Ultrasound localization microscopy to image and assess microvasculature in a rat kidney
Open accessThe DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Abstract
The recent development of ultrasound localization microscopy, where individual microbubbles (contrast agents) are detected and tracked within the vasculature, provides new opportunities for imaging the vasculature of entire organs with a spatial resolution below the diffraction limit. In stationary tissue, recent studies have demonstrated a theoretical resolution on the order of microns. In this work, single microbubbles were localized in vivo in a rat kidney using a dedicated high frame rate imaging sequence. Organ motion was tracked by assuming rigid motion (translation and rotation) and appropriate correction was applied. In contrast to previous work, coherence-based non-linear phase inversion processing was used to reject tissue echoes while maintaining echoes from very slowly moving microbubbles. Blood velocity in the small vessels was estimated by tracking microbubbles, demonstrating the potential of this technique to improve vascular characterization. Previous optical studies of microbubbles in vessels of approximately 20 microns have shown that expansion is constrained, suggesting that microbubble echoes would be difficult to detect in such regions. We therefore utilized the echoes from individual MBs as microscopic sensors of slow flow associated with such vessels and demonstrate that highly correlated, wideband echoes are detected from individual microbubbles in vessels with flow rates below 2 mm/s.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Imaging Intracellular Fluorescent Proteins at Nanometer Resolution
Betzig, E., Patterson, G. H., Sougrat, R., Lindwasser, O. W., Olenych, S., Bonifacino, J. S., Davidson, M. W., Lippincott-Schwartz, J., & Hess, H. F. (2006) · Science · doi:10.1126/science.1127344 · Cited by 8,772
Sub-diffraction-limit imaging by stochastic optical reconstruction microscopy (STORM)
Rust, M. J., Bates, M., & Zhuang, X. (2006) · Nature Methods · doi:10.1038/nmeth929 · Cited by 8,078
Wei, K., Jayaweera, A. R., Firoozan, S., Linka, A., Skyba, D. M., & Kaul, S. (1998) · Circulation · doi:10.1161/01.cir.97.5.473 · Cited by 1,616
Ultrafast ultrasound localization microscopy for deep super-resolution vascular imaging
Errico, C., Pierre, J., Pezet, S., Desailly, Y., Lenkei, Z., Couture, O., & Tanter, M. (2015) · Nature · doi:10.1038/nature16066 · Cited by 1,349
Ultrafast imaging in biomedical ultrasound
Tanter, M., & Fink, M. (2014) · IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control · doi:10.1109/tuffc.2014.2882 · Cited by 1,151
Demene, C., Deffieux, T., Pernot, M., Osmanski, B.-F., Biran, V., Gennisson, J.-L., Sieu, L.-A., Bergel, A., Franqui, S., Correas, J.-M., et al. (2015) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2015.2428634 · Cited by 983
Ultrafast compound doppler imaging: providing full blood flow characterization
Bercoff, J., Montaldo, G., Loupas, T., Savery, D., Mézière, F., Fink, M., & Tanter, M. (2011) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2011.1780 · Cited by 510
In Vivo Acoustic Super-Resolution and Super-Resolved Velocity Mapping Using Microbubbles
Christensen-Jeffries, K. M., Browning, R. J., Tang, M., Dunsby, C. W., & Eckersley, R. J. (2014) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2014.2359650 · Cited by 489
A fundamental limit on delay estimation using partially correlated speckle signals
Walker, W. F., & Trahey, G. E. (1995) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.365243 · Cited by 479
Imaging Tumor Angiogenesis With Contrast Ultrasound and Microbubbles Targeted to α v β 3
Ellegala, D. B., Leong-Poi, H., Carpenter, J. E., Klibanov, A. L., Kaul, S., Shaffrey, M. E., Sklenar, J., & Lindner, J. R. (2003) · Circulation · doi:10.1161/01.cir.0000080326.15367.0c · Cited by 454
Lin, F., Shelton, S. E., Espíndola, D., Rojas, J. D., Pinton, G., & Dayton, P. A. (2017) · Theranostics · doi:10.7150/thno.16899 · Cited by 260
Urinary concentrating ability: insights from comparative anatomy
Bankir, L., & de Rouffignac, C. (1985) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.1985.249.6.r643 · Cited by 227
Direct observations of ultrasound microbubble contrast agent interaction with the microvessel wall
Caskey, C. F., Stieger, S. M., Qin, S., Dayton, P. A., & Ferrara, K. W. (2007) · The Journal of the Acoustical Society of America · doi:10.1121/1.2747204 · Cited by 226
Self-citationUltrasound contrast plane wave imaging
Couture, O., Fink, M., & Tanter, M. (2012) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2012.2508 · Cited by 190
Subwavelength motion-correction for ultrafast ultrasound localization microscopy
Hingot, V., Errico, C., Tanter, M., & Couture, O. (2017) · Ultrasonics · doi:10.1016/j.ultras.2017.01.008 · Cited by 135
Fast Vascular Ultrasound Imaging With Enhanced Spatial Resolution and Background Rejection
Bar‐Zion, A., Tremblay‐Darveau, C., Solomon, O., Adam, D., & Eldar, Y. C. (2016) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2016.2600372 · Cited by 123
Lindner, J. R., Womack, L., Barrett, E. J., Weltman, J. Y., Price, W., Harthun, N. L., Kaul, S., & Patrie, J. T. (2008) · JACC. Cardiovascular imaging · doi:10.1016/j.jcmg.2008.04.001 · Cited by 120 · cited 1×
“θ θ θ θ = + − − + − F u v F u v u u v v ( , ) ( cos sin , sin cos ) (3) m ref 0 0 0 0 0 0”
A new imaging strategy using wideband transient response of ultrasound contrast agents
Kruse, D. E., & Ferrara, K. W. (2005) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2005.1509790 · Cited by 109
Self-citationContrast enhanced ultrasound by real-time spatiotemporal filtering of ultrafast images
Desailly, Y., Tissier, A.-M., Corréas, J.-M., Wintzenrieth, F., Tanter, M., & Couture, O. (2016) · Physics in Medicine and Biology · doi:10.1088/1361-6560/62/1/31 · Cited by 81
Papadacci, C., Tanter, M., Pernot, M., & Fink, M. (2014) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2014.2994 · Cited by 65
Ultrasound molecular imaging of tumor angiogenesis with a neuropilin-1-targeted microbubble
Zhang, H., Tam, S., Ingham, E. S., Mahakian, L. M., Lai, C.-Y., Tumbale, S. K., Teesalu, T., Hubbard, N. E., Borowsky, A. D., & Ferrara, K. W. (2015) · Biomaterials · doi:10.1016/j.biomaterials.2015.03.043 · Cited by 59
Self-citationBroillet, A., Hantson, J., Rüegg, C., Messager, T., & Schneider, M. (2005) · Academic Radiology · doi:10.1016/j.acra.2005.02.021 · Cited by 29 · cited 1×
“∑ ∑ γ = − γ { } ( ) F F arg min (4) sol u v m ref 2”
Pollard, R. E., Dayton, P. A., Watson, K. D., Hu, X., Guracar, I., & Ferrara, K. W. (2009) · Urology · doi:10.1016/j.urology.2009.01.086 · Cited by 24
Self-citation
Cited by
Super-resolution Ultrasound Imaging
Christensen-Jeffries, K., Couture, O., Dayton, P. A., Eldar, Y. C., Hynynen, K., Kiessling, F., O'Reilly, M., Pinton, G. F., Schmitz, G., Tang, M.-X., et al. (2020) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2019.11.013 · Cited by 558
Ultrasound Localization Microscopy and Super-Resolution: A State of the Art
Couture, O., Hingot, V., Heiles, B., Muleki-Seya, P., & Tanter, M. (2018) · IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control · doi:10.1109/tuffc.2018.2850811 · Cited by 423
Opacic, T., Dencks, S., Theek, B., Piepenbrock, M., Ackermann, D., Rix, A., Lammers, T., Stickeler, E., Delorme, S., Schmitz, G., et al. (2018) · Nature Communications · doi:10.1038/s41467-018-03973-8 · Cited by 295
Opening doors with ultrasound and microbubbles: Beating biological barriers to promote drug delivery
Deprez, J., Lajoinie, G., Engelen, Y., De Smedt, S. C., & Lentacker, I. (2021) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2021.02.015 · Cited by 207
Hingot, V., Errico, C., Heiles, B., Rahal, L., Tanter, M., & Couture, O. (2019) · Scientific Reports · doi:10.1038/s41598-018-38349-x · Cited by 194
Metadata
- Authors
- Foiret, J., Zhang, H., Ilovitsh, T., Mahakian, L., Tam, S., & Ferrara, K. W.
- Venue
- Scientific Reports
- Published
- 2017-10-20
- Volume
- 7
- Issue
- 1
- Pages
- 13662-13662
- ISSN
- 2045-2322 (ISSN-L)
- OpenAlex
- W2765113479
- Cited by
- 169
- References
- 23
- FWCI
- 6.17
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.