The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Interstitial fluid-based wearable biosensors for minimally invasive healthcare and biomedical applications
Open accessAbstract
Interstitial fluid (ISF), a biological fluid rich in diverse biomarkers and analytes and similar to blood composition, has garnered significant attention as a valuable source of clinically relevant information. Consequently, ISF-based wearable biosensors are emerging as powerful tools for non-invasive and minimally invasive disease diagnosis, personalized medicine, and other healthcare and biomedical applications. This review provides a comprehensive overview of recent advancements in ISF-based biosensors, with a particular focus on wearable ISF sensors. We first offer insights into ISF biomarkers and sampling techniques and discuss recent ISF sensing strategies that encompass materials, fabrication methods, and sensing mechanisms. Then, we present a comprehensive overview of their applications. Finally, we address the challenges faced in this field and offer a forward-looking perspective on promising future directions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis
Gao, W., Emaminejad, S., Nyein, H. Y. Y., Challa, S., Chen, K., Peck, A., Fahad, H. M., Ota, H., Shiraki, H., Kiriya, D., et al. (2016) · Nature · doi:10.1038/nature16521 · Cited by 5,087 · cited 2×
“These easily accessible bio fl uids which include ISF 3,5,7 , tears 8,9 , saliva 10,11 , and sweat 12,13 were proposed and studied to evaluate both small (e.g. glucose, lactate, and amino acids 14 ) and large molecules (e.g. drugs 15 , proteins 16 , and hormones 17 ) biomarkers.”
Lee, H., Choi, T. K., Lee, Y. B., Cho, H. R., Ghaffari, R., Wang, L., Choi, H. J., Chung, T. D., Lu, N., Hyeon, T., et al. (2016) · Nature Nanotechnology · doi:10.1038/nnano.2016.38 · Cited by 1,802
A laser-engraved wearable sensor for sensitive detection of uric acid and tyrosine in sweat
Yang, Y., Song, Y., Bo, X., Min, J., Pak, O. S., Zhu, L., Wang, M., Tu, J., Kogan, A., Zhang, H., et al. (2020) · Nature Biotechnology · doi:10.1038/s41587-019-0321-x · Cited by 1,270
Wearable smart sensor systems integrated on soft contact lenses for wireless ocular diagnostics
Kim, J., Kim, M., Lee, M.-S., Kim, K., Ji, S., Kim, Y.-T., Park, J., Na, K., Bae, K.-H., Kyun Kim, H., et al. (2017) · Nature Communications · doi:10.1038/ncomms14997 · Cited by 951
Tattoo-Based Noninvasive Glucose Monitoring: A Proof-of-Concept Study
Bandodkar, A. J., Jia, W., Yardımcı, C., Wang, X., Ramirez, J., & Wang, J. (2015) · Analytical Chemistry · doi:10.1021/ac504300n · Cited by 700
Wearable salivary uric acid mouthguard biosensor with integrated wireless electronics
Kim, J., Imani, S., de Araujo, W. R., Warchall, J., Valdés-Ramírez, G., Paixão, T. R. L. C., Mercier, P. P., & Wang, J. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.07.039 · Cited by 678 · cited 1×
“These easily accessible bio fl uids which include ISF 3,5,7 , tears 8,9 , saliva 10,11 , and sweat 12,13 were proposed and studied to evaluate both small (e.g. glucose, lactate, and amino acids 14 ) and large molecules (e.g. drugs 15 , proteins 16 , and hormones 17 ) biomarkers.”
A Wearable Electrochemical Platform for Noninvasive Simultaneous Monitoring of Ca2+ and pH
Nyein, H. Y. Y., Gao, W., Shahpar, Z., Emaminejad, S., Challa, S., Chen, K., Fahad, H. M., Tai, L.-C., Ota, H., Davis, R. W., et al. (2016) · ACS Nano · doi:10.1021/acsnano.6b04005 · Cited by 669
Parlak, O., Keene, S. T., Marais, A., Curto, V. F., & Salleo, A. (2018) · Science Advances · doi:10.1126/sciadv.aar2904 · Cited by 603
Non-Invasive Blood Glucose Monitoring Technology: A Review
Tang, L., Chang, S. J., Chen, C.-J., & Liu, J.-T. (2020) · Sensors · doi:10.3390/s20236925 · Cited by 481
Wearable Electrochemical Glucose Sensors in Diabetes Management: A Comprehensive Review
Saha, T., Del Caño, R., Mahato, K., De la Paz, E., Chen, C., Ding, S., Yin, L., & Wang, J. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00078 · Cited by 442
Metadata
- Authors
- Wu, Z., Qiao, Z., Chen, S., Fan, S., Liu, Y., Qi, J., & Lim, C. T.
- Venue
- Communications Materials
- Published
- 2024-03-13
- Volume
- 5
- Issue
- 1
- ISSN
- 2662-4443 (ISSN-L)
- OpenAlex
- W4392762096
- Cited by
- 183
- References
- 23
- FWCI
- 19.22
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Interstitial fluid-based wearable biosensors for minimally invasive healthcare and biomedical applications. https://app.cochat.ai/papers/10.1038/s43246-024-00468-6
- The paper
- Wu, Z., Qiao, Z., Chen, S., Fan, S., Liu, Y., Qi, J., & Lim, C. T. (2024). Interstitial fluid-based wearable biosensors for minimally invasive healthcare and biomedical applications. Communications Materials. https://doi.org/10.1038/s43246-024-00468-6
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.