Adhesive anti-fibrotic interfaces on diverse organs
Open accessThe DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
Implanted biomaterials and devices face compromised functionality and efficacy in the long term owing to foreign body reactions and subsequent formation of fibrous capsules at the implant–tissue interfaces 1–4. Here we demonstrate that an adhesive implant–tissue interface can mitigate fibrous capsule formation in diverse animal models, including rats, mice, humanized mice and pigs, by reducing the level of infiltration of inflammatory cells into the adhesive implant–tissue interface compared to the non-adhesive implant–tissue interface. Histological analysis shows that the adhesive implant–tissue interface does not form observable fibrous capsules on diverse organs, including the abdominal wall, colon, stomach, lung and heart, over 12 weeks in vivo. In vitro protein adsorption, multiplex Luminex assays, quantitative PCR, immunofluorescence analysis and RNA sequencing are additionally carried out to validate the hypothesis. We further demonstrate long-term bidirectional electrical communication enabled by implantable electrodes with an adhesive interface over 12 weeks in a rat model in vivo. These findings may offer a promising strategy for long-term anti-fibrotic implant–tissue interfaces.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Moderated estimation of fold change and dispersion for RNA-seq data with DESeq2
Love, M. I., Huber, W., & Anders, S. (2014) · Genome Biology · doi:10.1186/s13059-014-0550-8 · Cited by 95,106
clusterProfiler: an R Package for Comparing Biological Themes Among Gene Clusters
Yu, G., Wang, L.-G., Han, Y., & He, Q.-Y. (2012) · OMICS: A Journal of Integrative Biology · doi:10.1089/omi.2011.0118 · Cited by 36,259
Cutadapt removes adapter sequences from high-throughput sequencing reads
Martin, M. (2011) · EMBnet.journal · doi:10.14806/ej.17.1.200 · Cited by 33,889 · cited 1×
“Read quality was evaluated using FastQC, and data were pre-processed with Cutadapt 35 for adaptor removal following best practices 36 .”
featureCounts: an efficient general purpose program for assigning sequence reads to genomic features
Liao, Y., Smyth, G. K., & Shi, W. (2014) · Bioinformatics · doi:10.1093/bioinformatics/btt656 · Cited by 27,219
Foreign body reaction to biomaterials
Anderson, J. M., Rodriguez, A., & Chang, D. T. (2008) · Seminars in Immunology · doi:10.1016/j.smim.2007.11.004 · Cited by 5,138
A survey of best practices for RNA-seq data analysis
Conesa, A., Madrigal, P., Tarazona, S., Gomez-Cabrero, D., Cervera, A., McPherson, A., Szcześniak, M. W., Gaffney, D. J., Elo, L. L., Zhang, X., et al. (2016) · Genome Biology · doi:10.1186/s13059-016-0881-8 · Cited by 2,794 · cited 1×
“Read quality was evaluated using FastQC, and data were pre-processed with Cutadapt 35 for adaptor removal following best practices 36 .”
Biological Responses to Materials
Anderson, J. M. (2001) · Annual Review of Materials Research · doi:10.1146/annurev.matsci.31.1.81 · Cited by 1,465 · cited 1×
“Foreign body reactions to implants are among the most critical challenges that undermine the long-term functionality and reliability of biomaterials and devices in vivo 1–4 .”
Zwitterionic hydrogels implanted in mice resist the foreign-body reaction
Zhang, L., Cao, Z., Bai, T., Carr, L., Ella-Menye, J.-R., Irvin, C., Ratner, B. D., & Jiang, S. (2013) · Nature Biotechnology · doi:10.1038/nbt.2580 · Cited by 1,035 · cited 3×
“On days 3, 7, 14, 28 and 84 post-implantation, the animals were euthanized using CO 2 inhalation.”
Cunningham, F., Achuthan, P., Akanni, W., Allen, J., Amode, M. R., Armean, I. M., Bennett, R., Bhai, J., Billis, K., Boddu, S., et al. (2019) · Nucleic Acids Research · doi:10.1093/nar/gky1113 · Cited by 925 · cited 1×
“2 transcriptome (Ensembl release 104) 37 was quantified with STAR 38 and featureCounts 39 .”
Veiseh, O., Doloff, J. C., Ma, M., Vegas, A. J., Tam, H. H., Bader, A. R., Li, J., Langan, E., Wyckoff, J., Loo, W. S., et al. (2015) · Nature Materials · doi:10.1038/nmat4290 · Cited by 897 · cited 1×
“…the formation of the fibrous capsule at the implant–tissue interface, various approaches have been developed, including drug-eluting coatings 12 , hydrophilic 13 or zwitterionic polymer coatings 14–16 , active surfaces 17,18 and controlling the stiffness 19 and/or size 20,21 of the implants.”
Nam, S., & Mooney, D. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.0c00798 · Cited by 764 · cited 1×
“This may be attributed to unstable long-term adhesion of the commercially available tissue adhesives with the tissue surface in vivo 27,28 .”
Tissue–electronics interfaces: from implantable devices to engineered tissues
Feiner, R., & Dvir, T. (2017) · Nature Reviews Materials · doi:10.1038/natrevmats.2017.76 · Cited by 595
Bochenek, M. A., Veiseh, O., Vegas, A. J., McGarrigle, J. J., Qi, M., Marchese, E., Omami, M., Doloff, J. C., Mendoza-Elias, J., Nourmohammadzadeh, M., et al. (2018) · Nature Biomedical Engineering · doi:10.1038/s41551-018-0275-1 · Cited by 367
Xie, X., Doloff, J. C., Yesilyurt, V., Sadraei, A., McGarrigle, J. J., Omami, M., Veiseh, O., Farah, S., Isa, D., Ghani, S., et al. (2018) · Nature Biomedical Engineering · doi:10.1038/s41551-018-0273-3 · Cited by 235
The Foreign Body Response Demystified
Chandorkar, Y., K, R., & Basu, B. (2019) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.8b00252 · Cited by 201 · cited 2×
“Foreign body reactions to implants are among the most critical challenges that undermine the long-term functionality and reliability of biomaterials and devices in vivo 1–4 .”
Linking the foreign body response and protein adsorption to PEG-based hydrogels using proteomics
Swartzlander, M. D., Barnes, C. A., Blakney, A. K., Kaar, J. L., Kyriakides, T. R., & Bryant, S. J. (2015) · Biomaterials · doi:10.1016/j.biomaterials.2014.11.026 · Cited by 190
Farah, S., Doloff, J. C., Müller, P., Sadraei, A., Han, H. J., Olafson, K., Vyas, K., Tam, H. H., Hollister-Lock, J., Kowalski, P. S., et al. (2019) · Nature Materials · doi:10.1038/s41563-019-0377-5 · Cited by 181 · cited 1×
“…the formation of the fibrous capsule at the implant–tissue interface, various approaches have been developed, including drug-eluting coatings 12 , hydrophilic 13 or zwitterionic polymer coatings 14–16 , active surfaces 17,18 and controlling the stiffness 19 and/or size 20,21 of the implants.”
Kolb, M., Bonniaud, P., Galt, T., Sime, P. J., Kelly, M. M., Margetts, P. J., & Gauldie, J. (2002) · American Journal of Respiratory Cell and Molecular Biology · doi:10.1165/ajrcmb.27.2.4674 · Cited by 168 · cited 1×
“Note that immunocompetent C57BL/6 mice are known to produce fibrosis and foreign body reactions similar to those observed in human patients 32 , and HuCD34-NCG humanized mice provide human-like immune responses 33 .”
Cited by
Biodegradable Medical Implants: Reshaping Future Medical Practice
Xia, B., Liu, Y., Xing, Y., Shi, Z., & Pan, X. (2025) · Advanced Science · doi:10.1002/advs.202508014 · Cited by 64
Metadata
- Authors
- Wu, J., Deng, J., Theocharidis, G., Sarrafian, T. L., Griffiths, L. G., Bronson, R. T., Veves, A., Chen, J., Yuk, H., & Zhao, X.
- Venue
- Nature
- Published
- 2024-05-22
- Volume
- 630
- Issue
- 8016
- Pages
- 360-367
- ISSN
- 0028-0836 (ISSN-L)
- 1476-4687
- OpenAlex
- W4398201203
- Cited by
- 186
- References
- 18
- FWCI
- 71.15
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).