The DOI matches its Crossref record; 61 of the 61 references it cites were found in a registry or an index.
A wireless patch for the monitoring of C-reactive protein in sweat
Open accessAbstract
The quantification of protein biomarkers in blood at picomolar-level sensitivity requires labour-intensive incubation and washing steps. Sensing proteins in sweat, which would allow for point-of-care monitoring, is hindered by the typically large interpersonal and intrapersonal variations in its composition. Here we report the design and performance of a wearable and wireless patch for the real-time electrochemical detection of the inflammatory biomarker C-reactive (CRP) protein in sweat. The device integrates iontophoretic sweat extraction, microfluidic channels for sweat sampling and for reagent routing and replacement, and a graphene-based sensor array for quantifying CRP (via an electrode functionalized with anti-CRP capture antibodies-conjugated gold nanoparticles), ionic strength, pH and temperature for the real-time calibration of the CRP sensor. In patients with chronic obstructive pulmonary disease, with active or past infections or who had heart failure, the elevated concentrations of CRP measured via the patch correlated well with the protein's levels in serum. Wearable biosensors for the real-time sensitive analysis of inflammatory proteins in sweat may facilitate the management of chronic diseases.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Javey group, Gao group and Wang group also focused on electrochemical biosensing of sweat using various wearable sweat patches for sweat rate [30], L-Dopa [138,139], and C-reactive protein [140], cortisol [141,142], ketone [143], glucose [144], and therapeutic drugs [145].”
From The emergence of AI-based wearable sensors for digital health technology: a review (2023) · cites this paper as [140]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis
Gao, W., Emaminejad, S., Nyein, H. Y. Y., Challa, S., Chen, K., Peck, A., Fahad, H. M., Ota, H., Shiraki, H., Kiriya, D., et al. (2016) · Nature · doi:10.1038/nature16521 · Cited by 5,087 · cited 2×
“Recent advances in flexible electronics and digital health have transformed conventional laboratory tests into remote wearable molecular sensing that enables real-time monitoring of physiological biomarkers 16–24 .”
BackgroundSelf-citationChronic inflammation in the etiology of disease across the life span
Furman, D., Campisi, J., Verdin, E., Carrera-Bastos, P., Targ, S., Franceschi, C., Ferrucci, L., Gilroy, D. W., Fasano, A., Miller, G. W., et al. (2019) · Nature Medicine · doi:10.1038/s41591-019-0675-0 · Cited by 4,915
Inflammageing: chronic inflammation in ageing, cardiovascular disease, and frailty
Ferrucci, L., & Fabbri, E. (2018) · Nature Reviews Cardiology · doi:10.1038/s41569-018-0064-2 · Cited by 3,690
Wearable biosensors for healthcare monitoring
Kim, J., Campbell, A. S., de Ávila, B. E.-F., & Wang, J. (2019) · Nature Biotechnology · doi:10.1038/s41587-019-0045-y · Cited by 3,373
Lee, H., Choi, T. K., Lee, Y. B., Cho, H. R., Ghaffari, R., Wang, L., Choi, H. J., Chung, T. D., Lu, N., Hyeon, T., et al. (2016) · Nature Nanotechnology · doi:10.1038/nnano.2016.38 · Cited by 1,802
Bariya, M., Nyein, H. Y. Y., & Javey, A. (2018) · Nature Electronics · doi:10.1038/s41928-018-0043-y · Cited by 1,486
Wearable and flexible electronics for continuous molecular monitoring
Yang, Y., & Gao, W. (2019) · Chemical Society Reviews · doi:10.1039/c7cs00730b · Cited by 1,315 · cited 1×
“17).”
Self-citationA soft, wearable microfluidic device for the capture, storage, and colorimetric sensing of sweat
Koh, A., Kang, D., Xue, Y., Lee, S., Pielak, R. M., Kim, J., Hwang, T., Min, S., Banks, A., Bastien, P., et al. (2016) · Science Translational Medicine · doi:10.1126/scitranslmed.aaf2593 · Cited by 1,308
A laser-engraved wearable sensor for sensitive detection of uric acid and tyrosine in sweat
Yang, Y., Song, Y., Bo, X., Min, J., Pak, O. S., Zhu, L., Wang, M., Tu, J., Kogan, A., Zhang, H., et al. (2020) · Nature Biotechnology · doi:10.1038/s41587-019-0321-x · Cited by 1,270
Self-citation
Cited by
Sorted by citations
The emergence of AI-based wearable sensors for digital health technology: a review
Shajari, S., Kuruvinashetti, K., Komeili, A., & Sundararaj, U. (2023) · Sensors · doi:10.3390/s23239498 · Cited by 535
Stretchable graphene–hydrogel interfaces for wearable and implantable bioelectronics
Lu, Y., Yang, G., Wang, S., Zhang, Y., Jian, Y., He, L., Yu, T., Luo, H., Kong, D., Xianyu, Y., et al. (2023) · Nature Electronics · doi:10.1038/s41928-023-01091-y · Cited by 461
Materials-Driven Soft Wearable Bioelectronics for Connected Healthcare
Gong, S. P., Yan, L., Yin, J., Levin, A., & Cheng, W. (2024) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00502 · Cited by 433
A physicochemical-sensing electronic skin for stress response monitoring
Xu, C., Song, Y., Sempionatto, J. R., Solomon, S. A., Yu, Y., Nyein, H. Y. Y., Tay, R. Y., Li, J., Heng, W., Min, J., et al. (2024) · Nature Electronics · doi:10.1038/s41928-023-01116-6 · Cited by 422
Self-citationWound management materials and technologies from bench to bedside and beyond
Wang, C., Sani, E. S., Shih, C.-D., Lim, C. T., Wang, J., Armstrong, D. G., & Gao, W. F. (2024) · Nature Reviews Materials · doi:10.1038/s41578-024-00693-y · Cited by 448
Self-citation
Metadata
- Authors
- Tu, J., Min, J., Song, Y., Xu, C., Li, J., Moore, J., Hanson, J., Hu, E., Parimon, T., Wang, T.-Y., Davoodi, E., Chou, T.-F., Chen, P., Hsu, J. J., Rossiter, H. B., & Gao, W.
- Affiliations
- California Institute of Technology (US)
- The Lundquist Institute (US)
- University of California, Los Angeles (US)
- Cedars-Sinai Medical Center (US)
- Corresponding author
- Gao, Wei
- ORCID
- Venue
- Nature Biomedical Engineering
- Published
- 2023-06-22
- Volume
- 7
- Issue
- 10
- Pages
- 1293-1306
- ISSN
- 2157-846X (ISSN-L)
- PMC
- PMC10592261
- OpenAlex
- W4381612623
- Cited by
- 395
- References
- 61
- Citations by year
- 2026: 99 · 2025: 171 · 2024: 103 · 2023: 22
- FWCI
- 29.34
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Licence
- Locations
- Nature Biomedical Engineering (publishedVersion)
- PubMed (publishedVersion)
- PubMed Central (acceptedVersion)
- eScholarship (California Digital Library) (submittedVersion)
- Funders
- American Heart Association (19TPA34850157)
- U.S. Department of Health & Human Services | National Institutes of Health (R21DK13266, T32EB027629, 1S10OD02001301)
- National Science Foundation (2145802)
- United States Department of Defense | United States Navy | Office of Naval Research (N00014-21-1-2483, N00014-21-1-2845)
- Tobacco-Related Disease Research Program (T31IP1666)
- Alfred P. Sloan Foundation
- Agency for Science, Technology and Research
- Cedars-Sinai Medical Center (Technology Ventures Internal Project)
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
- Physical Sciences › Engineering › Biomedical Engineering › Biosensors and Analytical Detection
- Keywords
- C-reactive protein, sweat monitoring, electrochemical biosensor, iontophoresis, anti-CRP antibody, gold nanoparticles, point-of-care monitoring, chronic obstructive pulmonary disease, inflammatory markers
- MeSH terms
- Wearable Electronic Devices, C-Reactive Protein, Gold, Humans, Monitoring, Physiologic, Sweat, Biomarkers, Metal Nanoparticles
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review