Accessing analytes in biofluids for peripheral biochemical monitoring
The DOI matches its Crossref record; 87 of the 87 references it cites were found in a registry or an index.
Abstract
Peripheral biochemical monitoring involves the use of wearable devices for minimally invasive or noninvasive measurement of analytes in biofluids such as interstitial fluid, saliva, tears and sweat. The goal in most cases is to obtain measurements that serve as surrogates for circulating analyte concentrations in blood. Key technological developments to date include continuous glucose monitors, which use an indwelling sensor needle to measure glucose in interstitial fluid, and device-integrated sweat stimulation for continuous access to analytes in sweat. Further development of continuous sensing technologies through new electrochemical sensing modalities will be a major focus of future research. While there has been much investment in wearable technologies to sense analytes, less effort has been directed to understanding the physiology of biofluid secretion. Elucidating the underlying biology is crucial for accelerating technological progress, as the biofluid itself often presents the greatest challenge in terms of sample volumes, secretion rates, filtration, active analyte channels, variable pH and salinity, analyte breakdown and other confounding factors.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Larger polar molecules and charged ions or molecules move paracellularly during the process of sweat secretion”
From Physiological mechanisms determining eccrine sweat composition (2020) · cites this paper as Heikenfeld et al. 2019
In the citing paper
“Some recent papers have suggested a potential route of glucose transport that is paracellular in nature”
From Physiological mechanisms determining eccrine sweat composition (2020) · cites this paper as Heikenfeld et al. 2019
In the citing paper
“Sweat sensors are being developed that capture chloride, glucose, lactate, urea, creatinine, alcohol, pH and even heavy metals.”
From Skin sensors are the future of health care (2019) · cites this paper as [7]
In the citing paper
“Sweat contains many indicators relating to cell health and organ function (such as electrolytes), the immune system (cytokines) and drug interactions (metabolites).”
From Skin sensors are the future of health care (2019) · cites this paper as [7]
Citations
Cites
A review of saliva: Normal composition, flow, and function
Humphrey, S. P., & Williamson, R. T. (2001) · The Journal of Prosthetic Dentistry · doi:10.1067/mpr.2001.113778 · Cited by 2,400
Microneedles for drug and vaccine delivery
Kim, Y.-C., Park, J.-H., & Prausnitz, M. R. (2012) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2012.04.005 · Cited by 1,760
Wearable sensors: modalities, challenges, and prospects
Heikenfeld, J., Jajack, A., Rogers, J., Gutruf, P., Tian, L., Pan, T., Li, R., Khine, M., Kim, J., Wang, J., et al. (2018) · Lab on a Chip · doi:10.1039/c7lc00914c · Cited by 1,434
Self-citationPhysiology and function of the tight junction
Anderson, J. M., & Van Itallie, C. M. (2009) · Cold Spring Harbor Perspectives in Biology · doi:10.1101/cshperspect.a002584 · Cited by 1,059
Electrochemical Tattoo Biosensors for Real-Time Noninvasive Lactate Monitoring in Human Perspiration
Jia, W., Bandodkar, A. J., Valdés-Ramírez, G., Windmiller, J. R., Yang, Z., Ramírez, J., Chan, G., & Wang, J. (2013) · Analytical Chemistry · doi:10.1021/ac401573r · Cited by 862
Glucose Sensing for Diabetes Monitoring: Recent Developments
Bruen, D., Delaney, C., Florea, L., & Diamond, D. (2017) · Sensors · doi:10.3390/s17081866 · Cited by 777
Regulation of salivary gland function by autonomic nerves
Proctor, G. B., & Carpenter, G. H. (2007) · Autonomic Neuroscience · doi:10.1016/j.autneu.2006.10.006 · Cited by 734
Sonner, Z., Wilder, E., Heikenfeld, J., Kasting, G., Beyette, F., Swaile, D., Sherman, F., Joyce, J., Hagen, J., Kelley-Loughnane, N., et al. (2015) · Biomicrofluidics · doi:10.1063/1.4921039 · Cited by 724
Self-citationThe Performance and Usability of a Factory-Calibrated Flash Glucose Monitoring System
Bailey, T., Bode, B. W., Christiansen, M. P., Klaff, L. J., & Alva, S. (2015) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2014.0378 · Cited by 685
Wearable salivary uric acid mouthguard biosensor with integrated wireless electronics
Kim, J., Imani, S., de Araujo, W. R., Warchall, J., Valdés-Ramírez, G., Paixão, T. R. L. C., Mercier, P. P., & Wang, J. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.07.039 · Cited by 678
Research works printed but not linked: 1
- Bourne, G. H. & Danielli, J. F. International Review of Cytology Vol. 87 (Academic, 1984).
Cited by
Items 801–832 of 832
Jin, Y., Holman, J. B., Yu, Q., Chen, X., Sun, S., Hu, Y., Chen, J., Qiu, B., Ding, W., & Li, C. (2026) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2026.119066
Rakhmania, C. D. (2024) · Institutional Repositories DataBase (IRDB) · doi:10.34551/0002000827
Engineering Translational Biosensing Tools Forparkinson’s Disease
Terry, M. (2026) · UND Scholarly Commons (University of North Dakota)
Begam, S. M., Kadali, B., Botchu, B. B., Mandru, D., Peddiboina, M., & Varahagiri, P. (2026) · Journal of Pharma Insights and Research. · doi:10.69613/sbk9hq51
Esmaeildoost, F., Arshadi, S., Rahimi, F., Najafpour, M., chian, M. F., Sachlos, E., Leung, S. N., & Salahandish, R. (2026) · Advanced Healthcare Materials · doi:10.1002/adhm.71983
Drăgan, A.-M., Parrilla, M., Cambré, S., Domínguez‐Robles, J., Detamornrat, U., Donnelly, R. F., Oprean, R., Cristea, C., & Wael, K. D. (2023) · Zenodo (CERN European Organization for Nuclear Research) · doi:10.5281/zenodo.8400755
Development methodologies of wearable biosensors for personalized health monitoring
Cheng, X. (2023) · eScholarship (California Digital Library)
Components Of Wearable Biosensors: A Biochemical Perspective On Real - Time Health Monitoring
Sulthana, S., & P, R. V. (2026) · INTERNATIONAL JOURNAL OF RESEARCH AND ANALYTICAL REVIEWS · doi:10.56975/ijrar.v13i2.335928
Nawaz, H., Ramzan, N., Afzal, I., Gill, A. W., Chaudry, M. A. H., Qamar, B., & Sulman, A. (2026) · Physical Education Health and Social Sciences · doi:10.63163/jpehss.v4i2.1681
Converging Technologies and Future Outlook
Kurabayashi, K., Füredi, A. D., & Song, Y. (2026) · doi:10.1021/bk-2026-1539.ch008
Le, P. T., Yun, G., Hwang, T. S., Lee, H. W., Cho, H., Lee, J., & Lim, G. (2026) · Nature Communications · doi:10.1038/s41467-026-78755-8
BioPerspiration: A Wearable Sweat-Based Biosensing Platforms for Physiological Monitoring
N.Sriraam, Raamnath, K., Nandi, S., Prabakaran, A., & Chaithanya, S. (2026) · International Conference on Innovations in Mechanical, Robotics, Computing and Biomedical Engineering (ICIMRBE) · doi:10.1109/icimrbe70745.2026.11709946
A Review of Emerging Nanophotonic Biosensors and Their Expanding Applications
Tanwar, S. S., Sharma, U., Singh, R., & Sharma, S. (2025) · Asian Pacific Journal of Nursing and Health Sciences · doi:10.46811/apjnh/8.2.3
Mattos, G. J. (2026) · Archive ouverte UNIGE (University of Geneva) · doi:10.13097/archive-ouverte/unige:192117
From Signals to Decisions: Task-Oriented Wearable Sensing for Sports Performance and Athlete Health
Lv, K., Wu, Y., & Xue, J. (2026) · Sensors · doi:10.3390/s26227221
Gene-Edited Live Cell Sensor for Free Calcium
Sun, F., Lee, D. H., Gaj, T., & Cunningham, B. T. (2019) · Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ... · doi:10.1109/sensors43011.2019.8956634
Jia, N., Bouchard, A. D., Deng, T., de Oliveira, L. T., Bégin‐Drolet, A., & Greener, J. (2022) · ChemRxiv · doi:10.26434/chemrxiv-2022-cmpvm
Hybrid point-of-care devices for high-sensitivity visual detection of salivary biomarkers and drugs
Pomili, T., & Pompa, P. P. (2023) · IEEE Nanotechnology Materials and Devices Conference (NMDC) · doi:10.1109/nmdc57951.2023.10343643
Hileghem, L. V. (2023) · Lirias
Gold and Silver Nanoparticle Based Colorimetric Sensing Method
Huang, J. (2025) · UCL Discovery (University College London)
Conception d'un appareil de mesure par spectroscopie et cartouches microfluidiques
Daignault-Bouchard, A. (2023) · Corpus Université Laval (Université Laval)
Wu, Y.-A., Chen, I.-J., Chang, Y.-W., Ko, H.-Y., & Chiu, N. (2026) · Biophotonics in Point-of-Care · doi:10.1117/12.3100335
Reddy, D. O., Hassan, M., Graham, J. O., Viggers, J., Williams, K. E., Ellis, R. E., Covey, T. R., Shelley, J. T., & Oleschuk, R. D. (2026) · Micromachines · doi:10.3390/mi17050559
A Multi-Modal Electrochemical and Motion Sensing WearablePreprint
Philippou, G., & Casson, A. J. (2026) · Research Square · doi:10.21203/rs.3.rs-10041592/v1
Socio-psychological drivers of clothing behavior: A comprehensive review
Gautam, S., Sharma, D., & Rana, M. (2026) · International Journal of Advanced Biochemistry Research · doi:10.33545/26174693.2026.v10.i8su.9696
Titare, P. S., Dike, P., Thigale, M. H., Kakkar, M., Bachhav, V. S., & Rane, D. D. (2026) · Adolescencia e Saude · doi:10.67440/ahj.v21i6s.1744
Mixed Charge Monolayers Enable Multi-Week Continuous Analyte Monitoring in Whole Serum
Young, T., Rees, L., Truong, H., Smith, M., Demek, E., Watkins, Z., Schutte, S. C., Arroyo‐Currás, N., & Heikenfeld, J. C. (2026) · ACS Sensors · doi:10.1021/acssensors.6c03379
Self-citationBody-Coupled Organic Electrochemical Transistors for Imperceptible Skin Bioelectronics
Li, C., Zhong, S., Deng, J., Tao, X., Huang, S., Qiu, Y., Wang, W., & Wu, K. (2026) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.6c14607
Ultra-thin graphene/PEDOT:PSS wearable sensor for human emotion diagnosis
Antonova, I. V., Ivanov, A. I., Buzmakova, A. A., Черкасова, О. П., & Shavelkina, M. B. (2026) · Materials Research Bulletin · doi:10.1016/j.materresbull.2026.114551
Time-Resolved FRET Enables Self-Normalized Aptamer Sensing by Resolving State-Specific Signals
Gopalan, D., Eisenstein, M., & Soh, H. T. (2026) · Analytical Chemistry · doi:10.1021/acs.analchem.6c04771
Yan, Y., Veronica, A., Wang, C., Guo, Y., He, A., Gu, M., Zhang, L. F., Han, G., Cui, J. Q., Chandwaney, S. V., et al. (2026) · Science Advances · doi:10.1126/sciadv.aeg8698
Metadata
- Authors
- Heikenfeld, J., Jajack, A., Feldman, B., Granger, S. W., Gaitonde, S., Begtrup, G., & Katchman, B. A.
- Affiliations
- University of Cincinnati (US)
- Abbott Diabetes Care (United States) (US)
- Athenaeum of Ohio (US)
- Corresponding author
- Jajack, Andrew
- Venue
- Nature Biotechnology
- Published
- 2019-02-25
- Volume
- 37
- Issue
- 4
- Pages
- 407-419
- ISSN
- 0733-222X (ISSN-L)
- 1087-0156
- 1546-1696
- OpenAlex
- W2917130660
- Cited by
- 758
- References
- 87
- Citations by year
- 2026: 113 · 2025: 133 · 2024: 131 · 2023: 123 · 2022: 109 · 2021: 69 · 2020: 53 · 2019: 27
- FWCI
- 3.27
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Nature Biotechnology (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Israel Science Foundation
- Abbott Diabetes Care
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical Chemistry and Sensors
- Keywords
- wearable devices, interstitial fluid, saliva, sweat, tears, continuous glucose monitoring, electrochemical sensor, sensor design
- MeSH terms
- Wearable Electronic Devices, Adult, Biotechnology, Blood Glucose, Body Fluids, Female, Glucose, Humans, Male, Monitoring, Physiologic, Saliva, Sweat, Biosensing Techniques, Extracellular Fluid, Young Adult
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.