Toward higher-performance bionic limbs for wider clinical use
Open accessThe DOI matches its Crossref record; 247 of the 251 references it cites were found in a registry or an index.
Abstract
Most prosthetic limbs can autonomously move with dexterity, yet they are not perceived by the user as belonging to their own body. Robotic limbs can convey information about the environment with higher precision than biological limbs, but their actual performance is substantially limited by current technologies for the interfacing of the robotic devices with the body and for transferring motor and sensory information bidirectionally between the prosthesis and the user. In this Perspective, we argue that direct skeletal attachment of bionic devices via osseointegration, the amplification of neural signals by targeted muscle innervation, improved prosthesis control via implanted muscle sensors and advanced algorithms, and the provision of sensory feedback by means of electrodes implanted in peripheral nerves, should all be leveraged towards the creation of a new generation of high-performance bionic limbs. These technologies have been clinically tested in humans, and alongside mechanical redesigns and adequate rehabilitation training should facilitate the wider clinical use of bionic limbs.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The text we found for this paper looks like another document, so the self-check wasn’t run.
Citations
Cites
A new strategy for multifunction myoelectric control
Hudgins, B., Parker, P., & Scott, R. N. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.204774 · Cited by 2,149 · cited 1×
“The natural patterns of muscle activation associated to specific movements are mapped by supervised learning to the corresponding tasks 78,79 .”
MethodBrain–machine interfaces: past, present and future
Lebedev, M. A., & Nicolelis, M. A. L. (2006) · Trends in Neurosciences · doi:10.1016/j.tins.2006.07.004 · Cited by 1,875
High-performance neuroprosthetic control by an individual with tetraplegia
Collinger, J. L., Wodlinger, B., Downey, J. E., Wang, W., Tyler-Kabara, E. C., Weber, D. J., McMorland, A. J., Velliste, M., Boninger, M. L., & Schwartz, A. B. (2013) · The Lancet · doi:10.1016/s0140-6736(12)61816-9 · Cited by 1,848 · cited 1×
“Implantable selective cortical electrodes can record from hundreds of cortical neurons, and this neural activity can then be associated with the online control of multiple degrees of freedom 132,133 .”
BackgroundUse of NeuroEyeCoach™ to Improve Eye Movement Efficacy in Patients with Homonymous Visual Field Loss
Sahraie, A., Smania, N., & Zihl, J. (2016) · BioMed Research International · doi:10.1155/2016/5186461 · Cited by 1,772
A robust, real-time control scheme for multifunction myoelectric control
Englehart, K., & Hudgins, B. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.813539 · Cited by 1,743
Upper limb prosthesis use and abandonment: A survey of the last 25 years
Biddiss, E. A., & Chau, T. T. (2007) · Prosthetics & Orthotics International · doi:10.1080/03093640600994581 · Cited by 1,111
Targeted Muscle Reinnervation for Real-time Myoelectric Control of Multifunction Artificial Arms
Kuiken, T. A. (2009) · JAMA · doi:10.1001/jama.2009.116 · Cited by 1,089 · cited 1×
“…in redirecting nerves that have lost their natural target muscles to other muscle tissues so as to biologically amplify the activity of the redirected nerve 115–119 — can provide a form of ‘bioscreen’ that displays, via muscle electrical signals, the neural activity of the transferred nerves.”
BackgroundSelf-citationRestoring natural sensory feedback in real-time bidirectional hand prostheses
Raspopovic, S., Capogrosso, M., Petrini, F. M., Bonizzato, M., Rigosa, J., Di Pino, G., Carpaneto, J., Controzzi, M., Boretius, T., Fernandez, E., et al. (2014) · Science Translational Medicine · doi:10.1126/scitranslmed.3006820 · Cited by 1,001 · cited 2×
“This class of implants can establish natural tactile sensations 42,194–196, Epidural stimulation of the spinal cord has been shown to evoke sensory precepts in the missing limbs of amputees 203 .”
BackgroundSelf-citationScheme, E., & Englehart, K. (2011) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2010.09.0177 · Cited by 969
Hands for dexterous manipulation and robust grasping: a difficult road toward simplicity
Bicchi, A. (2000) · IEEE Transactions on Robotics and Automation · doi:10.1109/70.897777 · Cited by 895
Navarro, X., Krueger, T. B., Lago, N., Micera, S., Stieglitz, T., & Dario, P. (2005) · Journal of the Peripheral Nervous System · doi:10.1111/j.1085-9489.2005.10303.x · Cited by 845 · cited 2×
“User intent in lower and upper limbs can also be decoded from electrical activity recorded from efferent axons in peripheral nerves 102–105 .”
BackgroundSelf-citationOsseointegration in skeletal reconstruction and rehabilitation: a review.
Brånemark, R., Brånemark, P., Rydevik, B. L., & Myers, R. R. (2001) · PubMed · Cited by 840
Self-citationLiterature Review on Needs of Upper Limb Prosthesis Users
Cordella, F., Ciancio, A. L., Sacchetti, R., Davalli, A., Cutti, A. G., Guglielmelli, E., & Zollo, L. (2016) · Frontiers in Neuroscience · doi:10.3389/fnins.2016.00209 · Cited by 752
A neural interface provides long-term stable natural touch perception
Tan, D. W., Schiefer, M. A., Keith, M. W., Anderson, J. R., Tyler, J., & Tyler, D. J. (2014) · Science Translational Medicine · doi:10.1126/scitranslmed.3008669 · Cited by 751 · cited 2×
“Although long-term nerve implants are feasible 103,114,195,231–234 and promising for versatile clinical and home uses 96,235 , their wider clinical translation will require substantial developments regarding device stability, their integration into fully implantable systems, and the modularity of…”
BackgroundSelf-citationMechanical design and performance specifications of anthropomorphic prosthetic hands: A review
Belter, J. T., Segil, J. L., Dollar, A. M., & Weir, R. F. (2013) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2011.10.0188 · Cited by 716
Self-citationA wavelet-based continuous classification scheme for multifunction myoelectric control
Englehart, K., Hudgin, B., & Parker, P. A. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.914793 · Cited by 697 · cited 1×
“%) can be achieved for a relatively large number of classes of task 80–83 .”
BackgroundRobot Grasp Synthesis Algorithms: A Survey
Shimoga, K. B. (1996) · The International Journal of Robotics Research · doi:10.1177/027836499601500302 · Cited by 666
Myoelectric signal processing for control of powered limb prostheses
Parker, P., Englehart, K., & Hudgins, B. (2006) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2006.08.006 · Cited by 651
Design and Control of a Powered Transfemoral Prosthesis
Sup, F., Bohara, A., & Goldfarb, M. (2008) · The International Journal of Robotics Research · doi:10.1177/0278364907084588 · Cited by 586
Kuiken, T. A., Dumanian, G. A., Lipschutz, R. D., Miller, L. A., & Stubblefield, K. A. (2004) · Prosthetics & Orthotics International · doi:10.3109/03093640409167756 · Cited by 583
Self-citationHuang, H., Zhang, F., Hargrove, L. J., Dou, Z., Rogers, D. R., & Englehart, K. B. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2161671 · Cited by 542 · cited 3×
“They can be developed to interpret information from mechanical sensors only 54,58,154,155 , or from combined mechanical and electromyography information 59,69 .”
BackgroundMethodSelf-citationWodlinger, B., Downey, J. E., Tyler-Kabara, E. C., Schwartz, A. B., Boninger, M. L., & Collinger, J. L. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/1/016011 · Cited by 536 · cited 1×
“Implantable selective cortical electrodes can record from hundreds of cortical neurons, and this neural activity can then be associated with the online control of multiple degrees of freedom 132,133 .”
BackgroundConsumer design priorities for upper limb prosthetics
Biddiss, E., Beaton, D., & Chau, T. (2007) · Disability and Rehabilitation: Assistive Technology · doi:10.1080/17483100701714733 · Cited by 519
A Strategy for Identifying Locomotion Modes Using Surface Electromyography
Huang, H., Kuiken, T. A., & Lipschutz, R. D. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.2003293 · Cited by 512
Self-citationPowered ankle-foot prosthesis to assist level-ground and stair-descent gaits
Au, S., Berniker, M., & Herr, H. (2008) · Neural Networks · doi:10.1016/j.neunet.2008.03.006 · Cited by 487
Ortiz-Catalan, M., Håkansson, B., & Brånemark, R. (2014) · Science Translational Medicine · doi:10.1126/scitranslmed.3008933 · Cited by 484 · cited 6×
“3), has shown that they can provide superior electromyography data quality than surface recordings 42 .”
BackgroundInfluentialSelf-citationKuiken, T. A., Miller, L. A., Lipschutz, R. D., Lock, B. A., Stubblefield, K., Marasco, P. D., Zhou, P., & Dumanian, G. A. (2007) · The Lancet · doi:10.1016/s0140-6736(07)60193-7 · Cited by 482
Self-citationMyoelectric forearm prostheses: State of the art from a user-centered perspective
Peerdeman, B., Boere, D., Witteveen, H., Huis in `tVeld, R., Hermens, H., Stramigioli, S., Rietman, H., Veltink, P., & Misra, S. (2011) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2010.08.0161 · Cited by 469
A transverse intrafascicular multichannel electrode (TIME) to interface with the peripheral nerve
Boretius, T., Badia, J., Pascual-Font, A., Schuettler, M., Navarro, X., Yoshida, K., & Stieglitz, T. (2010) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.05.010 · Cited by 468
Self-citationAn overview of dexterous manipulation
Okamura, A. M., Smaby, N., & Cutkosky, M. R. (2002) · Proceedings 2000 ICRA. Millennium Conference. IEEE International Conference on Robotics and Automation. Symposia Proceedings (Cat. No.00CH37065) · doi:10.1109/robot.2000.844067 · Cited by 466
Myoelectric Control of Artificial Limbs—Is There a Need to Change Focus? [In the Spotlight]
Jiang, N., Dosen, S., Muller, K.-R., & Farina, D. (2012) · IEEE Signal Processing Magazine · doi:10.1109/msp.2012.2203480 · Cited by 434
Self-citationMulticlass Real-Time Intent Recognition of a Powered Lower Limb Prosthesis
Varol, H. A., Sup, F., & Goldfarb, M. (2010) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2009.2034734 · Cited by 425
Double nerve intraneural interface implant on a human amputee for robotic hand control
Rossini, P. M., Micera, S., Benvenuto, A., Carpaneto, J., Cavallo, G., Citi, L., Cipriani, C., Denaro, L., Denaro, V., Di Pino, G., et al. (2010) · Clinical Neurophysiology · doi:10.1016/j.clinph.2010.01.001 · Cited by 396 · cited 1×
“However, electroneurographic signals have a low signal-to-noise ratio and limited stability 106 , making it challenging to decode the activity of efferent fibres with intrafascicular nerve implants 113 .”
BackgroundSelf-citationDillingham, T. R., Pezzin, L. E., MacKenzie, E. J., & Burgess, A. R. (2001) · American Journal of Physical Medicine & Rehabilitation · doi:10.1097/00002060-200108000-00003 · Cited by 385
Farina, D., Vujaklija, I., Sartori, M., Kapelner, T., Negro, F., Jiang, N., Bergmeister, K., Andalib, A., Principe, J., & Aszmann, O. C. (2017) · Nature Biomedical Engineering · doi:10.1038/s41551-016-0025 · Cited by 359 · cited 2×
“Recently, the multiunit muscle signals generated following nerve transfers have been decoded by source separation algorithms 120,121118,122,123 , thus providing a direct interface with spinal motor neurons 118,124– 127 .”
BackgroundSelf-citationFunctional Separation of EMG Signals via ARMA Identification Methods for Prosthesis Control Purposes
Graupe, D., & Cline, W. K. (1975) · IEEE Transactions on Systems, Man, and Cybernetics · doi:10.1109/tsmc.1975.5408479 · Cited by 354 · cited 1×
“The natural patterns of muscle activation associated to specific movements are mapped by supervised learning to the corresponding tasks 78,79 .”
MethodValle, G., Mazzoni, A., Iberite, F., D’Anna, E., Strauss, I., Granata, G., Controzzi, M., Clemente, F., Rognini, G., Cipriani, C., et al. (2018) · Neuron · doi:10.1016/j.neuron.2018.08.033 · Cited by 345
Self-citationRobotic touch shifts perception of embodiment to a prosthesis in targeted reinnervation amputees
Marasco, P. D., Kim, K., Colgate, J. E., Peshkin, M. A., & Kuiken, T. A. (2011) · Brain · doi:10.1093/brain/awq361 · Cited by 335 · cited 1×
“It is also possible to elicit natural phantom-limb sensations by targeting sites on the skin that have been surgically reinnervated (targeted sensory reinnervation) 189–191 .”
BackgroundSelf-citationOddo, C. M., Raspopovic, S., Artoni, F., Mazzoni, A., Spigler, G., Petrini, F., Giambattistelli, F., Vecchio, F., Miraglia, F., Zollo, L., et al. (2016) · eLife · doi:10.7554/elife.09148 · Cited by 332
Self-citationSartori, M., Reggiani, M., Farina, D., & Lloyd, D. G. (2012) · PLoS ONE · doi:10.1371/journal.pone.0052618 · Cited by 330
Self-citationA closed-loop hand prosthesis with simultaneous intraneural tactile and position feedback
D’Anna, E., Valle, G., Mazzoni, A., Strauss, I., Iberite, F., Patton, J., Petrini, F. M., Raspopovic, S., Granata, G., Di Iorio, R., et al. (2019) · Science Robotics · doi:10.1126/scirobotics.aau8892 · Cited by 321
Self-citationDavis, T. S., Wark, H. A. C., Hutchinson, D. T., Warren, D. J., O’Neill, K., Scheinblum, T., Clark, G. A., Normann, R. A., & Greger, B. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/3/036001 · Cited by 314
Vu, P. P., Vaskov, A. K., Irwin, Z. T., Henning, P. T., Lueders, D. R., Laidlaw, A. T., Davis, A. J., Nu, C. S., Gates, D. H., Gillespie, R. B., et al. (2020) · Science Translational Medicine · doi:10.1126/scitranslmed.aay2857 · Cited by 291 · cited 1×
“These individual groups of contracting muscle can then produce high-fidelity motor-control signals with favourable signal-to-noise ratios for the real-time control of a prosthesis 129–131 .”
BackgroundSensory feedback restoration in leg amputees improves walking speed, metabolic cost and phantom pain
Petrini, F. M., Bumbasirevic, M., Valle, G., Ilic, V., Mijović, P., Čvančara, P., Barberi, F., Katic, N., Bortolotti, D., Andreu, D., et al. (2019) · Nature Medicine · doi:10.1038/s41591-019-0567-3 · Cited by 269
Self-citationJiang, N., Rehbaum, H., Vujaklija, I., Graimann, B., & Farina, D. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2013.2278411 · Cited by 269
Self-citationImplantable Myoelectric Sensors (IMESs) for Intramuscular Electromyogram Recording
Weir, R. F., Troyk, P. R., DeMichele, G. A., Kerns, D. A., Schorsch, J. F., & Maas, H. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.2005942 · Cited by 266
Self-citationRestoration of sensory information via bionic hands
Bensmaia, S. J., Tyler, D. J., & Micera, S. (2020) · Nature Biomedical Engineering · doi:10.1038/s41551-020-00630-8 · Cited by 257
Self-citationResults of an internet survey of myoelectric prosthetic hand users
Pylatiuk, C., Schulz, S., & Döderlein, L. (2007) · Prosthetics & Orthotics International · doi:10.1080/03093640601061265 · Cited by 257
Self-Contained Neuromusculoskeletal Arm Prostheses
Ortiz-Catalan, M., Mastinu, E., Sassu, P., Aszmann, O., & Brånemark, R. (2020) · New England Journal of Medicine · doi:10.1056/nejmoa1917537 · Cited by 256 · cited 2×
“If the risk of infections can be reduced, the presence of a percutaneous port in form of an osseointegrated attachment can in principle be exploited by implanted technology that transmits information in and out the user’s body without the need for wireless technology 42–44 .”
BackgroundSelf-citationOsseointegrated Titanium Implants for Limb Prostheses Attachments: Infectious Complications
Tillander, J., Hagberg, K., Hagberg, L., & Brånemark, R. (2010) · Clinical Orthopaedics & Related Research · doi:10.1007/s11999-010-1370-0 · Cited by 242
Self-citationSensinger, J. W., Lock, B. A., & Kuiken, T. A. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2023282 · Cited by 239
Self-citationHagberg, K., Brånemark, R., Gunterberg, B., & Rydevik, B. (2008) · Prosthetics & Orthotics International · doi:10.1080/03093640701553922 · Cited by 230
Self-citationSartori, M., Farina, D., & Lloyd, D. G. (2014) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2014.10.009 · Cited by 229
Self-citationDifferences in myoelectric and body-powered upper-limb prostheses: systematic literature review
Carey, S. L., Lura, D. J., Highsmith, M. J., CP, & FAAOP (2015) · Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2014.08.0192 · Cited by 227
Simon, A. M., Hargrove, L. J., Lock, B. A., & Kuiken, T. A. (2011) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2010.08.0149 · Cited by 226
Self-citationDesign and clinical implementation of an open-source bionic leg
Azocar, A. F., Mooney, L. M., Duval, J.-F., Simon, A. M., Hargrove, L. J., & Rouse, E. J. (2020) · Nature Biomedical Engineering · doi:10.1038/s41551-020-00619-3 · Cited by 223
Self-citationHahne, J. M., Schweisfurth, M. A., Koppe, M., & Farina, D. (2018) · Science Robotics · doi:10.1126/scirobotics.aat3630 · Cited by 216
Self-citationGraczyk, E. L., Resnik, L., Schiefer, M. A., Schmitt, M. S., & Tyler, D. J. (2018) · Scientific Reports · doi:10.1038/s41598-018-26952-x · Cited by 216
Self-citationD’Anna, E., Petrini, F. M., Artoni, F., Popovic, I., Simanić, I., Raspopovic, S., & Micera, S. (2017) · Scientific Reports · doi:10.1038/s41598-017-11306-w · Cited by 215
Self-citationDecoding a New Neural–Machine Interface for Control of Artificial Limbs
Zhou, P., Lowery, M. M., Englehart, K. B., Huang, H., Li, G., Hargrove, L., Dewald, J. P. A., & Kuiken, T. A. (2007) · Journal of Neurophysiology · doi:10.1152/jn.00178.2007 · Cited by 215 · cited 1×
“For example, clinically available technology for controlling upper-limb prostheses has remained almost unchanged for the past 50 years, and can still control at most two degrees of freedom (one at a time), and in an unnatural manner 30,31 .”
BackgroundSelf-citationAgonist-antagonist active knee prosthesis: a preliminary study in level-ground walking.
Martinez-Villalpando, E. C., & Herr, H. (2009) · PubMed · Cited by 214
Hargrove, L. J., Li, G., Englehart, K. B., & Hudgins, B. S. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.2008171 · Cited by 211
Self-citationSimon, A. M., Ingraham, K. A., Fey, N. P., Finucane, S. B., Lipschutz, R. D., Young, A. J., & Hargrove, L. J. (2014) · PLoS ONE · doi:10.1371/journal.pone.0099387 · Cited by 207
Self-citationControl of Stair Ascent and Descent With a Powered Transfemoral Prosthesis
Lawson, B. E., Varol, H. A., Huff, A., Erdemir, E., & Goldfarb, M. (2013) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2012.2225640 · Cited by 206
Pasquina, P. F., Evangelista, M., Carvalho, A. J., Lockhart, J., Griffin, S., Nanos, G., McKay, P., Hansen, M., Ipsen, D., Vandersea, J., et al. (2015) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2014.07.016 · Cited by 205
Volitional Control of a Prosthetic Knee Using Surface Electromyography
Ha, K. H., Varol, H. A., & Goldfarb, M. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2070840 · Cited by 205
Six‐Month Assessment of a Hand Prosthesis with Intraneural Tactile Feedback
Petrini, F. M., Valle, G., Strauss, I., Granata, G., Di Iorio, R., D'Anna, E., Čvančara, P., Mueller, M., Carpaneto, J., Clemente, F., et al. (2019) · Annals of Neurology · doi:10.1002/ana.25384 · Cited by 195
Self-citationAntfolk, C., D'Alonzo, M., Controzzi, M., Lundborg, G., Rosen, B., Sebelius, F., & Cipriani, C. (2013) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2012.2217989 · Cited by 194
Horch, K., Meek, S., Taylor, T. G., & Hutchinson, D. T. (2011) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2011.2162635 · Cited by 194 · cited 1×
“Moreover, establishing tactile sensory feedback while providing proprioception 236 is challenging 237,238 .”
BackgroundThe role of feed-forward and feedback processes for closed-loop prosthesis control
Saunders, I., & Vijayakumar, S. (2011) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-8-60 · Cited by 193
Neural Data-Driven Musculoskeletal Modeling for Personalized Neurorehabilitation Technologies
Sartori, M., Llyod, D. G., & Farina, D. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2016.2538296 · Cited by 188
Self-citationSocket Versus Bone-Anchored Trans-Femoral Prostheses: Hip Range of Motion and Sitting Comfort
Hagberg, K., Häggström, E., Uden, M., & Brånemark, R. (2005) · Prosthetics & Orthotics International · doi:10.1080/03093640500238014 · Cited by 187
Self-citationRohm, M., Schneiders, M., Müller, C., Kreilinger, A., Kaiser, V., Müller-Putz, G. R., & Rupp, R. (2013) · Artificial Intelligence in Medicine · doi:10.1016/j.artmed.2013.07.004 · Cited by 187
Safety of Osseointegrated Implants for Transfemoral Amputees: A Two-Center Prospective Cohort Study
Al Muderis, M., Khemka, A., Lord, S. J., Van de Meent, H., & Frölke, J. P. M. (2016) · Journal of Bone and Joint Surgery · doi:10.2106/jbjs.15.00808 · Cited by 185
New developments in prosthetic arm systems
Vujaklija, I., Farina, D., & Aszmann, O. (2016) · Orthopedic Research and Reviews · doi:10.2147/orr.s71468 · Cited by 185
Self-citationROTATION-PLASTY FOR CONGENITAL DEFECTS OF THE FEMUR
Van Nes, C. P. (1950) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.32b1.12 · Cited by 185
Development of a lightweight and adaptable multiple-axis hand prosthesis
Light, C. M., & Chappell, P. H. (2000) · Medical Engineering & Physics · doi:10.1016/s1350-4533(01)00017-0 · Cited by 178
Long-term usability and bio-integration of polyimide-based intra-neural stimulating electrodes
Wurth, S., Capogrosso, M., Raspopovic, S., Gandar, J., Federici, G., Kinany, N., Cutrone, A., Piersigilli, A., Pavlova, N., Guiet, R., et al. (2017) · Biomaterials · doi:10.1016/j.biomaterials.2017.01.014 · Cited by 176
Self-citationZollo, L., Di Pino, G., Ciancio, A. L., Ranieri, F., Cordella, F., Gentile, C., Noce, E., Romeo, R. A., Dellacasa Bellingegni, A., Vadalà, G., et al. (2019) · Science Robotics · doi:10.1126/scirobotics.aau9924 · Cited by 175
Self-citationTan, D. W., Schiefer, M. A., Keith, M. W., Anderson, J. R., & Tyler, D. J. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/2/026002 · Cited by 175
Self-citationSelective Classification for Improved Robustness of Myoelectric Control Under Nonideal Conditions
Scheme, E. J., Englehart, K. B., & Hudgins, B. S. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2113182 · Cited by 172
Myoelectric Prostheses: state of the art
Scott, R. N., & Parker, P. A. (1988) · Journal of Medical Engineering & Technology · doi:10.3109/03091908809030173 · Cited by 171
Advanced Neurotechnologies for the Restoration of Motor Function
Micera, S., Caleo, M., Chisari, C., Hummel, F. C., & Pedrocchi, A. (2020) · Neuron · doi:10.1016/j.neuron.2020.01.039 · Cited by 171
Self-citationSensing tactile microvibrations with the BioTac — Comparison with human sensitivity
Fishel, J. A., & Loeb, G. E. (2012) · 2012 4th IEEE RAS & EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob) · doi:10.1109/biorob.2012.6290741 · Cited by 170
Osseointegration amputation prostheses on the upper limbs: methods, prosthetics and rehabilitation
Jönsson, S., Caine-Winterberger, K., & Brånemark, R. (2011) · Prosthetics & Orthotics International · doi:10.1177/0309364611409003 · Cited by 170
Self-citationProsthetic fitting, use, and satisfaction following lower-limb amputation: A prospective study
Webster, J. B., Hakimi, K. N., Williams, R. M., Turner, A. P., Norvell, D. C., & Czerniecki, J. M. (2012) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2012.01.0001 · Cited by 169
Cutaneous whole nerve recordings used for correction of footdrop in hemiplegic man
Haugland, M. K., & Sinkjaer, T. (1995) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.481970 · Cited by 168
A Survey on Activities of Daily Living and Occupations of Upper Extremity Amputees
Jang, C. H., Yang, H. S., Yang, H. E., Lee, S. Y., Kwon, J. W., Yun, B. D., Choi, J. Y., Kim, S. N., & Jeong, H. W. (2011) · Annals of Rehabilitation Medicine · doi:10.5535/arm.2011.35.6.907 · Cited by 165
Neurocognitive barriers to the embodiment of technology
Makin, T. R., de Vignemont, F., & Faisal, A. A. (2017) · Nature Biomedical Engineering · doi:10.1038/s41551-016-0014 · Cited by 165 · cited 2×
“To decrease cognitive load in the use of prostheses, it is evident that intuitive or ‘natural’ control — the continuous and simultaneous control over multiple degrees of freedom with physiological correspondence between (neural) intention and (prosthetic) action — is desirable 138 .”
BackgroundHeterotopic Ossification Following Combat-Related Trauma
Potter, M. B. K., Forsberg, L. J. A., Davis, T. A., Evans, C. K. N., Hawksworth, M. J. S., Tadaki, D. K., Brown, T. S., Crane, N. J., Burns, M. T., O’Brien, C. F. P., et al. (2010) · Journal of Bone and Joint Surgery · doi:10.2106/jbjs.j.00776 · Cited by 164
Examining the adverse effects of limb position on pattern recognition based myoelectric control
Scheme, E., Fougner, A., Stavdahl, Ø., Chan, A. D. C., & Englehart, K. (2010) · 2010 Annual International Conference of the IEEE Engineering in Medicine and Biology · doi:10.1109/iembs.2010.5627638 · Cited by 161
Intent Recognition in a Powered Lower Limb Prosthesis Using Time History Information
Young, A. J., Simon, A. M., Fey, N. P., & Hargrove, L. J. (2014) · Annals of Biomedical Engineering · doi:10.1007/s10439-013-0909-0 · Cited by 160
Self-citationManaging the Upper Extremity Amputee: A Protocol for Success
Smurr, L. M., Gulick, K., Yancosek, K., & Ganz, O. (2008) · Journal of Hand Therapy · doi:10.1197/j.jht.2007.09.006 · Cited by 158
Bionic Limbs: Clinical Reality and Academic Promises
Farina, D., & Aszmann, O. (2014) · Science Translational Medicine · doi:10.1126/scitranslmed.3010453 · Cited by 157
Self-citationRobust Real-Time Musculoskeletal Modeling Driven by Electromyograms
Durandau, G., Farina, D., & Sartori, M. (2018) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2017.2704085 · Cited by 157
Self-citationIntuitive Control of a Powered Prosthetic Leg During Ambulation: A Randomized Clinical Trial
Hargrove, L. J., Young, A. J., Simon, A. M., Fey, N. P., Lipschutz, R. D., Finucane, S. B., Halsne, E. G., Ingraham, K. A., & Kuiken, T. A. (2015) · JAMA · doi:10.1001/jama.2015.4527 · Cited by 153
Self-citationAszmann, O. C., Roche, A. D., Salminger, S., Paternostro-Sluga, T., Herceg, M., Sturma, A., Hofer, C., & Farina, D. (2015) · The Lancet · doi:10.1016/s0140-6736(14)61776-1 · Cited by 152
Self-citationReturn to work after lower limb amputation
Burger, H., & Marinček, Č. (2007) · Disability and Rehabilitation · doi:10.1080/09638280701320797 · Cited by 152
Skin Problems of the Stump in Lower Limb Amputees: 1. A Clinical Study
Meulenbelt, H. E. J., Geertzen, J. H. B., Jonkman, M. F., & Dijkstra, P. U. (2011) · Acta Dermato Venereologica · doi:10.2340/00015555-1040 · Cited by 151
A Training Method for Locomotion Mode Prediction Using Powered Lower Limb Prostheses
Young, A. J., Simon, A. M., & Hargrove, L. J. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2013.2285101 · Cited by 150
Self-citationSartori, M., Durandau, G., Došen, S., & Farina, D. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aae26b · Cited by 148 · cited 3×
“For example, electromyography-driven musculoskeletal models of upper and lower limbs for myocontrol may provide a ‘solution space’ for control that is less sensitive to changes in muscle coordination than data-driven machine-learning techniques 146,150,151 .”
BackgroundMethodSelf-citationPatterson, P. E., & Katz, J. A. (1992) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.1992.01.0001 · Cited by 147 · cited 1×
“…on the tactile receptors via the use of, for instance, vibration motors 172,173 , linear pushers 174,175 , skin stretchers 176,177 or pressure cuffs 178 ) or electrical 179–181 (via the delivery of low-intensity pulses of current through surface electrodes to activate cutaneous afferents or to…”
BackgroundWheeler, J., Bark, K., Savall, J., & Cutkosky, M. (2010) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2039602 · Cited by 146
Ortiz-Catalan, M., Brånemark, R., Håkansson, B., & Delbeke, J. (2012) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-11-33 · Cited by 144
Self-citationChronic Response of the Rat Sciatic Nerve to the Flat Interface Nerve Electrode
Tyler, D. J., & Durand, D. M. (2003) · Annals of Biomedical Engineering · doi:10.1114/1.1569263 · Cited by 144
Self-citationAn EMG-Position Controlled System for an Active Ankle-Foot Prosthesis: An Initial Experimental Study
Au, S. K., Bonato, P., & Herr, H. (2005) · 9th International Conference on Rehabilitation Robotics, 2005. ICORR 2005. · doi:10.1109/icorr.2005.1501123 · Cited by 142
Online adaptive neural control of a robotic lower limb prosthesis
Spanias, J. A., Simon, A. M., Finucane, S. B., Perreault, E. J., & Hargrove, L. J. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa92a8 · Cited by 141
Self-citationShared human–robot proportional control of a dexterous myoelectric prosthesis
Zhuang, K. Z., Sommer, N., Mendez, V., Aryan, S., Formento, E., D’Anna, E., Artoni, F., Petrini, F., Granata, G., Cannaviello, G., et al. (2019) · Nature Machine Intelligence · doi:10.1038/s42256-019-0093-5 · Cited by 140
Self-citationSalminger, S., Sturma, A., Hofer, C., Evangelista, M., Perrin, M., Bergmeister, K. D., Roche, A. D., Hasenoehrl, T., Dietl, H., Farina, D., et al. (2019) · Science Robotics · doi:10.1126/scirobotics.aaw6306 · Cited by 139 · cited 1×
“IMES implants have been stable for over 4 years 101 .”
BackgroundSelf-citationKuiken, T. A., Miller, L. A., Turner, K., & Hargrove, L. J. (2016) · IEEE Journal of Translational Engineering in Health and Medicine · doi:10.1109/jtehm.2016.2616123 · Cited by 135
Self-citationThe effect of electrode displacements on pattern recognition based myoelectric control
Hargrove, L., Englehart, K., & Hudgins, B. (2006) · 2006 International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2006.260681 · Cited by 135
Self-citationDexterous manipulation through rolling
Bicchi, A., & Sorrentino, R. (2002) · Proceedings of 1995 IEEE International Conference on Robotics and Automation · doi:10.1109/robot.1995.525325 · Cited by 133
Return to work after lower limb amputation
Fisher, K., Hanspal, R. S., & Marks, L. (2003) · International Journal of Rehabilitation Research · doi:10.1097/00004356-200303000-00007 · Cited by 133
Ison, M. R., Vujaklija, I., Whitsell, B., Farina, D., & Artemiadis, P. (2015) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2015.2417775 · Cited by 132
Self-citationImplantable electrical and mechanical interfaces with nerve and muscle
Hoffer, J. A., & Loeb, G. E. (1980) · Annals of Biomedical Engineering · doi:10.1007/bf02363438 · Cited by 131
Targeted reinnervation for transhumeral amputees: current surgical technique and update on results
Dumanian, G. A., Ko, J. H., O’Shaughnessy, K. D., Kim, P. S., Wilson, C. J., & Kuiken, T. A. (2009) · Plastic and Reconstructive Surgery · doi:10.1097/prs.0b013e3181b038c9 · Cited by 130
Self-citationThe Cybathlon promotes the development of assistive technology for people with physical disabilities
Riener, R. (2016) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-016-0157-2 · Cited by 127
Hahne, J. M., Dähne, S., Hwang, H., Müller, K., & Parra, L. C. (2015) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2015.2401134 · Cited by 126
Psychological Adjustment and Coping in Adults With Prosthetic Limbs
Gallagher, P., & MacLachlan, M. (1999) · Behavioral Medicine · doi:10.1080/08964289909596741 · Cited by 123
User adaptation in Myoelectric Man-Machine Interfaces
Hahne, J. M., Markovic, M., & Farina, D. (2017) · Scientific Reports · doi:10.1038/s41598-017-04255-x · Cited by 121
Self-citationDevelopment of an Implantable Myoelectric Sensor for Advanced Prosthesis Control
Merrill, D. R., Lockhart, J., Troyk, P. R., Weir, R. F., & Hankin, D. L. (2011) · Artificial Organs · doi:10.1111/j.1525-1594.2011.01219.x · Cited by 117 · cited 1×
“97,98 ; Fig.”
Self-citationSensory restoration by epidural stimulation of the lateral spinal cord in upper-limb amputees
Chandrasekaran, S., Nanivadekar, A. C., McKernan, G., Helm, E. R., Boninger, M. L., Collinger, J. L., Gaunt, R. A., & Fisher, L. E. (2020) · eLife · doi:10.7554/elife.54349 · Cited by 116
Schiefer, M. A., Graczyk, E. L., Sidik, S. M., Tan, D. W., & Tyler, D. J. (2018) · PLOS ONE · doi:10.1371/journal.pone.0207659 · Cited by 115
Self-citationDevelopment of a regenerative peripheral nerve interface for control of a neuroprosthetic limb
Urbanchek, M. G., Kung, T. A., Frost, C. M., Martin, D. C., Larkin, L. M., Wollstein, A., & Cederna, P. S. (2016) · BioMed Research International · doi:10.1155/2016/5726730 · Cited by 114 · cited 1×
“These regenerative peripheral-nerve interfaces decodes the neural activity by selectively recording the muscular electrical signals generated by only a small number of nerve fibres, which increases the number of discrete signals available for prosthetic control 128 .”
BackgroundSensory capacity of reinnervated skin after redirection of amputated upper limb nerves to the chest
Marasco, P. D., Schultz, A. E., & Kuiken, T. A. (2009) · Brain · doi:10.1093/brain/awp082 · Cited by 113
Self-citationRealizing the Promise of Robotic Leg Prostheses
Goldfarb, M., Lawson, B. E., & Shultz, A. H. (2013) · Science Translational Medicine · doi:10.1126/scitranslmed.3007312 · Cited by 112
Sturma, A., Hruby, L. A., Prahm, C., Mayer, J. A., & Aszmann, O. C. (2018) · Frontiers in Neuroscience · doi:10.3389/fnins.2018.00906 · Cited by 110
Self-citationSchweitzer, W., Thali, M. J., & Egger, D. (2018) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-017-0340-0 · Cited by 110
Electrotactile EMG feedback improves the control of prosthesis grasping force
Schweisfurth, M. A., Markovic, M., Dosen, S., Teich, F., Graimann, B., & Farina, D. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/5/056010 · Cited by 110
Self-citationA cognitive neuroprosthetic that uses cortical stimulation for somatosensory feedback
Klaes, C., Shi, Y., Kellis, S., Minxha, J., Revechkis, B., & Andersen, R. A. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/5/056024 · Cited by 110
Context-Dependent Upper Limb Prosthesis Control for Natural and Robust Use
Amsuess, S., Vujaklija, I., Goebel, P., Roche, A. D., Graimann, B., Aszmann, O. C., & Farina, D. (2016) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2015.2454240 · Cited by 109
Self-citationJarvis, H. L., Bennett, A. N., Twiste, M., Phillip, R. D., Etherington, J., & Baker, R. J. (2016) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2016.09.134 · Cited by 109
Vibrotactile grasping force and hand aperture feedback for myoelectric forearm prosthesis users
Witteveen, H. J., Rietman, H. S., & Veltink, P. H. (2015) · Prosthetics & Orthotics International · doi:10.1177/0309364614522260 · Cited by 108
Crouch, D. L., & Huang, H. (2016) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2016.10.035 · Cited by 107
Self-citationIntegrated and flexible multichannel interface for electrotactile stimulation
Štrbac, M., Belić, M., Isaković, M., Kojić, V., Bijelić, G., Popović, I., Radotić, M., Došen, S., Marković, M., Farina, D., et al. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/4/046014 · Cited by 106
Self-citationNeural interfaces for somatosensory feedback: bringing life to a prosthesis
Tyler, D. J. (2015) · Current Opinion in Neurology · doi:10.1097/wco.0000000000000266 · Cited by 105
Self-citationSensory-feedback system compatible with myoelectric control
Scott, R. N., Brittain, R. H., Caldwell, R. R., Cameron, A. B., & Dunfield, V. A. (1980) · Medical & Biological Engineering & Computing · doi:10.1007/bf02442481 · Cited by 104
Source Selection for Real-Time User Intent Recognition Toward Volitional Control of Artificial Legs
Zhang, F., & Huang, H. (2013) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2012.2236563 · Cited by 103
Self-citationPatient Training for Functional Use of Pattern Recognition–Controlled Prostheses
Simon, A. M., Lock, B. A., & Stubblefield, K. A. (2012) · JPO Journal of Prosthetics and Orthotics · doi:10.1097/jpo.0b013e3182515437 · Cited by 102
Neural machine interfaces for controlling multifunctional powered upper-limb prostheses
Ohnishi, K., Weir, R. F., & Kuiken, T. A. (2007) · Expert Review of Medical Devices · doi:10.1586/17434440.4.1.43 · Cited by 102
Self-citationMicera, S., Rossini, P. M., Rigosa, J., Citi, L., Carpaneto, J., Raspopovic, S., Tombini, M., Cipriani, C., Assenza, G., Carrozza, M. C., et al. (2011) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-8-53 · Cited by 100 · cited 2×
“However, electroneurographic signals have a low signal-to-noise ratio and limited stability 106 , making it challenging to decode the activity of efferent fibres with intrafascicular nerve implants 113 .”
BackgroundSelf-citationSurvey of upper limb prosthesis users in Sweden, the United Kingdom and Canada
Kyberd, P. J., & Hill, W. (2011) · Prosthetics & Orthotics International · doi:10.1177/0309364611409099 · Cited by 98
Mastinu, E., Doguet, P., Botquin, Y., Hakansson, B., & Ortiz-Catalan, M. (2017) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2017.2694710 · Cited by 97
Vujaklija, I., Roche, A. D., Hasenoehrl, T., Sturma, A., Amsuess, S., Farina, D., & Aszmann, O. C. (2017) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2017.00007 · Cited by 96
Self-citationNeural feedback strategies to improve grasping coordination in neuromusculoskeletal prostheses
Mastinu, E., Engels, L. F., Clemente, F., Dione, M., Sassu, P., Aszmann, O. C., Brånemark, R., Håkansson, B. E. V., Controzzi, M., Wessberg, J., et al. (2020) · Scientific Reports · doi:10.1038/s41598-020-67985-5 · Cited by 94
Self-citationDetection of and Compensation for EMG Disturbances for Powered Lower Limb Prosthesis Control
Spanias, J. A., Perreault, E. J., & Hargrove, L. J. (2016) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2015.2413393 · Cited by 93
Self-citationStrbac, M. D., Isaković, M. S., Belić, M., Popovic, I., Igor, S., Farina, D., Keller, T., & Dosen, S. S. (2017) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2017.2712287 · Cited by 92
Self-citationFeasibility of an Active Control Scheme for Above Knee Prostheses
Grimes, D. L., Flowers, W. C., & Donath, M. (1977) · Journal of Biomechanical Engineering · doi:10.1115/1.3426293 · Cited by 92
On prosthetic control: A regenerative agonist-antagonist myoneural interface
Srinivasan, S. S., Carty, M. J., Calvaresi, P. W., Clites, T. R., Maimon, B. E., Taylor, C. R., Zorzos, A. N., & Herr, H. (2017) · Science Robotics · doi:10.1126/scirobotics.aan2971 · Cited by 90
Ortiz-Catalan, M., Rouhani, F., Branemark, R., & Hakansson, B. (2015) · 2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2015.7318567 · Cited by 89
Self-citationDesign features of implants for direct skeletal attachment of limb prostheses
Pitkin, M. R. (2013) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.34606 · Cited by 88
Online mapping of EMG signals into kinematics by autoencoding
Vujaklija, I., Shalchyan, V., Kamavuako, E. N., Jiang, N., Marateb, H. R., & Farina, D. (2018) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-018-0363-1 · Cited by 87
Self-citationBayesian approaches to sensory integration for motor control
Berniker, M., & Kording, K. P. (2011) · Wiley Interdisciplinary Reviews Cognitive Science · doi:10.1002/wcs.125 · Cited by 86
Skin problems in amputees: a descriptive study
(2008) · doi:10.1111/j.1365-4632.2008.03604.x · Cited by 82
Percutaneous osseointegrated prostheses for amputees: Limb compensation in a 12-month ovine model
Shelton, T. J., Beck, J. P., Bloebaum, R. D., & Bachus, K. N. (2011) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2011.08.020 · Cited by 82
Effects of Locomotion Mode Recognition Errors on Volitional Control of Powered Above-Knee Prostheses
Zhang, F., Liu, M., & Huang, H. (2015) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2327230 · Cited by 82
Self-citationCipriani, C., Segil, J. L., Birdwell, J. A., & Weir, R. F. F. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2301234 · Cited by 81
Self-citationPeripheral nerve transfers change target muscle structure and function
Bergmeister, K. D., Aman, M., Muceli, S., Vujaklija, I., Manzano-Szalai, K., Unger, E., Byrne, R. A., Scheinecker, C., Riedl, O., Salminger, S., et al. (2019) · Science Advances · doi:10.1126/sciadv.aau2956 · Cited by 80
Self-citationContinuous Detection and Decoding of Dexterous Finger Flexions With Implantable MyoElectric Sensors
Baker, J. J., Scheme, E., Englehart, K., Hutchinson, D. T., & Greger, B. (2010) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2010.2047590 · Cited by 77
Cineplasty as a control input for externally powered prosthetic components.
Weir, R. F. F., Heckathorne, C. W., & Childress, D. S. (2001) · PubMed · Cited by 77
Self-citationSHEEP AS AN EXPERIMENTAL MODEL FOR BIOMATERIAL IMPLANT EVALUATION
Sartoretto, S. C., Uzeda, M. J., Miguel, F. B., Nascimento, J. R. B., Áscoli, F. O., & Calasans‐Maia, M. D. (2016) · Acta Ortopédica Brasileira · doi:10.1590/1413-785220162405161949 · Cited by 77
Edwards, A. L., Dawson, M. R. W., Hebert, J. S., Sherstan, C., Sutton, R. S., Chan, K. M., & Pilarski, P. M. (2015) · Prosthetics and Orthotics International · doi:10.1177/0309364615605373 · Cited by 77
The Evolution of Upper Limb Prosthetic Socket Design
(2008) · doi:10.1097/jpo.0b013e31817d2f08 · Cited by 74
Non-weight-bearing neural control of a powered transfemoral prosthesis
Hargrove, L. J., Simon, A. M., Lipschutz, R., Finucane, S. B., & Kuiken, T. A. (2013) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-10-62 · Cited by 73
Self-citationImplantable myoelectric sensors (IMES) for upper-extremity prosthesis control- preliminary work
Weir, R. F. F., Troyk, P. R., DeMichele, G. A., & Kuiken, T. (2004) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2003.1279658 · Cited by 72
Self-citationPerceptual Embodiment of Prosthetic Limbs by Transcutaneous Electrical Nerve Stimulation
Mulvey, M. R., Fawkner, H. J., Radford, H. E., & Johnson, M. I. (2011) · Neuromodulation Technology at the Neural Interface · doi:10.1111/j.1525-1403.2011.00408.x · Cited by 70
Frost, C. M., Ursu, D. C., Flattery, S. M., Nedic, A., Hassett, C. A., Moon, J. D., Buchanan, P. J., Brent Gillespie, R., Kung, T. A., Kemp, S. W. P., et al. (2018) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-018-0452-1 · Cited by 68 · cited 1×
“These individual groups of contracting muscle can then produce high-fidelity motor-control signals with favourable signal-to-noise ratios for the real-time control of a prosthesis 129–131 .”
BackgroundProportional EMG control of ankle plantar flexion in a powered transtibial prosthesis
Wang, J., Kannape, O. A., & Herr, H. M. (2013) · 2013 IEEE 13th International Conference on Rehabilitation Robotics (ICORR) · doi:10.1109/icorr.2013.6650391 · Cited by 67
Co‐production from proposal to paper
Hickey, G., Richards, T., & Sheehy, J. (2018) · Nature · doi:10.1038/d41586-018-06861-9 · Cited by 67
Game-Based Rehabilitation for Myoelectric Prosthesis Control
Prahm, C., Vujaklija, I., Kayali, F., Purgathofer, P., & Aszmann, O. C. (2017) · JMIR Serious Games · doi:10.2196/games.6026 · Cited by 67
Self-citationVirtual Grasping: Closed-Loop Force Control Using Electrotactile Feedback
Jorgovanovic, N., Dosen, S., Djozic, D. J., Krajoski, G., & Farina, D. (2014) · Computational and Mathematical Methods in Medicine · doi:10.1155/2014/120357 · Cited by 64
Self-citationPrahm, C., Kayali, F., Sturma, A., & Aszmann, O. C. (2018) · PM&R · doi:10.1016/j.pmrj.2018.09.027 · Cited by 64
Self-citationDe Nunzio, A. M., Dosen, S., Lemling, S., Markovic, M., Schweisfurth, M. A., Ge, N., Graimann, B., Falla, D., & Farina, D. (2017) · Experimental Brain Research · doi:10.1007/s00221-017-4991-7 · Cited by 62
Self-citationVu, P. P., Irwin, Z. T., Bullard, A. J., Ambani, S. W., Sando, I. C., Urbanchek, M. G., Cederna, P. S., & Chestek, C. A. (2018) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2017.2772961 · Cited by 61
Performance of above elbow body-powered prostheses in visually guided unconstrained motion tasks
Doeringer, J. A., & Hogan, N. (1995) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.387202 · Cited by 61
Compliant peripheral nerve interfaces.
Paggi, V., Akouissi, O., Micera, S., & Lacour, S. P. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/abcdbe · Cited by 60 · cited 1×
“Although long-term nerve implants are feasible 103,114,195,231–234 and promising for versatile clinical and home uses 96,235 , their wider clinical translation will require substantial developments regarding device stability, their integration into fully implantable systems, and the modularity of…”
BackgroundSelf-citationAugmented reality improves myoelectric prosthesis training
Anderson, F., & Bischof, W. F. (2014) · International Journal on Disability and Human Development · doi:10.1515/ijdhd-2014-0327 · Cited by 60
Risso, G., Valle, G., Iberite, F., Strauss, I., Stieglitz, T., Controzzi, M., Clemente, F., Granata, G., Rossini, P. M., Micera, S., et al. (2019) · Scientific Reports · doi:10.1038/s41598-019-43815-1 · Cited by 59
Self-citationMultichannel electrotactile feedback for simultaneous and proportional myoelectric control
Patel, G. K., Dosen, S., Castellini, C., & Farina, D. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/5/056015 · Cited by 58
Self-citationČvančara, P., Boretius, T., López-Álvarez, V. M., Maciejasz, P., Andreu, D., Raspopovic, S., Petrini, F., Micera, S., Granata, G., Fernandez, E., et al. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab9a9a · Cited by 58 · cited 1×
“Besides the inherent difficulty of artificially replicating the encoding of sensory feedback, apart from recent promising examples 44 , a common challenge for these interfaces remains achieving long-term stability 193 .”
BackgroundSelf-citationA wearable skin stretch device for haptic feedback
(2009) · doi:10.1109/whc.2009.4810850 · Cited by 58
Chen, C., Chai, G., Guo, W., Sheng, X., Farina, D., & Zhu, X. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aaf4c3 · Cited by 57
Self-citation(2013) · doi:10.1016/j.pmr.2013.09.012 · Cited by 57
Wheaton, L. A. (2017) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-017-0256-8 · Cited by 57
Motor Unit Characteristics after Targeted Muscle Reinnervation
Kapelner, T., Jiang, N., Holobar, A., Vujaklija, I., Roche, A. D., Farina, D., & Aszmann, O. C. (2016) · PLoS ONE · doi:10.1371/journal.pone.0149772 · Cited by 56
Self-citationUpper-Limb Prosthetic Myocontrol: Two Recommendations
Castellini, C., Bongers, R. M., Nowak, M., & van der Sluis, C. K. (2016) · Frontiers in Neuroscience · doi:10.3389/fnins.2015.00496 · Cited by 54
Fully Implantable Multi-Channel Measurement System for Acquisition of Muscle Activity
Lewis, S., Russold, M., Dietl, H., Ruff, R., Audi, J. M. C., Hoffmann, K.-P., Abu-Saleh, L., Schroeder, D., Krautschneider, W. H., Westendorff, S., et al. (2013) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2013.2253992 · Cited by 52 · cited 1×
“94 ; MIRA, ref.”
Self-citationBrain–machine interface: closer to therapeutic reality?
Courtine, G., Micera, S., DiGiovanna, J., & Millán, J. D. R. (2012) · The Lancet · doi:10.1016/s0140-6736(12)62164-3 · Cited by 52
Self-citationBergmeister, K. D., Vujaklija, I., Muceli, S., Sturma, A., Hruby, L. A., Prahm, C., Riedl, O., Salminger, S., Manzano-Szalai, K., Aman, M., et al. (2017) · Frontiers in Neuroscience · doi:10.3389/fnins.2017.00421 · Cited by 52
Self-citationFarina, D., Rehbaum, H., Holobar, A., Vujaklija, I., Jiang, N., Hofer, C., Salminger, S., van Vliet, H.-W., & Aszmann, O. C. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2306000 · Cited by 51
Self-citationMay, T., Ozden, I., Brush, B. R., Borton, D. A., Wagner, F. B., Agha, N. S., Sheinberg, D. L., & Nurmikko, A. V. (2014) · PLoS ONE · doi:10.1371/journal.pone.0114529 · Cited by 51
Decoding of grasping tasks from intraneural recordings in trans-radial amputee
Cracchiolo, M., Valle, G. D., Petrini, F. M., Strauss, I., Granata, G., Stieglitz, T., Rossini, P. M., Raspopović, S., Mazzoni, A., & Micera, S. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab8277 · Cited by 49
Self-citationPeng, J., Fey, N. P., Kuiken, T., & Hargrove, L. J. (2016) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2015.12.041 · Cited by 48
Self-citationCrouch, D. L., & Huang, H. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa61bc · Cited by 46
Self-citationLi, M., Zhang, D., Chen, Y., Chai, X., He, L., Chen, Y., Guo, J., & Sui, X. (2018) · Frontiers in Neuroscience · doi:10.3389/fnins.2018.00283 · Cited by 46
Vargas, L., Shin, H., Huang, H., Zhu, Y., & Hu, X. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab4d99 · Cited by 43
Self-citation
Research works printed but not linked: 1
- McDonnall, S., Hiatt, S., Crofts, B., Smith, C. & Merrill, D. Development of a wireless multichannel myoelectric implant for prosthesis control. In Proc. Myoelectric Control and Upper Limb Prosthesis Symposium (MEC 2017) 21 (2017).
Cited by
Manickam, P., Mariappan, S. A., Murugesan, S. M., Hansda, S., Kaushik, A., Shinde, R., & Thipperudraswamy, S. P. (2022) · Biosensors · doi:10.3390/bios12080562 · Cited by 637
“It should be diagnosed in the early stage and be monitored regularly.”
BackgroundFlexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics
Heng, W., Solomon, S., & Gao, W. (2022) · Advanced Materials · doi:10.1002/adma.202107902 · Cited by 609
Kong, L., Li, W., Zhang, T., Ma, H., Cao, Y., Wang, K., Zhou, Y., Shamim, A., Zheng, L., Wang, X., et al. (2024) · Advanced Materials · doi:10.1002/adma.202400333 · Cited by 227
Artificial intelligence meets medical robotics
Yip, M., Salcudean, S., Goldberg, K., Althoefer, K., Menciassi, A., Opfermann, J. D., Krieger, A., Swaminathan, K., Walsh, C. J., Huang, H. (., et al. (2023) · Science · doi:10.1126/science.adj3312 · Cited by 207
Self-citationWearable and Implantable Soft Robots
Yin, S., Yao, D. R., Song, Y., Heng, W., Ma, X., Han, H., & Gao, W. (2024) · Chemical Reviews · doi:10.1021/acs.chemrev.4c00513 · Cited by 173
Metadata
- Authors
- Farina, D., Vujaklija, I., Brånemark, R., Bull, A. M. J., Dietl, H., Graimann, B., Hargrove, L. J., Hoffmann, K.-P., Huang, H., Ingvarsson, T., Janusson, H. B., Kristjánsson, K., Kuiken, T., Micera, S., Stieglitz, T., Sturma, A., Tyler, D., Weir, R. F. F., & Aszmann, O. C.
- Affiliations
- Imperial College London (GB)
- Aalto University (FI)
- Sahlgrenska University Hospital (SE)
- Ottobock (Austria) (AT)
- Ottobock (Germany) (DE)
- Northwestern University (US)
- Fraunhofer Institute for Biomedical Engineering (DE)
- University of North Carolina at Chapel Hill (US)
- University of Iceland (IS)
- Össur (Iceland) (IS)
- Scuola Superiore Sant'Anna (IT)
- University of Freiburg (DE)
- Louis Stokes Cleveland VA Medical Center (US)
- VA Eastern Colorado Health Care System (US)
- Medical University of Vienna (AT)
- Corresponding author
- Farina, Dario
- ORCID
- Venue
- Nature Biomedical Engineering
- Published
- 2021-05-31
- Volume
- 7
- Issue
- 4
- Pages
- 473-485
- ISSN
- 2157-846X (ISSN-L)
- OpenAlex
- W3165882235
- Cited by
- 263
- References
- 251
- Citations by year
- 2026: 29 · 2025: 57 · 2024: 68 · 2023: 64 · 2022: 34 · 2021: 11
- FWCI
- 3.74
- Type
- journal article
- Language
- en
- Open access
- green
- research.aalto.fi
- Licence
- other-oa
- www.springernature.com/gp/researchers/text-and-data-mining (tdm)
- www.springernature.com/gp/researchers/text-and-data-mining (vor)
- Locations
- Nature Biomedical Engineering (publishedVersion)
- PubMed (publishedVersion)
- Aaltodoc (Aalto University) (submittedVersion, other-oa)
- Publikationsdatenbank der Fraunhofer-Gesellschaft (Fraunhofer-Gesellschaft) (submittedVersion)
- Infoscience (Ecole Polytechnique Fédérale de Lausanne) (submittedVersion, cc-by-nc-nd)
- Fraunhofer-Publica (Fraunhofer-Gesellschaft) (submittedVersion)
- Spiral (Imperial College London) (submittedVersion)
- CINECA IRIS Institutional Research Information System (Sant'Anna School of Advanced Studies) (submittedVersion)
- Funders
- U.S. Department of Veterans Affairs (I01 RX003355, I01 RX001334, IK6 RX003836)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Keywords
- bionic limbs, osseointegration, targeted muscle reinnervation, peripheral nerve stimulation, sensory feedback, neural interfaces, robotic prostheses, rehabilitation training, body ownership
- MeSH terms
- Artificial Limbs, Bionics, Electrodes, Extremities, Humans, Prosthesis Design
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
A second model labelled each claim on 2026-10-06 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›