Accessing analytes in biofluids for peripheral biochemical monitoring
The DOI matches its Crossref record; 87 of the 87 references it cites were found in a registry or an index.
Abstract
Peripheral biochemical monitoring involves the use of wearable devices for minimally invasive or noninvasive measurement of analytes in biofluids such as interstitial fluid, saliva, tears and sweat. The goal in most cases is to obtain measurements that serve as surrogates for circulating analyte concentrations in blood. Key technological developments to date include continuous glucose monitors, which use an indwelling sensor needle to measure glucose in interstitial fluid, and device-integrated sweat stimulation for continuous access to analytes in sweat. Further development of continuous sensing technologies through new electrochemical sensing modalities will be a major focus of future research. While there has been much investment in wearable technologies to sense analytes, less effort has been directed to understanding the physiology of biofluid secretion. Elucidating the underlying biology is crucial for accelerating technological progress, as the biofluid itself often presents the greatest challenge in terms of sample volumes, secretion rates, filtration, active analyte channels, variable pH and salinity, analyte breakdown and other confounding factors.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Larger polar molecules and charged ions or molecules move paracellularly during the process of sweat secretion”
From Physiological mechanisms determining eccrine sweat composition (2020) · cites this paper as Heikenfeld et al. 2019
In the citing paper
“Some recent papers have suggested a potential route of glucose transport that is paracellular in nature”
From Physiological mechanisms determining eccrine sweat composition (2020) · cites this paper as Heikenfeld et al. 2019
In the citing paper
“Sweat sensors are being developed that capture chloride, glucose, lactate, urea, creatinine, alcohol, pH and even heavy metals.”
From Skin sensors are the future of health care (2019) · cites this paper as [7]
In the citing paper
“Sweat contains many indicators relating to cell health and organ function (such as electrolytes), the immune system (cytokines) and drug interactions (metabolites).”
From Skin sensors are the future of health care (2019) · cites this paper as [7]
Citations
Cites
A review of saliva: Normal composition, flow, and function
Humphrey, S. P., & Williamson, R. T. (2001) · The Journal of Prosthetic Dentistry · doi:10.1067/mpr.2001.113778 · Cited by 2,400
Microneedles for drug and vaccine delivery
Kim, Y.-C., Park, J.-H., & Prausnitz, M. R. (2012) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2012.04.005 · Cited by 1,760
Wearable sensors: modalities, challenges, and prospects
Heikenfeld, J., Jajack, A., Rogers, J., Gutruf, P., Tian, L., Pan, T., Li, R., Khine, M., Kim, J., Wang, J., et al. (2018) · Lab on a Chip · doi:10.1039/c7lc00914c · Cited by 1,434
Self-citationPhysiology and function of the tight junction
Anderson, J. M., & Van Itallie, C. M. (2009) · Cold Spring Harbor Perspectives in Biology · doi:10.1101/cshperspect.a002584 · Cited by 1,059
Electrochemical Tattoo Biosensors for Real-Time Noninvasive Lactate Monitoring in Human Perspiration
Jia, W., Bandodkar, A. J., Valdés-Ramírez, G., Windmiller, J. R., Yang, Z., Ramírez, J., Chan, G., & Wang, J. (2013) · Analytical Chemistry · doi:10.1021/ac401573r · Cited by 862
Glucose Sensing for Diabetes Monitoring: Recent Developments
Bruen, D., Delaney, C., Florea, L., & Diamond, D. (2017) · Sensors · doi:10.3390/s17081866 · Cited by 777
Regulation of salivary gland function by autonomic nerves
Proctor, G. B., & Carpenter, G. H. (2007) · Autonomic Neuroscience · doi:10.1016/j.autneu.2006.10.006 · Cited by 734
Sonner, Z., Wilder, E., Heikenfeld, J., Kasting, G., Beyette, F., Swaile, D., Sherman, F., Joyce, J., Hagen, J., Kelley-Loughnane, N., et al. (2015) · Biomicrofluidics · doi:10.1063/1.4921039 · Cited by 724
Self-citationThe Performance and Usability of a Factory-Calibrated Flash Glucose Monitoring System
Bailey, T., Bode, B. W., Christiansen, M. P., Klaff, L. J., & Alva, S. (2015) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2014.0378 · Cited by 685
Wearable salivary uric acid mouthguard biosensor with integrated wireless electronics
Kim, J., Imani, S., de Araujo, W. R., Warchall, J., Valdés-Ramírez, G., Paixão, T. R. L. C., Mercier, P. P., & Wang, J. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.07.039 · Cited by 678
Determination of tear volume and tear flow.
Mishima, S., Gasset, A. R., Klyce, S. D., & BAUM, J. L. (1966) · PubMed · Cited by 607
The physiology of salivary secretion
Proctor, G. B. (2016) · Periodontology 2000 · doi:10.1111/prd.12116 · Cited by 583
Correlation Between Sweat Glucose and Blood Glucose in Subjects with Diabetes
Moyer, J., Wilson, D., Finkelshtein, I., Wong, B., & Potts, R. (2012) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2011.0262 · Cited by 570
Contact Lens Sensors in Ocular Diagnostics
Farandos, N. M., Yetisen, A. K., Monteiro, M. J., Lowe, C. R., & Yun, S. H. (2015) · Advanced Healthcare Materials · doi:10.1002/adhm.201400504 · Cited by 466
Foudeh, A. M., Fatanat Didar, T., Veres, T., & Tabrizian, M. (2012) · Lab on a Chip · doi:10.1039/c2lc40630f · Cited by 457
Real-time measurement of small molecules directly in awake, ambulatory animals
Arroyo-Currás, N., Somerson, J., Vieira, P. A., Ploense, K. L., Kippin, T. E., & Plaxco, K. W. (2017) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1613458114 · Cited by 451
POLIOMYELITIS AND TONSILLECTOMY
(1955) · Medical Journal of Australia · doi:10.5694/j.1326-5377.1955.tb45053.x · Cited by 420
Dynamics and functions of tight junctions
Steed, E., Balda, M. S., & Matter, K. (2010) · Trends in Cell Biology · doi:10.1016/j.tcb.2009.12.002 · Cited by 418
Baker, L. B. (2017) · Sports Medicine · doi:10.1007/s40279-017-0691-5 · Cited by 403
A Concept of Negative Interstitial Pressure Based on Pressures in Implanted Perforated Capsules
GUYTON, A. C., Frank, M., & Abernathy, B. (1963) · Circulation Research · doi:10.1161/01.res.12.4.399 · Cited by 383
The measurement of hormones in saliva: Possibilities and pitfalls
Vining, R. F., & McGinley, R. A. (1987) · Journal of Steroid Biochemistry · doi:10.1016/0022-4731(87)90297-4 · Cited by 338
Composition of interstitial fluid
Fogh-Andersen, N., Altura, B. M., Altura, B. T., & Siggaard-Andersen, O. (1995) · Clinical Chemistry · doi:10.1093/clinchem/41.10.1522 · Cited by 309
Non‐invasive Analyte Access and Sensing through Eccrine Sweat: Challenges and Outlook circa 2016
Heikenfeld, J. (2016) · Electroanalysis · doi:10.1002/elan.201600018 · Cited by 294
Self-citationLactate in human sweat: a critical review of research to the present day
Derbyshire, P. J., Barr, H., Davis, F., & Higson, S. P. J. (2012) · The Journal of Physiological Sciences · doi:10.1007/s12576-012-0213-z · Cited by 280
SENSITIVE ASSAYS FOR VIRAL ANTIBODIES IN SALIVA: AN ALTERNATIVE TO TESTS ON SERUM
Parry, J. V., Perry, K. R., & Mortimer, P. P. (1987) · The Lancet · doi:10.1016/s0140-6736(87)92737-1 · Cited by 280
Do Salivary Antibodies Reliably Reflect Both Mucosal and Systemic Immunity?
BRANDTZAEG, P. (2007) · Annals of the New York Academy of Sciences · doi:10.1196/annals.1384.012 · Cited by 261
Extraction and biomolecular analysis of dermal interstitial fluid collected with hollow microneedles
Miller, P. R., Taylor, R. M., Tran, B. Q., Boyd, G., Glaros, T., Chavez, V. H., Krishnakumar, R., Sinha, A., Poorey, K., Williams, K. P., et al. (2018) · Communications Biology · doi:10.1038/s42003-018-0170-z · Cited by 258
Human glandular salivas: their separate collection and analysis
Veerman, E. C. I., van den Keybus, P. A. M., Vissink, A., & Amerongen, A. V. N. (1996) · European Journal of Oral Sciences · doi:10.1111/j.1600-0722.1996.tb00090.x · Cited by 253
Salivary markers of inflammation in response to acute stress
Slavish, D. C., Graham-Engeland, J. E., Smyth, J. M., & Engeland, C. G. (2015) · Brain, Behavior, and Immunity · doi:10.1016/j.bbi.2014.08.008 · Cited by 250
Protein levels in nonstimulated and stimulated tears of normal human subjects.
Fullard, R. J., & Snyder, C. (1990) · PubMed · Cited by 249
Protein Binding: Do We Ever Learn?
Zeitlinger, M. A., Derendorf, H., Mouton, J. W., Cars, O., Craig, W. A., Andes, D., & Theuretzbacher, U. (2011) · Antimicrobial Agents and Chemotherapy · doi:10.1128/aac.01433-10 · Cited by 249
Salivary cortisone is a potential biomarker for serum free cortisol
Perogamvros, I., Keevil, B. G., Ray, D. W., & Trainer, P. J. (2010) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2010-1215 · Cited by 222
Cizza, G., Marques, A. H., Eskandari, F., Christie, I. C., Torvik, S., Silverman, M. N., Phillips, T. M., & Sternberg, E. M. (2008) · Biological Psychiatry · doi:10.1016/j.biopsych.2008.05.035 · Cited by 208
Trends in Nanomaterial-Based Non-Invasive Diabetes Sensing Technologies
Makaram, P., Owens, D., & Aceros, J. (2014) · Diagnostics · doi:10.3390/diagnostics4020027 · Cited by 200
Successful application of large microneedle patches by human volunteers
Ripolin, A., Quinn, J., Larrañeta, E., Vicente-Perez, E. M., Barry, J., & Donnelly, R. F. (2017) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2017.02.011 · Cited by 193
Focus on Methodology: Salivary bioscience and research on adolescence: An integrated perspective
Granger, D. A., Fortunato, C. K., Beltzer, E. K., Virag, M., Bright, M. A., & Out, D. (2012) · Journal of Adolescence · doi:10.1016/j.adolescence.2012.01.005 · Cited by 182
Design, Development, and Evaluation of a Novel Microneedle Array-based Continuous Glucose Monitor
Jina, A., Tierney, M. J., Tamada, J. A., McGill, S., Desai, S., Chua, B., Chang, A., & Christiansen, M. (2014) · Journal of Diabetes Science and Technology · doi:10.1177/1932296814526191 · Cited by 176
Salivary cytokines as biomarkers of periodontal diseases
Jaedicke, K. M., Preshaw, P. M., & Taylor, J. J. (2016) · Periodontology 2000 · doi:10.1111/prd.12117 · Cited by 171
Matrix metalloproteinases and periodontal diseases
Sapna, G., Gokul, S., & Bagri‐Manjrekar, K. (2014) · Oral Diseases · doi:10.1111/odi.12159 · Cited by 170
Hauke, A., Simmers, P., Ojha, Y. R., Cameron, B. D., Ballweg, R., Zhang, T., Twine, N., Brothers, M., Gomez, E., & Heikenfeld, J. (2018) · Lab on a Chip · doi:10.1039/c8lc01082j · Cited by 156
Self-citationChoi, J., Xue, Y., Xia, W., Ray, T. R., Reeder, J. T., Bandodkar, A. J., Kang, D., Xu, S., Huang, Y., & Rogers, J. A. (2017) · Lab on a Chip · doi:10.1039/c7lc00525c · Cited by 146
Christiansen, M. P., Klaff, L. J., Brazg, R., Chang, A. R., Levy, C. J., Lam, D., Denham, D. S., Atiee, G., Bode, B. W., Walters, S. J., et al. (2018) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2017.0142 · Cited by 146
Ship, J. A., & Fischer, D. J. (1997) · The Journals of Gerontology Series A: Biological Sciences and Medical Sciences · doi:10.1093/gerona/52a.5.m310 · Cited by 141
Diameters of the main excretory ducts of the adult human submandibular and parotid gland
Zenk, J., Hosemann, W. G., & Iro, H. (1998) · Oral Surgery Oral Medicine Oral Pathology Oral Radiology and Endodontology · doi:10.1016/s1079-2104(98)90294-3 · Cited by 137
The Determination of Lipids and Proteins in Suction Blister Fluid
Vermeer, B. J., Reman, F. C., & van Gent, C. M. (1979) · Journal of Investigative Dermatology · doi:10.1111/1523-1747.ep12531833 · Cited by 135
Marques-Deak, A., Cizza, G., Eskandari, F., Torvik, S., Christie, I. C., Sternberg, E. M., & Phillips, T. M. (2006) · Journal of Immunological Methods · doi:10.1016/j.jim.2006.07.011 · Cited by 129
Villiger, M., Stoop, R., Vetsch, T., Hohenauer, E., Pini, M., Clarys, P., Pereira, F., & Clijsen, R. (2017) · European Journal of Clinical Nutrition · doi:10.1038/ejcn.2017.136 · Cited by 125
Comparative study of the concentration of salivary and blood glucose in type 2 diabetic patients
Vasconcelos, A. C. U., Soares, M. S. M., Almeida, P. C., & Soares, T. C. (2010) · Journal of Oral Science · doi:10.2334/josnusd.52.293 · Cited by 123
Personalized medicine: an update of salivary biomarkers for periodontal diseases
Korte, D. L., & Kinney, J. (2016) · Periodontology 2000 · doi:10.1111/prd.12103 · Cited by 118
Jia, M., Chew, W. M., Feinstein, Y., Skeath, P., & Sternberg, E. M. (2016) · The Analyst · doi:10.1039/c5an02387d · Cited by 113
Simmers, P., Li, S. K., Kasting, G. B., & Heikenfeld, J. C. (2017) · Journal of Dermatological Science · doi:10.1016/j.jdermsci.2017.10.013 · Cited by 107
Self-citationTowards a simple, saliva-based test for the detection of oral cancer.
Wong, D. T. (2006) · Expert Review of Molecular Diagnostics · doi:10.1586/14737159.6.3.267 · Cited by 97
Zhang, W., Du, Y., & Wang, M. L. (2015) · Sensing and Bio-Sensing Research · doi:10.1016/j.sbsr.2015.04.006 · Cited by 94
A modified anaerobic method of sweat collection
Boysen, T. C., Yanagawa, S., Sato, F., & Sato, K. (1984) · Journal of Applied Physiology · doi:10.1152/jappl.1984.56.5.1302 · Cited by 91
Sonner, Z., Wilder, E., Gaillard, T., Kasting, G., & Heikenfeld, J. (2017) · Lab on a Chip · doi:10.1039/c7lc00364a · Cited by 89
Self-citationGottås, A., Øiestad, E. L., Boix, F., Vindenes, V., Ripel, Å., Thaulow, C. H., & Mørland, J. G. (2013) · British Journal of Pharmacology · doi:10.1111/bph.12305 · Cited by 87
Eccrine Sweat as a Biofluid for Profiling Immune Biomarkers
Katchman, B. A., Zhu, M., Blain Christen, J., & Anderson, K. S. (2018) · PROTEOMICS – Clinical Applications · doi:10.1002/prca.201800010 · Cited by 86
Self-citationEngler, R., Routh, T. L., & Lucisano, J. Y. (2018) · Clinical Diabetes · doi:10.2337/cd17-0053 · Cited by 84
Lactate and Ammonia Concentration in Blood and Sweat During Incremental Cycle Ergometer Exercise
Ament, W., Huizenga, J., Mook, G., Gips, C., & Verkerke, C. J. (1997) · International Journal of Sports Medicine · doi:10.1055/s-2007-972592 · Cited by 79
The Fall and Rise of Tear Albumin Levels: A Multifactorial Phenomenon
Eden, G. R., Mann, A., & Tighe, B. J. (2013) · The Ocular Surface · doi:10.1016/j.jtos.2013.03.001 · Cited by 72
A new approach to the assessment of anaerobic metabolism: measurement of lactate in saliva.
Segura, R., Javierre, C., Ventura, J. L., Lizarraga, M. A., Campos, B., & Garrido, E. (1996) · British Journal of Sports Medicine · doi:10.1136/bjsm.30.4.305 · Cited by 71
TEAR FLOW IN NORMAL HUMAN EYES. DETERMINATION BY MEANS OF RADIOISOTOPE AND GAMMA CAMERA
Sørensen, T. L., & Jensen, F. T. (1979) · Acta Ophthalmologica · doi:10.1111/j.1755-3768.1979.tb00504.x · Cited by 61
Effects of High and Low Blood Lactate Concentrations on Sweat Lactate Response
Green, J. M., Bishop, P. A., Muir, I. H., McLester Jr, J. R., & Heath, H. E. (2000) · International Journal of Sports Medicine · doi:10.1055/s-2000-8483 · Cited by 60
Modeling Glucose Transport From Systemic Circulation to Sweat
La Count, T. D., Jajack, A., Heikenfeld, J., & Kasting, G. B. (2019) · Journal of Pharmaceutical Sciences · doi:10.1016/j.xphs.2018.09.026 · Cited by 60
Self-citationNanoduct® sweat testing for rapid diagnosis in newborns, infants and children with cystic fibrosis
Desax, M.-C., Ammann, R. A., Hammer, J., Schoeni, M. H., & Barben, J. (2007) · European Journal of Pediatrics · doi:10.1007/s00431-007-0485-0 · Cited by 56
Vairo, D., Bruzzese, L., Marlinge, M., Fuster, L., Adjriou, N., Kipson, N., Brunet, P., Cautela, J., Jammes, Y., Mottola, G., et al. (2017) · Scientific Reports · doi:10.1038/s41598-017-12211-y · Cited by 54
Feasibility of Factory Calibration for Subcutaneous Glucose Sensors in Subjects With Diabetes
Hoss, U., Budiman, E. S., Liu, H., & Christiansen, M. P. (2014) · Journal of Diabetes Science and Technology · doi:10.1177/1932296813511747 · Cited by 53
Measurement of tissue cortisol levels in patients with severe burns: a preliminary investigation
Cohen, J., Deans, R., Dalley, A., Lipman, J., Roberts, M. S., & Venkatesh, B. (2009) · Critical Care · doi:10.1186/cc8184 · Cited by 43
Peng, R., Sonner, Z., Hauke, A., Wilder, E., Kasting, J., Gaillard, T., Swaille, D., Sherman, F., Mao, X., Hagen, J., et al. (2016) · Lab on a Chip · doi:10.1039/c6lc01013j · Cited by 43
Self-citationOpen nanofluidic films with rapid transport and no analyte exchange for ultra-low sample volumes
Twine, N. B., Norton, R. M., Brothers, M. C., Hauke, A., Gomez, E. F., & Heikenfeld, J. (2018) · Lab on a Chip · doi:10.1039/c8lc00186c · Cited by 43
Self-citationDiagnosing peri-implant disease using the tongue as a 24/7 detector
Ritzer, J., Lühmann, T., Rode, C., Pein-Hackelbusch, M., Immohr, I., Schedler, U., Thiele, T., Stübinger, S., Rechenberg, B. V., Waser-Althaus, J., et al. (2017) · Nature Communications · doi:10.1038/s41467-017-00340-x · Cited by 40
Ramalingam, K., Ahmed Mujib, B. R., Sarkar, A., Sathya, S., Bastian, B., & Kallapur, B. (2013) · Journal of Natural Science Biology and Medicine · doi:10.4103/0976-9668.117006 · Cited by 39
The human eccrine sweat gland: Structure, function and disorders
Bovell, D. (2015) · Journal of Local and Global Health Science · doi:10.5339/jlghs.2015.5 · Cited by 39
Kiang, T. K. L., & Ensom, M. H. H. (2015) · Clinical Pharmacokinetics · doi:10.1007/s40262-015-0321-z · Cited by 37
Enhancing glucose flux into sweat by increasing paracellular permeability of the sweat gland
Jajack, A., Brothers, M., Kasting, G., & Heikenfeld, J. (2018) · PLOS ONE · doi:10.1371/journal.pone.0200009 · Cited by 35
Self-citationDetection of Salivary Insulin Following Low versus High Carbohydrate Meals in Humans
Myette‐Côté, É., Baba, K., Brar, R., & Little, J. P. (2017) · Nutrients · doi:10.3390/nu9111204 · Cited by 34
Dye Clearance and Eccrine Sweat Secretion in Human Skin*
Hurley, H. J., & Witkowski, J. A. (1961) · Journal of Investigative Dermatology · doi:10.1038/jid.1961.44 · Cited by 32
Branson, B. M. (2004) · PubMed · Cited by 20
The sweat of patients with atopic dermatitis contains specific IgE antibodies to inhalant allergens
JUNG, K., Schlenvoigt, G., Ladwig, K., Herrmann, D. B. J., Moths, C., Linse, R., & Neumann, C. (1996) · Clinical and Experimental Dermatology · doi:10.1111/j.1365-2230.1996.tb00120.x · Cited by 18
Jajack, A. J., Stamper, I., Gomez, E. F., Brothers, M. C., Begtrup, G., & Heikenfeld, J. C. (2019) · PLoS ONE · doi:10.1371/journal.pone.0210286 · Cited by 16
Self-citationFDA Approves OraQuick for Use in Saliva
Branson, B. M. (2004) · Journal watch · doi:10.1056/ac200405010000009 · Cited by 15
Cinética do lactato salivar e sanguíneo em resposta à potência máxima no cicloergômetro
Oliveira, L. D. S., de Oliveira, S. F. M., Manchado-Gobatto, F. D. B., & Costa, M. D. C. (2015) · Brazilian Journal of Kinanthropometry and Human Performance · doi:10.5007/1980-0037.2015v17n5p565 · Cited by 13
Cooke, I. M., BEVILL, R. F., Nelson, D. R., & KORITZ, G. D. (1996) · PubMed · Cited by 13
The non-histone protein pattern of rat brain during ontogenesis
Olpe, H. R., Hahn, H., & Honegger, C. G. (1973) · Cellular and Molecular Life Sciences · doi:10.1007/bf01944760 · Cited by 9
Hellquist, H. B., & Skálová, A. (2014) · Springer eBooks · doi:10.1007/978-3-540-46915-5_1 · Cited by 5
Transdermal Microfluidic Continuous Monitoring Systems
Cunningham, D. D. (2009) · Wiley eBooks · doi:10.1002/9780470567319.ch7 · Cited by 3
Saga, Z., Rana, R., Minhas, L. A., & Mubarik, A. (2012) · Pakistan Armed Forces Medical Journal · Cited by 2
Research works printed but not linked: 1
- Bourne, G. H. & Danielli, J. F. International Review of Cytology Vol. 87 (Academic, 1984).
Cited by
Technology Roadmap for Flexible Sensors
Luo, Y., Abidian, M. R., Ahn, J.-H., Akinwande, D., Andrews, A. M., Antonietti, M., Bao, Z., Berggren, M., Berkey, C. A., Bettinger, C. J., et al. (2023) · ACS Nano · doi:10.1021/acsnano.2c12606 · Cited by 1,383
End-to-end design of wearable sensors
Ates, H. C., Nguyen, P. Q., Gonzalez-Macia, L., Morales-Narváez, E., Güder, F., Collins, J. J., & Dincer, C. (2022) · Nature Reviews Materials · doi:10.1038/s41578-022-00460-x · Cited by 1,306
A laser-engraved wearable sensor for sensitive detection of uric acid and tyrosine in sweat
Yang, Y., Song, Y., Bo, X., Min, J., Pak, O. S., Zhu, L., Wang, M., Tu, J., Kogan, A., Zhang, H., et al. (2020) · Nature Biotechnology · doi:10.1038/s41587-019-0321-x · Cited by 1,270
A wearable electrochemical biosensor for the monitoring of metabolites and nutrients
Wang, M., Yang, Y., Min, J., Song, Y., Tu, J., Mukasa, D., Ye, C., Xu, C., Heflin, N., McCune, J. S., et al. (2022) · Nature Biomedical Engineering · doi:10.1038/s41551-022-00916-z · Cited by 896
Device integration of electrochemical biosensors
Wu, J., Liu, H., Chen, W., Ma, B., & Ju, H. (2023) · Nature Reviews Bioengineering · doi:10.1038/s44222-023-00032-w · Cited by 895
Metadata
- Authors
- Heikenfeld, J., Jajack, A., Feldman, B., Granger, S. W., Gaitonde, S., Begtrup, G., & Katchman, B. A.
- Affiliations
- University of Cincinnati (US)
- Abbott Diabetes Care (United States) (US)
- Athenaeum of Ohio (US)
- Corresponding author
- Jajack, Andrew
- Venue
- Nature Biotechnology
- Published
- 2019-02-25
- Volume
- 37
- Issue
- 4
- Pages
- 407-419
- ISSN
- 0733-222X (ISSN-L)
- 1087-0156
- 1546-1696
- OpenAlex
- W2917130660
- Cited by
- 758
- References
- 87
- Citations by year
- 2026: 113 · 2025: 133 · 2024: 131 · 2023: 123 · 2022: 109 · 2021: 69 · 2020: 53 · 2019: 27
- FWCI
- 3.27
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Nature Biotechnology (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Israel Science Foundation
- Abbott Diabetes Care
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical Chemistry and Sensors
- Keywords
- wearable devices, interstitial fluid, saliva, sweat, tears, continuous glucose monitoring, electrochemical sensor, sensor design
- MeSH terms
- Wearable Electronic Devices, Adult, Biotechnology, Blood Glucose, Body Fluids, Female, Glucose, Humans, Male, Monitoring, Physiologic, Saliva, Sweat, Biosensing Techniques, Extracellular Fluid, Young Adult
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.