Self-powered cardiovascular electronic devices and systems
The DOI matches its Crossref record; 135 of the 136 references it cites were found in a registry or an index.
Abstract
Cardiovascular electronic devices have enormous benefits for health and quality of life but the long-term operation of these implantable and wearable devices remains a huge challenge owing to the limited life of batteries, which increases the risk of device failure and causes uncertainty among patients. A possible approach to overcoming the challenge of limited battery life is to harvest energy from the body and its ambient environment, including biomechanical, solar, thermal and biochemical energy, so that the devices can be self-powered. This strategy could allow the development of advanced features for cardiovascular electronic devices, such as extended life, miniaturization to improve comfort and conformability, and functions that integrate with real-time data transmission, mobile data processing and smart power utilization. In this Review, we present an update on self-powered cardiovascular implantable electronic devices and wearable active sensors. We summarize the existing self-powered technologies and their fundamental features. We then review the current applications of self-powered electronic devices in the cardiovascular field, which have two main goals. The first is to harvest energy from the body as a sustainable power source for cardiovascular electronic devices, such as cardiac pacemakers. The second is to use self-powered devices with low power consumption and high performance as active sensors to monitor physiological signals (for example, for active endocardial monitoring). Finally, we present the current challenges and future perspectives for the field.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Unlike static neural implants mentioned above, in vivo ECG recording equipment on the surface of the heart is subjected to dynamic movement.[375–378]”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [378]
Citations
Cites
Piezoelectric Nanogenerators Based on Zinc Oxide Nanowire Arrays
Wang, Z. L., & Song, J. (2006) · Science · doi:10.1126/science.1124005 · Cited by 7,922
Self-citationMoss, A. J., Zareba, W., Hall, W. J., Klein, H., Wilber, D. J., Cannom, D. S., Daubert, J. P., Higgins, S. L., Brown, M. W., & Andrews, M. L. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa013474 · Cited by 6,902
Flexible triboelectric generator
Fan, F.-R., Tian, Z.-Q., & Lin Wang, Z. (2012) · Nano Energy · doi:10.1016/j.nanoen.2012.01.004 · Cited by 6,705
Amiodarone or an Implantable Cardioverter–Defibrillator for Congestive Heart Failure
Bardy, G. H., Lee, K. L., Mark, D. B., Poole, J. E., Packer, D. L., Boineau, R., Domanski, M., Troutman, C., Anderson, J., Johnson, G., et al. (2005) · New England Journal of Medicine · doi:10.1056/nejmoa043399 · Cited by 6,552
A comparison of rate control and rhythm control in patients with atrial fibrillation
(2002) · New England Journal of Medicine · doi:10.1056/nejmoa021328 · Cited by 4,405
Photoplethysmography and its application in clinical physiological measurement
Allen, J. (2007) · Physiological Measurement · doi:10.1088/0967-3334/28/3/r01 · Cited by 3,967
Cardiac-Resynchronization Therapy for the Prevention of Heart-Failure Events
Moss, A. J., Hall, W. J., Cannom, D. S., Klein, H., Brown, M. W., Daubert, J. P., Estes, N. A. M., Foster, E., Greenberg, H., Higgins, S. L., et al. (2009) · New England Journal of Medicine · doi:10.1056/nejmoa0906431 · Cited by 3,157
Coaxial silicon nanowires as solar cells and nanoelectronic power sources
Tian, B., Zheng, X., Kempa, T. J., Fang, Y., Yu, N., Yu, G., Huang, J., & Lieber, C. M. (2007) · Nature · doi:10.1038/nature06181 · Cited by 2,929
(2013) · European Heart Journal · doi:10.1093/eurheartj/eht150 · Cited by 2,809
Direct-Current Nanogenerator Driven by Ultrasonic Waves
Wang, X., Song, J., Liu, J., & Wang, Z. L. (2007) · Science · doi:10.1126/science.1139366 · Cited by 2,260
Self-citationObservation of the spin Seebeck effect
Uchida, K., Takahashi, S., Harii, K., Ieda, J., Koshibae, W., Ando, K., Maekawa, S., & Saitoh, E. (2008) · Nature · doi:10.1038/nature07321 · Cited by 2,243
Oss, J. M., Areba, W. O. Z., Ackson, W. J., Lein, H. E. K., Ilber, D. A. J. W., Annom, D. A. S. C., Ames, J. M., Aubert, P., Iggins, S. T. L. H., Rown, M. A. W. B., et al. (2002) · Cited by 2,028
Theoretical study of contact-mode triboelectric nanogenerators as an effective power source
Niu, S., Wang, S., Lin, L., Liu, Y., Zhou, Y. S., Hu, Y., & Wang, Z. L. (2013) · Energy & Environmental Science · doi:10.1039/c3ee42571a · Cited by 1,956
Self-citationWang, Z. L. (2014) · Faraday Discuss. · doi:10.1039/c4fd00159a · Cited by 1,749
Self-citationXu, S., Qin, Y., Xu, C., Wei, Y., Yang, R., & Wang, Z. L. (2010) · Nature Nanotechnology · doi:10.1038/nnano.2010.46 · Cited by 1,626
Self-citationSystematic review of the validity and reliability of consumer-wearable activity trackers
Evenson, K. R., Goto, M. M., & Furberg, R. D. (2015) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/s12966-015-0314-1 · Cited by 1,232
Amiodarone to Prevent Recurrence of Atrial Fibrillation
Roy, D., Talajic, M., Dorian, P., Connolly, S., Eisenberg, M. J., Green, M., Kus, T., Lambert, J., Dubuc, M., Gagné, P., et al. (2000) · New England Journal of Medicine · doi:10.1056/nejm200003303421302 · Cited by 1,143
Authors/Task Force Members, Brignole, M., Auricchio, A., Baron-Esquivias, G., Bordachar, P., Boriani, G., Breithardt, O.-A., Cleland, J., Deharo, J.-C., Delgado, V., et al. (2013) · Europace · doi:10.1093/europace/eut206 · Cited by 1,124
Triboelectric-Generator-Driven Pulse Electrodeposition for Micropatterning
Zhu, G., Pan, C., Guo, W., Chen, C.-Y., Zhou, Y., Yu, R., & Wang, Z. L. (2012) · Nano Letters · doi:10.1021/nl302560k · Cited by 1,059
Self-citationWang, S., Xie, Y., Niu, S., Lin, L., & Wang, Z. L. (2014) · Advanced Materials · doi:10.1002/adma.201305303 · Cited by 1,001
Self-citationDagdeviren, C., Su, Y., Joe, P., Yona, R., Liu, Y., Kim, Y.-S., Huang, Y., Damadoran, A. R., Xia, J., Martin, L. W., et al. (2014) · Nature Communications · doi:10.1038/ncomms5496 · Cited by 987
Conformal piezoelectric energy harvesting and storage from motions of the heart, lung, and diaphragm
Dagdeviren, C., Yang, B. D., Su, Y., Tran, P. L., Joe, P., Anderson, E., Xia, J., Doraiswamy, V., Dehdashti, B., Feng, X., et al. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1317233111 · Cited by 975
Toward ubiquitous blood pressure monitoring via pulse transit time: Theory and practice
Mukkamala, R., Hahn, J.-O., Inan, O. T., Mestha, L. K., Kim, C.-S., Toreyin, H., & Kyal, S. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2441951 · Cited by 935
Pyroelectric materials and devices for energy harvesting applications
Bowen, C. R., Taylor, J., LeBoulbar, E., Zabek, D., Chauhan, A., & Vaish, R. (2014) · Energy Environ. Sci. · doi:10.1039/c4ee01759e · Cited by 836
Sliding-Triboelectric Nanogenerators Based on In-Plane Charge-Separation Mechanism
Wang, S., Lin, L., Xie, Y., Jing, Q., Niu, S., & Wang, Z. L. (2013) · Nano Letters · doi:10.1021/nl400738p · Cited by 804
Self-citationNiu, S., Liu, Y., Wang, S., Lin, L., Zhou, Y. S., Hu, Y., & Wang, Z. L. (2014) · Advanced Functional Materials · doi:10.1002/adfm.201303799 · Cited by 737
Self-citationSelf‐Powered Real‐Time Arterial Pulse Monitoring Using Ultrathin Epidermal Piezoelectric Sensors
Park, D. Y., Joe, D. J., Kim, D. H., Park, H., Han, J. H., Jeong, C. K., Park, H., Park, J. G., Joung, B., & Lee, K. J. (2017) · Advanced Materials · doi:10.1002/adma.201702308 · Cited by 691
Syringe-injectable electronics
Liu, J., Fu, T.-M., Cheng, Z., Hong, G., Zhou, T., Jin, L., Duvvuri, M., Jiang, Z., Kruskal, P., Xie, C., et al. (2015) · Nature Nanotechnology · doi:10.1038/nnano.2015.115 · Cited by 687
Zhang, F., Zang, Y., Huang, D., Di, C.-A., & Zhu, D. (2015) · Nature Communications · doi:10.1038/ncomms9356 · Cited by 668
Wearables and the Medical Revolution
Dunn, J., Runge, R., & Snyder, M. (2018) · Personalized Medicine · doi:10.2217/pme-2018-0044 · Cited by 654
Ouyang, H., Liu, Z., Li, N., Shi, B., Zou, Y., Xie, F., Ma, Y., Li, Z., Li, H., Zheng, Q., et al. (2019) · Nature Communications · doi:10.1038/s41467-019-09851-1 · Cited by 647
Self-citationBiodegradable triboelectric nanogenerator as a life-time designed implantable power source
Zheng, Q., Zou, Y., Zhang, Y., Liu, Z., Shi, B., Wang, X., Jin, Y., Ouyang, H., Li, Z., & Wang, Z. L. (2016) · Science Advances · doi:10.1126/sciadv.1501478 · Cited by 617
Self-citationIn Vivo Powering of Pacemaker by Breathing‐Driven Implanted Triboelectric Nanogenerator
Zheng, Q., Shi, B., Fan, F., Wang, X., Yan, L., Yuan, W., Wang, S., Liu, H., Li, Z., & Wang, Z. L. (2014) · Advanced Materials · doi:10.1002/adma.201402064 · Cited by 603
Self-citationTheory of freestanding triboelectric-layer-based nanogenerators
Niu, S., Liu, Y., Chen, X., Wang, S., Zhou, Y. S., Lin, L., Xie, Y., & Wang, Z. L. (2015) · Nano Energy · doi:10.1016/j.nanoen.2015.01.013 · Cited by 595
Self-citationTissue–electronics interfaces: from implantable devices to engineered tissues
Feiner, R., & Dvir, T. (2017) · Nature Reviews Materials · doi:10.1038/natrevmats.2017.76 · Cited by 595
Krumholz, H. M., Merrill, A. R., Schone, E. M., Schreiner, G. C., Chen, J., Bradley, E. H., Wang, Y., Wang, Y., Lin, Z., Straube, B. M., et al. (2009) · Circulation: Cardiovascular Quality and Outcomes · doi:10.1161/circoutcomes.109.883256 · Cited by 580
Mano, N., Mao, F., & Heller, A. (2003) · Journal of the American Chemical Society · doi:10.1021/ja0346328 · Cited by 573
Review of photovoltaic technologies
El Chaar, L., lamont, L. A., & El Zein, N. (2011) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2011.01.004 · Cited by 543
Wearable and Implantable Triboelectric Nanogenerators
Liu, Z., Li, H., Shi, B., Fan, Y., Wang, Z. L., & Li, Z. (2019) · Advanced Functional Materials · doi:10.1002/adfm.201808820 · Cited by 514
Self-citationTriboelectric Nanogenerator Enabled Body Sensor Network for Self-Powered Human Heart-Rate Monitoring
Lin, Z., Chen, J., Li, X., Zhou, Z., Meng, K., Wei, W., Yang, J., & Wang, Z. L. (2017) · ACS Nano · doi:10.1021/acsnano.7b02975 · Cited by 494
Self-citationSelf‐Powered Pulse Sensor for Antidiastole of Cardiovascular Disease
Ouyang, H., Tian, J., Sun, G., Zou, Y., Liu, Z., Li, H., Zhao, L., Shi, B., Fan, Y., Fan, Y., et al. (2017) · Advanced Materials · doi:10.1002/adma.201703456 · Cited by 468
Self-citationIn Vivo Self-Powered Wireless Cardiac Monitoring via Implantable Triboelectric Nanogenerator
Zheng, Q., Zhang, H., Shi, B., Xue, X., Liu, Z., Jin, Y., Ma, Y., Zou, Y., Wang, X., An, Z., et al. (2016) · ACS Nano · doi:10.1021/acsnano.6b02693 · Cited by 449
Self-citationMuscle‐Driven In Vivo Nanogenerator
Li, Z., Zhu, G., Yang, R., Wang, A. C., & Wang, Z. L. (2010) · Advanced Materials · doi:10.1002/adma.200904355 · Cited by 441
Self-citationPower Approaches for Implantable Medical Devices
Amar, A., Kouki, A., & Cao, H. (2015) · Sensors · doi:10.3390/s151128889 · Cited by 432
A Glucose BioFuel Cell Implanted in Rats
Cinquin, P., Gondran, C., Giroud, F., Mazabrard, S., Pellissier, A., Boucher, F., Alcaraz, J.-P., Gorgy, K., Lenouvel, F., Mathé, S., et al. (2010) · PLoS ONE · doi:10.1371/journal.pone.0010476 · Cited by 413
Meng, K., Chen, J., Li, X., Wu, Y., Fan, W., Zhou, Z., He, Q., Wang, X., Fan, X., Zhang, Y., et al. (2019) · Advanced Functional Materials · doi:10.1002/adfm.201806388 · Cited by 409
Self-citationAccuracy of wrist-worn heart rate monitors
Wang, R., Blackburn, G., Desai, M., Phelan, D., Gillinov, L., Houghtaling, P., & Gillinov, M. (2017) · JAMA Cardiology · doi:10.1001/jamacardio.2016.3340 · Cited by 386
Single Glucose Biofuel Cells Implanted in Rats Power Electronic Devices
Zebda, A., Cosnier, S., Alcaraz, J.-P., Holzinger, M., Le Goff, A., Gondran, C., Boucher, F., Giroud, F., Gorgy, K., Lamraoui, H., et al. (2013) · Scientific Reports · doi:10.1038/srep01516 · Cited by 370
Development of Implantable Medical Devices: From an Engineering Perspective
Joung, Y.-H. (2013) · International Neurourology Journal · doi:10.5213/inj.2013.17.3.98 · Cited by 367
Ma, Y., Zheng, Q., Liu, Y., Shi, B., Xue, X., Ji, W., Liu, Z., Jin, Y., Zou, Y., An, Z., et al. (2016) · Nano Letters · doi:10.1021/acs.nanolett.6b01968 · Cited by 367
Self-citationIndications for the use of diagnostic implantable and external ECG loop recorders
Task Force members, Brignole, M., Vardas, P., Hoffman, E., Huikuri, H., Moya, A., Ricci, R., Sulke, N., Wieling, W., EHRA Scientific Documents Committee, et al. (2009) · Europace · doi:10.1093/europace/eup097 · Cited by 362
Energy Harvesting from the Animal/Human Body for Self-Powered Electronics
Dagdeviren, C., Li, Z., & Wang, Z. L. (2017) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071516-044517 · Cited by 348
Self-citationThermal energy harvesting through pyroelectricity
Cuadras, A., Gasulla, M., & Ferrari, V. (2010) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2009.12.018 · Cited by 342
Patient-centered activity monitoring in the self-management of chronic health conditions
Chiauzzi, E., Rodarte, C., & DasMahapatra, P. (2015) · BMC Medicine · doi:10.1186/s12916-015-0319-2 · Cited by 338
A wearable pyroelectric nanogenerator and self-powered breathing sensor
Xue, H., Yang, Q., Wang, D., Luo, W., Wang, W., Lin, M., Liang, D., & Luo, Q. (2017) · Nano Energy · doi:10.1016/j.nanoen.2017.05.056 · Cited by 337
Skin photoplethysmography — a review
Kamal, A. A. R., Harness, J. B., Irving, G., & Mearns, A. J. (1989) · Computer Methods and Programs in Biomedicine · doi:10.1016/0169-2607(89)90159-4 · Cited by 328
Lau, J. K., Lowres, N., Neubeck, L., Brieger, D. B., Sy, R. W., Galloway, C. D., Albert, D. E., & Freedman, S. B. (2013) · International Journal of Cardiology · doi:10.1016/j.ijcard.2013.01.220 · Cited by 326
Wang, Z. L. (2008) · Scientific American · doi:10.1038/scientificamerican0108-82 · Cited by 321
Self-citationTranscatheter Self‐Powered Ultrasensitive Endocardial Pressure Sensor
Liu, Z., Ma, Y., Ouyang, H., Shi, B., Li, N., Jiang, D., Xie, F., Qu, D., Zou, Y., Huang, Y., et al. (2019) · Advanced Functional Materials · doi:10.1002/adfm.201807560 · Cited by 308 · cited 1×
“Bottom middle right image adapted from ref.(114), Wiley.”
BackgroundSelf-citationAggregate National Experience With the Wearable Cardioverter-Defibrillator
Chung, M. K., Szymkiewicz, S. J., Shao, M., Zishiri, E., Niebauer, M. J., Lindsay, B. D., & Tchou, P. J. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.04.016 · Cited by 297
Wang, S., Wang, Z. L., & Yang, Y. (2016) · Advanced Materials · doi:10.1002/adma.201505684 · Cited by 294
Self-citationImplantable Energy‐Harvesting Devices
Shi, B., Li, Z., & Fan, Y. (2018) · Advanced Materials · doi:10.1002/adma.201801511 · Cited by 290
Self-citationBiofuel powered glucose detection in bodily fluids with an n-type conjugated polymer
Ohayon, D., Nikiforidis, G., Savva, A., Giugni, A., Wustoni, S., Palanisamy, T., Chen, X., Maria, I. P., Di Fabrizio, E., Costa, P. M. F. J., et al. (2020) · Nature Materials · doi:10.1038/s41563-019-0556-4 · Cited by 288
The Sleep of the Ring: Comparison of the ŌURA Sleep Tracker Against Polysomnography
de Zambotti, M., Rosas, L., Colrain, I. M., & Baker, F. C. (2019) · Behavioral Sleep Medicine · doi:10.1080/15402002.2017.1300587 · Cited by 287
Air-Flow-Driven Triboelectric Nanogenerators for Self-Powered Real-Time Respiratory Monitoring
Wang, M., Zhang, J., Tang, Y., Li, J., Zhang, B., Liang, E., Mao, Y., & Wang, X. (2018) · ACS Nano · doi:10.1021/acsnano.8b02562 · Cited by 287
Bionic Single-Electrode Electronic Skin Unit Based on Piezoelectric Nanogenerator
Wang, X., Song, W.-Z., You, M.-H., Zhang, J., Yu, M., Fan, Z., Ramakrishna, S., & Long, Y.-Z. (2018) · ACS Nano · doi:10.1021/acsnano.8b04244 · Cited by 281
Hu, Y., Zhang, Y., Xu, C., Zhu, G., & Wang, Z. L. (2010) · Nano Letters · doi:10.1021/nl103203u · Cited by 261
Self-citationDiagnostic utility of a novel leadless arrhythmia monitoring device.
Turakhia, M. P., Hoang, D. D., Zimetbaum, P., Miller, J. D., Froelicher, V. F., Kumar, U. N., Xu, X., Yang, F., & Heidenreich, P. A. (2013) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2013.04.017 · Cited by 258
Recent Advances in Nanogenerator‐Driven Self‐Powered Implantable Biomedical Devices
Parvez Mahmud, M. A., Huda, N., Farjana, S. H., Asadnia, M., & Lang, C. (2018) · Advanced Energy Materials · doi:10.1002/aenm.201701210 · Cited by 246
In Vivo Self‐Powered Wireless Transmission Using Biocompatible Flexible Energy Harvesters
Kim, D. H., Shin, H. J., Lee, H., Jeong, C. K., Park, H., Hwang, G., Lee, H., Joe, D. J., Han, J. H., Lee, S. H., et al. (2017) · Advanced Functional Materials · doi:10.1002/adfm.201700341 · Cited by 245
A Glucose Fuel Cell for Implantable Brain–Machine Interfaces
Rapoport, B. I., Kedzierski, J. T., & Sarpeshkar, R. (2012) · PLoS ONE · doi:10.1371/journal.pone.0038436 · Cited by 242
Risk factors and time delay associated with cardiac device infections: Leiden device registry
Lekkerkerker, J. C., van Nieuwkoop, C., Trines, S. A., van der Bom, J. G., Bernards, A., van de Velde, E. T., Bootsma, M., Zeppenfeld, K., Jukema, J. W., Borleffs, J.-W., et al. (2009) · Heart · doi:10.1136/hrt.2008.151985 · Cited by 234
Permanent Leadless Cardiac Pacemaker Therapy: A Comprehensive Review
Tjong, F. V. Y., & Reddy, V. Y. (2017) · Circulation · doi:10.1161/circulationaha.116.025037 · Cited by 228
Leclercq, C., Gadler, F., Kranig, W., Ellery, S., Gras, D., Lazarus, A., Clémenty, J., Boulogne, E., & Daubert, J.-C. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.11.074 · Cited by 226
Nanogenerator-Based Self-Powered Sensors for Wearable and Implantable Electronics
Li, Z., Zheng, Q., Wang, Z. L., & Li, Z. (2020) · Research · doi:10.34133/2020/8710686 · Cited by 223
Self-citationYu, J. R., Navarro, J., Coburn, J. C., Mahadik, B., Molnar, J., Holmes, J. H., Nam, A. J., & Fisher, J. P. (2019) · Advanced Healthcare Materials · doi:10.1002/adhm.201801471 · Cited by 221
Energy extraction from the biologic battery in the inner ear
Mercier, P. P., Lysaght, A. C., Bandyopadhyay, S., Chandrakasan, A. P., & Stankovic, K. M. (2012) · Nature Biotechnology · doi:10.1038/nbt.2394 · Cited by 217
Cheng, X., Xue, X., Ma, Y., Han, M., Zhang, W., Xu, Z., Zhang, H., & Zhang, H. (2016) · Nano Energy · doi:10.1016/j.nanoen.2016.02.037 · Cited by 208
From nanogenerators to piezotronics—A decade-long study of ZnO nanostructures
Wang, Z. L. (2012) · MRS Bulletin · doi:10.1557/mrs.2012.186 · Cited by 194
Self-citationFlexible piezoelectric devices for gastrointestinal motility sensing
Dagdeviren, C., Javid, F., Joe, P., von Erlach, T., Bensel, T., Wei, Z., Saxton, S., Cleveland, C., Booth, L., McDonnell, S., et al. (2017) · Nature Biomedical Engineering · doi:10.1038/s41551-017-0140-7 · Cited by 194
Adamson, P. B. (2009) · Current Heart Failure Reports · doi:10.1007/s11897-009-0039-z · Cited by 190
Nanogenerator for Biomedical Applications
Feng, H., Zhao, C., Tan, P., Liu, R., Chen, X., & Li, Z. (2018) · Advanced Healthcare Materials · doi:10.1002/adhm.201701298 · Cited by 189
Self-citationZhang, H., Zhang, X.-S., Cheng, X., Liu, Y., Han, M., Xue, X., Wang, S., Yang, F., A S, S., Zhang, H., et al. (2015) · Nano Energy · doi:10.1016/j.nanoen.2014.12.038 · Cited by 188
Ultra-flexible Piezoelectric Devices Integrated with Heart to Harvest the Biomechanical Energy
Lu, B., Chen, Y., Ou, D., Chen, H., Diao, L., Zhang, W., Zheng, J., Ma, W., Sun, L., & Feng, X. (2015) · Scientific Reports · doi:10.1038/srep16065 · Cited by 182
Wang, X., Dai, Y., Liu, R., He, X., Li, S., & Wang, Z. L. (2017) · ACS Nano · doi:10.1021/acsnano.7b03560 · Cited by 180
Self-citationPlanar Heterojunction Perovskite Solar Cells Incorporating Metal–Organic Framework Nanocrystals
Chang, T., Kung, C., Chen, H., Huang, T., Kao, S., Lu, H., Lee, M., Boopathi, K. M., Chu, C., & Ho, K. (2015) · Advanced Materials · doi:10.1002/adma.201502537 · Cited by 176
Keene, D., Arnold, A. D., Jastrzębski, M., Burri, H., Zweibel, S., Crespo, E., Chandrasekaran, B., Bassi, S., Joghetaei, N., Swift, M., et al. (2019) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.14064 · Cited by 176
Energy Harvesting from the Beating Heart by a Mass Imbalance Oscillation Generator
Zurbuchen, A., Pfenniger, A., Stahel, A., Stoeck, C. T., Vandenberghe, S., Koch, V. M., & Vogel, R. (2013) · Annals of Biomedical Engineering · doi:10.1007/s10439-012-0623-3 · Cited by 163
Mesh electronics: a new paradigm for tissue-like brain probes
Hong, G., Yang, X., Zhou, T., & Lieber, C. M. (2018) · Current Opinion in Neurobiology · doi:10.1016/j.conb.2017.11.007 · Cited by 159
GILLIS, A. M., PÜRERFELLNER, H., ISRAEL, C. W., SUNTHORN, H., KACET, S., ANELLI‐MONTI, M., TANG, F., YOUNG, M., BORIANI, G., & On behalf of the Medtronic Enrhythm Clinical Study Investigators (2006) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2006.00422.x · Cited by 158
Wearable technology for cardiology: An update and framework for the future
Pevnick, J. M., Birkeland, K., Zimmer, R., Elad, Y., & Kedan, I. (2018) · Trends in Cardiovascular Medicine · doi:10.1016/j.tcm.2017.08.003 · Cited by 154
Subdermal Flexible Solar Cell Arrays for Powering Medical Electronic Implants
Song, K., Han, J. H., Lim, T., Kim, N., Shin, S., Kim, J., Choo, H., Jeong, S., Kim, Y., Wang, Z. L., et al. (2016) · Advanced Healthcare Materials · doi:10.1002/adhm.201600222 · Cited by 151
Self-citationA Self‐Powered Implantable Drug‐Delivery System Using Biokinetic Energy
Song, P., Kuang, S., Panwar, N., Yang, G. Y., Tng, D. J. H., Tjin, S. C., Ng, W. J., Majid, M. B. A., Zhu, G., Yong, K., et al. (2017) · Advanced Materials · doi:10.1002/adma.201605668 · Cited by 146
Self-citationBiofuel Cell Operating in Vivo in Rat
Castorena‐Gonzalez, J. A., Foote, C., MacVittie, K., Halámek, J., Halámková, L., Martinez‐Lemus, L. A., & Katz, E. (2013) · Electroanalysis · doi:10.1002/elan.201300136 · Cited by 139
The Future of Neuroimplantable Devices: A Materials Science and Regulatory Perspective
Obidin, N., Tasnim, F., & Dagdeviren, C. (2020) · Advanced Materials · doi:10.1002/adma.201901482 · Cited by 126
The recent advances in self‐powered medical information sensors
Zhao, L., Li, H., Meng, J., & Li, Z. (2019) · InfoMat · doi:10.1002/inf2.12064 · Cited by 121
Self-citationA Packaged Self‐Powered System with Universal Connectors Based on Hybridized Nanogenerators
Shi, B., Zheng, Q., Jiang, W., Yan, L., Wang, X., Liu, H., Yao, Y., Li, Z., & Wang, Z. L. (2016) · Advanced Materials · doi:10.1002/adma.201503356 · Cited by 120
Self-citationThe first batteryless, solar-powered cardiac pacemaker
Haeberlin, A., Zurbuchen, A., Walpen, S., Schaerer, J., Niederhauser, T., Huber, C., Tanner, H., Servatius, H., Seiler, J., Haeberlin, H., et al. (2015) · Heart Rhythm · doi:10.1016/j.hrthm.2015.02.032 · Cited by 118
A triboelectric nanogenerator as self-powered temperature sensor based on PVDF and PTFE
Xia, K., Zhu, Z., Zhang, H., & Xu, Z. (2018) · Applied Physics A · doi:10.1007/s00339-018-1942-5 · Cited by 117
Lessons From the First Patient with an Implanted Pacemaker: 1958–2001
LARSSON, B., ELMQVIST, H., RYDÉN, L., & SCHÜLLER, H. (2003) · Pacing and Clinical Electrophysiology · doi:10.1046/j.1460-9592.2003.00162.x · Cited by 111
Does the use of a syncope diagnostic protocol improve the investigation and management of syncope?
Farwell, D. J., & Sulke, A. N. (2004) · Heart · doi:10.1136/heart.90.1.52 · Cited by 109
Recent progress of nanogenerators acting as biomedical sensors in vivo
Sun, J., Yang, A., Zhao, C., Liu, F., & Li, Z. (2019) · 中国科学通报:英文版 · doi:10.1016/j.scib.2019.07.001 · Cited by 108
Self-citationWang, A., Hu, M., Zhou, L., & Qiang, X. (2018) · Nanomaterials · doi:10.3390/nano8121021 · Cited by 106
Advances and Future Directions in Cardiac Pacemakers
Madhavan, M., Mulpuru, S. K., McLeod, C. J., Cha, Y., & Friedman, P. A. (2017) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2016.10.064 · Cited by 104
Orchard, J., Lowres, N., Freedman, S. B., Ladak, L., Lee, W., Zwar, N., Peiris, D., Kamaladasa, Y., Li, J., & Neubeck, L. (2016) · European Journal of Preventive Cardiology · doi:10.1177/2047487316670255 · Cited by 100
A Battery‐Like Self‐Charge Universal Module for Motional Energy Harvest
Tan, P., Zheng, Q., Zou, Y., Shi, B., Jiang, D., Qu, X., Ouyang, H., Zhao, C., Cao, Y., Fan, Y., et al. (2019) · Advanced Energy Materials · doi:10.1002/aenm.201901875 · Cited by 97
Self-citationIn vivo cardiac power generation enabled by an integrated helical piezoelectric pacemaker lead
Dong, L., Closson, A. B., Oglesby, M., Escobedo, D., Han, X., Nie, Y., Huang, S., Feldman, M. D., Chen, Z., & Zhang, J. X. J. (2019) · Nano Energy · doi:10.1016/j.nanoen.2019.104085 · Cited by 97
Amir, O., Rappaport, D., Zafrir, B., & Abraham, W. T. (2013) · Congestive Heart Failure · doi:10.1111/chf.12021 · Cited by 96
Goto, H., Sugiura, T., Harada, Y., & Kazui, T. (1999) · Medical & Biological Engineering & Computing · doi:10.1007/bf02513315 · Cited by 93
Successful pacing using a batteryless sunlight-powered pacemaker
Haeberlin, A., Zurbuchen, A., Schaerer, J., Wagner, J., Walpen, S., Huber, C. H., Haeberlin, H., Fuhrer, J., & Vogel, R. (2014) · EP Europace · doi:10.1093/europace/euu127 · Cited by 92
Bioelectrodes modified with chitosan for long-term energy supply from the body
El Ichi, S., Zebda, A., Alcaraz, J.-P., Laaroussi, A., Boucher, F., Boutonnat, J., Reverdy-Bruas, N., Chaussy, D., Belgacem, M. N., Cinquin, P., et al. (2015) · Energy & Environmental Science · doi:10.1039/c4ee03430a · Cited by 90
Detection of Phantom Arrhythmias and Evanescent Electrocardiographic Abnormalities
Corday, E. (1965) · JAMA · doi:10.1001/jama.1965.03090060007001 · Cited by 80
The Accuracy of Heart Rate Monitoring by Some Wrist-Worn Activity Trackers
Cadmus-Bertram, L., Gangnon, R., Wirkus, E. J., Thraen-Borowski, K. M., & Gorzelitz-Liebhauser, J. (2017) · Annals of Internal Medicine · doi:10.7326/l16-0353 · Cited by 80
Ambulatory blood pressure monitoring
Sheps, S. G., Pickering, T. G., White, W. B., Weber, M. A., Clement, D. L., Krakoff, L. R., Messerli, F. H., & Perloff, D. L. (1994) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(94)90400-6 · Cited by 76
Energy Harvesting from the Cardiovascular System, or How to Get a Little Help from Yourself
Pfenniger, A., Jonsson, M., Zurbuchen, A., Koch, V. M., & Vogel, R. (2013) · Annals of Biomedical Engineering · doi:10.1007/s10439-013-0887-2 · Cited by 69
Are complications of implantable defibrillators under-estimated and benefits over-estimated?
Brignole, M. (2009) · EP Europace · doi:10.1093/europace/eup174 · Cited by 69
Solomon, M. D., Yang, J., Sung, S. H., Livingston, M. L., Sarlas, G., Lenane, J. C., & Go, A. S. (2016) · BMC Cardiovascular Disorders · doi:10.1186/s12872-016-0210-x · Cited by 65
Clinical Validation of Heart Rate Apps: Mixed-Methods Evaluation Study
Vandenberk, T., Stans, J., Mortelmans, C., Van Haelst, R., Van Schelvergem, G., Pelckmans, C., Smeets, C. J., Lanssens, D., De Cannière, H., Storms, V., et al. (2017) · JMIR mHealth and uHealth · doi:10.2196/mhealth.7254 · Cited by 58
Boriani, G., Rusconi, L., Biffi, M., Pavia, L., Sassara, M., Malfitano, D., Bongiorni, M. G., Padeletti, L., Filice, I., Sanfelici, D., et al. (2006) · EP Europace · doi:10.1093/europace/euj027 · Cited by 57
Actual Pacemaker Longevity: The Benefit of Stimulation by Automatic Capture Verification
Biffi, M., Bertini, M., Saporito, D., Ziacchi, M., Martignani, C., Diemberger, I., & Boriani, G. (2010) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2010.02724.x · Cited by 51
Wireless Communication by an Autonomous Self-Powered Cyborg Insect
Schwefel, J., Ritzmann, R. E., Lee, I. N., Pollack, A. J., Weeman, W., Garverick, S., Willis, M. A., Rasmussen, M., & Scherson, D. A. (2014) · Journal of The Electrochemical Society · doi:10.1149/2.0171413jes · Cited by 48
Performance Enhancement of a Graphene-Zinc Phosphide Solar Cell Using the Electric Field-Effect
Vázquez-Mena, O., Bosco, J. P., Ergen, O., Rasool, H. I., Fathalizadeh, A., Tosun, M., Crommie, M. F., Javey, A., Atwater, H. A., & Zettl, A. K. (2014) · Nano Letters · doi:10.1021/nl500925n · Cited by 48
Energy Harvesting by Subcutaneous Solar Cells: A Long-Term Study on Achievable Energy Output
Bereuter, L., Williner, S., Pianezzi, F., Bissig, B., Buecheler, S., Burger, J., Vogel, R., Zurbuchen, A., & Haeberlin, A. (2017) · Annals of Biomedical Engineering · doi:10.1007/s10439-016-1774-4 · Cited by 47
Towards Batteryless Cardiac Implantable Electronic Devices—The Swiss Way
Zurbuchen, A., Haeberlin, A., Pfenniger, A., Bereuter, L., Schaerer, J., Jutzi, F., Huber, C. H., Fuhrer, J., & Vogel, R. (2016) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2016.2580658 · Cited by 45
Munawar, D. A., Mahajan, R., Linz, D., Wong, G. R., Khokhar, K. B., Thiyagarajah, A., Kadhim, K., Emami, M., Mishima, R. S., Elliott, A. D., et al. (2018) · Heart Rhythm · doi:10.1016/j.hrthm.2018.07.029 · Cited by 42
Technologies for Prolonging Cardiac Implantable Electronic Device Longevity
Lau, E. W. (2016) · Pacing and Clinical Electrophysiology · doi:10.1111/pace.12989 · Cited by 40
Fabrication of an Ultra-Flexible ZnO Nanogenerator for Harvesting Energy from Respiration
Lin, H., Wuu, D., Shen, K., & Horng, R. (2013) · ECS Journal of Solid State Science and Technology · doi:10.1149/2.001311jss · Cited by 30
Percent ventricular pacing with managed ventricular pacing mode in standard pacemaker population
Milašinović, G., Tscheliessnigg, K., Boehmer, A., Vančura, V., Schuchert, A., Brandt, J., Wiggenhorn, C., Hofman, M., & Sperzel, J. (2008) · EP Europace · doi:10.1093/europace/eum288 · Cited by 29
Editorial -- Cardiovascular diseases: causes, surveillance and prevention
Beaglehole, R., Saracci, R., & Panico, S. (2001) · International Journal of Epidemiology · doi:10.1093/ije/30.suppl_1.s1 · Cited by 28
Malfatto, G., Villani, A., Rosa, F. D., Rella, V., Oldani, M., Giglio, A., Facchini, M., & Parati, G. (2014) · Journal of Cardiovascular Medicine · doi:10.2459/jcm.0000000000000177 · Cited by 13
In Vivo Self-PoweredWireless Cardiac Monitoring via Implantable TriboelectricNanogenerator
Qiang, Z., Zhang, H., Shi, B., Xiang, X. L., Liu, Z., Jin, Y., Ma, Y., Zou, Y., Wang, X., Zhao, A., et al. (2016) · OPAL (Open@LaTrobe) (La Trobe University) · doi:10.1021/acsnano.6b02693.s001 · Cited by 10
Self-citationEllenbogen, K. A., & Vijayaraman, P. (2015) · JACC. Clinical electrophysiology · doi:10.1016/j.jacep.2015.09.007 · Cited by 9
Dotsenko, O., Barsheshet, A., & Huang, D. T.-C. (2012) · Expert Review of Cardiovascular Therapy · doi:10.1586/erc.12.120 · Cited by 8
Electronic cardiac medicine: present and future opportunities
Auricchio, A., & Moccetti, T. (2010) · Swiss Medical Weekly · doi:10.4414/smw.2010.13052 · Cited by 8
Implantable Cardioverter–Defibrillators: A New Preventive Medical Option
Glatter, K. A., Young, J. N., & McElvany, M. D. (2006) · Preventive Cardiology · doi:10.1111/j.1520-037x.2006.3647.x · Cited by 6
Research works printed but not linked: 4
- Teplitzky, B. A. & McRoberts, M. in 2018 IEEE 15th International Conference on Wearable and Implantable Body Sensor Networks (BSN) 58–61 (IEEE, 2018).
- Selvaraj, N. in 2014 IEEE Healthcare Innovations Conference (HIC) 83–86 (IEEE, 2014).
- Burleson, W., Clark, S. S., Ransford, B. & Fu, K. in DAC Design Automation Conference 2012 12–17 (IEEE, 2012).
- Hovel, H. J. in Semiconductors and Semimetals Vol. 11 (eds Willardson, R. K. & Beer, A. C.) 181–207 (Academic Press, 1975).
Cited by
Technology Roadmap for Flexible Sensors
Luo, Y., Abidian, M. R., Ahn, J.-H., Akinwande, D., Andrews, A. M., Antonietti, M., Bao, Z., Berggren, M., Berkey, C. A., Bettinger, C. J., et al. (2023) · ACS Nano · doi:10.1021/acsnano.2c12606 · Cited by 1,383
Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics
Heng, W., Solomon, S., & Gao, W. (2022) · Advanced Materials · doi:10.1002/adma.202107902 · Cited by 609
Flexible self-charging power sources
Liu, R., Wang, Z. L., Fukuda, K., & Someya, T. (2022) · Nature Reviews Materials · doi:10.1038/s41578-022-00441-0 · Cited by 526
Self-citationSelf‐Powered Respiration Monitoring Enabled By a Triboelectric Nanogenerator
Su, Y., Chen, G., Chen, C., Gong, Q., Xie, G., Yao, M., Tai, H., Jiang, Y., & Chen, J. (2021) · Advanced Materials · doi:10.1002/adma.202101262 · Cited by 481
Flexible Wearable Sensors for Cardiovascular Health Monitoring
Chen, S., Qi, J., Fan, S., Qiao, Z., Yeo, J. C., & Lim, C. T. (2021) · Advanced Healthcare Materials · doi:10.1002/adhm.202100116 · Cited by 453
Metadata
- Authors
- Zheng, Q., Tang, Q., Wang, Z. L., & Li, Z.
- Affiliations
- Chinese Academy of Sciences (CN)
- Renmin Hospital of Wuhan University (CN)
- Georgia Institute of Technology (US)
- Corresponding author
- Wang, Zhong Lin
- Li, Zhou
- Venue
- Nature Reviews Cardiology
- Published
- 2020-09-07
- Volume
- 18
- Issue
- 1
- Pages
- 7-21
- ISSN
- 1759-5002 (ISSN-L)
- 1759-5010
- OpenAlex
- W3084056592
- Cited by
- 348
- References
- 136
- Citations by year
- 2026: 28 · 2025: 56 · 2024: 66 · 2023: 72 · 2022: 55 · 2021: 65 · 2020: 6
- FWCI
- 3.82
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- www.springer.com/tdm (vor)
- Locations
- Nature Reviews Cardiology (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Engineering › Mechanical Engineering › Innovative Energy Harvesting Technologies
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
- Physical Sciences › Engineering › Biomedical Engineering › Wireless Body Area Networks
- Keywords
- self-powered devices, energy harvesting, implantable electronics, wearable sensors, cardiac pacemaker, low-power sensors, physiological monitoring, battery life
- MeSH terms
- Wearable Electronic Devices, Cardiovascular Diseases, Cardiovascular System, Humans, Electric Power Supplies
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.