Extracellular Total Electrolyte Concentration Imaging for Electrical Brain Stimulation (EBS)
Open accessThe DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Abstract
Techniques for electrical brain stimulation (EBS), in which weak electrical stimulation is applied to the brain, have been extensively studied in various therapeutic brain functional applications. The extracellular fluid in the brain is a complex electrolyte that is composed of different types of ions, such as sodium (Na+), potassium (K+), and calcium (Ca+). Abnormal levels of electrolytes can cause a variety of pathological disorders. In this paper, we present a novel technique to visualize the total electrolyte concentration in the extracellular compartment of biological tissues. The electrical conductivity of biological tissues can be expressed as a product of the concentration and the mobility of the ions. Magnetic resonance electrical impedance tomography (MREIT) investigates the electrical properties in a region of interest (ROI) at low frequencies (below 1 kHz) by injecting currents into the brain region. Combining with diffusion tensor MRI (DT-MRI), we analyze the relation between the concentration of ions and the electrical properties extracted from the magnetic flux density measurements using the MREIT technique. By measuring the magnetic flux density induced by EBS, we propose a fast non-iterative technique to visualize the total extracellular electrolyte concentration (EEC), which is a fundamental component of the conductivity. The proposed technique directly recovers the total EEC distribution associated with the water transport mobility tensor.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Scale-space and edge detection using anisotropic diffusion
Perona, P., & Malik, J. (1990) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.56205 · Cited by 12,119
Generalized Cross-Validation as a Method for Choosing a Good Ridge Parameter
Golub, G. H., Heath, M., & Wahba, G. (1979) · Technometrics · doi:10.1080/00401706.1979.10489751 · Cited by 3,934
Analysis of Discrete Ill-Posed Problems by Means of the L-Curve
Hansen, P. C. (1992) · SIAM Review · doi:10.1137/1034115 · Cited by 3,903
Looking into the functional architecture of the brain with diffusion MRI.
Le Bihan, D. (2003) · Nature Reviews Neuroscience · doi:10.1038/nrn1119 · Cited by 1,571 · cited 1×
“We minimized the GCV function GCV(λ) in (19) to determine an optimal regularization parameter at each voxel.”
Wang, E.-S., Yao, H.-B., Chen, Y.-H., Wang, G., Gao, W.-W., Sun, Y.-R., Guo, J.-G., Hu, J.-W., Jiang, C.-C., & Hu, J. (2013) · Cellular Physiology and Biochemistry · doi:10.1159/000350082 · Cited by 1,176
Lugol, P., Guyot, J., & Job, P. (1913) · Journal de Physique Théorique et Appliquée · doi:10.1051/jphystap:01913003007401 · Cited by 945
Translational principles of deep brain stimulation
Kringelbach, M. L., Jenkinson, N., Owen, S. L. F., & Aziz, T. Z. (2007) · Nature Reviews Neuroscience · doi:10.1038/nrn2196 · Cited by 853 · cited 1×
“B y y J x x J d r r r r r r ( ) 4 ( ) ( ) ( ) ( ) (6) z x y 0 3 ∫ μ π = − ′ ′ − − ′ ′ | − ′| ′.”
Horvath, J. C., Forte, J. D., & Carter, O. (2015) · Brain Stimulation · doi:10.1016/j.brs.2015.01.400 · Cited by 609 · cited 1×
“ = + × × × − B B sd r 2 9 1 2 (3) z i z i B n z”
Niendorf, T., Dijkhuizen, R. M., Norris, D. G., van Lookeren Campagne, M., & Nicolay, K. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910360607 · Cited by 570 · cited 2×
“Since the structure of the generated phantoms is simple, we directly recovered the total ion concentration by solving the matrix system (17).”
Balas, B. J., Nelson, C. A., Westerlund, A., Vogel-Farley, V., Riggins, T., & Kuefner, D. (2010) · Frontiers in Human Neuroscience · doi:10.3389/neuro.09.001.2010 · Cited by 542
The electrical conductivity of human cerebrospinal fluid at body temperature
Baumann, S. B., Wozny, D. R., Kelly, S. K., & Meno, F. M. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.554770 · Cited by 494
Utz, K. S., Dimova, V., Oppenländer, K., & Kerkhoff, G. (2010) · Neuropsychologia · doi:10.1016/j.neuropsychologia.2010.06.002 · Cited by 482
Conductivity tensor mapping of the human brain using diffusion tensor MRI
Tuch, D. S., Wedeen, V. J., Dale, A. M., George, J. S., & Belliveau, J. W. (2001) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.171473898 · Cited by 432
Electrical Stimulation of Human Fusiform Face-Selective Regions Distorts Face Perception
Parvizi, J., Jacques, C., Foster, B. L., Withoft, N., Rangarajan, V., Weiner, K. S., & Grill-Spector, K. (2012) · The Journal of Neuroscience · doi:10.1523/jneurosci.2609-12.2012 · Cited by 352 · cited 1×
“5(c,d,h,i)) for phantom-1 (2), respectively.”
Biomedical applications of sodium MRI in vivo
Madelin, G., & Regatte, R. R. (2013) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.24168 · Cited by 261
Sensitivity of magnetic-resonance current-density imaging
Scott, G. C., Joy, M. L. G., Armstrong, R. L., & Henkelman, R. M. (1992) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(92)90310-4 · Cited by 248
High b‐value q‐space analyzed diffusion‐weighted MRI: Application to multiple sclerosis
Assaf, Y., Ben‐Bashat, D., Chapman, J., Peled, S., Biton, I. E., Kafri, M., Segev, Y., Hendler, T., Korczyn, A. D., Graif, M., et al. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10040 · Cited by 234
Winston, G. P., Micallef, C., Symms, M. R., Alexander, D. C., Duncan, J. S., & Zhang, H. (2014) · Epilepsy Research · doi:10.1016/j.eplepsyres.2013.11.004 · Cited by 137
Madelin, G., Kline, R., Walvick, R. P., & Regatte, R. R. (2014) · Scientific Reports · doi:10.1038/srep04763 · Cited by 135
Cranial Electrotherapy Stimulation for Treatment of Anxiety, Depression, and Insomnia
Kirsch, D. L., & Nichols, F. H. (2013) · Psychiatric Clinics of North America · doi:10.1016/j.psc.2013.01.006 · Cited by 133
Brain intra- and extracellular sodium concentration in multiple sclerosis: a 7 T MRI study
Petracca, M., Vancea, R., Fleysher, L., Jonkman, L. E., Oesingmann, N., & Inglese, M. (2016) · Brain · doi:10.1093/brain/awv386 · Cited by 113
Conductivity Mapping of Biological Tissue Using Diffusion MRI
Tuch, D. S., Wedeen, V. J., Dale, A. M., George, J., & Belliveau, J. W. (1999) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1999.tb07965.x · Cited by 93
HISTORY OF BIOIMPEDANCE AND BIOELECTRICITY
Grimnes, S., & Martinsen, Ø. G. (2008) · Elsevier eBooks · doi:10.1016/b978-0-12-374004-5.00010-6 · Cited by 88
Gao, N., Zhu, S. A., & He, B. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/12/005 · Cited by 81
Neuropsychologic effects of neuromodulation techniques for treatment-resistant depression: A review
Moreines, J. L., McClintock, S. M., & Holtzheimer, P. E. (2011) · Brain Stimulation · doi:10.1016/j.brs.2010.01.005 · Cited by 78
Selimbeyoglu, A. (2010) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2010.00046 · Cited by 68
White matter compartment models for in vivo diffusion MRI at 300 mT/m
Ferizi, U., Schneider, T., Witzel, T., Wald, L. L., Zhang, H., Wheeler-Kingshott, C. A. M., & Alexander, D. C. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2015.06.027 · Cited by 57
Integrated analysis of diffusion and relaxation of water in blood
Li, J. G., Stanisz, G. J., & Henkelman, R. M. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910400112 · Cited by 49
Mapping tissue sodium concentration in the human brain: A comparison of MR sequences at 9.4 Tesla
Romanzetti, S., Mirkes, C., Fiege, D. P., Celik, A., Felder, J., & Shah, N. J. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2014.03.079 · Cited by 43
Cited by
Parada Venegas, D., De la Fuente, M. K., Landskron, G., González, M. J., Quera, R., Dijkstra, G., Harmsen, H. J. M., Faber, K. N., & Hermoso, M. A. (2019) · Frontiers in Immunology · doi:10.3389/fimmu.2019.00277 · Cited by 3,820
Nguyen, P. H., Ramamoorthy, A., Sahoo, B. R., Zheng, J., Faller, P., Straub, J. E., Dominguez, L., Shea, J.-E., Dokholyan, N. V., De Simone, A., et al. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.0c01122 · Cited by 678
Lee, Y., Song, W. J., & Sun, J.-Y. (2020) · Materials Today Physics · doi:10.1016/j.mtphys.2020.100258 · Cited by 507
Zero-order drug delivery: State of the art and future prospects
Laracuente, M.-L., Yu, M. H., & McHugh, K. J. (2020) · Journal of Controlled Release · doi:10.1016/j.jconrel.2020.09.020 · Cited by 384
Askari, M., Afzali Naniz, M., Kouhi, M., Saberi, A., Zolfagharian, A., & Bodaghi, M. (2021) · Biomaterials Science · doi:10.1039/d0bm00973c · Cited by 369
Metadata
- Authors
- Sajib, S. Z. K., Lee, M. B., Kim, H. J., Woo, E. J., & Kwon, O. I.
- Venue
- Scientific Reports
- Published
- 2018-01-10
- Volume
- 8
- Issue
- 1
- Pages
- 290-290
- ISSN
- 2045-2322 (ISSN-L)
- OpenAlex
- W2782519866
- Cited by
- 491
- References
- 29
- FWCI
- 45.72
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.