MIMIC-IV, a freely accessible electronic health record dataset
Open accessThe DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index; 15 of the 20 sources its claims cite were checked for support.
Abstract
Digital data collection during routine clinical practice is now ubiquitous within hospitals. The data contains valuable information on the care of patients and their response to treatments, offering exciting opportunities for research. Typically, data are stored within archival systems that are not intended to support research. These systems are often inaccessible to researchers and structured for optimal storage, rather than interpretability and analysis. Here we present MIMIC-IV, a publicly available database sourced from the electronic health record of the Beth Israel Deaconess Medical Center. Information available includes patient measurements, orders, diagnoses, procedures, treatments, and deidentified free-text clinical notes. MIMIC-IV is intended to support a wide array of research studies and educational material, helping to reduce barriers to conducting clinical research.
Overview
CoChat Summary
## TL;DR
MIMIC-IV is a publicly available, deidentified electronic health record database from Beth Israel Deaconess Medical Center designed to support research, education, and technology development. It covers hospital and ICU care from 2008–2019 and adds modular structured data plus free-text clinical notes.
## Key findings
- The database includes patient measurements, orders, diagnoses, procedures, treatments, and deidentified free-text clinical notes, and is available through PhysioNet.
- The clinical cohort includes patients admitted to the emergency department or an ICU between 2008–2019; after exclusions, the authors linked 65,805 of 150,832 unique individuals (43.6%) to Massachusetts state death records.
- The paper reports that 51,022/65,803 (77.5%) of the successful death-record links were exact matches on last name, date of birth, and social security number; 11,634/65,803 (17.7%) were exact last name and date of birth plus approximate first name.
- MIMIC-IV was designed to be backward compatible with MIMIC-III while minimizing processing and organizing data into three modules: hosp, icu, and note.
## Methods
- Collaborative database construction from BIDMC clinical data, transformed and deidentified for release under IRB waiver and data use agreement; the process had three steps: acquisition, transformation, and deidentification.
- Sample/data: all patients admitted to the emergency department or an ICU at BIDMC between 2008–2019, excluding patients younger than 18 at first visit or on a protected list; external coding systems and Massachusetts death records were added.
- Main analysis/workflow: custom SQL scripts to restructure data into relational modules, plus custom linkage algorithms for out-of-hospital mortality and deidentification algorithms for HIPAA identifiers and free text; validation used integrity, consistency, and deidentification checks.
## Limitations
- The paper states that out-of-hospital mortality is only available through linkage to state death records, and deaths are censored at one year from last hospital discharge, so null death dates only indicate survival up to that point.
- The text makes evident that some data are incomplete or unevenly available across modules and time periods (for example, eMAR was deployed hospital-wide only by 2016, and the note module contains only discharge summaries and radiology reports); this is an evident coverage limitation from the text.
- The paper notes that clinical data are “sporadic and noisy,” reflecting routine care rather than research collection; this is a general data-quality limitation stated in the background.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Figures




Verification
Claims the paper makes
13 Valid · 3 Not valid · 3 Not checked · 110 Own results and interpretations
Every source the paper cites for this claim was checked and supports it.
In the paper
“Finally, we combined two published algorithms for removing PHI from free-text17,18.”
§ MIMIC-IV, a freely accessible electronic health record dataset > Methods > Deidentification
What the sources say
- Supportedcites [17] Neamatullah I Automated de-identification of free-text medical records BMC medical informatics and decision making 2008 8 1 17 10.1186/1472-6947-8-32 18652655 PMC2526997 source
The Methods sections describe this paper's published algorithm for identifying and removing PHI from free-text medical records. The citing authors' statement that they combined two algorithms describes their own method; this citation identifies one of the algorithms. (LLM, conf=0.92)
- Supportedcites [18] Johnson, A. E. W., Bulgarelli, L. & Pollard, T. J. Deidentification of free-text medical records using pre-trained bidirectional transformers. In Proceedings of the ACM Conference on Health, Inference, and Learning, 214–221 (2020). PMC8330601 34350426 source
The Introduction (page not available in our copy) presents this paper’s BERT model for deidentifying free-text health records and describes measuring how much PHI it removes. The citation can therefore identify one of the two published algorithms; this source need not establish that the citing authors combined them. (LLM, conf=0.91)
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
Every source the paper cites for this claim was checked and supports it.
In the paper
“Due to data quality concerns regarding the Social Security Death Master File (SSDMF)13, we did not attempt to link patients to the SSDMF for determining out-of-hospital mortality.”
§ MIMIC-IV, a freely accessible electronic health record dataset > Methods > Acquisition
What the sources say
- Supportedcites [13] Levin MA Lin H-M Prabhakar G McCormick PJ Egorova NN Alive or dead: Validity of the social security administration death master file after 2011 Health Serv Res 2019 51 24 33 10.1111/1475-6773.13069 PMC6338290 30520023 source
The Discussion states that the Death Master File is no longer a reliable single source for mortality data, including out-of-hospital deaths. The decision not to link patients is the citing authors’ own methodological choice; the citation supports the data-quality concern motivating it. (LLM, conf=0.93)
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“To support research that spans the periods of MIMIC-III (2002–2008) and MIMIC-IV (2008–2019), we have published the MIMIC-III Clinical Database CareVue subset22.”
§ MIMIC-IV, a freely accessible electronic health record dataset > Data Records > Building on earlier versions of MIMIC
What the sources say
- Partly supportedcites [22] Johnson AEW Pollard TJ Mark RG 2022 R. G. Mimic-iii clinical database carevue subset (version 1.4) PhysioNet 10.13026/8a4q-w170 sourceExperimental — accuracy not yet measured
The Abstract says the subset was provided to simplify combining MIMIC-III with MIMIC-IV, and the publication record identifies the released dataset. However, the Background and Methods give the CareVue period as 2001–2008, not the claim’s 2002–2008; the Background confirms MIMIC-IV’s 2008–2019 period. (LLM, conf=0.84)
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Partly supported
In the paper
“Access to MIMIC-IV is provided via PhysioNet19.”
§ MIMIC-IV, a freely accessible electronic health record dataset > Data Records
What the sources say
- Not checked — no full text of the sourcecites [19] Goldberger AL Physiobank, physiotoolkit, and physionet: components of a new research resource for complex physiologic signals circulation 2000 101 e215 e220 10.1161/01.CIR.101.23.e215 10851218 source
- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper states — it cites no source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“the d_icd_diagnoses and d_icd_procedures tables contain all codes which were valid at any point during the 2008–2019 time period.”
§ MIMIC-IV, a freely accessible electronic health record dataset > Data Records > Hospital module (hosp)
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
29 more claims
Create a free account to see all 129 claims and every source verdict.
- Probably not a substantial claim. 84
- It may state two separate claims as one. 30
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“We conducted a study using the publicly available MIMIC-IV dataset, which comprises 431,231 unique hospital admissions from 299,712 patients admitted to an ICU or the ED of the Beth Israel Deaconess Medical Center in Boston, Massachusetts27.”
From DRG-LLaMA : tuning LLaMA model to predict diagnosis-related group for hospitalized patients (2024) · cites this paper as [27]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“For instance, the MIMIC-IV [148] includes a limited range of modalities, including clinical notes, medical images (chest x-ray Digital Imaging and Communications in Medicine [DICM] images), and time series (diagnostic electrocardiogram and patient records), making it a valuable but constrained resource for training medical M-LLMs.”
From Multimodal Large Language Models in Health Care: Applications, Challenges, and Future Outlook. (2024) · cites this paper as [148]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Existing multimodal medical data sets available for public use [84,85,148] are often relatively small in scale and demand the consolidation of numerous resources.”
From Multimodal Large Language Models in Health Care: Applications, Challenges, and Future Outlook. (2024) · cites this paper as [148]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“- MIMIC-IV: A comprehensive, de-identified EHR dataset supporting tasks such as summarization, question answering, and document retrieval [17].”
From Retrieval-Augmented Generation (RAG) in Healthcare: A Comprehensive Review (2025) · cites this paper as [17]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“In order to build agents that are grounded in medically relevant situations, we use a random sample of diagnostic questions from the US Medical Licensing Exam (USMLE), from deidentified electronic health records (MIMIC-IV)16, and from the New England Journal of Medicine (NEJM) case challenges.”
From AgentClinic: a multimodal benchmark for tool-using clinical AI agents (2026) · cites this paper as [16]
4 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Goldberger, A. L., Amaral, L. A. N., Glass, L., Hausdorff, J. M., Ivanov, P. C., Mark, R. G., Mietus, J. E., Moody, G. B., Peng, C.-K., & Stanley, H. E. (2000) · Circulation · doi:10.1161/01.cir.101.23.e215 · Cited by 14,809
Self-citationMIMIC-III, a freely accessible critical care database
Johnson, A. E. W., Pollard, T. J., Shen, L., Lehman, L.-W. H., Feng, M., Ghassemi, M., Moody, B., Szolovits, P., Anthony Celi, L., & Mark, R. G. (2016) · Scientific Data · doi:10.1038/sdata.2016.35 · Cited by 8,141 · cited 1×
“More recently, MIMIC-III was published in 2015 and significantly expanded MIMIC-II, containing data for over 40,000 patients 3 .”
MethodSelf-citationPollard, T. J., Johnson, A. E. W., Raffa, J. D., Celi, L. A., Mark, R. G., & Badawi, O. (2018) · Scientific Data · doi:10.1038/sdata.2018.178 · Cited by 1,993 · cited 2×
“0 comprises of 200,859 stays at ICUs and step-down units across 208 hospitals in the continental United States 4 .”
BackgroundSelf-citationSaeed, M., Villarroel, M., Reisner, A. T., Clifford, G., Lehman, L.-W., Moody, G., Heldt, T., Kyaw, T. H., Moody, B., & Mark, R. G. (2011) · Critical Care Medicine · doi:10.1097/ccm.0b013e31820a92c6 · Cited by 1,162
Self-citationBest Practices for Scientific Computing
Wilson, G., Aruliah, D. A., Brown, C. T., Chue Hong, N. P., Davis, M., Guy, R. T., Haddock, S. H. D., Huff, K. D., Mitchell, I. M., Plumbley, M. D., et al. (2014) · PLoS Biology · doi:10.1371/journal.pbio.1001745 · Cited by 723 · cited 1×
“The creation of MIMIC-IV followed best practices in scientific computing 23 .”
MethodJohnson, A., Bulgarelli, L., Pollard, T., Gow, B., Moody, B., Horng, S., Celi, L. A., & Mark, R. (2024) · PhysioNet · doi:10.13026/07hj-2a80 · Cited by 524
Self-citationJohnson, A., Bulgarelli, L., Pollard, T., Horng, S., Celi, L. A., & Mark, R. (2023) · PhysioNet · doi:10.13026/s6n6-xd98 · Cited by 524
Self-citationEarly prediction of circulatory failure in the intensive care unit using machine learning
Hyland, S. L., Faltys, M., Hüser, M., Lyu, X., Gumbsch, T., Esteban, C., Bock, C., Horn, M., Moor, M., Rieck, B., et al. (2020) · Nature Medicine · doi:10.1038/s41591-020-0789-4 · Cited by 477 · cited 1×
“The HiRID database contains high-resolution data for almost 34,000 admissions between 2008–2016 at Bern University Hospital in Switzerland 6,7 .”
BackgroundThe MIMIC Code Repository: enabling reproducibility in critical care research
Johnson, A. E. W., Stone, D. J., Celi, L. A., & Pollard, T. J. (2018) · Journal of the American Medical Informatics Association · doi:10.1093/jamia/ocx084 · Cited by 442 · cited 1×
“The MIMIC Code Repository was originally created for MIMIC-III to enable researchers to share and reuse code 24 .”
MethodSelf-citationAutomated de-identification of free-text medical records
Neamatullah, I., Douglass, M. M., Lehman, L.-W. H., Reisner, A., Villarroel, M., Long, W. J., Szolovits, P., Moody, G. B., Mark, R. G., & Clifford, G. D. (2008) · BMC Medical Informatics and Decision Making · doi:10.1186/1472-6947-8-32 · Cited by 413
Self-citation
Cited by
Items 3,201–3,269 of 3,269
Hoyt, G., Chatterjee, N., Davis, Z. N., Battaglia, F., & Basu, P. (2026) · Cureus · doi:10.7759/cureus.117173 · Cited by 1
Ramamoorthy, S. (2026) · doi:10.1109/icsist70215.2026.11706332
“The MIMIC-III and MIMIC-IV datasets, released by MIT, contain de-identified critical care records that are valuable to AI risk prediction models [5], [6].”
Shao, L., Li, Y., Wang, L., & Sun, W. (2026) · medRxiv · doi:10.64898/2026.09.28.26364145
Padmavathi, B., & Vempati, R. (2026) · International Conference on Secure Information Systems and Technologies (ICSIST) · doi:10.1109/icsist70215.2026.11706357
“Four publicly available healthcare datasets (MIMIC-IV [24], eICU Collaborative Research Database [25], UCI Heart Disease Dataset [26] and Pima Indians Diabetes Dataset [27]) are used to evaluate the performance and generalisation ability of the proposed Multi-View Hybrid Deep Learning Framework.”
Zhao, R., & Yang, S. (2026) · Frontiers in Oncology · doi:10.3389/fonc.2026.1814886
Tran, V.-T., Doan, T.-N., & Tran, S.-T. (2026) · Research Square · doi:10.21203/rs.3.rs-10801506/v1
Toppin, P. J., Correia, M. D. T., Chang, Y., Adhikari, L., McLaverty, B. P., & Natarajan, A. (2026) · Intensive Care Medicine Experimental · doi:10.1186/s40635-026-00972-8
How are researchers using MIMIC? A sampling-based methods review
Kenarangi, T., Barnett, A. G., Suen, J. Y., & White, N. M. (2026) · International Journal of Medical Informatics · doi:10.1016/j.ijmedinf.2026.106744
Yeo, Y. H., Que, L., Zhang, M., Zu, J., Wu, Y., Chiang, D. J., Chen, T., Shi, Y., He, Y., Wu, F., et al. (2026) · eGastroenterology · doi:10.1136/egastro-2026-100463 · Cited by 1
Wang, X., Gao, Y., Shi, Q., Ma, C., & Liu, Y. (2026) · Science Progress · doi:10.1177/00368504261492494
Yuan, Z., Zhao, L., Geng, H., et al. (2026) · Science Progress · doi:10.1177/00368504261495210
A decision analytics framework for critical care escalation using electronic health records
Deif, M. A., Shwedeh, F., Hafez, M., & Khishe, M. (2026) · Decision Analytics Journal · doi:10.1016/j.dajour.2026.100751
Xu, J., Li, M., Wang, Z., Jiang, L., Lin, X., Shang, X., & Wang, X. (2026) · Frontiers in Medicine · doi:10.3389/fmed.2026.1900968
Li, O. M., Li, Y., & Li, S. X. T. (2026) · Cureus · doi:10.7759/cureus.117234
Soni, S., Alex, S., Reddy, R. V., et al. (2026) · International Conference on Software and Computer Applications (ICSCA) · doi:10.1145/3801619.3801653
“Research making use of EHRs like MIMIC-IV confirms the predictive power of combining standard laboratory indices (e.g., lipid panels, glucose, renal function) with cardiac-specific high-sensitivity markers (e.g., Troponin, NT-proBNP) for classifying CAD severity [3].”
Shi, L., Sun, Z., Zhang, Y., Zhuang, H., & Ma, J. (2026) · Research Square · doi:10.21203/rs.3.rs-10912857/v1
İşleyen, H. B., & Okuyan, E. (2026) · Kocaeli Üniversitesi Sağlık Bilimleri Dergisi · doi:10.30934/kusbed.1948243
Lee, H. Y., An, G., Jeong, Y., Schenck, E. J., Ryu, H. G., Pickering, B. W., Herasevich, V., Diedrich, D. A., Moon, S., Yang, H.-L., et al. (2026) · Journal of Intensive Care · doi:10.1186/s40560-026-00947-7
READ: Reasoning Like a Cardiologist for Contactless Arrhythmia Diagnosis
Lyu, R., Feng, H., Zhou, A., Ma, H., Zheng, M., Meng, X., Duan, J., Wang, J., Zheng, M., & Shao, C. (2026) · Proceedings of the ACM on Interactive Mobile Wearable and Ubiquitous Technologies · doi:10.1145/3831993 · Cited by 1
Maimaiti, Y., Guo, Z., Tian, Y., Lu, P., Nannan, W., Wang, S., Xu, H., Chu, H., & Wang, Y. (2026) · Research Square · doi:10.21203/rs.3.rs-11025140/v1
Picheta, P., & Deniziak, S. R. (2026) · SoftwareX · doi:10.1016/j.softx.2026.103083
Liu, L., Huang, Z., Gui, B., Xu, L., Liu, Y., Wang, Y., Zhang, W., Luo, H., & Zhang, X. (2026) · Frontiers in Neurology · doi:10.3389/fneur.2026.1864288
Xia, X., & Xie, Z. (2026) · medRxiv · doi:10.64898/2026.09.29.26364303
shao, L., Li, Y., Xu, C., Tai, H., Wang, L., & Shi, J. (2026) · Journal of Intensive Care Medicine · doi:10.1177/08850666261493365 · Cited by 1
Zhang, Y., Wang, X., Wang, Q., Chen, G., & Zhang, L. (2026) · Journal of Critical Care · doi:10.1016/j.jcrc.2026.155759
Mu, Y., Tang, H., Zeng, Y., Wang, Q., Huang, T., Li, W., Wu, X., & Pi, S. (2026) · Frontiers in Medicine · doi:10.3389/fmed.2026.1915095
Zhang, J.-F., Mo, Q.-Y., Liu, J.-H., Zhang, Y.-H., Cai, Z.-Y., Duan, X.-Y., Jin, T.-R., Zhu, Y.-N., Lyu, J., & Zhang, X.-S. (2026) · Journal of the American Association of Nurse Practitioners · doi:10.1097/jxx.0000000000001374
STREAM: A data-driven framework for physiological state monitoring in ICU patients
Namvar, A., Ram, S., Labaki, W. W., Galbán, S., Lugogo, N. L., & Galbán, C. J. (2026) · PLOS Digital Health · doi:10.1371/journal.pdig.0001753 · Cited by 1
Data-reflector: an agentic exploratory data analysis platform for researchers
Sabounchi, M., Hazare, N. S., Capone, C., Jangda, M., Oh, W., Jayaraman, P., Gupta, S., Sawant, A., Kuschner, Z., Parchure, P., et al. (2026) · JAMIA Open · doi:10.1093/jamiaopen/ooag194
A survey of LLM reasoning in healthcare and medicine: Individual modeling and collaborative agents
Lin, Q., Xiao, L., Pu, B., Shi, K., Du, Y., Xu, J., He, K., Zhao, S., Zhang, J., Cambria, E., et al. (2026) · Information Fusion · doi:10.1016/j.inffus.2026.104827 · Cited by 7
CardioKGImpute: A Knowledge-Graph-Guided Imputation of Multivariate ICU Time Series
Barros, G., Froede, L., Pimenta, L. F., Machado, B., Meira, W., Lacerda, A., BARROS, A., & Pappa, G. (2026) · Lecture notes in computer science · doi:10.1007/978-3-032-39904-5_17
İşleyen, H. B., Yavuz, S. T., Bulut, S., Kızkapan, F., Alioglu, C., Sozen, A. A., & KHANMOHAMMADİ, M. (2026) · Echo Research and Practice · doi:10.1186/s44156-026-00139-x
“1 and MIMIC-IV-ECHO, both available through PhysioNet [6–8].”
Ji, W., Wang, G., Wang, Z., et al. (2026) · Science Progress · doi:10.1177/00368504261494961
Wang, L., Yu, Y., Peng, C., Xu, Q., Zhang, Y., li, Y., & Li, L. (2026) · Research Square · doi:10.21203/rs.3.rs-11192403/v1
Kanithi, P., Pradhan, A., Cui, H., Johnstone, K., Luk, A., Hammond, R., Brown, C. S., Walker, A. S., & Eyre, D. W. (2026) · medRxiv · doi:10.64898/2026.09.29.26363894
TOPRAK, H. B., Taşkın, G., & Yamanel, H. L. (2026) · Medicina · doi:10.3390/medicina62101913
CUIqing, Fang, A., 张海燕, Meng, Q., Zhou, S., Yueming, P., & Luo, W. (2026) · PLoS ONE · doi:10.1371/journal.pone.0359719
Zhang, L., & Xu, Y. (2026) · Pharmaceutics · doi:10.3390/pharmaceutics18101256 · Cited by 1
Liu, C., Wang, H., 王仁坤, et al. (2026) · Research Square · doi:10.21203/rs.3.rs-11092342/v1
Raghavendra, A., Peters, C. J., & Zirikly, A. (2026) · doi:10.2196/preprints.113394
Liu, B., Zheng, X., Xu, Z., et al. (2026) · Advances in Therapy · doi:10.1007/s12325-026-03796-w
Prevalence Shift and ICU Mortality Miscalibration Across Institutions
Aman Chandra, H., Shivhare, S., & Sahu, S. (2026) · International Conference on Emerging Techniques in Computational Intelligence (ICETCI) · doi:10.1109/icetci71772.2026.11710759
“Machine learning (ML) models for predicting in-hospital mortality in intensive care units have demonstrated strong discriminative performance when evaluated on their training institutions [1], [2].”
Huang, J.-L., Yang, C.-H., & Pai, T. (2026) · JMIR Medical Informatics · doi:10.2196/95929
Nguyen, T. L., Nguyen, T. L., Duong, H. T., et al. (2026) · American Heart Journal Plus Cardiology Research and Practice · doi:10.1016/j.ahjo.2026.100935
Cheng, Z., Lu, Z., Wang, S., He, M., Lv, Y., Duoji, Z., Jin, X., Fan, W., Han, P., & Zhang, Q. (2026) · Frontiers in Neurology · doi:10.3389/fneur.2026.1865384
Wang, X., Cheng, M., Ruan, F., Chen, C., & Wang, S. (2026) · Frontiers in Nutrition · doi:10.3389/fnut.2026.1903225
Explainability and Verifiability of Artificial Intelligence in ICU Mortality Prediction
Chen, Y., & Kovásznai, G. (2026) · IEEE Conference on Information Technology and Data Science (CITDS) · doi:10.1109/citds70571.2026.11706859
“2 [1].”
InfluentialG, K. T., Manasa, M., Kanavalli, P., Harini, S., Mehta.S, S., & Bharath, B. (2026) · International Conference on Soft Computing for Security Applications (ICSCSA) · doi:10.1109/icscsa69367.2026.11708211
Zheng, Y. (2026) · Research Square · doi:10.21203/rs.3.rs-10323299/v1
Li, S., Han, Y., Ding, F., Qiu, Z., Ma, X., Huang, H., Zhang, B., & Wang, H. (2026) · Frontiers in Neurology · doi:10.3389/fneur.2026.1967355
PMVGD: Progressive multi-view graph distillation for health event prediction
TIAN, Y., & Qiu, H. (2026) · Information Sciences · doi:10.1016/j.ins.2026.124266 · Cited by 1
Qin, G., & Zou, K. (2026) · Frontiers in Artificial Intelligence · doi:10.3389/frai.2026.1836581
Yang, S., Luo, J., Ma, L., Huang, D., Zhu, M., & Cai, L. (2026) · Frontiers in Endocrinology · doi:10.3389/fendo.2026.1959304
Ma, L., Yang, S., Liu, W., et al. (2026) · Science Progress · doi:10.1177/00368504261494947
Wu, G., Lv, Q., Ye, Y., et al. (2026) · International Journal of Medical Informatics · doi:10.1016/j.ijmedinf.2026.106759
ASAF-MedRec: Auxiliary-supervised semantic alignment and fusion for medication recommendation
Yin, X., Li, Q., Li, Y., Dong, Z., Wan, Y., & Ju, S. (2026) · Information Processing & Management · doi:10.1016/j.ipm.2026.105218
Cui, J., Lim, E. Y. P., & Lim, C. E. D. (2026) · Technology and Health Care · doi:10.1177/09287329261495038
Liu, S., Fu, S., Zhang, S., et al. (2026) · Journal of International Medical Research · doi:10.1177/03000605261494418
Hao, F., Huangfu, L., Li, W., Li, Y., Hui, R., Sun, C., Liu, M., Shi, L., Xu, S., Cheng, G., et al. (2026) · Frontiers in Nutrition · doi:10.3389/fnut.2026.1909009
Bootdachi, J., Wonggom, P., & Potisopha, W. (2026) · Applied System Innovation · doi:10.3390/asi9100210
Xue, D., Zhang, M., 張欣綠, et al. (2026) · iScience · doi:10.1016/j.isci.2026.117643
AlignCheck: a Semantic Open-Domain Metric for Factual Consistency Assessment
Aghaebrahimian, A. (2025) · arXiv · doi:10.48550/arxiv.2512.03634
“MIMIC-IV-Ext-BHC is extracted from MIMIC-IV-Note (Johnson et al., 2023), which is a raw collection of 331,794 de-identified discharge summaries from 145,915 patients admitted to the Beth Israel Deaconess Medical Center.”
Multimorbidity Measurement Strategies for Predicting Hospital Visits
Neves, B., Moreira, J. M., Gonçalves, S., Cerejo, J., Mota, I., Silva, N. A., Leite, F., & Silva, M. J. (2025) · doi:10.21203/rs.3.rs-6515465/v1
Subtype-Aware Registration of Longitudinal Electronic Health Records
Gai, X., Jiang, S., & Zhang, A. R. (2026) · Journal of the American Statistical Association · doi:10.1080/01621459.2026.2613464
Metadata
- Authors
- Johnson, A. E. W., Bulgarelli, L., Shen, L., Gayles, A., Shammout, A., Horng, S., Pollard, T. J., Hao, S., Moody, B., Gow, B., Lehman, L.-W. H., Celi, L. A., & Mark, R. G.
- Affiliations
- Hospital for Sick Children (CA)
- Massachusetts Institute of Technology (US)
- Beth Israel Deaconess Medical Center (US)
- Corresponding author
- Johnson, Alistair E. W.
- ORCID
- Venue
- Scientific Data
- Published
- 2023-01-03
- Volume
- 10
- Issue
- 1
- Pages
- 1-1
- ISSN
- 2052-4463 (ISSN-L)
- PMC
- PMC9810617
- OpenAlex
- W4313439128
- Semantic Scholar
- 5425de16356015c2f26d2a50684c6c46d6998f51
- Cited by
- 3,401
- References
- 25
- Citations by year
- 2026: 1421 · 2025: 1175 · 2024: 649 · 2023: 154
- Type
- data paper
- Language
- en
- Update notices
- Open access
- gold
- doi.org
- Licence
- cc-by
- creativecommons.org/licenses/by/4.0 (tdm)
- creativecommons.org/licenses/by/4.0 (vor)
- Locations
- Scientific Data (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- U.S. Department of Health & Human Services | National Institutes of Health (NIH-R01-EB017205)
- Topics
- Physical Sciences › Computer Science › Artificial Intelligence › Machine Learning in Healthcare
- Health Sciences › Health Professions › Health Information Management › Electronic Health Records Systems
- Health Sciences › Health Professions › Health Information Management › Medical Coding and Health Information
- Keywords
- MIMIC-IV, electronic health records, clinical research data, hospital patient data, open data access, Beth Israel Deaconess Medical Center
- MeSH terms
- Hospitals, Humans, Databases, Factual, Electronic Health Records
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
The claim verdicts this report counts are experimental: their accuracy is not yet measured.
A language model drew the claims from the paper on 2026-10-02, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-10-02 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Cited sources are checked with a language model’s help (gpt-6-sol).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.