Optical clock comparison for Lorentz symmetry testing
Open accessThe DOI matches its Crossref record; 39 of the 39 references it cites were found in a registry or an index.
Abstract
Questioning basic assumptions about the structure of space and time has greatly enhanced our understanding of nature. State-of-the-art atomic clocks1–3 make it possible to precisely test fundamental symmetry properties of spacetime and search for physics beyond the standard model at low energies of just a few electronvolts4. Modern tests of Einstein’s theory of relativity try to measure so-far-undetected violations of Lorentz symmetry5; accurately comparing the frequencies of optical clocks is a promising route to further improving such tests6. Here we experimentally demonstrate agreement between two single-ion optical clocks at the 10−18 level, directly validating their uncertainty budgets, over a six-month comparison period. The ytterbium ions of the two clocks are confined in separate ion traps with quantization axes aligned along non-parallel directions. Hypothetical Lorentz symmetry violations5–7 would lead to periodic modulations of the frequency offset as the Earth rotates and orbits the Sun. From the absence of such modulations at the 10−19 level we deduce stringent limits of the order of 10−21 on Lorentz symmetry violation parameters for electrons, improving previous limits8–10 by two orders of magnitude. Such levels of precision will be essential for low-energy tests of future quantum gravity theories describing dynamics at the Planck scale4, which are expected to predict the magnitude of residual symmetry violations. Agreement between two single-ion clocks is demonstrated experimentally at the 10−18 level over a six-month period, confirming a key postulate of Einstein’s theory of relativity with hundredfold-improved precision.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Lorentz-violating extension of the standard model
Colladay, D., & Kostelecký, V. A. (1998) · Physical Review D · doi:10.1103/physrevd.58.116002 · Cited by 2,403
Ludlow, A. D., Boyd, M. M., Ye, J., Peik, E., & Schmidt, P. O. (2015) · Reviews of Modern Physics · doi:10.1103/revmodphys.87.637 · Cited by 2,385
Self-citationSearch for new physics with atoms and molecules
Safronova, M. S., Budker, D., DeMille, D., Kimball, D. F. J., Derevianko, A., & Clark, C. W. (2018) · Reviews of Modern Physics · doi:10.1103/revmodphys.90.025008 · Cited by 1,560
Self-citationFrequency Ratio of Al+and Hg+Single-Ion Optical Clocks; Metrology at the 17th Decimal Place
Rosenband, T., Hume, D. B., Schmidt, P. O., Chou, C. W., Brusch, A., Lorini, L., Oskay, W. H., Drullinger, R. E., Fortier, T. M., Stalnaker, J. E., et al. (2008) · Science · doi:10.1126/science.1154622 · Cited by 1,450
Data tables for Lorentz andCPTviolation
Kostelecký, V. A., & Russell, N. (2011) · Reviews of Modern Physics · doi:10.1103/revmodphys.83.11 · Cited by 1,390
Modern Tests of Lorentz Invariance
Mattingly, D. (2005) · Living Reviews in Relativity · doi:10.12942/lrr-2005-5 · Cited by 1,061
Systematic evaluation of an atomic clock at 2 × 10−18 total uncertainty
Nicholson, T. L., Campbell, S. L., Hutson, R. B., Marti, G. E., Bloom, B. J., McNally, R. L., Zhang, W., Barrett, M. D., Safronova, M. S., Strouse, G. F., et al. (2015) · Nature Communications · doi:10.1038/ncomms7896 · Cited by 780
Self-citationSignals for Lorentz violation in electrodynamics
Kostelecký, V. A., & Mewes, M. (2002) · Physical Review D · doi:10.1103/physrevd.66.056005 · Cited by 767
Atomic clock performance enabling geodesy below the centimetre level
McGrew, W. F., Zhang, X., Fasano, R. J., Schäffer, S. A., Beloy, K., Nicolodi, D., Brown, R. C., Hinkley, N., Milani, G., Schioppo, M., et al. (2018) · Nature · doi:10.1038/s41586-018-0738-2 · Cited by 727
Single-Ion Atomic Clock with 3 × 10 − 18 Systematic Uncertainty
Huntemann, N., Sanner, C., Lipphardt, B., Tamm, C., & Peik, E. (2016) · Physical Review Letters · doi:10.1103/physrevlett.116.063001 · Cited by 677
Self-citation1.5 μm Lasers with Sub-10 mHz Linewidth
Matei, D. G., Legero, T., Häfner, S., Grebing, C., Weyrich, R., Zhang, W., Sonderhouse, L., Robinson, J. M., Ye, J., Riehle, F., et al. (2017) · Physical Review Letters · doi:10.1103/physrevlett.118.263202 · Cited by 584
Godun, R. M., Nisbet-Jones, P. B. R., Jones, J. M., King, S. A., Johnson, L. A. M., Margolis, H. S., Szymaniec, K., Lea, S. N., Bongs, K., & Gill, P. (2014) · Physical Review Letters · doi:10.1103/physrevlett.113.210801 · Cited by 468
A Fermi-degenerate three-dimensional optical lattice clock
Campbell, S. L., Hutson, R. B., Marti, G. E., Goban, A., Darkwah Oppong, N., McNally, R. L., Sonderhouse, L., Robinson, J. M., Zhang, W., Bloom, B. J., et al. (2017) · Science · doi:10.1126/science.aam5538 · Cited by 384
Constraints on Lorentz violation from clock-comparison experiments
Kostelecký, V. A., & Lane, C. D. (1999) · Physical Review D · doi:10.1103/physrevd.60.116010 · Cited by 378
‘Designer atoms’ for quantum metrology
Roos, C. F., Chwalla, M., Kim, K., Riebe, M., & Blatt, R. (2006) · Nature · doi:10.1038/nature05101 · Cited by 343
Matter-gravity couplings and Lorentz violation
Kostelecký, V. A., & Tasson, J. D. (2011) · Physical Review D · doi:10.1103/physrevd.83.016013 · Cited by 341
Experimental Establishment of the Relativity of Time
Kennedy, R. J., & Thorndike, E. M. (1932) · Physical Review · doi:10.1103/physrev.42.400 · Cited by 298
Upper Limit for the Anisotropy of Inertial Mass from Nuclear Resonance Experiments
Hughes, V. W., Robinson, H. G., & Beltran-Lopez, V. (1960) · Physical Review Letters · doi:10.1103/physrevlett.4.342 · Cited by 280
A search for anisotropy of inertial mass using a free precession technique
Drever, R. W. P. (1961) · Philosophical Magazine · doi:10.1080/14786436108244418 · Cited by 247
Test of Special Relativity Using a Fiber Network of Optical Clocks
Delva, P., Lodewyck, J., Bilicki, S., Bookjans, E., Vallet, G., Le Targat, R., Pottie, P.-E., Guerlin, C., Meynadier, F., Le Poncin-Lafitte, C., et al. (2017) · Physical Review Letters · doi:10.1103/physrevlett.118.221102 · Cited by 227
Probing Lorentz andCPTviolation with space-based experiments
Bluhm, R., Kostelecký, V. A., Lane, C. D., & Russell, N. (2003) · Physical Review D · doi:10.1103/physrevd.68.125008 · Cited by 185
Madej, A. A., Dubé, P., Zhou, Z., Bernard, J. E., & Gertsvolf, M. (2012) · Physical Review Letters · doi:10.1103/physrevlett.109.203002 · Cited by 155
Hyper-Ramsey spectroscopy of optical clock transitions
Yudin, V. I., Taichenachev, A. V., Oates, C. W., Barber, Z. W., Lemke, N. D., Ludlow, A. D., Sterr, U., Lisdat, C., & Riehle, F. (2010) · Physical Review A · doi:10.1103/physreva.82.011804 · Cited by 139
Michelson–Morley analogue for electrons using trapped ions to test Lorentz symmetry
Pruttivarasin, T., Ramm, M. T., Porsev, S. G., Tupitsyn, I. I., Safronova, M. S., Hohensee, M., & Häffner, H. (2015) · Nature · doi:10.1038/nature14091 · Cited by 138
Self-citationHohensee, M., Leefer, N., Budker, D., Harabati, C., Dzuba, V. A., & Flambaum, V. V. (2013) · Physical Review Letters · doi:10.1103/physrevlett.111.050401 · Cited by 138
Evaluation of systematic shifts of the88Sr+single-ion optical frequency standard at the10−17level
Dubé, P., Madej, A. A., Zhou, Z., & Bernard, J. E. (2013) · Physical Review A · doi:10.1103/physreva.87.023806 · Cited by 127
Precise determination of micromotion for trapped-ion optical clocks
Keller, J., Partner, H. L., Burgermeister, T., & Mehlstäubler, T. E. (2015) · Journal of Applied Physics · doi:10.1063/1.4930037 · Cited by 113
Optical cavity tests of Lorentz invariance for the electron
Müller, H., Herrmann, S., Saenz, A., Peters, A., & Lämmerzahl, C. (2003) · Physical Review D · doi:10.1103/physrevd.68.116006 · Cited by 101
Strongly enhanced effects of Lorentz symmetry violation in entangled Yb+ ions
Dzuba, V. A., Flambaum, V. V., Safronova, M. S., Porsev, S. G., Pruttivarasin, T., Hohensee, M., & Häffner, H. (2016) · Nature Physics · doi:10.1038/nphys3610 · Cited by 92
Self-citationTesting Lorentz invariance by the use of vacuum and matter filled cavity resonators
Müller, H. (2005) · Physical review. D. Particles, fields, gravitation, and cosmology/Physical review. D. Particles and fields · doi:10.1103/physrevd.71.045004 · Cited by 85
Synchrotron and inverse Compton constraints on Lorentz violations for electrons
Altschul, B. (2006) · Physical review. D. Particles, fields, gravitation, and cosmology/Physical review. D. Particles and fields · doi:10.1103/physrevd.74.083003 · Cited by 73
Cs-based optical frequency measurement using cross-linked optical and microwave oscillators
Tamm, C., Huntemann, N., Lipphardt, B., Gerginov, V., Nemitz, N., Kazda, M., Weyers, S., & Peik, E. (2014) · Physical Review A · doi:10.1103/physreva.89.023820 · Cited by 72
Self-citationNew Methods for Testing Lorentz Invariance with Atomic Systems
Shaniv, R., Ozeri, R., Safronova, M. S., Porsev, S. G., Dzuba, V. A., Flambaum, V. V., & Häffner, H. (2018) · Physical Review Letters · doi:10.1103/physrevlett.120.103202 · Cited by 69
Self-citationZanon-Willette, T., Lefèvre, R., Metzdorff, R., Sillitoe, N., Almonacil, S., Minissale, M., de Clercq, E., Тайченачев, А. В., Yudin, V. I., & Arimondo, E. (2018) · Reports on Progress in Physics · doi:10.1088/1361-6633/aac9e9 · Cited by 67
Lorentz and C P T tests with clock-comparison experiments
Kostelecký, V. A., & Vargas, A. J. (2018) · Physical review. D/Physical review. D. · doi:10.1103/physrevd.98.036003 · Cited by 62
Analysis of thermal radiation in ion traps for optical frequency standards
Doležal, M., Balling, P., Nisbet-Jones, P. B. R., King, S. A., Jones, J. M., Klein, H. A., Gill, P., Lindvall, T., Wallin, A. E., Merimaa, M., et al. (2015) · Metrologia · doi:10.1088/0026-1394/52/6/842 · Cited by 56
Self-citationCompensation of field-induced frequency shifts in Ramsey spectroscopy of optical clock transitions
Taichenachev, A. V., Yudin, V. I., Oates, C. W., Barber, Z. W., Lemke, N., Ludlow, A. D., Sterr, U., Lisdat, C., & Riehle, F. (2010) · Journal of Experimental and Theoretical Physics Letters · doi:10.1134/s0021364009230052 · Cited by 32
1.5 μm Lasers with sub 10 mHz Linewidth
Legero, T., Matei, D. G., Häfner, S., Grebing, C., Weyrich, R., Riehle, F., Sterr, U., Zhang, W., Robinson, J., Sonderhouse, L., et al. (2017) · Conference on Lasers and Electro-Optics · doi:10.1364/cleo_si.2017.sw1j.1 · Cited by 26
Observation of superconductivity and surface noise using a single trapped ion as a field probe
Lakhmanskiy, K., Holz, P. C., Schärtl, D., Ames, B., Assouly, R., Monz, T., Colombe, Y., & Blatt, R. (2019) · Physical Review A · doi:10.1103/physreva.99.023405 · Cited by 18
Cited by
Test of general relativity by a pair of transportable optical lattice clocks
Takamoto, M., Ushijima, I., Ohmae, N., Yahagi, T., Kokado, K., Shinkai, H., & Katori, H. (2020) · Nature Photonics · doi:10.1038/s41566-020-0619-8 · Cited by 507
Demonstration of 4.8 × 10−17 stability at 1 s for two independent optical clocks
Oelker, E., Hutson, R. B., Kennedy, C. J., Sonderhouse, L., Bothwell, T., Goban, A., Kedar, D., Sanner, C., Robinson, J. M., Marti, G. E., et al. (2019) · Nature Photonics · doi:10.1038/s41566-019-0493-4 · Cited by 475
Self-citationResolving the gravitational redshift across a millimetre-scale atomic sample
Bothwell, T., Kennedy, C. J., Aeppli, A., Kedar, D., Robinson, J. M., Oelker, E., Staron, A., & Ye, J. (2022) · Nature · doi:10.1038/s41586-021-04349-7 · Cited by 449
Frequency ratio measurements at 18-digit accuracy using an optical clock network
Boulder Atomic Clock Optical Network (BACON) Collaboration*, Beloy, K., Bodine, M. I., Bothwell, T., Brewer, S. M., Bromley, S. L., Chen, J.-S., Deschênes, J.-D., Diddams, S. A., Fasano, R. J., et al. (2021) · Nature · doi:10.1038/s41586-021-03253-4 · Cited by 390
JILA SrI optical lattice clock with uncertainty of 2.0 × 10 − 18
Bothwell, T., Kedar, D., Oelker, E., Robinson, J. M., Bromley, S. L., Tew, W. L., Ye, J., & Kennedy, C. J. (2019) · Metrologia · doi:10.1088/1681-7575/ab4089 · Cited by 324
Metadata
- Authors
- Sanner, C., Huntemann, N., Lange, R., Tamm, C., Peik, E., Safronova, M. S., & Porsev, S. G.
- Venue
- Nature
- Published
- 2019-03
- Volume
- 567
- Issue
- 7747
- Pages
- 204-208
- ISSN
- 0028-0836 (ISSN-L)
- 1476-4687
- OpenAlex
- W2894213261
- Cited by
- 275
- References
- 39
- FWCI
- 12.56
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.