Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 298

The DOI matches its Crossref record; 55 of the 55 references it cites were found in a registry or an index.

Enhanced tendon healing by a tough hydrogel with an adhesive side and high drug-loading capacity

Open access
Freedman, Benjamin R., Kuttler, Andreas, Beckmann, Nicolau, Nam, Sungmin, Kent, Daniel, Schuleit, Michael, Ramazani, Farshad, Accart, Nathalie, Rock, Anna, Li, Jianyu, Kurz, Markus, Fisch, Andreas, Ullrich, Thomas, Hast, Michael W., Tinguely, Yann, Weber, Eckhard, Mooney, David J.·2022·Nature Biomedical Engineering

Abstract

Hydrogels that provide mechanical support and sustainably release therapeutics have been used to treat tendon injuries. However, most hydrogels are insufficiently tough, release drugs in bursts, and require cell infiltration or suturing to integrate with surrounding tissue. Here we report that a hydrogel serving as a high-capacity drug depot and combining a dissipative tough matrix on one side and a chitosan adhesive surface on the other side supports tendon gliding and strong adhesion (larger than 1,000 J m −2 ) to tendon on opposite surfaces of the hydrogel, as we show with porcine and human tendon preparations during cyclic-friction loadings. The hydrogel is biocompatible, strongly adheres to patellar, supraspinatus and Achilles tendons of live rats, boosted healing and reduced scar formation in a rat model of Achilles-tendon rupture, and sustainably released the corticosteroid triamcinolone acetonide in a rat model of patellar tendon injury, reducing inflammation, modulating chemokine secretion, recruiting tendon stem and progenitor cells, and promoting macrophage polarization to the M2 phenotype. Hydrogels with ‘Janus’ surfaces and sustained-drug-release functionality could be designed for a range of biomedical applications. A hydrogel serving as a high-capacity drug depot and combining a dissipative tough matrix on one side and a tendon-adhesive surface on the other side boosts tissue healing in rat models of tendon rupture.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/s41551-021-00810-0

Cites

55 of 55 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 55 references

Cited by

See all 298

Metadata

Authors
Freedman, B. R., Kuttler, A., Beckmann, N., Nam, S., Kent, D., Schuleit, M., Ramazani, F., Accart, N., Rock, A., Li, J., Kurz, M., Fisch, A., Ullrich, T., Hast, M. W., Tinguely, Y., Weber, E., & Mooney, D. J.
Venue
Nature Biomedical Engineering
Published
2022-01-03
Volume
6
Issue
10
Pages
1167-1179
ISSN
2157-846X (ISSN-L)
OpenAlex
W4205263709
Cited by
298
References
55
FWCI
54.28
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Enhanced tendon healing by a tough hydrogel with an adhesive side and high drug-loading capacity. https://app.cochat.ai/papers/10.1038/s41551-021-00810-0
The paper
Freedman, B. R., Kuttler, A., Beckmann, N., Nam, S., Kent, D., Schuleit, M., Ramazani, F., Accart, N., Rock, A., Li, J., Kurz, M., Fisch, A., Ullrich, T., Hast, M. W., Tinguely, Y., Weber, E., & Mooney, D. J. (2022). Enhanced tendon healing by a tough hydrogel with an adhesive side and high drug-loading capacity. Nature Biomedical Engineering. https://doi.org/10.1038/s41551-021-00810-0

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.