Technology Transfer of the Microphysiological Systems: A Case Study of the Human Proximal Tubule Tissue Chip
Open accessThe DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
The adoption of a new technology into basic research, and industrial and clinical settings requires rigorous testing to build confidence in the reproducibility, reliability, robustness, and relevance of these models. Tissue chips are promising new technology, they have the potential to serve as a valuable tool in biomedical research, as well as pharmaceutical development with regards to testing for efficacy and safety. The principal goals of this study were to validate a previously established proximal tubule tissue chip model in an independent laboratory and to extend its utility to testing of nephrotoxic compounds. Here, we evaluated critical endpoints from the tissue chip developer laboratory, focusing on biological relevance (long-term viability, baseline protein and gene expression, ammoniagenesis, and vitamin D metabolism), and toxicity biomarkers. Tissue chip experiments were conducted in parallel with traditional 2D culture conditions using two different renal proximal tubule epithelial cell sources. The results of these studies were then compared to the findings reported by the tissue chip developers. While the overall transferability of this advanced tissue chip platform was a success, the reproducibility with the original report was greatly dependent on the cell source. This study demonstrates critical importance of developing microphysiological platforms using renewable cell sources.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Genotype-Tissue Expression (GTEx) pilot analysis: Multitissue gene regulation in humans
The GTEx Consortium, Ardlie, K. G., Deluca, D. S., Segrè, A. V., Sullivan, T. J., Young, T. R., Gelfand, E. T., Trowbridge, C. A., Maller, J. B., Tukiainen, T., et al. (2015) · Science · doi:10.1126/science.1262110 · Cited by 5,062
Self-citationFrom 3D cell culture to organs-on-chips
Huh, D., Hamilton, G. A., & Ingber, D. E. (2011) · Trends in Cell Biology · doi:10.1016/j.tcb.2011.09.005 · Cited by 1,834
The economics of reproducibility in preclinical research
Freedman, L. P., Cockburn, I. M., & Simcoe, T. S. (2015) · PLOS Biology · doi:10.1371/journal.pbio.1002165 · Cited by 1,055
Bioprinting of 3D convoluted renal proximal tubules on perfusable chips
Homan, K. A., Kolesky, D. B., Skylar-Scott, M. A., Herrmann, J., Obuobi, H., Moisan, A., & Lewis, J. A. (2016) · Scientific Reports · doi:10.1038/srep34845 · Cited by 699
Organoid-on-a-chip and body-on-a-chip systems for drug screening and disease modeling
Skardal, A., Shupe, T., & Atala, A. (2016) · Drug Discovery Today · doi:10.1016/j.drudis.2016.07.003 · Cited by 512
Marx, U. (2016) · ALTEX · doi:10.14573/altex.1603161 · Cited by 295
Duan, Y., Gotoh, N., Yan, Q., Du, Z., Weinstein, A. M., Wang, T., & Weinbaum, S. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0804954105 · Cited by 185
Human vascular microphysiological system for in vitro drug screening
Fernandez, C. E., Yen, R. W., Perez, S. M., Bedell, H. W., Povsic, T. J., Reichert, W. M., & Truskey, G. A. (2016) · Scientific Reports · doi:10.1038/srep21579 · Cited by 93
Shear stress-induced alteration of epithelial organization in human renal tubular cells
Maggiorani, D., Dissard, R., Belloy, M., Saulnier-Blache, J.-S., Casemayou, A., Ducasse, L., Grès, S., Bellière, J., Caubet, C., Bascands, J.-L., et al. (2015) · PLOS ONE · doi:10.1371/journal.pone.0131416 · Cited by 74
Long-term culture of human liver tissue with advanced hepatic functions
Ng, S. S., Xiong, A., Nguyen, K., Masek, M., No, D. Y., Elazar, M., Shteyer, E., Winters, M. A., Voedisch, A., Shaw, K., et al. (2017) · JCI Insight · doi:10.1172/jci.insight.90853 · Cited by 32
Cited by
Organs-on-chips: into the next decade
Low, L. A., Mummery, C., Berridge, B. R., Austin, C. P., & Tagle, D. A. (2021) · Nature Reviews Drug Discovery · doi:10.1038/s41573-020-0079-3 · Cited by 1,029
Organ-on-a-chip meets artificial intelligence in drug evaluation
Deng, S., Li, C., Cao, J., Cui, Z., Du, J., Fu, Z., Yang, H., & Chen, P. (2023) · Theranostics · doi:10.7150/thno.87266 · Cited by 260
Microphysiological Systems Evaluation: Experience of TEX-VAL Tissue Chip Testing Consortium
Rusyn, I., Sakolish, C., Kato, Y., Stephan, C., Vergara, L., Hewitt, P., Bhaskaran, V., Davis, M., Hardwick, R. N., Ferguson, S. S., et al. (2022) · Toxicological Sciences · doi:10.1093/toxsci/kfac061 · Cited by 43
Self-citationLekkala, V. K. R., Kang, S.-Y., Liu, J., Shrestha, S., Acharya, P., Joshi, P., Zolfaghar, M., Lee, M., Vanga, M. G., Jamdagneya, P., et al. (2024) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.4c00179 · Cited by 25
Miller, C. P., Fung, M., Jaeger-Ruckstuhl, C. A., Xu, Y., Warren, E. H., Akilesh, S., & Tykodi, S. S. (2023) · Neoplasia · doi:10.1016/j.neo.2023.100948 · Cited by 19
“Selection of these widely available cellular reagents should encourage adoption and assessment of the reproducibility of this platform by other laboratories, which will be an important step to tissues-and organs-on-chips being more widely utilized [23].”
Background
Metadata
- Authors
- Sakolish, C., Weber, E. J., Kelly, E. J., Himmelfarb, J., Mouneimne, R., Grimm, F. A., House, J. S., Wade, T., Han, A., Chiu, W. A., & Rusyn, I.
- Venue
- Scientific Reports
- Published
- 2018-10-05
- Volume
- 8
- Issue
- 1
- Pages
- 14882-14882
- ISSN
- 2045-2322 (ISSN-L)
- OpenAlex
- W2895351357
- Cited by
- 82
- References
- 10
- FWCI
- 3.87
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Technology Transfer of the Microphysiological Systems: A Case Study of the Human Proximal Tubule Tissue Chip. https://app.cochat.ai/papers/10.1038/s41598-018-33099-2
- The paper
- Sakolish, C., Weber, E. J., Kelly, E. J., Himmelfarb, J., Mouneimne, R., Grimm, F. A., House, J. S., Wade, T., Han, A., Chiu, W. A., & Rusyn, I. (2018). Technology Transfer of the Microphysiological Systems: A Case Study of the Human Proximal Tubule Tissue Chip. Scientific Reports. https://doi.org/10.1038/s41598-018-33099-2
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.