Accessing analytes in biofluids for peripheral biochemical monitoring
The DOI matches its Crossref record; 87 of the 87 references it cites were found in a registry or an index.
Abstract
Peripheral biochemical monitoring involves the use of wearable devices for minimally invasive or noninvasive measurement of analytes in biofluids such as interstitial fluid, saliva, tears and sweat. The goal in most cases is to obtain measurements that serve as surrogates for circulating analyte concentrations in blood. Key technological developments to date include continuous glucose monitors, which use an indwelling sensor needle to measure glucose in interstitial fluid, and device-integrated sweat stimulation for continuous access to analytes in sweat. Further development of continuous sensing technologies through new electrochemical sensing modalities will be a major focus of future research. While there has been much investment in wearable technologies to sense analytes, less effort has been directed to understanding the physiology of biofluid secretion. Elucidating the underlying biology is crucial for accelerating technological progress, as the biofluid itself often presents the greatest challenge in terms of sample volumes, secretion rates, filtration, active analyte channels, variable pH and salinity, analyte breakdown and other confounding factors.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Larger polar molecules and charged ions or molecules move paracellularly during the process of sweat secretion”
From Physiological mechanisms determining eccrine sweat composition (2020) · cites this paper as Heikenfeld et al. 2019
In the citing paper
“Some recent papers have suggested a potential route of glucose transport that is paracellular in nature”
From Physiological mechanisms determining eccrine sweat composition (2020) · cites this paper as Heikenfeld et al. 2019
In the citing paper
“Sweat sensors are being developed that capture chloride, glucose, lactate, urea, creatinine, alcohol, pH and even heavy metals.”
From Skin sensors are the future of health care (2019) · cites this paper as [7]
In the citing paper
“Sweat contains many indicators relating to cell health and organ function (such as electrolytes), the immune system (cytokines) and drug interactions (metabolites).”
From Skin sensors are the future of health care (2019) · cites this paper as [7]
Citations
Cites
A review of saliva: Normal composition, flow, and function
Humphrey, S. P., & Williamson, R. T. (2001) · The Journal of Prosthetic Dentistry · doi:10.1067/mpr.2001.113778 · Cited by 2,400
Microneedles for drug and vaccine delivery
Kim, Y.-C., Park, J.-H., & Prausnitz, M. R. (2012) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2012.04.005 · Cited by 1,760
Wearable sensors: modalities, challenges, and prospects
Heikenfeld, J., Jajack, A., Rogers, J., Gutruf, P., Tian, L., Pan, T., Li, R., Khine, M., Kim, J., Wang, J., et al. (2018) · Lab on a Chip · doi:10.1039/c7lc00914c · Cited by 1,434
Self-citationPhysiology and function of the tight junction
Anderson, J. M., & Van Itallie, C. M. (2009) · Cold Spring Harbor Perspectives in Biology · doi:10.1101/cshperspect.a002584 · Cited by 1,059
Electrochemical Tattoo Biosensors for Real-Time Noninvasive Lactate Monitoring in Human Perspiration
Jia, W., Bandodkar, A. J., Valdés-Ramírez, G., Windmiller, J. R., Yang, Z., Ramírez, J., Chan, G., & Wang, J. (2013) · Analytical Chemistry · doi:10.1021/ac401573r · Cited by 862
Glucose Sensing for Diabetes Monitoring: Recent Developments
Bruen, D., Delaney, C., Florea, L., & Diamond, D. (2017) · Sensors · doi:10.3390/s17081866 · Cited by 777
Regulation of salivary gland function by autonomic nerves
Proctor, G. B., & Carpenter, G. H. (2007) · Autonomic Neuroscience · doi:10.1016/j.autneu.2006.10.006 · Cited by 734
Sonner, Z., Wilder, E., Heikenfeld, J., Kasting, G., Beyette, F., Swaile, D., Sherman, F., Joyce, J., Hagen, J., Kelley-Loughnane, N., et al. (2015) · Biomicrofluidics · doi:10.1063/1.4921039 · Cited by 724
Self-citationThe Performance and Usability of a Factory-Calibrated Flash Glucose Monitoring System
Bailey, T., Bode, B. W., Christiansen, M. P., Klaff, L. J., & Alva, S. (2015) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2014.0378 · Cited by 685
Wearable salivary uric acid mouthguard biosensor with integrated wireless electronics
Kim, J., Imani, S., de Araujo, W. R., Warchall, J., Valdés-Ramírez, G., Paixão, T. R. L. C., Mercier, P. P., & Wang, J. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.07.039 · Cited by 678
Research works printed but not linked: 1
- Bourne, G. H. & Danielli, J. F. International Review of Cytology Vol. 87 (Academic, 1984).
Cited by
Items 701–800 of 832
Li, Z., Zhang, D., Zhang, W., & Zhang, H. (2025) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.5c01186 · Cited by 1
Xiong, J., Wu, L. L., Xiao, G., Ma, Y., Ran, R., Sun, W., Wang, W., Mao, C., Qiao, Y., & Lu, Z. (2024) · Cellulose · doi:10.1007/s10570-024-06065-7 · Cited by 1
Jabar, S. A., & Hasan, H. R. (2023) · Iraqi Journal of Cancer and Medical Genetics · doi:10.29409/ijcmg.v16i2.337 · Cited by 1
Freeman, D. M. E., Greenfield, B., Cunningham, C., Harrold, J. A., Kingdon, C., Nunn, N., Ming, D. K. Y., Lissauer, D. M., Holmes, A. H., & Merriel, A. (2025) · BMJ Innovations · doi:10.1136/bmjinnov-2025-001393 · Cited by 1
Porosity control of polylactic acid porous microneedles using microfluidic technology
Qin, B., Park, J., Jing, H., Bao, L., & Kim, B. (2022) · IEEE CPMT Symposium Japan (ICSJ) · doi:10.1109/icsj55786.2022.10034733 · Cited by 1
Fratus, M., & Alam, M. A. (2023) · International Electronic Conference on Chemical Sensors and Analytical Chemistry (CSAC) · doi:10.3390/csac2023-14906 · Cited by 1
Healing cascades and infections in wounds monitored using a wearable sensor of gaseous flux
Cho, S., Tan, A., Chen, Z., Pyun, K. R., Li, S., Yin, F., Zhang, A., Feldman, N., Neuhart, E. J., Moreno, A. D., et al. (2026) · doi:10.64898/2026.06.18.733171
Transport-Informed Sweat Glucose Sensing Toward Noninvasive Continuous Monitoring
Zhang, S., Zhang, Y., Fl, Y., Liu, Z., Zhong, J., & Cheng, H. (2026) · ACS Applied Electronic Materials · doi:10.1021/acsaelm.6c00993
Rathod, A. P. S., Kumawat, A., Mishra, P. K., Mirza, A., Kaushik, M., & Mishra, A. (2026) · Journal of Materials Science Materials in Electronics · doi:10.1007/s10854-026-18431-1
Yoon, S. J., Park, J. T., Yun, J. M., & Lee, Y. K. (2026) · Soft Science · doi:10.20517/ss.2025.125
Wenfeng, W., Jin, Y., Yiduo, H., Zihong, Z., Mao, L., Mao, H., Li, R., & Xiong, J. (2024) · SSRN Electronic Journal · doi:10.2139/ssrn.4714062
Structure design and application analysis of sweat detection device based on bionic microchannel
Liu, H., Lin, G., Li, W., & Shi, Y. (2025) · Microchemical Journal · doi:10.1016/j.microc.2025.114738
Naqvi, S. M. Z. A., Qunfeng, N., Tahir, M. N., Jiaqi, N., & Li, W. (2026) · Materials & Design · doi:10.1016/j.matdes.2026.116425
Self-Powered Triboelectric Biofluid Sensors for Early Disease Screening and Diagnosis: A Review
Zhang, Y., Wen, H., Huang, J., & Zhu, Q. (2026) · Nanomaterials · doi:10.3390/nano16171117
Microfluidic valves for wearable sweat analysis: a review
Tang, H., Yang, M., & Wang, X. (2026) · Analytical Sciences · doi:10.1007/s44211-026-00964-4
Qi, Q., Duan, J., Lei, Y., Zhou, S., Liu, Q. S., Wang, Q., Gao, N., Sun, W., Zhan, Z., & Wu, Y. (2026) · Biosensors · doi:10.3390/bios16090523
He, M., Huang, S., Zheng, S., Yao, C., Liu, Z., Huang, X., Li, X., Liang, B., Wang, J., Li, Y., et al. (2023) · Advanced Engineering Materials · doi:10.1002/adem.202300735
Preparation of the artificial “skin” uniform sweating simulation device
Zheng, H., Liu, M., Yang, X., Cao, Y. F., Nie, W., Wang, S., & Zhang, T. (2022) · Scientia Sinica Technologica · doi:10.1360/sst-2022-0114
Wet Interface Technologies for Wearable Sweat Sensors
Nagamine, K., & Tokito, S. (2024) · Springer eBooks · doi:10.1007/978-981-99-8122-9_10
Smart Textile Systems as Dynamic Platform for Human Hydration Monitoring
Zou, X., Zhang, Y., Forrester, S., & Xu, L. (2026) · Biomedical Materials & Devices · doi:10.1007/s44174-026-00780-4
Design and Evaluation of Smart Textile Systems for Sports Monitoring and Health Assessment
Deng, H., & Deng, P. (2026) · Textile & Leather Review · doi:10.31881/tlr.2026.5191
Gao, S., Wang, Y., Li, A., Chen, S., Che, H., Meng, X., Chen, Y., Lijuan, H., Bai, Y., & Lin, Y. (2026) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2026.119291
Toward a New Generation of AI‐Enabled Wearable Sensors
Yang, T., Zhu, H., Pan, Z., Yang, J., Liu, Y., Yan, W., Haick, H., & Wang, Y. (2026) · Rare Metals · doi:10.1002/rar2.70560
Zhang, Z., Addokhi, A., Hughes, K. A., Zang, H., Piqueras, M. D. C., Kuzmanović, U., Charles, R., Leung, L., Klapperich, C. M., Allen, K. N., et al. (2025) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2025.10.31.685570
Aerosol jet and 3D printed impedance-based wearable sensors for local sweating rate monitoring
Dong, K., Wen, H., Huang, F., Gao, Z., Cao, Y., Xu, X., Ye, Q., & Liu, Q. (2026) · Microchemical Journal · doi:10.1016/j.microc.2026.118496
Applications of Wearable Sweat Biosensors in Sports Activities with Real-World Cases
Yan, J., Shi, J., Zhang, Z., Yang, M., Zhang, M., & Wang, M. (2026) · Bioengineering · doi:10.3390/bioengineering13080906
Electrochemical analysis of biological fluids
Brown, M. S., Kelly, M., & Koh, A. (2024) · Elsevier eBooks · doi:10.1016/b978-0-323-99147-6.00003-x
Food‐Interfaced Bioelectronics for In Situ Molecular Food Profiling
Yeom, J., Khan, S. A., & Gao, W. F. (2026) · Advanced Materials · doi:10.1002/adma.75196
Chiriacò, M. S., Ferrara, F., & Primiceri, E. (2022) · MDPI eBooks · doi:10.3390/books978-3-0365-3415-2
Wireless and Wearable Biomarker Analysis
Lin, S., Wang, B., Shih, R. M., & Emaminejad, S. (2021) · Wiley eBooks · doi:10.1002/9781119683285.ch14
Nagamine, K., Sekine, T., & Tokito, S. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-822548-6.00077-7
Fully Integrated Self‐powered Sweat‐Sensing Platform
Song, Y., Gao, W. F., & Zhang, H. (2021) · Wiley eBooks · doi:10.1002/9783527833474.ch5
Gao, Y., Zhu, R., Han, T., Sheng, T., Liu, X., Zhou, M., Ding, Y., & Su, Y. (2025) · Chemical Engineering Journal · doi:10.1016/j.cej.2025.170800
Mary, X. A., Ashisha, G. R., Bhagavathsingh, J., Manimegalai, P., Karthik, C., & Salau, A. O. (2026) · Hybrid Advances · doi:10.1016/j.hybadv.2026.100603
Multifunctional Sweat Sensors Using Semiconductor Fibers Based on Two‐Dimensional Nanomaterials
Park, J. H., Park, J. W., Choi, M. S., Pang, S. U., Choe, J. S., Yu, T. S., Jang, K.-I., Kim, J., Chung, H. U., Kim, J. H., et al. (2026) · Small Structures · doi:10.1002/sstr.202500905
Low-Temperature Sintering Inks for Printed Bioelectronics: Materials, Mechanisms, and Emerging Ideas
Bera, A., Liu, F., Marander, M., Ortega, R., Malkawi, A. M. A., Dey, U. K., Sandhu, R., Collins, T. P., & Jiang, S. (2026) · Biosensors · doi:10.3390/bios16040206
Bioelectrocatalytic Evaluation of Redox Dynamics in Exercise Physiology
Ma, G., Wei, X., & Gang, T. (2026) · Electroanalysis · doi:10.1002/elan.70139
Laser-written high-entropy metal–oxy patch for non-enzymatic lactate–pH sweat sensing
Fan, L., Wang, J., Xin, Y., & Zhang, Z. D. (2026) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2026.119028
Wearable Iontophoretic Biosensing: From Active Sampling Principles to Analytical Validation
Ahmed, F., Song, J., Kim, S., Masud, & Kim, J. (2026) · Analytical Chemistry · doi:10.1021/acs.analchem.6c01565
Zuo, G., Jiang, D., Hou, P., Tang, P., Shen, B., Zhao, Y., & Zhou, H. (2026) · Advanced Functional Materials · doi:10.1002/adfm.78107
Choi, C., & Kim, H. (2026) · Journal of Sensor and Actuator Networks · doi:10.3390/jsan15050074
Shitanda, I., Fujisawa, T., Loew, N., Shirai, R., Imade, Y., OKAMOTO, Y., Yanagita, S., Watanabe, H., & Itagaki, M. (2026) · ACS Omega · doi:10.1021/acsomega.6c04240
Li, T., Pan, G., Wang, Y., Zou, X., & Yang, H. (2026) · Advanced Sensor Research · doi:10.1002/adsr.70209
Pang, X., Luo, K., Liu, W., & Qian, K. (2026) · EngMedicine · doi:10.1016/j.engmed.2026.100172
Healing cascades and infections in wounds monitored using a wearable sensor of gaseous flux
Kyung, C.-M., Tan, A., Chen, Z., Pyun, K. R., Li, S., Yin, F., Zhang, A., Feldman, N., Neuhart, E. J., Moreno, A. D., et al. (2026) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2613824123
Skin-Derived Non-Coding RNAs as Potential Biomarkers and Therapeutic Targets
Zen, J. L., Le, Q. M. N., Li, S., & Hanna, G. B. (2026) · Non-Coding RNA · doi:10.3390/ncrna12050038
Soft Materials for Implantable Biosensors for Humans
Ananthappan, P., Ramki, K., Jayalakshmi, M., Hashim, F. B., & Vasantha, V. S. (2025) · Wiley eBooks · doi:10.1002/9781394214143.ch13
Toshev, S., Zuhridinovna, J. D., Tastanova, G., Nurmatova, I., Latipov, I., & Ismoilov, O. (2026) · Clinical & Translational Oncology · doi:10.1007/s12094-026-04584-2
Cao, M., Yu, S., Yuan, S., Yang, Y., Zhang, H., Song, J., Yan, X., Liu, J., Wang, Y., Li, W., et al. (2026) · Science China Materials · doi:10.1007/s40843-026-4333-8
Smart materials enabling flexible bioelectronic sensing for decentralized monitoring
Slaughter, C., Slaughter, J., Slaughter, J., & Slaughter, G. E. (2026) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2026.119204
Microneedle technology for biological monitoring and diagnosis
Chen, Y., & Quan, G. (2026) · Elsevier eBooks · doi:10.1016/b978-0-443-45544-5.00011-7
Artificial Intelligence (AI)-Empowered Precision Clinical Diagnostics and Beyond
Shi, J., & Yang, M. (2026) · Advanced Clinical Engineering · doi:10.2738/ace.2026.0004
Zhu, B. (2021) · Springer eBooks · doi:10.1007/978-1-4614-6623-9_41-1
Sweat-based screening of biomarkers using an enzymatic bioelectrocatalytic approach
Michelraj, S., Mechoor, A., & Ganesh, V. (2023) · Elsevier eBooks · doi:10.1016/b978-0-443-19039-1.00014-6
Best practices for using biological data in psychological research
Hawn, S. E., Sinnott, S. M., Smith, A. K., Bourassa, K. J., Brick, L., Hemmings, S. M. J., Seedat, S., Javanbakht, A., Smith, L., Seligowski, A. V., et al. (2026) · Journal of Mood and Anxiety Disorders · doi:10.1016/j.xjmad.2026.100197
Lee, S., Kim, M., Lee, J., Choi, C., 류승엽, Yang, J., Kim, Y., Ahn, J., & Lee, W. (2026) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2026.141052
A colorimetric glucose sensor with gradient porous polyglycolic acid (PGA) microneedle array patch
Zhang, Y., Xue, Z., Qin, B., Wu, J., Jongho, P. A. R. K., Xu, C., Shen, S., Li, H., & Kim, B. (2026) · Biomedical Microdevices · doi:10.1007/s10544-026-00827-9
Pathade, G., Raut, A., & Sherje, A. P. (2026) · Electroanalysis · doi:10.1002/elan.70202
LCMS Measurement of Steroid Biomarkers Collected from Palmar Sweat.Preprint
Hyde, J., & Runyon, J. R. (2020) · ChemRxiv · doi:10.26434/chemrxiv.12931769.v1
A fluorescent microneedle patch for machine-learning-assisted in situ estradiol mapping
Lü, L., Xia, W., Wang, J., Ma, C., Wang, X., Cao, R., Jin, J., Yin, Z., & Wu, L. (2026) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2026.140887
Microneedle biosensors: from molecular recognition to intelligent diagnostics
He, L., Yan, Z., Zheng, W., Qi, L., Liu, J., & He, X. (2026) · Chemical Communications · doi:10.1039/d6cc04191d
Tortolini, C., Caprio, M., Degjoni, A., Lenzi, A., Isidori, A. M., & Antiochia, R. (2026) · Biosensors and Bioelectronics X · doi:10.1016/j.biosx.2026.100747
Self-powered analytical chemistry: Concept, functionality with circular and eco-design
Hussain, C. M., Hussain, G., & Keçili, R. (2026) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2026.119185
Geng, H., Li, S., Liang, C., Min, S. Q., Sun, X., Peng, Y., Ding, S., Wang, Z., Liu, Y., Liu, Q., et al. (2026) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2026.119363
A Review of 3D Printed CMOS Electrochemical Biosensors for Smart Liver Disease Diagnosis
Saju, S., Abishek, R., Dhurushanthini, K., Luxshiba, K., & Nithin, V. (2025) · International Conference on Electronics, Communication and Aerospace Technology (ICECA) · doi:10.1109/iceca66444.2025.11383048
Kong, L., Wang, F., Wen, H., Wang, C., Zhang, Z., Zheng, L., Liang, Z., Liu, Y., & Chen, P. (2026) · Science Advances · doi:10.1126/sciadv.aea3748
Shi, X., Zhang, Q., He, D., Wan, T., Guo, W., Mei, L., & Liu, R. (2025) · Advanced Materials Technologies · doi:10.1002/admt.202500371
Development of Doped Hybrid Xerogels as Optical Fibre Sensors for Environmental pH Monitoring
Rosales‐Reina, B., Whittaker, N. S., Elosúa, C., Reinoso, S., Sun, T., Grattan, K. T. V., & Garrido, J. J. (2025) · Journal of Lightwave Technology · doi:10.1109/jlt.2025.3649966
Closed‐Loop Bioelectronics: From Functional Materials to Autonomous Therapy
Shrikrishna, N. S., Prakashan, D., & Gandhi, S. (2026) · Advanced Materials · doi:10.1002/adma.75519
Polydopamine based ion-selective nanosensor for electrolyte sensing
Khan, M. D. H., Tang, Z., Coronel-Zegarra, A., Zhang, L., Merk, V. M., & Wang, R. (2026) · Microchimica Acta · doi:10.1007/s00604-026-07859-1
Advancing neonatal care through non-invasive biochemical monitoring and diagnostics
Son, H., Kim, D., Yeo, W. H., & Lim, H. (2026) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2026.119387
Gentile, F., Battista, E., Cardone, D., Perpetuini, D., Paolucci, T., Pesce, M., Alam, A., Vit, V., Bruno, L., Merla, A., et al. (2026) · ACS Omega · doi:10.1021/acsomega.6c05587
Zhou, Y., Li, S., He, L., Qi, L., Yin, G., Zhou, H., Long, W., Chen, Y., Wang, K., & He, X. (2026) · Talanta · doi:10.1016/j.talanta.2026.130836
Ternary Core–Shell NiCoMnPB-Based Microneedle Sensor for Continuous Detection of Creatinine
Chen, Y., Sun, H., & Shi, G. (2026) · Analytical Chemistry · doi:10.1021/acs.analchem.6c03703
Aptamer-based microneedle sensing platform for in vivo drug monitoring
Tsyban, Y., Shetty, S. S., Li, Y., Ibrahim, L. A., Sulaiman, D. A., Merzaban, J. S., & Salama, K. N. (2026) · Device · doi:10.1016/j.device.2026.101205
Printable inks for flexible healthcare sensors: From materials to device insights
Bokka, N., Padamurthy, A., Lanka, T. R., Pal, A., & Enaganti, P. K. (2026) · Journal of Science Advanced Materials and Devices · doi:10.1016/j.jsamd.2026.101282
Wearable Sensors for Physiological Monitoring: A Comprehensive Review
Gao, Z. (2026) · Theoretical and Natural Science · doi:10.54254/2753-8818/2026.au34966
Li, G., Peng, X., Guo, F., Ma, C., Deng, X., Wang, D., Ji, Y., Han, T., He, M., Zhang, D., et al. (2026) · Chemical Engineering Journal · doi:10.1016/j.cej.2026.179380
Liu, J., Jin, L., & Qu, X. (2026) · Microchemical Journal · doi:10.1016/j.microc.2026.118134
Panicker, L. R., Keerthanaa, M. R., & Goud, K. Y. (2024) · Springer eBooks · doi:10.1007/978-981-99-8122-9_7
Alroud, A. I., Hamid, F. A., Jamaluddin, J. E., & Razak, N. N. A. (2026) · Journal of Pioneering Medical Science · doi:10.47310/jpms2026150729
Tissue metabolism: fundamentals and advanced instrumental assessment
Владимирович, Д. В. (2026) · Progress in Biomedical Engineering · doi:10.1088/2516-1091/ae7861
Parihar, A., Sharma, Y., Arya, N., & Kanwar, R. K. (2026) · Elsevier eBooks · doi:10.1016/b978-0-443-36504-1.00010-4
Neuroenhancement in Military Personnel: Conceptual and Methodological Promises
Wester, B., Feltman, K. A., Greenwald, H., van Erp, J. B. F., Ohiri, K., Heaton, K. J., Hamilton, L., Beaudoin, M., Brunyé, T. T., Vartanian, O., et al. (2024) · TNO Repository
Flexible Electrochemical Sensors: Emerging Biomedical Applications and Future Perspectives
Fu, Y., Li, X., Rahmani, S., Chen, C., Du, D., Dongen, H. P. A. V., Qiu, K., & Lin, Y. (2026) · ECS Sensors Plus · doi:10.1149/2754-2726/ae8de6
Extraoral Detection of Biomarkers and Pathogens in Saliva: Comprehensive, Panoramic Review
Dyussupova, A., Ilyas, A., Boranova, A., Shevchenko, Y., Terzapulo, X., Seitkali, A., Gaipov, A., Filchakova, O., & Bukasov, R. (2026) · Biosensors · doi:10.3390/bios16060345
Wang, J., Zheng, H., Li, W., Zhu, W., Li, J., Chen, Y., Wang, M., Chen, Y., Hou, J., Li, D., et al. (2026) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2026.141194
Photonic Integrated Circuit (PIC) Platform for Sensing Biomarkers
Morales, J. M., Bickford, J. R., Cho, P. S., & Pellegrino, P. M. (2022) · Optical Sensors and Sensing Congress · doi:10.1364/sensors.2022.sm3e.1
Development and Characterization of Enzymatic Sensors for Real-Time Monitoring of Levodopa
Probst, D. (2024) · Carolina Digital Repository (University of North Carolina at Chapel Hill) · doi:10.17615/4zmn-j364
Advancing non-invasive diagnosis through biomarker detection in biofluids
Tang, H., Sun, G., Lu, C., Pouri, H., Panta, R., Chen, T. L., & Zhang, J. (2026) · Nanotechnology · doi:10.1088/1361-6528/ae9d2c
Koiwa, D., Haga, Y., & Tsuruoka, N. (2026) · IEEE Sensors Letters · doi:10.1109/lsens.2026.3710854
Facile and Flexible Glucose Sensors Based on Copper Thin Films
ALAM, M. M. (2023) · MacSphere (McMaster University) · doi:10.71548/18293
Estrategias para el diseño y caracterización de dispositivos analíticos colorimétricos
Ramos-Lorente, C. E. (2024) · Institutional Repository of the University of Granada (University of Granada) · Cited by 1
Owolabi, O., & Owoseni, A. T. (2026) · Iconic Research and Engineering Journals · doi:10.64388/irev10i1-1719751
Alsarhan, A., Hanumanthayya, M., Khdir, M. M., Panigrahi, R., Bansal, P., Thukaral, B., Kumar, N., & Shayesteh, O. H. (2026) · Microchemical Journal · doi:10.1016/j.microc.2026.119984
Programmable Self-Regenerating Bioelectronic Devices
Mahmud, A. (2023) · TSpace (University of Toronto)
Kumar, S., & Singh, N. K. (2026) · Elsevier eBooks · doi:10.1016/b978-0-443-36504-1.00005-0
Mendes, L. F. (2023) · Digital Library of Theses and Dissertations (Universidade de São Paulo) · doi:10.11606/t.46.2023.tde-11122023-154239
Almofeez, L. I., Islam, M. S., Ambagahawaththa, T. S., & Khan, Y. (2026) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.64898/2026.10.31.763347
Fang, F., Shi, Z., Tang, L., Tian, Y., Li, L., Yu, F., He, L., Lu, Y., Cao, Y., & Liu, Q. (2026) · Nano Energy · doi:10.1016/j.nanoen.2026.112521
Metadata
- Authors
- Heikenfeld, J., Jajack, A., Feldman, B., Granger, S. W., Gaitonde, S., Begtrup, G., & Katchman, B. A.
- Affiliations
- University of Cincinnati (US)
- Abbott Diabetes Care (United States) (US)
- Athenaeum of Ohio (US)
- Corresponding author
- Jajack, Andrew
- Venue
- Nature Biotechnology
- Published
- 2019-02-25
- Volume
- 37
- Issue
- 4
- Pages
- 407-419
- ISSN
- 0733-222X (ISSN-L)
- 1087-0156
- 1546-1696
- OpenAlex
- W2917130660
- Cited by
- 758
- References
- 87
- Citations by year
- 2026: 113 · 2025: 133 · 2024: 131 · 2023: 123 · 2022: 109 · 2021: 69 · 2020: 53 · 2019: 27
- FWCI
- 3.27
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Nature Biotechnology (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Israel Science Foundation
- Abbott Diabetes Care
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical Chemistry and Sensors
- Keywords
- wearable devices, interstitial fluid, saliva, sweat, tears, continuous glucose monitoring, electrochemical sensor, sensor design
- MeSH terms
- Wearable Electronic Devices, Adult, Biotechnology, Blood Glucose, Body Fluids, Female, Glucose, Humans, Male, Monitoring, Physiologic, Saliva, Sweat, Biosensing Techniques, Extracellular Fluid, Young Adult
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.