Noncontact and Nonintrusive Microwave-Microfluidic Flow Sensor for Energy and Biomedical Engineering
Open accessThe DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Abstract
A novel flow sensor is presented to measure the flow rate within microchannels in a real-time, noncontact and nonintrusive manner. The microfluidic device is made of a fluidic microchannel sealed with a thin polymer layer interfacing the fluidics and microwave electronics. Deformation of the thin circular membrane alters the permittivity and conductivity over the sensitive zone of the microwave resonator device and enables high-resolution detection of flow rate in microfluidic channels using non-contact microwave as a standalone system. The flow sensor has the linear response in the range of 0–150 µl/min for the optimal sensor performance. The highest sensitivity is detected to be 0.5 µl/min for the membrane with the diameter of 3 mm and the thickness of 100 µm. The sensor is reproducible with the error of 0.1% for the flow rate of 10 µl/min. Furthermore, the sensor functioned very stable for 20 hrs performance within the cell culture incubator in 37 °C and 5% CO 2 environment for detecting the flow rate of the culture medium. This sensor does not need any contact with the liquid and is highly compatible with several applications in energy and biomedical engineering, and particularly for microfluidic-based lab-on-chips, micro-bioreactors and organ-on-chips platforms.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Engineering Flows in Small Devices: Microfluidics Toward a Lab-on-a-Chip
Stone, H. A., Stroock, A. D., & Ajdari, A. (2004) · Annual Review of Fluid Mechanics · doi:10.1146/annurev.fluid.36.050802.122124 · Cited by 3,666
Organs-on-chips at the frontiers of drug discovery
Esch, E. W., Bahinski, A., & Huh, D. (2015) · Nature Reviews Drug Discovery · doi:10.1038/nrd4539 · Cited by 1,185
Zhang, Y. S., Aleman, J., Shin, S. R., Kilic, T., Kim, D., Mousavi Shaegh, S. A., Massa, S., Riahi, R., Chae, S., Hu, N., et al. (2017) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1612906114 · Cited by 833
Self-citationZhao, X., Liu, S., Yildirimer, L., Zhao, H., Ding, R., Wang, H., Cui, W., & Weitz, D. (2016) · Advanced Functional Materials · doi:10.1002/adfm.201504943 · Cited by 426
Active droplet generation in microfluidics
Chong, Z. Z., Tan, S. H., Gañán-Calvo, A. M., Tor, S. B., Loh, N. H., & Nguyen, N.-T. (2016) · Lab on a Chip · doi:10.1039/c5lc01012h · Cited by 297
Microfluidic‐integrated biosensors: Prospects for point‐of‐care diagnostics
Kumar, S., Kumar, S., Ali, M. A., Anand, P., Agrawal, V. V., John, R., Maji, S., & Malhotra, B. D. (2013) · Biotechnology Journal · doi:10.1002/biot.201200386 · Cited by 199
Chen, Y.-A., King, A. D., Shih, H.-C., Peng, C.-C., Wu, C.-Y., Liao, W.-H., & Tung, Y.-C. (2011) · Lab on a Chip · doi:10.1039/c1lc20325h · Cited by 185
Mousavi Shaegh, S. A., De Ferrari, F., Zhang, Y. S., Nabavinia, M., Binth Mohammad, N., Ryan, J., Pourmand, A., Laukaitis, E., Banan Sadeghian, R., Nadhman, A., et al. (2016) · Biomicrofluidics · doi:10.1063/1.4955155 · Cited by 160
Label-free quantitative DNA detection using the liquid core optical ring resonator
Suter, J. D., White, I. M., Zhu, H., Shi, H., Caldwell, C. W., & Fan, X. (2007) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2007.10.005 · Cited by 156
Shao, J., Wu, L., Wu, J., Zheng, Y., Zhao, H., Jin, Q., & Zhao, J. (2009) · Lab on a Chip · doi:10.1039/b909312e · Cited by 152
PDMS nanocomposites for heat transfer enhancement in microfluidic platforms
Yi, P., Awang, R. A., Rowe, W. S. T., Kalantar‐Zadeh, K., & Khoshmanesh, K. (2014) · Lab on a Chip · doi:10.1039/c4lc00615a · Cited by 112
Approaching the in vitro clinical trial: engineering organs on chips
Capulli, A. K., Tian, K., Mehandru, N., Bukhta, A., Choudhury, S. F., Suchyta, M., & Parker, K. K. (2014) · Lab on a Chip · doi:10.1039/c4lc00276h · Cited by 111
Acoustophoretic Sorting of Viable Mammalian Cells in a Microfluidic Device
Yang, A. H. J., & Soh, H. T. (2012) · Analytical Chemistry · doi:10.1021/ac3026674 · Cited by 111 · cited 2×
“Generally, the structural deformation and deflection of the circular membrane resulting from the moving fluid can be calculated by the displacement-force relationship of an elastic membrane shown in equation (2)49.”
BackgroundMethodA self-bended piezoresistive microcantilever flow sensor for low flow rate measurement
Zhang, Q., Ruan, W., Wang, H., Zhou, Y., Wang, Z., & Liu, L. (2010) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2010.02.002 · Cited by 110
2-D Micromachined Thermal Wind Sensors—A Review
Zhu, Y.-Q., Chen, B., Qin, M., & Huang, Q. (2014) · IEEE Internet of Things Journal · doi:10.1109/jiot.2014.2319296 · Cited by 107
A magnetic nanocomposite for biomimetic flow sensing
Alfadhel, A., Li, B., Zaher, A., Yassine, O., & Kosel, J. (2014) · Lab on a Chip · doi:10.1039/c4lc00821a · Cited by 106
Droplet motion in microfluidic networks: Hydrodynamic interactions and pressure-drop measurements
Sessoms, D. A., Belloul, M., Engl, W., Roché, M., Courbin, L., & Panizza, P. (2009) · Physical Review E · doi:10.1103/physreve.80.016317 · Cited by 100
Liu, M.-C., Shih, H.-C., Wu, J., Weng, T.-W., Wu, C., Lu, J.-C., & Tung, Y. (2013) · Lab on a Chip · doi:10.1039/c3lc41414k · Cited by 96
A microfluidic circulatory system integrated with capillary-assisted pressure sensors
Chen, Y., Chan, H. N., Michael, S. A., Shen, Y., Chen, Y., Tian, Q., Huang, L., & Wu, H. (2017) · Lab on a Chip · doi:10.1039/c6lc01427e · Cited by 82
A method for dynamic system characterization using hydraulic series resistance
Kim, D., Chesler, N. C., & Beebe, D. J. (2006) · Lab on a Chip · doi:10.1039/b517054k · Cited by 78
Optofluidic imaging: now and beyond
Zhao, Y., Stratton, Z. S., Guo, F., Lapsley, M. I., Chan, C. Y., Lin, S. S., & Huang, T. J. (2012) · Lab on a Chip · doi:10.1039/c2lc90127g · Cited by 74
Microfluidic generation of hollow Ca-alginate microfibers
Meng, Z., Wang, W., Xie, R., Ju, X., Liu, Z., & Chu, L. (2016) · Lab on a Chip · doi:10.1039/c6lc00640j · Cited by 69
Microfabricated suspensions for electrical connections on the tunable elastomer membrane
Hung, P. J., Jeong, K., Liu, G. L., & Lee, L. P. (2004) · Applied Physics Letters · doi:10.1063/1.1835553 · Cited by 61
Multiplex pressure measurement in microsystems using volume displacement of particle suspensions
Chung, K., Lee, H., & Lu, H. (2009) · Lab on a Chip · doi:10.1039/b911480g · Cited by 36
Biosensors in Microfluidic Chips
Noh, J., Kim, H. C., & Chung, T. D. (2011) · Topics in current chemistry · doi:10.1007/128_2011_143 · Cited by 27
Zhang, L., Yu, X., You, S., Liu, H., Zhang, C., Cai, B., Liang, X. M., Liu, W., Guo, S., & Zhao, X. (2015) · Applied Physics Letters · doi:10.1063/1.4937733 · Cited by 24
Continuous flow generation of magnetoliposomes in a low-cost portable microfluidic platform
Conde, A. J., Batalla, M., Cerda, M. B., Mykhaylyk, O. M., Plank, C., Podhajcer, O. L., Cabaleiro, J. M., Madrid, R. E., & Policastro, L. (2014) · Lab on a Chip · doi:10.1039/c4lc00839a · Cited by 17
Cited by
Baghelani, M., Abbasi, Z., Daneshmand, M., & Light, P. E. (2020) · Scientific Reports · doi:10.1038/s41598-020-69547-1 · Cited by 214
Self-citationAlahnomi, R. A., Zakaria, Z., Yussof, Z. M., Althuwayb, A. A., Alhegazi, A., Alsariera, H., & Rahman, N. A. (2021) · Sensors · doi:10.3390/s21072267 · Cited by 200
Narang, R., Mohammadi, S., Ashani, M. M., Sadabadi, H., Hejazi, H., Zarifi, M. H., & Sanati-Nezhad, A. (2018) · Scientific Reports · doi:10.1038/s41598-018-34001-w · Cited by 180
Self-citation
Metadata
- Authors
- Zarifi, M. H., Sadabadi, H., Hejazi, S. H., Daneshmand, M., & Sanati-Nezhad, A.
- Venue
- Scientific Reports
- Published
- 2018-01-09
- Volume
- 8
- Issue
- 1
- Pages
- 139-139
- ISSN
- 2045-2322 (ISSN-L)
- OpenAlex
- W2781981284
- Cited by
- 170
- References
- 27
- FWCI
- 7.53
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.