T., Xie, C., et al. (2025) · Nature Reviews Methods Primers · doi:10.1038/s43586-025-00399-7 · Cited by 39
“There is still much work to be done optimizing MEA interfaces for the individuals who can benefit from them 208 .”
Self-citationToward the Development of User-Centered Neurointegrated Lower Limb Prostheses
Barberi, F., Anselmino, E., Mazzoni, A., Goldfarb, M. T., & Micera, S. (2023) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2023.3309328 · Cited by 32
“…the inclusion of subjects for osseointegration do not exist, typical exclusion criteria include diabetes, vascular diseases, immunosuppressed subjects, a body mass index above 25 kg/m 2 , and other situations that could lead to mechanical complications and insurgence of infections [25], [34], [35].”
BackgroundSelf-citationA comprehensive review of sEMG-IMU sensor fusion for upper limb movements pattern recognition
Zhang, H., Moctar, S. M. S., Boudaoud, S., & Rida, I. (2025) · Information Fusion · doi:10.1016/j.inffus.2025.103422 · Cited by 40
Recent Advances in Biomimetics for the Development of Bio-Inspired Prosthetic Limbs
Varaganti, P., & Seo, S. (2024) · Biomimetics · doi:10.3390/biomimetics9050273 · Cited by 29
“By delving into the intricate interplay between artificial devices and biological organisms, these advancements offer promising prospects for improving the quality of life for individuals with limb loss [5].”
InfluentialCaillet, A. H., Phillips, A., Farina, D., & Modenese, L. (2023) · PLoS Computational Biology · doi:10.1371/journal.pcbi.1011606 · Cited by 32
Self-citationThe MSC Prosthetic Hand: Rapid, Powerful, and Intuitive
Cho, Y., Lee, Y., Kim, P., Jeong, S., & Kim, K.-S. (2022) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2022.3140444 · Cited by 25
“3140444 experienced amputation [1]–[3].”
Dere, M. D., & Lee, B. (2023) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2023.3330289 · Cited by 32
“HD-sEMG has been investigated for virtual cursor control by decoding motor unit (MU) discharge timing [8], decoding muscle force [9], [10], gesture classification [11], [12], automatic muscle disease diagnoses [13], sEMG decomposition [14], and prosthetic device control [15].”
MethodAbbass, Y., Dosen, S. S., Seminara, L., & Valle, M. (2022) · Philosophical Transactions of the Royal Society A Mathematical Physical and Engineering Sciences · doi:10.1098/rsta.2021.0017 · Cited by 30
“All in all, this is an important step towards implementing a full high-bandwidth human machine interface that will allow a bidirectional connection between the subject and a machine (robotic system) for dexterous control and comprehensive feedback [31].”
BackgroundIntelligent Knee Prostheses: A Systematic Review of Control Strategies
Li, L., Wang, X., Meng, Q., Chen, C., Sun, J., & Yu, H. (2022) · Journal of Bionic Engineering · doi:10.1007/s42235-022-00169-1 · Cited by 24
“discuss the latest technologies in the field of bionic devices, with an outlook on the design, manufacture and testing of the next generation of clinical prosthetic systems, the starting point of the article being from a clinical perspective rather than a control strategy [22].”
BackgroundCapsi‐Morales, P., Piazza, C., Sjöberg, L., Catalano, M. G., Grioli, G., Bicchi, A., & Hermansson, L. (2023) · PLoS ONE · doi:10.1371/journal.pone.0289978 · Cited by 30
The SoftHand Pro platform: a flexible prosthesis with a user-centered approach
Capsi‐Morales, P., Piazza, C., Grioli, G., Bicchi, A., & Catalano, M. G. (2023) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-023-01130-x · Cited by 26
“They are an attractive alternative to traditional prostheses due to their high level of anthropomorphism and dexterity [4, 5].”
BackgroundGašparić, F., Jorgovanović, N., Höfer, C., Russold, M., Koppe, M., Stanišić, D., & Dosen, S. S. (2023) · IEEE Transactions on Haptics · doi:10.1109/toh.2023.3293545 · Cited by 23
“and exteroceptive information from the hand back to the user [13], [14].”
BackgroundNagaraja, V. H., Lopes, J. P., & Bergmann, J. (2022) · Prosthesis · doi:10.3390/prosthesis4030032 · Cited by 22
Automated calibration of somatosensory stimulation using reinforcement learning
Borda, L., Gozzi, N., Preatoni, G., Valle, G., & Raspopović, S. (2023) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-023-01246-0 · Cited by 22
Artificial referred sensation in upper and lower limb prosthesis users: a systematic review
Gonzalez, M. A., Bismuth, A., Lee, C., Chestek, C. A., & Gates, D. H. (2022) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac8c38 · Cited by 27
“The technologies that are currently being used to elicit sensation through electrical stimulation are well described and illustrated in [6, 13, 19, 27–29].”
Tanzarella, S., Iacono, M., Donati, E., Farina, D., & Bartolozzi, C. (2023) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2023.3295658 · Cited by 27
“…directly measure the activity of neurons (e.g., electroneuronography (ENG), electrocorticography (ECoG), Microelectrode arrays (MEAs)), while non-invasive measures (Electroencephalography (EEG), surface electromyography (sEMG), etc.) provide global information on neural activity [20], [39].”
BackgroundSelf-citationEddy, E., Campbell, E., Bateman, S., & Scheme, E. (2024) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2024.1463377 · Cited by 37
“…myoelectric prosthesis control has continued to evolve and mature, such as through the simultaneous control of degrees of freedom (Hahne et al., 2014; Smith et al., 2014) and through augmentations of the human body, including targeted muscle reinnervation and osseointegration (Farina et al., 2023).”
BackgroundGherardini, M., Masiero, F., Ianniciello, V., & Cipriani, C. (2023) · Current Opinion in Biomedical Engineering · doi:10.1016/j.cobme.2023.100460 · Cited by 24
Hill-type models of skeletal muscle and neuromuscular actuators: a systematic review
(2022) · doi:10.1101/2022.10.14.512218 · Cited by 19
Self-citationThe Future of Biohybrid Regenerative Bioelectronics
Carnicer‐Lombarte, A., Malliaras, G. G., & Barone, D. G. (2024) · Advanced Materials · doi:10.1002/adma.202408308 · Cited by 25
(2023) · doi:10.1101/2023.02.18.529050 · Cited by 18
Self-citationBidirectional bionic limbs: a perspective bridging technology and physiology
Pasluosta, C. F., Kiele, P., Čvančara, P., Micera, S., Aszmann, O. C., & Stieglitz, T. (2022) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac4bff · Cited by 19
“While these highly refined prostheses fail to completely restore function and sensory feedback, they perform extremely well in clinical testing [28] and home-use trials [29–32].”
BackgroundSelf-citationWearable High Voltage Compliant Current Stimulator for Restoring Sensory Feedback
Collu, R., Paolini, R., Bilotta, M., Demofonti, A., Cordella, F., Zollo, L., & Barbaro, M. (2023) · Micromachines · doi:10.3390/mi14040782 · Cited by 19
Transcutaneous Magnet Localizer for a Self-Contained Myokinetic Prosthetic Hand
Ianniciello, V., Gherardini, M., & Cipriani, C. (2023) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2023.3325910 · Cited by 21
“The myokinetic interface fits into a landscape of innovative surgical procedures and technologies aimed at restoring a more natural control in prosthetic limbs [8], [9], [10], [11].”
BackgroundGuo, Y., Sun, L., Zhong, W., Zhang, N., Zhao, Z., & Tian, W. (2024) · PubMed Central · doi:10.4103/1673-5374.380909 · Cited by 35
Estimating speed-accuracy trade-offs to evaluate and understand closed-loop prosthesis interfaces
Mamidanna, P., Dideriksen, J. L., & Dosen, S. S. (2022) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac8a78 · Cited by 15
“conceptual and implementational barriers [1, 28, 38].”
Interfacing Neuron-Motor Pathways with Stretchable and Biocompatible Electrode Arrays
Jiang, Z., Zhu, M. J., & Chen, X. (2024) · Accounts of Chemical Research · doi:10.1021/acs.accounts.4c00215 · Cited by 18
Flexible and stretchable implantable devices for peripheral neuromuscular electrophysiology
Li, H., Zhao, H., Song, K., Han, F., Liu, Z., & Tian, Q. (2024) · Nanoscale · doi:10.1039/d3nr05488h · Cited by 18
Zhou, Y., Xu, W., Ji, Y., Zhou, G., Wu, W., Chen, Z., Wang, B., Gui, X., & Li, X. (2023) · Applied Physics Reviews · doi:10.1063/5.0144956 · Cited by 18
Zhu, Z., Li, J., Boyd, W. J., Martinez-Luna, C., Dai, C., Wang, H., Wang, H., Huang, X., Farrell, T. R., & Clancy, E. A. (2022) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2022.3163149 · Cited by 16
“Traditionally, multi-DoF control is assumed to best be facilitated by selecting intuitive control strategies/phantom limb contractions [23], [66]–[68].”
BackgroundPeripheral neurostimulation for encoding artificial somatosensations
Valle, G. D. (2022) · European Journal of Neuroscience · doi:10.1111/ejn.15822 · Cited by 18
Mani, N., Ahnood, A., Peng, D., Tong, W., Booth, M. A., Jones, A., Murdoch, B. J., Tran, N. L., Houshyar, S., & Fox, K. E. (2021) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.1c07318 · Cited by 15
Creation of a biological sensorimotor interface for bionic reconstruction
Festin, C., Ortmayr, J., Maierhofer, U., Tereshenko, V., Blumer, R., Schmoll, M., Rojas, G. C., Luft, M., Laengle, G., Farina, D., et al. (2024) · Nature Communications · doi:10.1038/s41467-024-49580-8 · Cited by 18
“Therefore, the restoration of intuitive sensory feedback in bi-directional man-machine interfaces remains an unsolved challenge 12 .”
Self-citationEMG-based prediction of step direction for a better control of lower limb wearable devices
Anselmino, E., Mazzoni, A., & Micera, S. (2024) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2024.108305 · Cited by 15
Self-citationFei, G., Zhang, S., Li, Y., Peng, M., Tang, Z., Gu, X., Li, X., Zhang, K., Xie, J., Ni, Y., et al. (2025) · Materials Science and Engineering R Reports · doi:10.1016/j.mser.2025.100990 · Cited by 18
Substitutive proprioception feedback of a prosthetic wrist by electrotactile stimulation
Han, Y., Lu, Y., Zuo, Y., Song, H., Chou, C.-H., Xing, W., Li, X., Li, L., Niu, C. M., & Hou, W. (2023) · Frontiers in Neuroscience · doi:10.3389/fnins.2023.1135687 · Cited by 18
“, 2022), frequency (Farina et al., 2021; Graczyk et al., 2022), pulse width (Yang et al.”
BackgroundRossato, J., Hug, F., Tucker, K. J., Gibbs, C., Lacourpaille, L., Farina, D., & Avrillon, S. (2023) · eLife · doi:10.7554/elife.88670 · Cited by 16
“Real-time decoding is also essential for interfacing with external devices ( Farina et al., 2023 ) or virtual limbs ( Oliveira et al., 2024 ) when activity is present at the periphery of the nervous system.”
BackgroundSelf-citationYang, J., Shibata, K., Weber, D. J., & Erickson, Z. (2025) · npj Robotics · doi:10.1038/s44182-025-00018-3 · Cited by 35
“Bymappingintendedgesturestothemovementsofanassistive mobilemanipulator,ourworkdemonstratesacontrolapproachthatcould potentiallybene fi t individuals with paralysis one day.”
Excitation of natural spinal reflex loops in the sensory-motor control of hand prostheses
Alva, P. G. S., Boesendorfer, A., Aszmann, O. C., Ibáñez, J., & Farina, D. (2024) · Science Robotics · doi:10.1126/scirobotics.adl0085 · Cited by 18
Self-citationEngineered Graphene Material Improves the Performance of Intraneural Peripheral Nerve Electrodes
Rodríguez‐Meana, B., del Valle, J., Viana, D., Walston, S. T., Ria, N., Masvidal‐Codina, E., Garrido, J. A., & Navarro, X. (2024) · Advanced Science · doi:10.1002/advs.202308689 · Cited by 17
Ségas, E., Mick, S., Leconte, V., Dubois, O., Klotz, R., Cattaert, D., & de Rugy, A. (2023) · eLife · doi:10.7554/elife.87317 · Cited by 20
“…the nervous system ( Ortiz-Catalan et al., 2020 ; Ortiz-Catalan et al., 2014a ; D’Anna et al., 2019 ; Zollo et al., 2019 ; Salminger et al., 2019 ), and advanced signal processing to encode and decode sensorimotor signals ( Jezernik et al., 2001 ; Farina et al., 2023 ; Cracchiolo et al., 2020 ).”
BackgroundGašparić, F., Jorgovanović, N., Höfer, C., Russold, M., Koppe, M., Stanišić, D., & Dosen, S. S. (2023) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2023.3330502 · Cited by 18
“However, developing a feedback interface that is effective in realistic conditions of prosthesis use, when incidental feedback sources such as motor sound and visual observation are not blocked, is still an open challenge [24], [25].”
BackgroundGstoettner, C., Laengle, G., Harnoncourt, L., Sassu, P., & Aszmann, O. C. (2024) · Journal of Hand Surgery (European Volume) · doi:10.1177/17531934241227795 · Cited by 14
“However, the bottleneck to improving patient outcomes and satisfaction remains the man-machine interface (Farina and Aszmann, 2014; Farina et al., 2023).”
BackgroundSelf-citationLuo, Q., Niu, C. M., Chou, C.-H., Liang, W., Deng, X., Hao, M., & Lan, N. (2021) · Frontiers in Neuroscience · doi:10.3389/fnins.2021.783505 · Cited by 13
Castañeda, T. S., Connan, M., Capsi‐Morales, P., Beckerle, P., Castellini, C., & Piazza, C. (2024) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-024-01352-7 · Cited by 17
“As the clinical translation of neuroprostheses capable of restoring lost extremities progresses towards accessibility [5], the recognition of prosthetic embodiment as a crucial factor for evaluating psycho-social outcomes becomes increasingly evident [6, 7].”
BackgroundLi, L., Wang, X., Meng, Q., & Yu, H. (2023) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2023.3331273 · Cited by 14
“L OWER limb robotics such as exoskeletons and prostheses, can improve the mobility level and quality of life of individuals with disabilities [1], [2].”
BackgroundThe Next Frontier in Neuroprosthetics: Integration of Biomimetic Somatosensory Feedback
Tian, Y., Valle, G. D., Cederna, P. S., & Kemp, S. W. P. (2025) · Biomimetics · doi:10.3390/biomimetics10030130 · Cited by 18
Non-Invasive Stable Sensory Feedback for Closed-Loop Control of Hand Prosthesis
Zhang, J., Chou, C.-H., Wu, X., Pei, W., & Lan, N. (2022) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc48229.2022.9871682 · Cited by 11
Hinson, R. M., Berman, J., Lee, I., Filer, W. G., & Huang, H. (2023) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2023.3297448 · Cited by 13
“wherein, θ v irtual is the joint angle of the virtual hand upon successfully matching a target posture, θ physical is the corresponding joint angle of the subject’s physical hand upon successfully matching a target posture, and RoM is the joint’s range of motion [28].”
BackgroundMethodInfluentialSelf-citationHill-type models of skeletal muscle and neuromuscular actuators: a systematic review
Caillet, A., Phillips, A., Carty, C., Farina, D., & Modenese, L. (2024) · bioRxiv · doi:10.1109/rbme.2025.3593185 · Cited by 23
“…procedures [73], [74], [75] or optimizing rehabilitation [76], [77], [78], or for the design and control of prosthetics [79], [80], [81], [82], [83]; and (5) in sports-related applications, such as for optimizing performance [84], [85], [86] or predicting the effects of muscle fatigue on…”
Self-citationTereshenko, V., Dotzauer, D. C., Schmoll, M., Harnoncourt, L., Rojas, G. C., Gfrerer, L., Eberlin, K. R., Austen, W. G., Blumer, R., Farina, D., et al. (2024) · Science Advances · doi:10.1126/sciadv.adj3872 · Cited by 11
“For this purpose, it is preferrable to create a muscle interface with a high ratio of neural input (i.e., number of motor axons) to muscle volume ( 5 ).”
InfluentialSelf-citationKarimi, M., Yeganeh, N., Makarov, I. M., Sverrisson, A. Ö., Gunnarsson, K. F., Briem, K., Brynjólfsson, S., Kristjansson, A. K., & Unnþórsson, R. (2025) · Bioengineering · doi:10.3390/bioengineering12090989 · Cited by 18
“Due to the rapid advancement of prosthetic technologies [10–14], tactile feedback systems have been introduced as a viable method to counter sensory loss and provide amputees with some aspects of normal sensory feedback [15,16].”
Vujaklija, I., Jung, M., Hasenoehrl, T., Roche, A. D., Sturma, A., Muceli, S., Crevenna, R., Aszmann, O. C., & Farina, D. (2022) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2022.3202250 · Cited by 12
“Significant efforts have therefore been invested in advancing control algorithms [4].”
BackgroundSelf-citationSîmpetru, R., Braun, D. I., Simon, A. U., März, M., Cnejevici, V., de Oliveira, D. S., Weber, N., Wälter, J., Franke, J. E., Höglinger, D., et al. (2025) · Science Advances · doi:10.1126/sciadv.ads9150 · Cited by 16
Metadata
- Authors
- Farina, D., Vujaklija, I., Brånemark, R., Bull, A. M. J., Dietl, H., Graimann, B., Hargrove, L. J., Hoffmann, K.-P., Huang, H., Ingvarsson, T., Janusson, H. B., Kristjánsson, K., Kuiken, T., Micera, S., Stieglitz, T., Sturma, A., Tyler, D., Weir, R. F. F., & Aszmann, O. C.
- Affiliations
- Imperial College London (GB)
- Aalto University (FI)
- Sahlgrenska University Hospital (SE)
- Ottobock (Austria) (AT)
- Ottobock (Germany) (DE)
- Northwestern University (US)
- Fraunhofer Institute for Biomedical Engineering (DE)
- University of North Carolina at Chapel Hill (US)
- University of Iceland (IS)
- Össur (Iceland) (IS)
- Scuola Superiore Sant'Anna (IT)
- University of Freiburg (DE)
- Louis Stokes Cleveland VA Medical Center (US)
- VA Eastern Colorado Health Care System (US)
- Medical University of Vienna (AT)
- Corresponding author
- Farina, Dario
- ORCID
- Venue
- Nature Biomedical Engineering
- Published
- 2021-05-31
- Volume
- 7
- Issue
- 4
- Pages
- 473-485
- ISSN
- 2157-846X (ISSN-L)
- OpenAlex
- W3165882235
- Semantic Scholar
- 644c9b465b6c74a46e51f973d691c6c94e30c289
- Cited by
- 263
- References
- 251
- Citations by year
- 2026: 29 · 2025: 57 · 2024: 68 · 2023: 64 · 2022: 34 · 2021: 11
- FWCI
- 3.74
- Type
- journal article
- Language
- en
- Open access
- green
- research.aalto.fi
- Licence
- other-oa
- www.springernature.com/gp/researchers/text-and-data-mining (tdm)
- www.springernature.com/gp/researchers/text-and-data-mining (vor)
- Locations
- Nature Biomedical Engineering (publishedVersion)
- PubMed (publishedVersion)
- Aaltodoc (Aalto University) (submittedVersion, other-oa)
- Publikationsdatenbank der Fraunhofer-Gesellschaft (Fraunhofer-Gesellschaft) (submittedVersion)
- Infoscience (Ecole Polytechnique Fédérale de Lausanne) (submittedVersion, cc-by-nc-nd)
- Fraunhofer-Publica (Fraunhofer-Gesellschaft) (submittedVersion)
- Spiral (Imperial College London) (submittedVersion)
- CINECA IRIS Institutional Research Information System (Sant'Anna School of Advanced Studies) (submittedVersion)
- Funders
- U.S. Department of Veterans Affairs (I01 RX003355, I01 RX001334, IK6 RX003836)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Keywords
- bionic limbs, osseointegration, targeted muscle reinnervation, peripheral nerve stimulation, sensory feedback, neural interfaces, robotic prostheses, rehabilitation training, body ownership
- MeSH terms
- Artificial Limbs, Bionics, Electrodes, Extremities, Humans, Prosthesis Design
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
A second model labelled each claim on 2026-10-06 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.