Clinical quantitative cardiac imaging for the assessment of myocardial ischaemia
Open accessThe DOI matches its Crossref record; 135 of the 135 references it cites were found in a registry or an index.
Abstract
Cardiac imaging has a pivotal role in the prevention, diagnosis and treatment of ischaemic heart disease. SPECT is most commonly used for clinical myocardial perfusion imaging, whereas PET is the clinical reference standard for the quantification of myocardial perfusion. MRI does not involve exposure to ionizing radiation, similar to echocardiography, which can be performed at the bedside. CT perfusion imaging is not frequently used but CT offers coronary angiography data, and invasive catheter-based methods can measure coronary flow and pressure. Technical improvements to the quantification of pathophysiological parameters of myocardial ischaemia can be achieved. Clinical consensus recommendations on the appropriateness of each technique were derived following a European quantitative cardiac imaging meeting and using a real-time Delphi process. SPECT using new detectors allows the quantification of myocardial blood flow and is now also suited to patients with a high BMI. PET is well suited to patients with multivessel disease to confirm or exclude balanced ischaemia. MRI allows the evaluation of patients with complex disease who would benefit from imaging of function and fibrosis in addition to perfusion. Echocardiography remains the preferred technique for assessing ischaemia in bedside situations, whereas CT has the greatest value for combined quantification of stenosis and characterization of atherosclerosis in relation to myocardial ischaemia. In patients with a high probability of needing invasive treatment, invasive coronary flow and pressure measurement is well suited to guide treatment decisions. In this Consensus Statement, we summarize the strengths and weaknesses as well as the future technological potential of each imaging modality.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
1 retracted
Liu, A., Wijesurendra, R. S., Liu, J. M., Greiser, A., Jerosch‐Herold, M., Forfar, J. C., Channon, K. M., Piechnik, S. K., Neubauer, S., Kharbanda, R. K., et al. (2018) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2017.11.071 · Cited by 78
Retracted2019 ESC Guidelines for the diagnosis and management of chronic coronary syndromes
Knuuti, J., Wijns, W., Saraste, A., Capodanno, D., Barbato, E., Funck-Brentano, C., Prescott, E., Storey, R. F., Deaton, C., Cuisset, T., et al. (2020) · European Heart Journal · doi:10.1093/eurheartj/ehz425 · Cited by 7,166
2013 ESC guidelines on the management of stable coronary artery disease
Task Force Members, Montalescot, G., Sechtem, U., Achenbach, S., Andreotti, F., Arden, C., Budaj, A., Bugiardini, R., Crea, F., Cuisset, T., et al. (2013) · European Heart Journal · doi:10.1093/eurheartj/eht296 · Cited by 4,510
Self-citationFihn, S. D., Gardin, J. M., Abrams, J., Berra, K., Blankenship, J. C., Dallas, A. P., Douglas, P. S., Foody, J. M., Gerber, T. C., Hinderliter, A. L., et al. (2012) · Circulation · doi:10.1161/cir.0b013e3182776f83 · Cited by 2,410
Image reconstruction by domain-transform manifold learning
Zhu, B., Liu, J. Z., Cauley, S. F., Rosen, B. R., & Rosen, M. S. (2018) · Nature · doi:10.1038/nature25988 · Cited by 1,694
Low Diagnostic Yield of Elective Coronary Angiography
Patel, M. R., Peterson, E. D., Dai, D., Brennan, J. M., Redberg, R. F., Anderson, H. V., Brindis, R. G., & Douglas, P. S. (2010) · New England Journal of Medicine · doi:10.1056/nejmoa0907272 · Cited by 1,665
Wei, K., Jayaweera, A. R., Firoozan, S., Linka, A., Skyba, D. M., & Kaul, S. (1998) · Circulation · doi:10.1161/01.cir.97.5.473 · Cited by 1,616
Fihn, S. D., Gardin, J. M., Abrams, J., Berra, K., Blankenship, J. C., Dallas, A. P., Douglas, P. S., Foody, J. M., Gerber, T. C., Hinderliter, A. L., et al. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.07.013 · Cited by 1,555
Taylor, C. A., Fonte, T. A., & Min, J. K. (2013) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.11.083 · Cited by 1,208
Greenwood, J. P., Maredia, N., Younger, J. F., Brown, J. M., Nixon, J., Everett, C. C., Bijsterveld, P., Ridgway, J. P., Radjenovic, A., Dickinson, C. J., et al. (2012) · The Lancet · doi:10.1016/s0140-6736(11)61335-4 · Cited by 1,114
Instantaneous Wave-free Ratio versus Fractional Flow Reserve to Guide PCI
Götberg, M., Christiansen, E. H., Gudmundsdottir, I. J., Sandhall, L., Danielewicz, M., Jakobsen, L., Olsson, S.-E., Öhagen, P., Olsson, H., Omerovic, E., et al. (2017) · New England Journal of Medicine · doi:10.1056/nejmoa1616540 · Cited by 985
Use of the Instantaneous Wave-free Ratio or Fractional Flow Reserve in PCI
Davies, J. E., Sen, S., Dehbi, H.-M., Al-Lamee, R., Petraco, R., Nijjer, S. S., Bhindi, R., Lehman, S. J., Walters, D., Sapontis, J., et al. (2017) · New England Journal of Medicine · doi:10.1056/nejmoa1700445 · Cited by 979
Self-citationRelation between Myocardial Blood Flow and the Severity of Coronary-Artery Stenosis
Uren, N. G., Melin, J. A., De Bruyne, B., Wijns, W., Baudhuin, T., & Camici, P. G. (1994) · New England Journal of Medicine · doi:10.1056/nejm199406233302503 · Cited by 881
Five-Year Outcomes with PCI Guided by Fractional Flow Reserve
Xaplanteris, P., Fournier, S., Pijls, N. H. J., Fearon, W. F., Barbato, E., Tonino, P. A. L., Engstrøm, T., Kääb, S., Dambrink, J.-H., Rioufol, G., et al. (2018) · New England Journal of Medicine · doi:10.1056/nejmoa1803538 · Cited by 866
aLow-dose CT via convolutional neural network
Chen, H., Zhang, Y., Zhang, W., Liao, P., Li, K., Zhou, J., & Wang, G. (2017) · Biomedical Optics Express · doi:10.1364/boe.8.000679 · Cited by 755
Prognostic value of gated myocardial perfusion SPECT
Shaw, L. J., & Iskandrian, A. E. (2004) · Journal of Nuclear Cardiology · doi:10.1016/j.nuclcard.2003.12.004 · Cited by 661
van Nunen, L. X., Zimmermann, F. M., Tonino, P. A. L., Barbato, E., Baumbach, A., Engstrøm, T., Klauss, V., MacCarthy, P. A., Manoharan, G., Oldroyd, K. G., et al. (2015) · The Lancet · doi:10.1016/s0140-6736(15)00057-4 · Cited by 624
Long-Term Prognostic Value of 13N-Ammonia Myocardial Perfusion Positron Emission Tomography
Herzog, B. A., Husmann, L., Valenta, I., Gaemperli, O., Siegrist, P. T., Tay, F. M., Burkhard, N., Wyss, C. A., & Kaufmann, P. A. (2009) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.02.069 · Cited by 616
Ziadi, M. C., deKemp, R. A., Williams, K. A., Guo, A., Chow, B. J. W., Renaud, J. M., Ruddy, T. D., Sarveswaran, N., Tee, R. E., & Beanlands, R. S. B. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.01.065 · Cited by 606
Anatomic Versus Physiologic Assessment of Coronary Artery Disease
Gould, K. L., Johnson, N. P., Bateman, T. M., Beanlands, R. S., Bengel, F. M., Bober, R., Camici, P. G., Cerqueira, M. D., Chow, B. J. W., Di Carli, M. F., et al. (2013) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2013.07.076 · Cited by 573
Self-citationCoronary microvascular dysfunction: mechanisms and functional assessment
Camici, P. G., d'Amati, G., & Rimoldi, O. (2015) · Nature Reviews Cardiology · doi:10.1038/nrcardio.2014.160 · Cited by 498
Taqueti, V. R., Hachamovitch, R., Murthy, V. L., Naya, M., Foster, C. R., Hainer, J., Dorbala, S., Blankstein, R., & Di Carli, M. F. (2015) · Circulation · doi:10.1161/circulationaha.114.011939 · Cited by 497
Magnetic Resonance Perfusion or Fractional Flow Reserve in Coronary Disease
Nagel, E., Greenwood, J. P., McCann, G. P., Bettencourt, N., Shah, A. M., Hussain, S. T., Perera, D., Plein, S., Bucciarelli-Ducci, C., Paul, M., et al. (2019) · New England Journal of Medicine · doi:10.1056/nejmoa1716734 · Cited by 484
Danad, I., Raijmakers, P. G., Driessen, R. S., Leipsic, J., Raju, R., Naoum, C., Knuuti, J., Mäki, M., Underwood, R. S., Min, J. K., et al. (2017) · JAMA Cardiology · doi:10.1001/jamacardio.2017.2471 · Cited by 475
Self-citationRochitte, C. E., George, R. T., Chen, M. Y., Arbab‐Zadeh, A., Dewey, M., Miller, J. M., Niinuma, H., Yoshioka, K., Kitagawa, K., Nakamori, S., et al. (2013) · European Heart Journal · doi:10.1093/eurheartj/eht488 · Cited by 462
Self-citationJaarsma, C., Leiner, T., Bekkers, S. C., Crijns, H. J., Wildberger, J. E., Nagel, E., Nelemans, P. J., & Schalla, S. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.12.040 · Cited by 456
Schwitter, J., Wacker, C. M., Wilke, N., Al-Saadi, N., Sauer, E., Huettle, K., Schönberg, S. O., Luchner, A., Strohm, O., Ahlstrom, H., et al. (2013) · European Heart Journal · doi:10.1093/eurheartj/ehs022 · Cited by 456
Porter, T. R., Mulvagh, S. L., Abdelmoneim, S. S., Becher, H., Belcik, J. T., Bierig, M., Choy, J., Gaibazzi, N., Gillam, L. D., Janardhanan, R., et al. (2018) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2017.11.013 · Cited by 432
Self-citationTakx, R. A. P., Blomberg, B. A., Aidi, H. E., Habets, J., de Jong, P. A., Nagel, E., Hoffmann, U., & Leiner, T. (2015) · Circulation: Cardiovascular Imaging · doi:10.1161/circimaging.114.002666 · Cited by 427
Itu, L., Rapaka, S., Passerini, T., Georgescu, B., Schwemmer, C., Schoebinger, M., Flohr, T., Sharma, P., & Comaniciu, D. (2016) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00752.2015 · Cited by 406
Comprehensive plaque assessment by coronary CT angiography
Maurovich-Horvat, P., Ferencik, M., Voros, S., Merkely, B., & Hoffmann, U. (2014) · Nature Reviews Cardiology · doi:10.1038/nrcardio.2014.60 · Cited by 381
Self-citationvan de Hoef, T. P., van Lavieren, M. A., Damman, P., Delewi, R., Piek, M. A., Chamuleau, S. A. J., Voskuil, M., Henriques, J. P. S., Koch, K. T., de Winter, R. J., et al. (2014) · Circulation: Cardiovascular Interventions · doi:10.1161/circinterventions.113.001049 · Cited by 372
Self-citationHeterogeneity of resting and hyperemic myocardial blood flow in healthy humans
Chareonthaitawee, P. (2001) · Cardiovascular Research · doi:10.1016/s0008-6363(01)00202-4 · Cited by 366
Acute myocardial infarction with no obstructive coronary atherosclerosis: mechanisms and management
Niccoli, G., Scalone, G., & Crea, F. (2015) · European Heart Journal · doi:10.1093/eurheartj/ehu469 · Cited by 365
First-pass cardiac perfusion: evaluation with ultrafast MR imaging.
Atkinson, D. J., Burstein, D., & Edelman, R. R. (1990) · Radiology · doi:10.1148/radiology.174.3.2305058 · Cited by 359
Montalescot, G., Rangé, G., Belle, L., Pouillot, C., Boueri, Z., Cayla, G., BELLE, E. V., Silvain, J., Vicaut, É., & Collet, J. (2013) · European Heart Journal · doi:10.1093/eurheartj/eht310.p4876 · Cited by 349
Danad, I., Szymonifka, J., Twisk, J. W. R., Norgaard, B. L., Zarins, C. K., Knaapen, P., & Min, J. K. (2016) · European Heart Journal · doi:10.1093/eurheartj/ehw095 · Cited by 335
Self-citationDanad, I., Uusitalo, V., Kero, T., Saraste, A., Raijmakers, P. G., Lammertsma, A. A., Heymans, M. W., Kajander, S. A., Pietilä, M., James, S., et al. (2014) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2014.05.069 · Cited by 330
Self-citationKellman, P., Hansen, M. S., Nielles-Vallespin, S., Nickander, J., Themudo, R., Ugander, M., & Xue, H. (2016) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-017-0355-5 · Cited by 314
Bocher, M., Blevis, I. M., Tsukerman, L., Shrem, Y., Kovalski, G., & Volokh, L. (2010) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-010-1488-z · Cited by 303
Safety of Magnetic Resonance Imaging in Patients with Cardiac Devices
Nazarian, S., Hansford, R., Rahsepar, A. A., Weltin, V., McVeigh, D., Gucuk Ipek, E., Kwan, A., Berger, R. D., Calkins, H., Lardo, A. C., et al. (2017) · New England Journal of Medicine · doi:10.1056/nejmoa1604267 · Cited by 301
Taqueti, V. R., Shaw, L. J., Cook, N. R., Murthy, V. L., Shah, N. R., Foster, C. R., Hainer, J., Blankstein, R., Dorbala, S., & Di Carli, M. F. (2017) · Circulation · doi:10.1161/circulationaha.116.023266 · Cited by 299
Regulation of Coronary Blood Flow
Goodwill, A. G., Dick, G. M., Kiel, A. M., & Tune, J. D. (2017) · Comprehensive Physiology · doi:10.1002/cphy.c160016 · Cited by 297
Greenwood, J. P., Ripley, D. P., Berry, C., McCann, G. P., Plein, S., Bucciarelli-Ducci, C., Dall’Armellina, E., Prasad, A., Bijsterveld, P., Foley, J. R., et al. (2016) · JAMA · doi:10.1001/jama.2016.12680 · Cited by 290
Machine learning in cardiovascular magnetic resonance: basic concepts and applications
Leiner, T., Rueckert, D., Suinesiaputra, A., Baeßler, B., Nezafat, R., Išgum, I., & Young, A. A. (2019) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-019-0575-y · Cited by 282
Gutjahr, R., Halaweish, A. F., Yu, Z., Leng, S., Yu, L., Li, Z., Jorgensen, S. M., Ritman, E. L., Kappler, S., & McCollough, C. H. (2016) · Investigative Radiology · doi:10.1097/rli.0000000000000251 · Cited by 282
Muzik, O., Beanlands, R. S., Hutchins, G. D., Mangner, T. J., Nguyen, N. D. S., & Schwaiger, M. (1993) · PubMed · Cited by 270
Patel, M. R., Dai, D., Hernandez, A. F., Douglas, P. S., Messenger, J., Garratt, K. N., Maddox, T. M., Peterson, E. D., & Roe, M. T. (2014) · American Heart Journal · doi:10.1016/j.ahj.2014.03.001 · Cited by 262
Senior, R., Becher, H., Monaghan, M., Agati, L., Zamorano, J., Vanoverschelde, J. L., Nihoyannopoulos, P., Edvardsen, T., Lancellotti, P., Reviewers: This document was reviewed by members of the EACVI Scientific Documents Committee for 2014–16 and 2016–18, et al. (2017) · European Heart Journal - Cardiovascular Imaging · doi:10.1093/ehjci/jex182 · Cited by 255
Self-citationSeiler, C., Fleisch, M., Garachemani, A., & Meier, B. (1998) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(98)00384-2 · Cited by 255
The quantification of absolute myocardial perfusion in humans by contrast echocardiography
Vogel, R., Indermühle, A., Reinhardt, J., Meier, P., Siegrist, P. T., Namdar, M., Kaufmann, P. A., & Seiler, C. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2004.11.044 · Cited by 255
Fearon, W. F., Nishi, T., De Bruyne, B., Boothroyd, D. B., Barbato, E., Tonino, P., Jüni, P., Pijls, N. H. J., & Hlatky, M. A. (2018) · Circulation · doi:10.1161/circulationaha.117.031907 · Cited by 251
Montalescot, G., Sechtem, U., Achenbach, S., Andreotti, F., Arden, C., Budaj, A., BUGIARDINI, R., Crea, F., Cuisset, T., Di Mario, C., et al. (2013) · Open Access CRIS of the University of Bern · doi:10.48350/47454 · Cited by 245
Self-citationDiagnostic Value of 13N-Ammonia Myocardial Perfusion PET: Added Value of Myocardial Flow Reserve
Fiechter, M., Ghadri, J. R., Gebhard, C., Fuchs, T. A., Pazhenkottil, A. P., Nkoulou, R. N., Herzog, B. A., Wyss, C. A., Gaemperli, O., & Kaufmann, P. A. (2012) · Journal of Nuclear Medicine · doi:10.2967/jnumed.111.101840 · Cited by 240
Wei, K., Ragosta, M., Thorpe, J., Coggins, M., Moos, S., & Kaul, S. (2001) · Circulation · doi:10.1161/01.cir.103.21.2560 · Cited by 235
Pries, A. R., Badimon, L., Bugiardini, R., Camici, P. G., Dorobantu, M., Duncker, D. J., Escaned, J., Koller, A., Piek, J. J., & de Wit, C. (2015) · European Heart Journal · doi:10.1093/eurheartj/ehv100 · Cited by 224
Self-citationThe Evolving Future of Instantaneous Wave-Free Ratio and Fractional Flow Reserve
Götberg, M., Cook, C., Sen, S., Nijjer, S. S., Escaned, J., & Davies, J. E. (2017) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2017.07.770 · Cited by 216
Gaemperli, O., Schepis, T., Valenta, I., Koepfli, P., Husmann, L., Scheffel, H., Leschka, S., Eberli, F. R., Luscher, T. F., Alkadhi, H., et al. (2008) · Radiology · doi:10.1148/radiol.2482071307 · Cited by 213
Berman, D. S., Maddahi, J., Tamarappoo, B. K., Czernin, J., Taillefer, R., Udelson, J. E., Gibson, C. M., Devine, M., Lazewatsky, J., Bhat, G., et al. (2013) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.11.022 · Cited by 208
Bache, R. J., & Cobb, F. R. (1977) · Circulation Research · doi:10.1161/01.res.41.5.648 · Cited by 204
Stress Myocardial Perfusion: Imaging with Multidetector CT
Rossi, A., Merkus, D., Klotz, E., Mollet, N., de Feyter, P. J., & Krestin, G. P. (2014) · Radiology · doi:10.1148/radiol.13112739 · Cited by 200
Klibanov, A. L., Rasche, P. T., Hughes, M. S., Wojdyla, J. K., Galen, K. P., Wible, J. H., & Brandenburger, G. H. (2004) · Investigative Radiology · doi:10.1097/01.rli.0000115926.96796.75 · Cited by 199
Analysis of myocardial perfusion MRI
Jerosch‐Herold, M., Seethamraju, R. T., Swingen, C. M., Wilke, N. M., & Stillman, A. E. (2004) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20065 · Cited by 198
Kajander, S. A., Joutsiniemi, E., Saraste, M., Pietilä, M., Ukkonen, H., Saraste, A., Sipilä, H. T., Teräs, M., Mäki, M. T., Airaksinen, J. K. E., et al. (2011) · Circulation Cardiovascular Imaging · doi:10.1161/circimaging.110.960732 · Cited by 189
Hajjiri, M. M., Leavitt, M. B., Zheng, H., Spooner, A. E., Fischman, A. J., & Gewirtz, H. (2009) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2009.04.004 · Cited by 172
Integrating CT Myocardial Perfusion and CT-FFR in the Work-Up of Coronary Artery Disease
Coenen, A., Rossi, A., Lubbers, M. M., Kurata, A., Kono, A. K., Chelu, R. G., Segreto, S., Dijkshoorn, M. L., Wragg, A., van Geuns, R., et al. (2017) · JACC. Cardiovascular imaging · doi:10.1016/j.jcmg.2016.09.028 · Cited by 171
Celeng, C., Leiner, T., Maurovich-Horvat, P., Merkely, B., de Jong, P., Dankbaar, J. W., van Es, H. W., Ghoshhajra, B. B., Hoffmann, U., & Takx, R. A. P. (2019) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2018.07.022 · Cited by 170
Self-citationSchwitter, J., Wacker, C. M., Wilke, N. M., Al‐Saadi, N., Sauer, E., Huettle, K., Schönberg, S. O., Debl, K., Strohm, O., Ahlström, H. K., et al. (2012) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-14-61 · Cited by 165
Engblom, H., Xue, H., Akil, S., Carlsson, M., Hindorf, C., Oddstig, J., Hedeer, F., Hansen, M. S., Aletras, A. H., Kellman, P., et al. (2016) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-017-0388-9 · Cited by 165
Tong, K. L., Kaul, S., Wang, X., Rinkevich, D., Kalvaitis, S., Belcik, T. A., Lepper, W., Foster, W. A., & Wei, K. S. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.03.076 · Cited by 160
Dynamic SPECT Measurement of Absolute Myocardial Blood Flow in a Porcine Model
Wells, R. G., Timmins, R., Klein, R., Lockwood, J., Marvin, B., deKemp, R. A., Wei, L., & Ruddy, T. D. (2014) · Journal of Nuclear Medicine · doi:10.2967/jnumed.114.139782 · Cited by 159
van de Hoef, T. P., Siebes, M., Spaan, J. A. E., & Piek, J. J. (2015) · European Heart Journal · doi:10.1093/eurheartj/ehv235 · Cited by 157
Self-citationHeitner, J. F., Kim, R. J., Kim, H. W., Klem, I., Shah, D. J., Debs, D., Farzaneh‐Far, A., Polsani, V. R., Kim, J. J., Weinsaft, J. W., et al. (2019) · JAMA Cardiology · doi:10.1001/jamacardio.2019.0035 · Cited by 154
Yamamoto, Y., de Silva, R., Rhodes, C. G., Araujo, L. I., Iida, H., Rechavia, E., Nihoyannopoulos, P., Hackett, D., Galassi, A. R., & Taylor, C. (1992) · Circulation · doi:10.1161/01.cir.86.1.167 · Cited by 153
Fractional flow reserve as a surrogate for inducible myocardial ischaemia
van de Hoef, T. P., Meuwissen, M., Escaned, J., Davies, J. E., Siebes, M., Spaan, J. A. E., & Piek, J. J. (2013) · Nature Reviews Cardiology · doi:10.1038/nrcardio.2013.86 · Cited by 144
Self-citationSharir, T., Slomka, P. J., Hayes, S. W., DiCarli, M. F., Ziffer, J. A., Martin, W. H., Dickman, D., Ben‐Haim, S., & Berman, D. S. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.01.028 · Cited by 137
Lubbers, M. M., Coenen, A., Kofflard, M. J. M., Bruning, T. A., Kietselaer, B., Galema, T. W., Kock, M. C. J. M., Niezen, A., Das, M., van Gent, M., et al. (2017) · JACC. Cardiovascular imaging · doi:10.1016/j.jcmg.2017.10.010 · Cited by 127
Kitagawa, K., George, R. T., Arbab‐Zadeh, A., et al. (2010) · Radiology · doi:10.1148/radiol.10091399 · Cited by 126
Prognostic Value of Quantitative Stress Perfusion Cardiac Magnetic Resonance
Sammut, E. C., Villa, A. D. M., Giovine, G. D., Dancy, L., Bosio, F., Gibbs, T., Jeyabraba, S., Schwenke, S., Williams, S. E., Marber, M. S., et al. (2017) · JACC. Cardiovascular imaging · doi:10.1016/j.jcmg.2017.07.022 · Cited by 124
Self-citationBingham, S. E., & Hachamovitch, R. (2011) · Circulation · doi:10.1161/circulationaha.109.907659 · Cited by 119
Farhad, H., Dunet, V., Bachelard, K., Allenbach, G., Kaufmann, P. A., & Prior, J. O. (2013) · European Heart Journal - Cardiovascular Imaging · doi:10.1093/ehjci/jet068 · Cited by 119
Wells, R. G., Marvin, B., Poirier, M., Renaud, J. M., deKemp, R. A., & Ruddy, T. D. (2017) · Journal of Nuclear Medicine · doi:10.2967/jnumed.117.191049 · Cited by 116
Senior, R., Moreo, A. M., Gaibazzi, N., Agati, L., Tiemann, K., Shivalkar, B., von Bardeleben, S., Galiuto, L., Lardoux, H., Trocino, G., et al. (2013) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2013.04.082 · Cited by 112
Self-citationEinstein, A. J., Blankstein, R., Andrews, H., Fish, M. B., Padgett, R. C., Hayes, S. W., Friedman, J. D., Qureshi, M., Rakotoarivelo, H., Slomka, P. J., et al. (2014) · Journal of Nuclear Medicine · doi:10.2967/jnumed.114.138222 · Cited by 111
Coronary pressure-flow relations as basis for the understanding of coronary physiology
van de Hoef, T. P., Nolte, F., Rolandi, M. C., Piek, J. J., van den Wijngaard, J. P. H. M., Spaan, J. A. E., & Siebes, M. (2011) · Journal of Molecular and Cellular Cardiology · doi:10.1016/j.yjmcc.2011.07.025 · Cited by 110
Self-citationGreenwood, J. P., Herzog, B. A., Brown, J. M., Everett, C. C., Nixon, J., Bijsterveld, P., Maredia, N., Motwani, M., Dickinson, C. J., Ball, S. G., et al. (2016) · Annals of Internal Medicine · doi:10.7326/m15-1801 · Cited by 108
Hu, L.-H., Betancur, J., Sharir, T., Einstein, A. J., Bokhari, S., Fish, M. B., Ruddy, T. D., Kaufmann, P. A., Sinusas, A. J., Miller, E. J., et al. (2019) · European Heart Journal - Cardiovascular Imaging · doi:10.1093/ehjci/jez177 · Cited by 106
Diagnostic Accuracy of Myocardial Perfusion Imaging With CZT Technology
Nudi, F., Iskandrian, A. E., Schillaci, O., Peruzzi, M., Frati, G., & Biondi‐Zoccai, G. (2017) · JACC. Cardiovascular imaging · doi:10.1016/j.jcmg.2016.10.023 · Cited by 103
Rief, M., Zimmermann, E., Stenzel, F., Martus, P., Stangl, K., Greupner, J., Knebel, F., Kranz, A., Schlattmann, P., Laule, M., et al. (2013) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2013.03.088 · Cited by 102
Self-citationChen, M. Y., Rochitte, C. E., Arbab‐Zadeh, A., Dewey, M., George, R. T., Miller, J. M., Niinuma, H., Yoshioka, K., Kitagawa, K., Sakuma, H., et al. (2017) · Radiology · doi:10.1148/radiol.2017161565 · Cited by 99
Self-citationKofler, A., Dewey, M., Schaeffter, T., Wald, C., & Kolbitsch, C. (2019) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2019.2930318 · Cited by 98
Self-citationDiastolic time fraction as a determinant of subendocardial perfusion
Fokkema, D. S., VanTeeffelen, J. W. G. E., Dekker, S. E., Vergroesen, I., Reitsma, J. B., & Spaan, J. A. E. (2004) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00790.2004 · Cited by 89
Noninvasive Imaging of the Coronary Vasculature Using Ultrafast Ultrasound
Maresca, D., Correia, M., Villemain, O., Bizé, A., Sambin, L., Tanter, M., Ghaleh, B., & Pernot, M. (2017) · JACC. Cardiovascular imaging · doi:10.1016/j.jcmg.2017.05.021 · Cited by 87
Senior, R., Lepper, W., Pasquet, A., Chung, G., Hoffman, R., Vanoverschelde, J., Cerqueira, M. D., & Kaul, S. (2004) · American Heart Journal · doi:10.1016/j.ahj.2003.12.030 · Cited by 86
Self-citationAssessment of Coronary Artery Stenosis Severity and Location
Chiribiri, A., Hautvast, G. L. T. F., Lockie, T., Schuster, A., Bigalke, B., Olivotti, L., Redwood, S. R., Breeuwer, M. M., Plein, S., & Nagel, E. C. (2013) · JACC. Cardiovascular imaging · doi:10.1016/j.jcmg.2012.09.019 · Cited by 81
Self-citationPrognostic Value of High-Dose Dipyridamole Stress Myocardial Contrast Perfusion Echocardiography
Gaibazzi, N., Reverberi, C., Lorenzoni, V., Molinaro, S., & Porter, T. R. (2012) · Circulation · doi:10.1161/circulationaha.112.110031 · Cited by 80
Cho, H., Lee, J., Kang, S., Kim, W., Choi, S., Ko, J., Min, H., Choi, G., Kang, D., Lee, P. H., et al. (2019) · Journal of the American Heart Association · doi:10.1161/jaha.118.011685 · Cited by 79
Dynamic Computed Tomography Myocardial Perfusion Imaging
Rossi, A., Wragg, A., Klotz, E., et al. (2017) · Circulation Cardiovascular Imaging · doi:10.1161/circimaging.116.005505 · Cited by 74
Yu, M. Z., Nekolla, S. G., Schwaiger, M., et al. (2011) · Seminars in Nuclear Medicine · doi:10.1053/j.semnuclmed.2011.02.004 · Cited by 72
Self-citationNakamura, S., Kitagawa, K., Goto, Y., Omori, T., Kurita, T., Yamada, A., Takafuji, M., Uno, M., Dohi, K., & Sakuma, H. (2018) · JACC. Cardiovascular imaging · doi:10.1016/j.jcmg.2018.05.021 · Cited by 71
Villa, A. D. M., Sammut, E. C., Zarinabad, N., Carr‐White, G., Lee, J., Bettencourt, N., Razavi, R., Nagel, E. C., & Chiribiri, A. (2016) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-016-0223-8 · Cited by 69
Self-citationJuárez‐Orozco, L. E., Knol, R. J. J., Sánchez-Catasús, C. A., Martinez‐Manzanera, O., van der Zant, F. M., & Knuuti, J. M. (2018) · Journal of Nuclear Cardiology · doi:10.1007/s12350-018-1304-x · Cited by 68
Patient Outcome Following 2 Different Stress Imaging Approaches
Porter, T. R., Smith, L. M., Wu, J., Thomas, D., Haas, J., Mathers, D. H., Williams, E., Olson, J. J., Nalty, K., Hess, R., et al. (2013) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2013.04.019 · Cited by 68
Rana, O., Byrne, C. D., Kerr, D., Coppini, D. V., Zouwail, S., Senior, R., Begley, J., Walker, J. J., & Greaves, K. (2011) · Circulation · doi:10.1161/circulationaha.110.992297 · Cited by 64
Self-citationClassification of Polar Maps from Cardiac Perfusion Imaging with Graph-Convolutional Neural Networks
Spier, N., Nekolla, S. G., Rupprecht, C., Mustafa, M., Navab, N., & Baust, M. (2019) · Scientific Reports · doi:10.1038/s41598-019-43951-8 · Cited by 60
Self-citationDiagnosing coronary artery disease with hybrid PET/CT: It takes two to tango
Danad, I., Raijmakers, P. G. H. M., & Knaapen, P. (2013) · Journal of Nuclear Cardiology · doi:10.1007/s12350-013-9753-8 · Cited by 59
Self-citationHarms, H. J., Nesterov, S. V., Han, C., Danad, I., Leonora, R., Raijmakers, P. G. H. M., Lammertsma, A. A., Knuuti, J. M., & Knaapen, P. (2013) · European Heart Journal - Cardiovascular Imaging · doi:10.1093/ehjci/jet177 · Cited by 59
Self-citationLi, Y., Ho, C. P., Toulemonde, M. E. G., Chahal, N., Senior, R., & Tang, M. (2017) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2017.2747081 · Cited by 58
Self-citationIshida, M., Kitagawa, K., Ichihara, T., Natsume, T., Nakayama, R., Nagasawa, N., Kubooka, M., Ito, T., Uno, M., Goto, Y., et al. (2016) · Journal of cardiovascular computed tomography · doi:10.1016/j.jcct.2016.01.008 · Cited by 56
Pazhenkottil, A. P., Benz, D. C., Gräni, C., Madsen, M. A., Mikulicic, F., von Felten, E., Fuchs, T. A., Moch, B. H., Stehli, J., Lüscher, T. F., et al. (2018) · Radiology · doi:10.1148/radiol.2018171303 · Cited by 55
Sørgaard, M. H., Kofoed, K. F., Linde, J. J., George, R. T., Rochitte, C. E., Feuchtner, G. M., Lima, J. A. C., & Abdulla, J. (2016) · Journal of cardiovascular computed tomography · doi:10.1016/j.jcct.2016.09.003 · Cited by 53
Self-citationSørgaard, M. H., Linde, J. J., Kühl, J. T., Kelbæk, H., Hove, J. D., Fornitz, G. G., Jørgensen, T., Heitmann, M., Kragelund, C., Hansen, T. F., et al. (2017) · JACC. Cardiovascular imaging · doi:10.1016/j.jcmg.2017.09.022 · Cited by 52
Self-citationRajpoot, K., Grau, V., Noble, J. A., Szmigielski, C. A., & Becher, H. H. (2011) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2011.04.018 · Cited by 52
Hecht, H. S., Narula, J., & Fearon, W. F. (2016) · Circulation Research · doi:10.1161/circresaha.116.307914 · Cited by 51
Kunze, K., Nekolla, S. G., Rischpler, C., Zhang, S. H., Hayes, C. M. G., Langwieser, N., Ibrahim, T., Laugwitz, K., & Schwaiger, M. (2018) · Magnetic Resonance in Medicine · doi:10.1002/mrm.27213 · Cited by 49
Self-citationSánchez‐Gonzalez, J., Fernández‐Jiménez, R., Nothnagel, N., López-Martín, G. J., Fuster, V., & Ibáñez, B. (2015) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-015-0116-2 · Cited by 48
Taqui, S., Ferencik, M., Davidson, B. P., Belcik, J. T., Moccetti, F., Layoun, M. E., Raber, J., Turker, M. S., Tavori, H., Fazio, S., et al. (2019) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2019.03.001 · Cited by 46
3D Imaging of vascular networks for biophysical modeling of perfusion distribution within the heart
van den Wijngaard, J. P. H. M., Schwarz, J. C. V., van Horssen, P., van Lier, M. G. J. T. B., Dobbe, J. G. G., Spaan, J. A. E., & Siebes, M. (2012) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2012.11.027 · Cited by 45
Self-citationAlessio, A. M., Bindschadler, M., Busey, J. M., Shuman, W. P., Caldwell, J. H., & Branch, K. R. (2019) · Circulation Cardiovascular Imaging · doi:10.1161/circimaging.118.008323 · Cited by 45
Robust universal nonrigid motion correction framework for first‐pass cardiac MR perfusion imaging
Benovoy, M., Jacobs, M., Farida Cheriet, A., Dahdah, N., Arai, A. E., & Hsu, L. (2017) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.25659 · Cited by 43
Historical Aspects and Relevance of the Human Coronary Collateral Circulation
Seiler, C. A., & Meier, P. (2014) · Current Cardiology Reviews · doi:10.2174/1573403x113099990028 · Cited by 30
Kühl, J. T., George, R. T., Mehra, V. C., Linde, J. J., Chen, M. Y., Arai, A. E., Carli, M. F. D., Kitagawa, K., Dewey, M., Lima, J. A. C., et al. (2015) · European Heart Journal - Cardiovascular Imaging · doi:10.1093/ehjci/jev206 · Cited by 26
Self-citationHu, L.-H., Sharir, T., Miller, R. J. H., Einstein, A. J., Fish, M. B., Ruddy, T. D., Dorbala, S., Carli, M. F. D., Kaufmann, P. A., Sinusas, A. J., et al. (2019) · Journal of Nuclear Cardiology · doi:10.1007/s12350-019-01730-y · Cited by 26
Hachamovitch, R. (2015) · Circulation Cardiovascular Imaging · doi:10.1161/circimaging.113.000352 · Cited by 26
Rief, M., Chen, M. Y., Vavere, A. L., Kendziora, B., Miller, J. M., Bandettini, W. P., Cox, C., George, R. T., Lima, J. A. C., Carli, M. F. D., et al. (2017) · Radiology · doi:10.1148/radiol.2017162447 · Cited by 22
Self-citationNakauchi, Y., Iwanaga, Y., Ikuta, S., Kudo, M., Kobuke, K., Murakami, T., & Miyazaki, S. (2012) · Heart · doi:10.1136/heartjnl-2011-300915 · Cited by 21
ACR Appropriateness Criteria Acute Nonspecific Chest Pain—Low Probability of Coronary Artery Disease
Hoffmann, U., Akers, S. R., Brown, R. K. J., Cummings, K. W., Cury, R. C., Greenberg, S. B., Ho, V. B., Hsu, J. Y., Min, J. K., Panchal, K. K., et al. (2015) · Journal of the American College of Radiology · doi:10.1016/j.jacr.2015.09.004 · Cited by 20
Lupo, P., Cappato, R., Leo, G. D., Secchi, F., Papini, G. D. E., Foresti, S., Ali, H., Ambroggi, G. D., Sorgente, A., Epicoco, G., et al. (2018) · European Radiology · doi:10.1007/s00330-017-5098-z · Cited by 17
de Haan, S., Harms, H. J., Lubberink, M., Allaart, C. P., Danad, I., Chen, W. J. Y., Diamant, M., van Rossum, A. C., Iida, H., Lammertsma, A. A., et al. (2012) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-012-2134-8 · Cited by 16
Self-citationvan Horssen, P., Siebes, M., Spaan, J. A. E., Hoefer, I. E., & van den Wijngaard, J. P. H. M. (2014) · The Journal of Physiology · doi:10.1113/jphysiol.2013.258855 · Cited by 15
Self-citationEvaluation of quantitative CMR perfusion imaging by comparison with simultaneous 15O-water-PET
Kero, T., Johansson, E., Engström, M., Eggers, K. M., Johansson, L., Ahlström, H. K., & Lubberink, M. (2019) · Journal of Nuclear Cardiology · doi:10.1007/s12350-019-01810-z · Cited by 14
Self-citationYu, M., Li, Y., Li, W., Lu, Z., Wei, M., & Zhang, J. (2017) · Journal of cardiovascular computed tomography · doi:10.1016/j.jcct.2017.09.017 · Cited by 13
Direct parametric reconstruction in dynamic PET myocardial perfusion imaging: in vivo studies
Petibon, Y., Rakvongthai, Y., Fakhri, G. E., & Ouyang, J. (2017) · Physics in Medicine and Biology · doi:10.1088/1361-6560/aa6394 · Cited by 11
Sommer, K., Bernat, D., Schmidt, R., Breit, H., & Schreiber, W. (2015) · Medical Physics · doi:10.1118/1.4922708 · Cited by 9
Transmural distribution and connectivity of coronary collaterals within the human heart
van Lier, M. G. J. T. B., Oost, E., Spaan, J. A. E., van Horssen, P., van der Wal, A. C., VanBavel, E., Siebes, M., & van den Wijngaard, J. P. H. M. (2016) · Cardiovascular Pathology · doi:10.1016/j.carpath.2016.06.004 · Cited by 7
Self-citation
Cited by
COVID-19 and cardiovascular disease: from basic mechanisms to clinical perspectives
Nishiga, M., Wang, D. W., Han, Y., Lewis, D. B., & Wu, J. C. (2020) · Nature Reviews Cardiology · doi:10.1038/s41569-020-0413-9 · Cited by 1,409
Radiochemistry for positron emission tomography
Rong, J., Haider, A., Jeppesen, T. E., Josephson, L., & Liang, S. H. (2023) · Nature Communications · doi:10.1038/s41467-023-36377-4 · Cited by 294
Tao, R., Zhang, S., Zhang, R., Shen, C., Ma, J., Cui, J., Chen, Y., Wang, B., Li, H., Xie, X., et al. (2025) · Scientific Reports · doi:10.1038/s41598-025-90615-x · Cited by 14
Metadata
- Authors
- on behalf of the Quantitative Cardiac Imaging Study Group, Dewey, M., Siebes, M., Kachelrieß, M., Kofoed, K. F., Maurovich-Horvat, P., Nikolaou, K., Bai, W., Kofler, A., Manka, R., Kozerke, S., Chiribiri, A., Schaeffter, T., Michallek, F., Bengel, F., Nekolla, S., Knaapen, P., Lubberink, M., Senior, R., Tang, M.-X., Piek, J. J., van de Hoef, T., Martens, J., & Schreiber, L.
- Venue
- Nature Reviews Cardiology
- Published
- 2020-02-24
- Volume
- 17
- Issue
- 7
- Pages
- 427-450
- ISSN
- 1759-5002 (ISSN-L)
- 1759-5010
- OpenAlex
- W3008159865
- Cited by
- 184
- References
- 135
- FWCI
- 4.75
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.