A novel microfluidic 3D platform for culturing pancreatic ductal adenocarcinoma cells: comparison with in vitro cultures and in vivo xenografts
Open accessThe DOI matches its Crossref record; 43 of the 43 references it cites were found in a registry or an index.
Abstract
The integration of microfluidics and cell biology has reached a significant milestone with the development of “organ-on-chips”, smart technological platforms that, once applied to the study of human diseases, such as cancer, might ultimately contribute to design personalised treatments and hence improve health outcomes. This paper reports that the combination of microfluidics and dielectrophoresis (DEP) allows to culture different pancreatic ductal adenocarcinoma (PDAC) human cell lines into a cyclic olefin polymer (COP) chamber (HepaChip ® ), enriched by the extracellular matrix (ECM) protein collagen. We show that PDAC cells cultured into the HepaChip ® (1) are vital and grow, provided they properly attach to collagen; (2) show morphological appearance and growth characteristics closer to those of cells grown as spheroids than as classical 2 dimensional (2D) in vitro cultures. Finally, preliminary experiments show that PDAC cells respond to high doses of Cisplatin perfused through the chip. Overall, the present microfluidic platform could be exploited in the future for a personalised approach to PDAC.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures





Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“This platform enables the culture of PDAC spheroids under continuous flow conditions and accurately captures PDAC cell behavior, displaying growth characteristics closer to 3D spheroid cultures than traditional 2D cultures.”
From Microphysiological systems as models for immunologically ‘cold’ tumors (2024) · cites this paper as Beer et al., 2017
The cited source says what the claim attributes to it.
In the citing paper
“In a separate recent study, researchers pioneered the integration of microfluidics and dielectrophoresis to culture PDAC human cell lines in a cyclic olefin polymer chamber, creating a biomimetic platform named HepaChip (Beer et al., 2017).”
From Microphysiological systems as models for immunologically ‘cold’ tumors (2024) · cites this paper as Beer et al., 2017
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The third dimension bridges the gap between cell culture and live tissue
Pampaloni, F., Reynaud, E. G., & Stelzer, E. H. K. (2007) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm2236 · Cited by 2,817
Edmondson, R., Broglie, J. J., Adcock, A. F., & Yang, L. (2014) · ASSAY and Drug Development Technologies · doi:10.1089/adt.2014.573 · Cited by 2,515
Drug Resistance and the Solid Tumor Microenvironment
Tredan, O., Galmarini, C. M., Patel, K., & Tannock, I. F. (2007) · JNCI Journal of the National Cancer Institute · doi:10.1093/jnci/djm135 · Cited by 2,116
From 3D cell culture to organs-on-chips
Huh, D., Hamilton, G. A., & Ingber, D. E. (2011) · Trends in Cell Biology · doi:10.1016/j.tcb.2011.09.005 · Cited by 1,834
Multicellular tumor spheroids: An underestimated tool is catching up again
Hirschhaeuser, F., Menne, H., Dittfeld, C., West, J., Mueller-Klieser, W., & Kunz-Schughart, L. A. (2010) · Journal of Biotechnology · doi:10.1016/j.jbiotec.2010.01.012 · Cited by 1,674
Three-dimensional cell culture: the missing link in drug discovery
Breslin, S., & O’Driscoll, L. (2013) · Drug Discovery Today · doi:10.1016/j.drudis.2012.10.003 · Cited by 1,332
Organs-on-chips at the frontiers of drug discovery
Esch, E. W., Bahinski, A., & Huh, D. (2015) · Nature Reviews Drug Discovery · doi:10.1038/nrd4539 · Cited by 1,185
Regulation of the actin cytoskeleton in cancer cell migration and invasion
Yamaguchi, H., & Condeelis, J. (2007) · Biochimica et Biophysica Acta (BBA) - Molecular Cell Research · doi:10.1016/j.bbamcr.2006.07.001 · Cited by 1,144
Phenotype and Genotype of Pancreatic Cancer Cell Lines
Deer, E. L., González-Hernández, J., Coursen, J. D., Shea, J. E., Ngatia, J., Scaife, C. L., Firpo, M. A., & Mulvihill, S. J. (2010) · Pancreas · doi:10.1097/mpa.0b013e3181c15963 · Cited by 936
Heinemann, V., Quietzsch, D., Gieseler, F., Gonnermann, M., Schönekäs, H., Rost, A., Neuhaus, H., Haag, C., Clemens, M., Heinrich, B., et al. (2006) · Journal of Clinical Oncology · doi:10.1200/jco.2005.05.1490 · Cited by 683
Microengineered physiological biomimicry: Organs-on-Chips
Huh, D., Torisawa, Y.-S., Hamilton, G. A., Kim, H. J., & Ingber, D. E. (2012) · Lab on a Chip · doi:10.1039/c2lc40089h · Cited by 667
Pancreatic tumors show high levels of hypoxia
Koong, A. C., Mehta, V. K., Le, Q. T., Fisher, G. A., Terris, D. J., Brown, J. M., Bastidas, A. J., & Vierra, M. (2000) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(00)00803-8 · Cited by 650
Chiu, D. T., Jeon, N. L., Huang, S., Kane, R. S., Wargo, C. J., Choi, I. S., Ingber, D. E., & Whitesides, G. M. (2000) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.040562297 · Cited by 526
A Review of Three-Dimensional In Vitro Tissue Models for Drug Discovery and Transport Studies
Elliott, N. T., & Yuan, F. (2011) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.22257 · Cited by 449
Animal models in translational medicine: Validation and prediction
Denayer, T., Stöhr, T., & Roy, M. V. (2014) · European Journal of Molecular & Clinical Medicine · doi:10.1016/j.nhtm.2014.08.001 · Cited by 448
A microfluidic 3D hepatocyte chip for drug toxicity testing
Toh, Y.-C., Lim, T. C., Tai, D., Xiao, G., van Noort, D., & Yu, H. (2009) · Lab on a Chip · doi:10.1039/b900912d · Cited by 419
Ho, C.-T., Lin, R.-Z., Chang, W.-Y., Chang, H.-Y., & Liu, C.-H. (2006) · Lab on a Chip · doi:10.1039/b602036d · Cited by 283
Advanced Cell Culture Techniques for Cancer Drug Discovery
Lovitt, C., Shelper, T., & Avery, V. (2014) · Biology · doi:10.3390/biology3020345 · Cited by 282
A review of microfabrication and hydrogel engineering for micro-organs on chips
Verhulsel, M., Vignes, M., Descroix, S., Malaquin, L., Vignjevic, D. M., & Viovy, J.-L. (2014) · Biomaterials · doi:10.1016/j.biomaterials.2013.11.021 · Cited by 231
Microfluidics: A New Tool for Modeling Cancer–Immune Interactions
Boussommier-Calleja, A., Li, R., Chen, M. B., Wong, S. C., & Kamm, R. D. (2016) · Trends in Cancer · doi:10.1016/j.trecan.2015.12.003 · Cited by 224
Astashkina, A., & Grainger, D. W. (2014) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2014.02.008 · Cited by 195
Santini, M. (2000) · Critical Reviews in Oncology/Hematology · doi:10.1016/s1040-8428(00)00078-0 · Cited by 189
Mouse models of pancreatic cancer
Herreros-Villanueva, M. (2012) · World Journal of Gastroenterology · doi:10.3748/wjg.v18.i12.1286 · Cited by 164
Pillozzi, S., Masselli, M., Lorenzo, E. D., Accordi, B., Cilia, E., Crociani, O., Amedei, A., Veltroni, M., D’Amico, M., Basso, G., et al. (2010) · Blood · doi:10.1182/blood-2010-01-262691 · Cited by 148
Three-dimensional cancer models mimic cell-matrix interactions in the tumour microenvironment
Herrmann, D., Conway, J. R. W., Vennin, C., Magenau, A., Hughes, W. E., Morton, J. P., & Timpson, P. (2014) · Carcinogenesis · doi:10.1093/carcin/bgu108 · Cited by 144
Chen, W., Wong, C., Vosburgh, E., Levine, A. J., Foran, D. J., & Xu, E. Y. (2014) · Journal of Visualized Experiments · doi:10.3791/51639 · Cited by 132
Preclinical models of pancreatic ductal adenocarcinoma
Hwang, C., Boj, S. F., Clevers, H., & Tuveson, D. A. (2016) · The Journal of Pathology · doi:10.1002/path.4651 · Cited by 105
Comparative pharmacokinetics of cisplatin and three analogues in mice and humans.
van Hennik, M. B., van der Vijgh, W. J. F., Klein, I., Elferink, F., Vermorken, J. B., Winograd, B., & Pinedo, H. M. (1987) · PubMed · Cited by 94
Yates, C. C., Shepard, C. R., Papworth, G. D., Dash, A., Stolz, D. B., Tannenbaum, S. R., Griffith, L. G., & Wells, A. H. (2007) · Advances in cancer research · doi:10.1016/s0065-230x(06)97010-9 · Cited by 87
“Artificial micro organs”—a microfluidic device for dielectrophoretic assembly of liver sinusoids
Schütte, J., Hagmeyer, B., Holzner, F., Kubon, M., Werner, S., Freudigmann, C., Benz, K., Böttger, J., Gebhardt, R., Becker, H., et al. (2011) · Biomedical Microdevices · doi:10.1007/s10544-011-9517-7 · Cited by 87
Seo, B. R., DelNero, P., & Fischbach, C. (2014) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2013.11.011 · Cited by 74
Disease-on-a-chip: mimicry of tumor growth in mammary ducts
Vidi, P.-A., Maleki, T., Ochoa, M., Wang, L., Clark, S. M., Leary, J. F., & Lelièvre, S. A. (2014) · Lab Chip · doi:10.1039/c3lc50819f · Cited by 71
Drifka, C. R., Eliceiri, K. W., Weber, S. M., & Kao, W. J. (2013) · Lab on a Chip · doi:10.1039/c3lc50487e · Cited by 64
Modulating effect of the PI3-kinase inhibitor LY294002 on cisplatin in human pancreatic cancer cells
Fujiwara, M., Izuishi, K., Sano, T., Hossain, M. A., Kimura, S., Masaki, T., & Suzuki, Y. (2008) · Journal of Experimental & Clinical Cancer Research · doi:10.1186/1756-9966-27-76 · Cited by 63
Dickinson, L. E., Lütgebaucks, C., Lewis, D. M., & Gerecht, S. (2012) · Lab on a Chip · doi:10.1039/c2lc40819h · Cited by 53
Coleman, S. J., Watt, J., Arumugam, P., Solaini, L., Carapuca, E., Ghallab, M., Grose, R. P., & Kocher, H. M. (2014) · World Journal of Gastroenterology · doi:10.3748/wjg.v20.i26.8471 · Cited by 52
Towards plug and play filling of microfluidic devices by utilizing networks of capillary stop valves
Hagmeyer, B., Zechnall, F., & Stelzle, M. (2014) · Biomicrofluidics · doi:10.1063/1.4896063 · Cited by 38
A method for patterned in situ biofunctionalization in injection-molded microfluidic devices
Schütte, J., Freudigmann, C., Benz, K., Böttger, J., Gebhardt, R., & Stelzle, M. (2010) · Lab on a Chip · doi:10.1039/c005307d · Cited by 36
In vitromodels of pancreatic cancer for translational oncology research
Feldmann, G., Rauenzahn, S. L., & Maitra, A. (2009) · Expert Opinion on Drug Discovery · doi:10.1517/17460440902821657 · Cited by 33
Hwang, I. G., Jang, J.-S., Oh, S. Y., Lee, S., Kwon, H. C., Lee, G. W., Go, S., Kang, M. H., Cha, Y. J., & Kang, J. H. (2012) · Investigational New Drugs · doi:10.1007/s10637-012-9792-z · Cited by 15
Holzner, F., Hagmeyer, B., Schütte, J., Kubon, M., Angres, B., & Stelzle, M. (2011) · Electrophoresis · doi:10.1002/elps.201100026 · Cited by 8
[Development of three-dimensional breast cancer cell culture drug resistance model].
Xu, H., Liu, W., Zhang, X., Hou, L., Lu, Y.-J., Chen, P., Zhang, C., Feng, D., Kong, L., & Wang, X. (2016) · PubMed · Cited by 4
Zhang, Y., Qian, D., Pan, Y., Zhai, Y.-J., Zhou, X., Zhong, G., Zhu, Z., & Duan, J. (2015) · China Journal of Chinese Materia Medica · doi:10.4268/cjcmm20152325 · Cited by 3
Research works printed but not linked: 1
- Seo BR Delnero P Fischbach C In vitro models of tumor vessels and matrix: engineering approaches to investigate transport limitations and drug delivery in cancer Adv. Drug Deliv. Rev. 2014 69–70 205 16 10.1016/j.addr.2013.11.011 24309015 PMC4019703 · DOI · Paper page
Cited by
Campbell, S. B., Wu, Q., Yazbeck, J., Liu, C., Okhovatian, S., & Radisic, M. (2021) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.0c00640 · Cited by 297
Lazzari, G., Nicolas, V., Matsusaki, M., Akashi, M., Couvreur, P., & Mura, S. (2018) · Acta Biomaterialia · doi:10.1016/j.actbio.2018.08.008 · Cited by 271
Patient-derived pancreatic cancer-on-a-chip recapitulates the tumor microenvironment
Haque, M. R., Wessel, C. R., Leary, D. D., Wang, C., Bhushan, A., & Bishehsari, F. (2022) · Microsystems & Nanoengineering · doi:10.1038/s41378-022-00370-6 · Cited by 137
Mulholland, T., McAllister, M., Patek, S., Flint, D., Underwood, M., Sim, A., Edwards, J., & Zagnoni, M. (2018) · Scientific Reports · doi:10.1038/s41598-018-33055-0 · Cited by 132
Hydrogels as artificial matrices for cell seeding in microfluidic devices
Akther, F., Little, P., Li, Z., Nguyen, N.-T., & Ta, H. T. (2020) · RSC Advances · doi:10.1039/d0ra08566a · Cited by 127
Metadata
- Authors
- Beer, M., Kuppalu, N., Stefanini, M., Becker, H., Schulz, I., Manoli, S., Schuette, J., Schmees, C., Casazza, A., Stelzle, M., & Arcangeli, A.
- Affiliations
- University of Tübingen (DE)
- University of Florence (IT)
- Microfluidic ChipShop (Germany) (DE)
- Corresponding author
- Arcangeli, Annarosa
- Venue
- Scientific Reports
- Published
- 2017-04-25
- Volume
- 7
- Issue
- 1
- Pages
- 1325-1325
- ISSN
- 2045-2322 (ISSN-L)
- PMC
- PMC5430997
- OpenAlex
- W2608386102
- Cited by
- 75
- References
- 43
- Citations by year
- 2026: 5 · 2025: 4 · 2024: 9 · 2023: 4 · 2022: 10 · 2021: 15 · 2020: 11 · 2019: 8 · 2018: 9
- FWCI
- 3.44
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by
- creativecommons.org/licenses/by/4.0 (tdm)
- creativecommons.org/licenses/by/4.0 (vor)
- Locations
- Scientific Reports (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Florence Research (University of Florence) (submittedVersion, other-oa)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- Bundesministerium für Bildung und Forschung
- Associazione Italiana per la Ricerca sul Cancro (IG15627, 15627)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › 3D Printing in Biomedical Research
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Bio-sensing Technologies
- Keywords
- pancreatic ductal adenocarcinoma, organ-on-a-chip, dielectrophoresis, cyclic olefin polymer, collagen extracellular matrix, 3D cell culture, spheroids, cisplatin response, precision oncology
- MeSH terms
- Antineoplastic Agents, Cell Survival, Cisplatin, Collagen, Cycloparaffins, Humans, Pancreatic Neoplasms, Cell Culture Techniques, Carcinoma, Pancreatic Ductal, Cell Line, Tumor, Microfluidic Analytical Techniques, Lab-On-A-Chip Devices, In Vitro Techniques
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.