A tissue-like neurotransmitter sensor for the brain and gut
Open accessThe DOI matches its Crossref record; 58 of the 58 references it cites were found in a registry or an index.
Abstract
Neurotransmitters play essential roles in regulating neural circuit dynamics both in the central nervous system as well as at the peripheral, including the gastrointestinal tract1–3. Their real-time monitoring will offer critical information for understanding neural function and diagnosing disease1–3. However, bioelectronic tools to monitor the dynamics of neurotransmitters in vivo, especially in the enteric nervous systems, are underdeveloped. This is mainly owing to the limited availability of biosensing tools that are capable of examining soft, complex and actively moving organs. Here we introduce a tissue-mimicking, stretchable, neurochemical biological interface termed NeuroString, which is prepared by laser patterning of a metal-complexed polyimide into an interconnected graphene/nanoparticle network embedded in an elastomer. NeuroString sensors allow chronic in vivo real-time, multichannel and multiplexed monoamine sensing in the brain of behaving mouse, as well as measuring serotonin dynamics in the gut without undesired stimulations and perturbing peristaltic movements. The described elastic and conformable biosensing interface has broad potential for studying the impact of neurotransmitters on gut microbes, brain–gut communication and may ultimately be extended to biomolecular sensing in other soft organs across the body. NeuroString, a tissue-like biological interface created by laser patterning of polyimide into a graphene/nanoparticle network embedded in an elastomer, is introduced, allowing in vivo real-time detection of neurotransmitters in the brain and gut.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Dopamine, learning and motivation.
Wise, R. A. (2004) · Nature Reviews Neuroscience · doi:10.1038/nrn1406 · Cited by 3,379
Bardo, M. T., & Hammer, R. P. (1991) · Neuroscience · doi:10.1016/0306-4522(91)90226-e · Cited by 3,219
Laser-induced porous graphene films from commercial polymers
Lin, J., Peng, Z., Liu, Y., Ruiz-Zepeda, F., Ye, R., Samuel, E. L. G., Yacaman, M. J., Yakobson, B. I., & Tour, J. M. (2014) · Nature Communications · doi:10.1038/ncomms6714 · Cited by 2,946
Self-citationOkayasu, I., Hatakeyama, S., Yamada, M., Ohkusa, T., Inagaki, Y., & Nakaya, R. (1990) · Gastroenterology · doi:10.1016/0016-5085(90)90290-h · Cited by 2,401
The brain reward circuitry in mood disorders
Russo, S. J., & Nestler, E. J. (2013) · Nature Reviews Neuroscience · doi:10.1038/nrn3381 · Cited by 1,870 · cited 2×
“(7) For easier placing the mouse gut, a pullulan solution (0.”
BackgroundMethodThe enteric nervous system and neurogastroenterology
Furness, J. B. (2012) · Nature Reviews Gastroenterology & Hepatology · doi:10.1038/nrgastro.2012.32 · Cited by 1,619 · cited 1×
“(10) Dissolving of the pullulan in tissue finally releases the NeuroString as a soft implant.”
BackgroundChemically induced mouse models of acute and chronic intestinal inflammation
Wirtz, S., Popp, V., Kindermann, M., Gerlach, K., Weigmann, B., Fichtner-Feigl, S., & Neurath, M. F. (2017) · Nature Protocols · doi:10.1038/nprot.2017.044 · Cited by 1,575
Gershon, M. D., & Tack, J. (2007) · Gastroenterology · doi:10.1053/j.gastro.2006.11.002 · Cited by 1,563
Addiction and the brain: The neurobiology of compulsion and its persistence
Hyman, S. E., & Malenka, R. C. (2001) · Nature Reviews Neuroscience · doi:10.1038/35094560 · Cited by 1,302
Serotonin signalling in the gut: functions, dysfunctions and therapeutic targets
Mawe, G. M., & Hoffman, J. M. (2013) · Nature Reviews Gastroenterology & Hepatology · doi:10.1038/nrgastro.2013.105 · Cited by 1,165
Cited by
Technology Roadmap for Flexible Sensors
Luo, Y., Abidian, M. R., Ahn, J.-H., Akinwande, D., Andrews, A. M., Antonietti, M., Bao, Z., Berggren, M., Berkey, C. A., Bettinger, C. J., et al. (2023) · ACS Nano · doi:10.1021/acsnano.2c12606 · Cited by 1,383
Self-citationDevice integration of electrochemical biosensors
Wu, J., Liu, H., Chen, W., Ma, B., & Ju, H. (2023) · Nature Reviews Bioengineering · doi:10.1038/s44222-023-00032-w · Cited by 895
Stretchable graphene–hydrogel interfaces for wearable and implantable bioelectronics
Lu, Y., Yang, G., Wang, S., Zhang, Y., Jian, Y., He, L., Yu, T., Luo, H., Kong, D., Xianyu, Y., et al. (2023) · Nature Electronics · doi:10.1038/s41928-023-01091-y · Cited by 442
Defect engineering of two-dimensional materials for advanced energy conversion and storage
Liu, F., & Fan, Z. (2023) · Chemical Society Reviews · doi:10.1039/d2cs00931e · Cited by 417
Skin-inspired soft bioelectronic materials, devices and systems
Zhao, C., Park, J., Root, S. E., & Bao, Z. (2024) · Nature Reviews Bioengineering · doi:10.1038/s44222-024-00194-1 · Cited by 408
Self-citationZhang, Z., Wang, Z., Zhang, C., Yao, Z., Zhang, S., Wang, R., Tian, Z., Han, J., Chang, C., Lou, J., et al. (2024) · Advanced Materials · doi:10.1002/adma.202308453 · Cited by 309
Wang, C., He, T., Zhou, H., Zhang, Z., & Lee, C. (2023) · Bioelectronic Medicine · doi:10.1186/s42234-023-00118-1 · Cited by 295
“i - ii: NeuroString for chemical sensing in the gut; iii - iv: NeuroString for brain neural signals recording (Li et al. 2022) (See figure on next page.”
BackgroundInfluentialGreen Flexible Electronics: Natural Materials, Fabrication, and Applications
Hui, Z., Zhang, L., Ren, G., Sun, G., Yu, H., & Huang, W. (2023) · Advanced Materials · doi:10.1002/adma.202211202 · Cited by 287
Artificial intelligence-powered electronic skin
Xu, C., Solomon, S. A., & Gao, W. (2023) · Nature Machine Intelligence · doi:10.1038/s42256-023-00760-z · Cited by 259
“E-skin-based biochemical sensors have been widely applied to analyse molecular biomarkers (for example, electrolytes 44 , metabolites 4 , amino acids 10 , neurotransmitters 45 and proteins 46 ) in human bioflu-ids including sweat 4,10,13,47 , saliva 48 and interstitial fluids 49 .”
Rational Design of Flexible Zn-Based Batteries for Wearable Electronic Devices
Xiao, X., Zheng, Z., Zhong, X., Gao, R., Piao, Z., Jiao, M., & Zhou, G. (2023) · ACS Nano · doi:10.1021/acsnano.2c09509 · Cited by 236
Guo, Z., Lu, X., Wang, X., Li, X., Li, J., & Sun, J. (2023) · Advanced Materials · doi:10.1002/adma.202300286 · Cited by 232
Self-citationFlexible Organic Transistors for Biosensing: Devices and Applications
Song, J., Liu, H., Zhao, Z., Lin, P., & Yan, F. (2024) · Advanced Materials · doi:10.1002/adma.202300034 · Cited by 220
Flexible and Stretchable Light-Emitting Diodes and Photodetectors for Human-Centric Optoelectronics
Chang, S., Koo, J. H., Yoo, J., Kim, M. S., Choi, M. K., Kim, D.-H., & Song, Y. M. (2024) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00548 · Cited by 202
Wu, Z., Qiao, Z., Chen, S., Fan, S., Liu, Y., Qi, J., & Lim, C. T. (2024) · Communications Materials · doi:10.1038/s43246-024-00468-6 · Cited by 183
Self-citationConklin, B., Conley, B. M., Hou, Y., Chen, M., & Lee, K.-B. (2023) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2022.114636 · Cited by 45
Metadata
- Authors
- Li, J., Liu, Y., Yuan, L., Zhang, B., Bishop, E. S., Wang, K., Tang, J., Zheng, Y.-Q., Xu, W., Niu, S., Beker, L., Li, T. L., Chen, G., Diyaolu, M., Thomas, A.-L., Mottini, V., Tok, J. B.-H., Dunn, J. C. Y., Cui, B., Pașca, S. P., Cui, Y., Habtezion, A., Chen, X., & Bao, Z.
- Venue
- Nature
- Published
- 2022-06-01
- Volume
- 606
- Issue
- 7912
- Pages
- 94-101
- ISSN
- 0028-0836 (ISSN-L)
- 1476-4687
- OpenAlex
- W4281901178
- Cited by
- 443
- References
- 58
- FWCI
- 25.96
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.