Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 337

The DOI matches its Crossref record; 60 of the 60 references it cites were found in a registry or an index.

Shortwave infrared polymethine fluorophores matched to excitation lasers enable non-invasive, multicolour in vivo imaging in real time

Open access
Cosco, Emily D., Spearman, Anthony L., Ramakrishnan, Shyam, Lingg, Jakob G. P., Saccomano, Mara, Pengshung, Monica, Arús, Bernardo A., Wong, Kelly C. Y., Glasl, Sarah, Ntziachristos, Vasilis, Warmer, Martin, McLaughlin, Ryan R., Bruns, Oliver T., Sletten, Ellen M.·2020·Nature Chemistry

Abstract

High-resolution, multiplexed experiments are a staple in cellular imaging. Analogous experiments in animals are challenging, however, due to substantial scattering and autofluorescence in tissue at visible (350–700 nm) and near-infrared (700–1,000 nm) wavelengths. Here, we enable real-time, non-invasive multicolour imaging experiments in animals through the design of optical contrast agents for the shortwave infrared (SWIR, 1,000–2,000 nm) region and complementary advances in imaging technologies. We developed tunable, SWIR-emissive flavylium polymethine dyes and established relationships between structure and photophysical properties for this class of bright SWIR contrast agents. In parallel, we designed an imaging system with variable near-infrared/SWIR excitation and single-channel detection, facilitating video-rate multicolour SWIR imaging for optically guided surgery and imaging of awake and moving mice with multiplexed detection. Optimized dyes matched to 980 nm and 1,064 nm lasers, combined with the clinically approved indocyanine green, enabled real-time, three-colour imaging with high temporal and spatial resolutions. Conducting high-resolution, multiplexed imaging in living mammals is challenging because of considerable scattering and autofluorescence in tissue at visible and near-infrared wavelengths. Now, real-time, non-invasive multicolour imaging experiments in live animals have been achieved through the design of optical contrast agents for the shortwave infrared (SWIR, 1,000–2,000 nm) region and the introduction of excitation multiplexing with single-channel SWIR detection.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/s41557-020-00554-5

Cites

60 of 60 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 60 references

Cited by

See all 337

Metadata

Authors
Cosco, E. D., Spearman, A. L., Ramakrishnan, S., Lingg, J. G. P., Saccomano, M., Pengshung, M., Arús, B. A., Wong, K. C. Y., Glasl, S., Ntziachristos, V., Warmer, M., McLaughlin, R. R., Bruns, O. T., & Sletten, E. M.
Venue
Nature Chemistry
Published
2020-10-19
Volume
12
Issue
12
Pages
1123-1130
ISSN
  • 1755-4330 (ISSN-L)
  • 1755-4349
OpenAlex
W3093062920
Cited by
337
References
60
FWCI
17.71
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Shortwave infrared polymethine fluorophores matched to excitation lasers enable non-invasive, multicolour in vivo imaging in real time. https://app.cochat.ai/papers/10.1038/s41557-020-00554-5
The paper
Cosco, E. D., Spearman, A. L., Ramakrishnan, S., Lingg, J. G. P., Saccomano, M., Pengshung, M., Arús, B. A., Wong, K. C. Y., Glasl, S., Ntziachristos, V., Warmer, M., McLaughlin, R. R., Bruns, O. T., & Sletten, E. M. (2020). Shortwave infrared polymethine fluorophores matched to excitation lasers enable non-invasive, multicolour in vivo imaging in real time. Nature Chemistry. https://doi.org/10.1038/s41557-020-00554-5

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.