Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 165

The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.

Kilohertz frame-rate two-photon tomography

Open access
Kazemipour, Abbas, Novak, Ondrej, Flickinger, Daniel, Marvin, Jonathan S., Abdelfattah, Ahmed S., King, Jonathan, Borden, Philip M., Kim, Jeong Jun, Al-Abdullatif, Sarah H., Deal, Parker E., Miller, Evan W., Schreiter, Eric R., Druckmann, Shaul, Svoboda, Karel, Looger, Loren L., Podgorski, Kaspar·2019·Nature Methods

Abstract

Point-scanning two-photon microscopy enables high-resolution imaging within scattering specimens such as the mammalian brain, but sequential acquisition of voxels fundamentally limits its speed. We developed a two-photon imaging technique that scans lines of excitation across a focal plane at multiple angles and computationally recovers high-resolution images, attaining voxel rates of over 1 billion Hz in structured samples. Using a static image as a prior for recording neural activity, we imaged visually evoked and spontaneous glutamate release across hundreds of dendritic spines in mice at depths over 250 µm and frame rates over 1 kHz. Dendritic glutamate transients in anesthetized mice are synchronized within spatially contiguous domains spanning tens of micrometers at frequencies ranging from 1–100 Hz. We demonstrate millisecond-resolved recordings of acetylcholine and voltage indicators, three-dimensional single-particle tracking and imaging in densely labeled cortex. Our method surpasses limits on the speed of raster-scanned imaging imposed by fluorescence lifetime. A two-photon computed tomography approach, called scanned line angular projection microscopy, enables high-speed imaging at over 1 kHz frame rates, as demonstrated for glutamate imaging in the in vivo mouse brain.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/s41592-019-0493-9

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 10 references

Cited by

See all 165

Metadata

Authors
Kazemipour, A., Novak, O., Flickinger, D., Marvin, J. S., Abdelfattah, A. S., King, J., Borden, P. M., Kim, J. J., Al-Abdullatif, S. H., Deal, P. E., Miller, E. W., Schreiter, E. R., Druckmann, S., Svoboda, K., Looger, L. L., & Podgorski, K.
Venue
Nature Methods
Published
2019-07-29
Volume
16
Issue
8
Pages
778-786
ISSN
  • 1548-7091 (ISSN-L)
  • 1548-7105
OpenAlex
W2965378607
Cited by
165
References
10
FWCI
10.25
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Kilohertz frame-rate two-photon tomography. https://app.cochat.ai/papers/10.1038/s41592-019-0493-9
The paper
Kazemipour, A., Novak, O., Flickinger, D., Marvin, J. S., Abdelfattah, A. S., King, J., Borden, P. M., Kim, J. J., Al-Abdullatif, S. H., Deal, P. E., Miller, E. W., Schreiter, E. R., Druckmann, S., Svoboda, K., Looger, L. L., & Podgorski, K. (2019). Kilohertz frame-rate two-photon tomography. Nature Methods. https://doi.org/10.1038/s41592-019-0493-9

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.