Blended electrospinning with human liver extracellular matrix for engineering new hepatic microenvironments
Open accessThe DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Abstract
Tissue engineering of a transplantable liver could provide an alternative to donor livers for transplant, solving the problem of escalating donor shortages. One of the challenges for tissue engineers is the extracellular matrix (ECM); a finely controlled in vivo niche which supports hepatocytes. Polymers and decellularized tissue scaffolds each provide some of the necessary biological cues for hepatocytes, however, neither alone has proved sufficient. Enhancing microenvironments using bioactive molecules allows researchers to create more appropriate niches for hepatocytes. We combined decellularized human liver tissue with electrospun polymers to produce a niche for hepatocytes and compared the human liver ECM to its individual components; Collagen I, Laminin-521 and Fibronectin. The resulting scaffolds were validated using THLE-3 hepatocytes. Immunohistochemistry confirmed retention of proteins in the scaffolds. Mechanical testing demonstrated significant increases in the Young’s Modulus of the decellularized ECM scaffold; providing significantly stiffer environments for hepatocytes. Each scaffold maintained hepatocyte growth, albumin production and influenced expression of key hepatic genes, with the decellularized ECM scaffolds exerting an influence which is not recapitulated by individual ECM components. Blended protein:polymer scaffolds provide a viable, translatable niche for hepatocytes and offers a solution to current obstacles in disease modelling and liver tissue engineering.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Analysis of Relative Gene Expression Data Using Real-Time Quantitative PCR and the 2−ΔΔCT Method
Livak, K. J., & Schmittgen, T. D. (2001) · Methods · doi:10.1006/meth.2001.1262 · Cited by 180,860
Vascularized and functional human liver from an iPSC-derived organ bud transplant
Takebe, T., Sekine, K., Enomura, M., Koike, H., Kimura, M., Ogaeri, T., Zhang, R.-R., Ueno, Y., Zheng, Y.-W., Koike, N., et al. (2013) · Nature · doi:10.1038/nature12271 · Cited by 2,170
Long-Term Culture of Genome-Stable Bipotent Stem Cells from Adult Human Liver
Huch, M., Gehart, H., van Boxtel, R., Hamer, K., Blokzijl, F., Verstegen, M. M. A., Ellis, E., van Wenum, M., Fuchs, S. A., de Ligt, J., et al. (2015) · Cell · doi:10.1016/j.cell.2014.11.050 · Cited by 1,619
Microscale culture of human liver cells for drug development
Khetani, S. R., & Bhatia, S. N. (2008) · Nature Biotechnology · doi:10.1038/nbt1361 · Cited by 1,219
Bell, C. C., Hendriks, D. F. G., Moro, S. M. L., Ellis, E., Walsh, J., Renblom, A., Fredriksson Puigvert, L., Dankers, A. C. A., Jacobs, F., Snoeys, J., et al. (2016) · Scientific Reports · doi:10.1038/srep25187 · Cited by 739
Generation of Functional Human Hepatic Endoderm From Human Induced Pluripotent Stem Cells
Sullivan, G. J., Hay, D. C., Park, I.-H., Fletcher, J., Hannoun, Z., Payne, C. M., Dalgetty, D., Black, J. R., Ross, J. A., Samuel, K., et al. (2010) · Hepatology · doi:10.1002/hep.23335 · Cited by 445
Self-citationDecellularized human liver as a natural 3D-scaffold for liver bioengineering and transplantation
Mazza, G., Rombouts, K., Rennie Hall, A., Urbani, L., Vinh Luong, T., Al-Akkad, W., Longato, L., Brown, D., Maghsoudlou, P., Dhillon, A. P., et al. (2015) · Scientific Reports · doi:10.1038/srep13079 · Cited by 415
The impact of detergents on the tissue decellularization process: A ToF-SIMS study
White, L. J., Taylor, A. J., Faulk, D. M., Keane, T. J., Saldin, L. T., Reing, J. E., Swinehart, I. T., Turner, N. J., Ratner, B. D., & Badylak, S. F. (2017) · Acta Biomaterialia · doi:10.1016/j.actbio.2016.12.033 · Cited by 268
Lee, J. S., Shin, J., Park, H.-M., Kim, Y.-G., Kim, B.-G., Oh, J.-W., & Cho, S.-W. (2014) · Biomacromolecules · doi:10.1021/bm4015039 · Cited by 236
The hepatic extracellular matrix: I. Components and distribution in normal liver
Martinez-Hernandez, A., & Amenta, P. S. (1993) · Virchows Archiv A Pathological Anatomy and Histopathology · doi:10.1007/bf01606425 · Cited by 200
Cited by
Scaffolding Strategies for Tissue Engineering and Regenerative Medicine Applications
Pina, S., Ribeiro, V. P., Marques, C. F., Maia, F. R., Silva, T. H., Reis, R. L., & Oliveira, J. M. (2019) · Materials · doi:10.3390/ma12111824 · Cited by 493
Brown, M., Li, J., Moraes, C., Tabrizian, M., & Li-Jessen, N. Y. K. (2022) · Biomaterials · doi:10.1016/j.biomaterials.2022.121786 · Cited by 282
Willemse, J., van Tienderen, G., van Hengel, E., Schurink, I., van der Ven, D., Kan, Y., de Ruiter, P., Rosmark, O., Westergren-Thorsson G, G., Schneeberger, K., et al. (2022) · Biomaterials · doi:10.1016/j.biomaterials.2022.121473 · Cited by 106
Olgasi, C., Cucci, A., & Follenzi, A. (2020) · International Journal of Molecular Sciences · doi:10.3390/ijms21176215 · Cited by 100
3D bioprinting of multi-material decellularized liver matrix hydrogel at physiological temperatures
Khati, V., Ramachandraiah, H., Pati, F., Svahn, H. A., Gaudenzi, G., & Russom, A. (2022) · Biosensors · doi:10.3390/bios12070521 · Cited by 46
Metadata
- Authors
- Grant, R., Hallett, J., Forbes, S., Hay, D., & Callanan, A.
- Venue
- Scientific Reports
- Published
- 2019-04-18
- Volume
- 9
- Issue
- 1
- Pages
- 6293-6293
- ISSN
- 2045-2322 (ISSN-L)
- OpenAlex
- W2936493533
- Cited by
- 90
- References
- 16
- FWCI
- 12.96
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Blended electrospinning with human liver extracellular matrix for engineering new hepatic microenvironments. https://app.cochat.ai/papers/10.1038/s41598-019-42627-7
- The paper
- Grant, R., Hallett, J., Forbes, S., Hay, D., & Callanan, A. (2019). Blended electrospinning with human liver extracellular matrix for engineering new hepatic microenvironments. Scientific Reports. https://doi.org/10.1038/s41598-019-42627-7
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.