The DOI matches its Crossref record.
Beyond the Debye length in high ionic strength solution: direct protein detection with field-effect transistors (FETs) in human serum
Open accessAbstract
In this study, a new type of field-effect transistor (FET)-based biosensor is demonstrated to be able to overcome the problem of severe charge-screening effect caused by high ionic strength in solution and detect proteins in physiological environment. Antibody or aptamer-immobilized AlGaN/GaN high electron mobility transistors (HEMTs) are used to directly detect proteins, including HIV-1 RT, CEA, NT-proBNP and CRP, in 1X PBS (with 1%BSA) or human sera. The samples do not need any dilution or washing process to reduce the ionic strength. The sensor shows high sensitivity and the detection takes only 5 minutes. The designs of the sensor, the methodology of the measurement, and the working mechanism of the sensor are discussed and investigated. A theoretical model is proposed based on the finding of the experiments. This sensor is promising for point-of-care, home healthcare, and mobile diagnostic device.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 34
- Chen, K.-I., Li, B.-R. & Chen, Y.-T. Silicon nanowire field-effect transistor-based biosensors for biomedical diagnosis and cellular recording investigation. Nano Today 6, 131–154 (2011). · DOI · Paper page
- Chen, C.-P. et al. Ultrasensitive in Situ Label-Free DNA Detection Using a GaN Nanowire-Based Extended-Gate Field-Effect-Transistor Sensor. Analytical Chemistry 83, 1938–1943 (2011). · DOI
- Allen, B. L., Kichambare, P. D. & Star, A. Carbon Nanotube Field-Effect-Transistor-Based Biosensors. Advanced Materials 19, 1439–1451 (2007). · DOI · Paper page
- Inaba, A., Yoo, K., Takei, Y., Matsumoto, K. & Shimoyama, I. Ammonia gas sensing using a graphene field–effect transistor gated by ionic liquid. Sensors and Actuators B: Chemical 195, 15–21 (2014). · DOI
- Lin, S.-P. et al. A reversible surface functionalized nanowire transistor to study protein–protein interactions. Nano Today 4, 235–243 (2009). · DOI
- Zheng, G., Patolsky, F., Cui, Y., Wang, W. U. & Lieber, C. M. Multiplexed electrical detection of cancer markers with nanowire sensor arrays. Nat Biotech 23, 1294–1301 (2005). · DOI · Paper page
- Stern, E. et al. Label-free biomarker detection from whole blood. Nat Nano 5, 138–142 (2010). · DOI · Paper page
- Kulkarni, G. S. & Zhong, Z. Detection beyond the Debye Screening Length in a High-Frequency Nanoelectronic Biosensor. Nano Letters 12, 719–723 (2012). · DOI · Paper page
- LabordeC et al. Real-time imaging of microparticles and living cells with CMOS nanocapacitor arrays. Nat Nano 10, 791–795 (2015). · DOI · Paper page
- Woo, J.-M. et al. Modulation of molecular hybridization and charge screening in a carbon nanotube network channel using the electrical pulse method. Lab on a Chip 13, 3755–3763 (2013). · DOI
- Munje, R. D., Muthukumar, S., Panneer Selvam, A. & Prasad, S. Flexible nanoporous tunable electrical double layer biosensors for sweat diagnostics. Scientific Reports 5, 14586 (2015). · DOI · Paper page
- Fujimoto, T. & Awaga, K. Electric-double-layer field-effect transistors with ionic liquids. Physical Chemistry Chemical Physics 15, 8983–9006 (2013). · DOI · Paper page
- Du, H., Lin, X., Xu, Z. & Chu, D. Electric double-layer transistors: a review of recent progress. Journal of Materials Science 50, 5641–5673 (2015). · DOI · Paper page
- Kamalakar, M. V., Madhushankar, B. N., Dankert, A. & Dash, S. P. Effect of high-k dielectric and ionic liquid gate on nanolayer black-phosphorus field effect transistors. Applied Physics Letters 107, 113103 (2015). · doi:10.1063/1.4930236
- Kim, S. H. et al. Electrolyte-Gated Transistors for Organic and Printed Electronics. Advanced Materials 25, 1822–1846 (2013). · DOI · Paper page
- Yuan, H. et al. Electrostatic and Electrochemical Nature of Liquid-Gated Electric-Double-Layer Transistors Based on Oxide Semiconductors. Journal of the American Chemical Society 132, 18402–18407 (2010). · DOI · Paper page
- Liu, N. et al. Enhancing the pH sensitivity by laterally synergic modulation in dual-gate electric-double-layer transistors. Applied Physics Letters 106, 073507 (2015). · DOI
- Ye, P. D. et al. GaN metal-oxide-semiconductor high-electron-mobility-transistor with atomic layer deposited Al2O3 as gate dielectric. Applied Physics Letters 86, 063501 (2005). · doi:10.1063/1.1861122
- Gupta, S. et al. Detection of clinically relevant levels of protein analyte under physiologic buffer using planar field effect transistors. Biosensors and Bioelectronics 24, 505–511 (2008). · DOI
- Schneider, D. J., Feigon, J., Hostomsky, Z. & Gold, L. High-affinity ssDNA inhibitors of the reverse transcriptase of type 1 human immunodeficiency virus. Biochemistry 34, 9599–9610 (1995). · DOI · Paper page
- Karyakin, A. A., Presnova, G. V., Rubtsova, M. Y. & Egorov, A. M. Oriented Immobilization of Antibodies onto the Gold Surfaces via Their Native Thiol Groups. Analytical Chemistry 72, 3805–3811 (2000). · DOI · Paper page
- Huang, C.-J., Lin, H.-I., Shiesh, S.-C. & Lee, G.-B. Integrated microfluidic system for rapid screening of CRP aptamers utilizing systematic evolution of ligands by exponential enrichment (SELEX). Biosensors and Bioelectronics 25, 1761–1766 (2010). · DOI
- Weng, C.-H., Huang, C.-J. & Lee, G.-B. Screening of Aptamers on Microfluidic Systems for Clinical Applications. Sensors 12, 9514 (2012). · DOI
- Shrivastava, A. K., Singh, H. V., Raizada, A. & Singh, S. K. C-reactive protein, inflammation and coronary heart disease. The Egyptian Heart Journal 67, 89–97 (2015). · DOI · Paper page
- Ohshima, H. Theory of Colloid and Interfacial Electric Phenomena, 1–38 (Elsevier, 2006).
- Holmes, D. L. & Stellwagen, N. C. The electric field dependence of DNA mobilities in agarose gels: A reinvestigation. Electrophoresis 11, 5–15 (1990). · doi:10.1002/elps.1150110103
- Li, B. et al. Influence of electric field intensity, ionic strength, and migration distance on the mobility and diffusion in DNA surface electrophoresis. Electrophoresis 27, 1312–1321 (2006). · doi:10.1002/elps.200500444
- Jameson, E. & Alvarez-Tostado, C. A Study of Blood Serum Proteins by Electrophoresis. The Journal of Physical Chemistry 43, 1165–1172 (1939). · doi:10.1021/j150396a007
- Chia-Chang, T. et al. Surface potential variations on a silicon nanowire transistor in biomolecular modification and detection. Nanotechnology 22, 135503 (2011). · DOI
- Davis, A. J. et al. Human Immunodeficiency Virus type-1 reverse transcriptase exists as post-translationally modified forms in virions and cells. Retrovirology 5, 1–12 (2008). · doi:10.1186/1742-4690-5-115
- Casey, B. J. & Kofinas, P. Selective binding of carcinoembryonic antigen using imprinted polymeric hydrogels. Journal of Biomedical Materials Research Part A 87A, 359–363 (2008). · doi:10.1002/jbm.a.31757
- Tsujimoto, M., Inoue, K. & Nojima, S. Purification and Characterization of Human Serum C-Reactive Protein. Journal of Biochemistry 94, 1367–1373 (1983). · doi:10.1093/oxfordjournals.jbchem.a134483
- Long, H., Kudlay, A. & Schatz, G. C. Molecular Dynamics Studies of Ion Distributions for DNA Duplexes and DNA Clusters: Salt Effects and Connection to DNA Melting. The Journal of Physical Chemistry B 110, 2918–2926 (2006). · doi:10.1021/jp0556815
- Hsu, C.-P., Huang, Y.-F. & Wang, Y.-L. Investigation of the Non-Faradaic Current of DNA-Immobilized Microelectrodes in Concentrated Salt Environment for Biosensors. ECS Journal of Solid State Science and Technology 5, Q149–Q154 (2016). · doi:10.1149/2.0141606jss
Cited by
Bolotsky, A., Butler, D., Dong, C., Gerace, K., Glavin, N. R., Muratore, C., Robinson, J. A., & Ebrahimi, A. (2019) · ACS Nano · doi:10.1021/acsnano.9b03632 · Cited by 381
Recent developments in biosensors for healthcare and biomedical applications: A review
Mohankumar, P., Ajayan, J., Mohanraj, T., & Yasodharan, R. (2021) · Measurement · doi:10.1016/j.measurement.2020.108293 · Cited by 266
Extended gate field-effect-transistor for sensing cortisol stress hormone
Sheibani, S., Capua, L., Kamaei, S., Akbari, S. S. A., Zhang, J., Guerin, H., & Ionescu, A. M. (2021) · Communications Materials · doi:10.1038/s43246-020-00114-x · Cited by 158
Lin, S.-P., Lee, W.-J., Sun, M.-C., Yang, Y.-H., Vinzons, L. U., Lin, Y.-M., & Wei, Y.-T. (2023) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.3c12766 · Cited by 11
Metadata
- Authors
- Chu, C.-H., Sarangadharan, I., Regmi, A., Chen, Y.-W., Hsu, C.-P., Chang, W.-H., Lee, G.-Y., Chyi, J.-I., Chen, C.-C., Shiesh, S.-C., Lee, G.-B., & Wang, Y.-L.
- Venue
- Scientific Reports
- Published
- 2017-07-12
- Volume
- 7
- Issue
- 1
- Pages
- 5256-5256
- ISSN
- 2045-2322 (ISSN-L)
- OpenAlex
- W2731814899
- Cited by
- 245
- References
- 0
- FWCI
- 14.27
- Type
- journal article
- Language
- en
- Open access
- gold
- Licence
- creativecommons.org/licenses/by/4.0 (tdm)
- creativecommons.org/licenses/by/4.0 (vor)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Beyond the Debye length in high ionic strength solution: direct protein detection with field-effect transistors (FETs) in human serum. https://app.cochat.ai/papers/10.1038/s41598-017-05426-6
- The paper
- Chu, C.-H., Sarangadharan, I., Regmi, A., Chen, Y.-W., Hsu, C.-P., Chang, W.-H., Lee, G.-Y., Chyi, J.-I., Chen, C.-C., Shiesh, S.-C., Lee, G.-B., & Wang, Y.-L. (2017). Beyond the Debye length in high ionic strength solution: direct protein detection with field-effect transistors (FETs) in human serum. Scientific Reports. https://doi.org/10.1038/s41598-017-05426-6
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.