The DOI matches its Crossref record; 61 of the 61 references it cites were found in a registry or an index.
A wireless patch for the monitoring of C-reactive protein in sweat
Open accessAbstract
The quantification of protein biomarkers in blood at picomolar-level sensitivity requires labour-intensive incubation and washing steps. Sensing proteins in sweat, which would allow for point-of-care monitoring, is hindered by the typically large interpersonal and intrapersonal variations in its composition. Here we report the design and performance of a wearable and wireless patch for the real-time electrochemical detection of the inflammatory biomarker C-reactive (CRP) protein in sweat. The device integrates iontophoretic sweat extraction, microfluidic channels for sweat sampling and for reagent routing and replacement, and a graphene-based sensor array for quantifying CRP (via an electrode functionalized with anti-CRP capture antibodies-conjugated gold nanoparticles), ionic strength, pH and temperature for the real-time calibration of the CRP sensor. In patients with chronic obstructive pulmonary disease, with active or past infections or who had heart failure, the elevated concentrations of CRP measured via the patch correlated well with the protein's levels in serum. Wearable biosensors for the real-time sensitive analysis of inflammatory proteins in sweat may facilitate the management of chronic diseases.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Javey group, Gao group and Wang group also focused on electrochemical biosensing of sweat using various wearable sweat patches for sweat rate [30], L-Dopa [138,139], and C-reactive protein [140], cortisol [141,142], ketone [143], glucose [144], and therapeutic drugs [145].”
From The emergence of AI-based wearable sensors for digital health technology: a review (2023) · cites this paper as [140]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis
Gao, W., Emaminejad, S., Nyein, H. Y. Y., Challa, S., Chen, K., Peck, A., Fahad, H. M., Ota, H., Shiraki, H., Kiriya, D., et al. (2016) · Nature · doi:10.1038/nature16521 · Cited by 5,087 · cited 2×
“Recent advances in flexible electronics and digital health have transformed conventional laboratory tests into remote wearable molecular sensing that enables real-time monitoring of physiological biomarkers 16–24 .”
BackgroundSelf-citationChronic inflammation in the etiology of disease across the life span
Furman, D., Campisi, J., Verdin, E., Carrera-Bastos, P., Targ, S., Franceschi, C., Ferrucci, L., Gilroy, D. W., Fasano, A., Miller, G. W., et al. (2019) · Nature Medicine · doi:10.1038/s41591-019-0675-0 · Cited by 4,915
Inflammageing: chronic inflammation in ageing, cardiovascular disease, and frailty
Ferrucci, L., & Fabbri, E. (2018) · Nature Reviews Cardiology · doi:10.1038/s41569-018-0064-2 · Cited by 3,690
Wearable biosensors for healthcare monitoring
Kim, J., Campbell, A. S., de Ávila, B. E.-F., & Wang, J. (2019) · Nature Biotechnology · doi:10.1038/s41587-019-0045-y · Cited by 3,373
Lee, H., Choi, T. K., Lee, Y. B., Cho, H. R., Ghaffari, R., Wang, L., Choi, H. J., Chung, T. D., Lu, N., Hyeon, T., et al. (2016) · Nature Nanotechnology · doi:10.1038/nnano.2016.38 · Cited by 1,802
Bariya, M., Nyein, H. Y. Y., & Javey, A. (2018) · Nature Electronics · doi:10.1038/s41928-018-0043-y · Cited by 1,486
Wearable and flexible electronics for continuous molecular monitoring
Yang, Y., & Gao, W. (2019) · Chemical Society Reviews · doi:10.1039/c7cs00730b · Cited by 1,315 · cited 1×
“17).”
Self-citationA soft, wearable microfluidic device for the capture, storage, and colorimetric sensing of sweat
Koh, A., Kang, D., Xue, Y., Lee, S., Pielak, R. M., Kim, J., Hwang, T., Min, S., Banks, A., Bastien, P., et al. (2016) · Science Translational Medicine · doi:10.1126/scitranslmed.aaf2593 · Cited by 1,308
A laser-engraved wearable sensor for sensitive detection of uric acid and tyrosine in sweat
Yang, Y., Song, Y., Bo, X., Min, J., Pak, O. S., Zhu, L., Wang, M., Tu, J., Kogan, A., Zhang, H., et al. (2020) · Nature Biotechnology · doi:10.1038/s41587-019-0321-x · Cited by 1,270
Self-citationA wearable electrochemical biosensor for the monitoring of metabolites and nutrients
Wang, M., Yang, Y., Min, J., Song, Y., Tu, J., Mukasa, D., Ye, C., Xu, C., Heflin, N., McCune, J. S., et al. (2022) · Nature Biomedical Engineering · doi:10.1038/s41551-022-00916-z · Cited by 957
Self-citationEmaminejad, S., Gao, W., Wu, E., Davies, Z. A., Yin Yin Nyein, H., Challa, S., Ryan, S. P., Fahad, H. M., Chen, K., Shahpar, Z., et al. (2017) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1701740114 · Cited by 839
Self-citationBandodkar, A. J., Gutruf, P., Choi, J., Lee, K., Sekine, Y., Reeder, J. T., Jeang, W. J., Aranyosi, A. J., Lee, S. P., Model, J. B., et al. (2019) · Science Advances · doi:10.1126/sciadv.aav3294 · Cited by 761
Accessing analytes in biofluids for peripheral biochemical monitoring
Heikenfeld, J., Jajack, A., Feldman, B., Granger, S. W., Gaitonde, S., Begtrup, G., & Katchman, B. A. (2019) · Nature Biotechnology · doi:10.1038/s41587-019-0040-3 · Cited by 758
An epidermal patch for the simultaneous monitoring of haemodynamic and metabolic biomarkers
Sempionatto, J. R., Lin, M., Yin, L., De la paz, E., Pei, K., Sonsa-ard, T., de Loyola Silva, A. N., Khorshed, A. A., Zhang, F., Tostado, N., et al. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00685-1 · Cited by 658
Yu, Y., Nassar, J., Xu, C., Min, J., Yang, Y., Dai, A., Doshi, R., Huang, A., Song, Y., Gehlhar, R., et al. (2020) · Science Robotics · doi:10.1126/scirobotics.aaz7946 · Cited by 655
Self-citationParlak, O., Keene, S. T., Marais, A., Curto, V. F., & Salleo, A. (2018) · Science Advances · doi:10.1126/sciadv.aar2904 · Cited by 603 · cited 2×
“24).”
BackgroundIntegrated textile sensor patch for real-time and multiplex sweat analysis
He, W., Wang, C., Wang, H., Jian, M., Lu, W., Liang, X., Zhang, X., Yang, F., & Zhang, Y. (2019) · Science Advances · doi:10.1126/sciadv.aax0649 · Cited by 564
Amplification of Inflammation in Emphysema and its Association with Latent Adenoviral Infection
Retamales, I., Elliott, W. M., Meshi, B., Coxson, H. O., Paré, P. D., Sciurba, F. C., Rogers, R. M., Hayashi, S., & Hogg, J. C. (2001) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.164.3.2007149 · Cited by 523
Torrente-Rodríguez, R. M., Lukas, H., Tu, J., Min, J., Yang, Y., Xu, C., Rossiter, H. B., & Gao, W. F. (2020) · Matter · doi:10.1016/j.matt.2020.09.027 · Cited by 489
Self-citationInvestigation of Cortisol Dynamics in Human Sweat Using a Graphene-Based Wireless mHealth System
Torrente-Rodríguez, R. M., Tu, J., Yang, Y., Min, J., Wang, M., Song, Y., Yu, Y., Xu, C., Ye, C., IsHak, W. W., et al. (2020) · Matter · doi:10.1016/j.matt.2020.01.021 · Cited by 479
Self-citationResolution of chronic inflammatory disease: universal and tissue-specific concepts
Schett, G. A., & Neurath, M. F. (2018) · Nature Communications · doi:10.1038/s41467-018-05800-6 · Cited by 441
C-reactive protein in patients with COPD, control smokers and non-smokers
Pinto-Plata, V. (2005) · Thorax · doi:10.1136/thx.2005.042200 · Cited by 433
Inflammation: Mechanisms, Costs, and Natural Variation
Ashley, N. T., Weil, Z. M., & Nelson, R. J. (2012) · Annual Review of Ecology Evolution and Systematics · doi:10.1146/annurev-ecolsys-040212-092530 · Cited by 430
Ridker, P. M. (2016) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2015.11.037 · Cited by 414
Wearable aptamer-field-effect transistor sensing system for noninvasive cortisol monitoring
Wang, B., Zhao, C., Wang, Z., Yang, K.-A., Cheng, X., Liu, W., Yu, W., Lin, S., Zhao, Y., Cheung, K. M., et al. (2022) · Science Advances · doi:10.1126/sciadv.abk0967 · Cited by 411
Simmonds, S. J., Cuijpers, I., Heymans, S. R. B., & Jones, E. A. V. (2020) · Cells · doi:10.3390/cells9010242 · Cited by 399
Wearable Sensors for Biochemical Sweat Analysis
Bandodkar, A. J., Jeang, W. J., Ghaffari, R., & Rogers, J. A. (2019) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-061318-114910 · Cited by 387
All-printed soft human-machine interface for robotic physicochemical sensing
Yu, Y., Li, J., Solomon, S. A., Min, J., Tu, J., Guo, W. H., Xu, C., Song, Y., & Gao, W. F. (2022) · Science Robotics · doi:10.1126/scirobotics.abn0495 · Cited by 379
Self-citationThe Era of Digital Health: A Review of Portable and Wearable Affinity Biosensors
Tu, J., Torrente-Rodríguez, R. M., Wang, M., & Gao, W. F. (2019) · Advanced Functional Materials · doi:10.1002/adfm.201906713 · Cited by 366
Self-citationC-reactive protein: A critical review
Young, B., Gleeson, M., & Cripps, A. W. (1991) · Pathology · doi:10.3109/00313029109060809 · Cited by 341
A flexible multiplexed immunosensor for point-of-care in situ wound monitoring
Gao, Y., Nguyen, D. T., Yeo, T., Lim, S. B., Tan, W. X., Madden, L. E., Jin, L., Long, J. Y. K., Aloweni, F. B. A. B., Liew, Y. J. A., et al. (2021) · Science Advances · doi:10.1126/sciadv.abg9614 · Cited by 297
On-Site Therapeutic Drug Monitoring
Ates, H. C., Roberts, J. A., Lipman, J., Cass, A. E. G., Urban, G. A., & Dincer, C. (2020) · Trends in biotechnology · doi:10.1016/j.tibtech.2020.03.001 · Cited by 267
Lactate Biosensing for Reliable On-Body Sweat Analysis
Xuan, X., Pérez‐Ràfols, C., Chen, C., Cuartero, M., & Crespo, G. A. (2021) · ACS Sensors · doi:10.1021/acssensors.1c01009 · Cited by 254
Continuous Opioid Monitoring along with Nerve Agents on a Wearable Microneedle Sensor Array
Mishra, R. K., Goud, K. Y., Li, Z., Moonla, C., Mohamed, M. A., Tehrani, F., Teymourian, H., & Wang, J. (2020) · Journal of the American Chemical Society · doi:10.1021/jacs.0c01883 · Cited by 239
Economic Burden of COPD in the Presence of Comorbidities
Mannino, D. M., Higuchi, K., Yu, T., Zhou, H., Li, Y., Tian, H., & Suh, K. (2015) · CHEST Journal · doi:10.1378/chest.14-2434 · Cited by 209
Prins, B. P., Abbasi, A., Wong, A., Vaez, A., Nolte, I., Franceschini, N., Stuart, P. E., Guterriez Achury, J., Mistry, V., Bradfield, J. P., et al. (2016) · PLOS Medicine · doi:10.1371/journal.pmed.1001976 · Cited by 199
Zhong, B., Jiang, K., Wang, L., & Shen, G. (2021) · Advanced Science · doi:10.1002/advs.202103257 · Cited by 170
Systemic Inflammation Predicts All-Cause Mortality: A Glasgow Inflammation Outcome Study
Proctor, M. J., McMillan, D. C., Horgan, P. G., Fletcher, C. D., Talwar, D., & Morrison, D. S. (2015) · PLOS ONE · doi:10.1371/journal.pone.0116206 · Cited by 168 · cited 1×
“10 and 11).”
A wearable sensor for the detection of sodium and potassium in human sweat during exercise
Pirovano, P., Dorrian, M., Shinde, A., Donohoe, A., Brady, A. J., Moyna, N. M., Wallace, G. G., Diamond, D., & McCaul, M. V. (2020) · Talanta · doi:10.1016/j.talanta.2020.121145 · Cited by 164
Lin, H., Tan, J., Zhu, J., Lin, S., Zhao, Y., Yu, W., Hojaiji, H., Wang, B., Yang, S., Cheng, X., et al. (2020) · Nature Communications · doi:10.1038/s41467-020-18238-6 · Cited by 163
Wearable Cortisol Aptasensor for Simple and Rapid Real-Time Monitoring
An, J. E., Kim, K. H., Park, S. J., Seo, S. E., Kim, J., Ha, S., Bae, J., & Kwon, O. S. (2022) · ACS Sensors · doi:10.1021/acssensors.1c01734 · Cited by 147
Soft, skin-interfaced sweat stickers for cystic fibrosis diagnosis and management
Ray, T. R., Ivanovic, M., Curtis, P. M., Franklin, D., Guventurk, K., Jeang, W. J., Chafetz, J., Gaertner, H., Young, G. B., Rebollo, S., et al. (2021) · Science Translational Medicine · doi:10.1126/scitranslmed.abd8109 · Cited by 138
C-reactive protein as a predictor of disease in smokers and former smokers: a review
Tonstad, S., & Cowan, J. L. (2009) · International Journal of Clinical Practice · doi:10.1111/j.1742-1241.2009.02179.x · Cited by 111
Yang, X., Xu, M., Qiu, W., Chen, X., Deng, M. X., Zhang, J., Iwaï, H., Watanabe, E., & Chen, H. (2011) · Journal of Materials Chemistry · doi:10.1039/c1jm10697j · Cited by 102
Garcia-Cordero, E., Bellando, F., Zhang, J., Wildhaber, F., Longo, J., Guérin, H., & Ionescu, A. M. (2018) · ACS Nano · doi:10.1021/acsnano.8b07413 · Cited by 92
Lakhani, I., Wong, M. V., Hung, J. K. F., Gong, M., Waleed, K. B., Xia, Y., Lee, S., Roever, L., Liu, T., Tse, G., et al. (2020) · Heart Failure Reviews · doi:10.1007/s10741-020-09927-x · Cited by 88
Electrolyte and acid-base disorders in inflammatory bowel disease.
Barkas, F., Liberopoulos, E. N., Kei, A. A., & Elisaf, M. (2013) · Europe PMC (PubMed Central) · Cited by 66
Butler, J., Djatche, L. M., Sawhney, B., Chakladar, S., Yang, L., Brady, J. E., & Yang, M. (2020) · Advances in Therapy · doi:10.1007/s12325-020-01456-1 · Cited by 65
Inflammatory Markers and Risk of Heart Failure With Reduced to Preserved Ejection Fraction
Albar, Z., Albakri, M. M., Hajjari, J., Karnib, M., Janus, S. E., & Al-Kindi, S. G. (2022) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2021.11.045 · Cited by 65
Guo, S., Mao, X., & Ming, L. (2018) · Respiratory Research · doi:10.1186/s12931-018-0877-x · Cited by 61
Harshman, S. W., Pitsch, R. L., Smith, Z. K., O’Connor, M. L., Geier, B. A., Qualley, A. V., Schaeublin, N. M., Fischer, M. V., Eckerle, J. J., Strang, A. J., et al. (2018) · PLOS ONE · doi:10.1371/journal.pone.0203133 · Cited by 51
Wylezinski, L. S., Gray, J. D., Polk, J. B., Harmata, A. J., & Spurlock, C. F. (2019) · Journal of Clinical Medicine · doi:10.3390/jcm8040493 · Cited by 50
Jagannath, B., Pali, M. L., Lin, K., Sankhala, D., Naraghi, P., Muthukumar, S., & Prasad, S. (2022) · Advanced Materials Technologies · doi:10.1002/admt.202101356 · Cited by 39
Biosensor development for C-reactive protein detection: A review
Balayan, S., Chauhan, N., Rosario, W., & Jain, U. (2022) · Applied Surface Science Advances · doi:10.1016/j.apsadv.2022.100343 · Cited by 39
Sequential C-reactive protein measurements in patients with serious infections: does it help?
Lobo, S. M. (2012) · Critical Care · doi:10.1186/cc11347 · Cited by 35
The Evolving Role of Proteins in Wearable Sweat Biosensors
Saldanha, D. J., Cai, A., & Courchesne, N. D. (2021) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.1c00699 · Cited by 34
Zhuang, G., Katakura, Y., Ōmasa, T., Kishimoto, M., & Suga, K.-I. (2001) · Journal of Bioscience and Bioengineering · doi:10.1016/s1389-1723(01)80235-8 · Cited by 27
Out-of-clinic measurement of sweat chloride using a wearable sensor during low-intensity exercise
Choi, D., Kitchen, G. B., Jennings, M. T., Cutting, G. R., & Searson, P. C. (2020) · npj Digital Medicine · doi:10.1038/s41746-020-0257-z · Cited by 24
Majewski, S., Pietrzak, A., Tworek, D., Szewczyk, K., Kumor‐Kisielewska, A., Kurmanowska, Z., Górski, P., Zalewska-Janowska, A. M., & Piotrowski, W. J. (2017) · International Journal of COPD · doi:10.2147/copd.s141805 · Cited by 16
Xin, Y., Zhou, J., Nesser, H., & Gilles Lubineau, A. (2022) · Advanced Electronic Materials · doi:10.1002/aelm.202200534 · Cited by 11
Cited by
Sorted by citations
The emergence of AI-based wearable sensors for digital health technology: a review
Shajari, S., Kuruvinashetti, K., Komeili, A., & Sundararaj, U. (2023) · Sensors · doi:10.3390/s23239498 · Cited by 535
Stretchable graphene–hydrogel interfaces for wearable and implantable bioelectronics
Lu, Y., Yang, G., Wang, S., Zhang, Y., Jian, Y., He, L., Yu, T., Luo, H., Kong, D., Xianyu, Y., et al. (2023) · Nature Electronics · doi:10.1038/s41928-023-01091-y · Cited by 461
Materials-Driven Soft Wearable Bioelectronics for Connected Healthcare
Gong, S. P., Yan, L., Yin, J., Levin, A., & Cheng, W. (2024) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00502 · Cited by 433
A physicochemical-sensing electronic skin for stress response monitoring
Xu, C., Song, Y., Sempionatto, J. R., Solomon, S. A., Yu, Y., Nyein, H. Y. Y., Tay, R. Y., Li, J., Heng, W., Min, J., et al. (2024) · Nature Electronics · doi:10.1038/s41928-023-01116-6 · Cited by 422
Self-citationWound management materials and technologies from bench to bedside and beyond
Wang, C., Sani, E. S., Shih, C.-D., Lim, C. T., Wang, J., Armstrong, D. G., & Gao, W. F. (2024) · Nature Reviews Materials · doi:10.1038/s41578-024-00693-y · Cited by 448
Self-citation
Metadata
- Authors
- Tu, J., Min, J., Song, Y., Xu, C., Li, J., Moore, J., Hanson, J., Hu, E., Parimon, T., Wang, T.-Y., Davoodi, E., Chou, T.-F., Chen, P., Hsu, J. J., Rossiter, H. B., & Gao, W.
- Affiliations
- California Institute of Technology (US)
- The Lundquist Institute (US)
- University of California, Los Angeles (US)
- Cedars-Sinai Medical Center (US)
- Corresponding author
- Gao, Wei
- ORCID
- Venue
- Nature Biomedical Engineering
- Published
- 2023-06-22
- Volume
- 7
- Issue
- 10
- Pages
- 1293-1306
- ISSN
- 2157-846X (ISSN-L)
- PMC
- PMC10592261
- OpenAlex
- W4381612623
- Cited by
- 395
- References
- 61
- Citations by year
- 2026: 99 · 2025: 171 · 2024: 103 · 2023: 22
- FWCI
- 29.34
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Licence
- Locations
- Nature Biomedical Engineering (publishedVersion)
- PubMed (publishedVersion)
- PubMed Central (acceptedVersion)
- eScholarship (California Digital Library) (submittedVersion)
- Funders
- American Heart Association (19TPA34850157)
- U.S. Department of Health & Human Services | National Institutes of Health (R21DK13266, T32EB027629, 1S10OD02001301)
- National Science Foundation (2145802)
- United States Department of Defense | United States Navy | Office of Naval Research (N00014-21-1-2483, N00014-21-1-2845)
- Tobacco-Related Disease Research Program (T31IP1666)
- Alfred P. Sloan Foundation
- Agency for Science, Technology and Research
- Cedars-Sinai Medical Center (Technology Ventures Internal Project)
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
- Physical Sciences › Engineering › Biomedical Engineering › Biosensors and Analytical Detection
- Keywords
- C-reactive protein, sweat monitoring, electrochemical biosensor, iontophoresis, anti-CRP antibody, gold nanoparticles, point-of-care monitoring, chronic obstructive pulmonary disease, inflammatory markers
- MeSH terms
- Wearable Electronic Devices, C-Reactive Protein, Gold, Humans, Monitoring, Physiologic, Sweat, Biomarkers, Metal Nanoparticles
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review