Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 90

The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.

Wearable piezoelectric mass sensor based on pH sensitive hydrogels for sweat pH monitoring

Scarpa, E., Mastronardi, V. M., Guido, F., Algieri, L., Qualtieri, A., Fiammengo, R., Rizzi, F., De Vittorio, M. · 2020 · Scientific Reports

Abstract

Colorimetric and electrochemical (bio)sensors are commonly employed in wearable platforms for sweat monitoring; nevertheless, they suffer from low stability of the sensitive element. In contrast, mass-(bio)sensors are commonly used for analyte detection at laboratory level only, due to their rigidity. To overcome these limitations, a flexible mass-(bio)sensor for sweat pH sensing is proposed. The device exploits the flexibility of piezoelectric AlN membranes fabricated on a polyimide substrate combined to the sensitive properties of a pH responsive hydrogel based on PEG-DA/CEA molecules. A resonant frequency shift is recorded due to the hydrogel swelling/shrinking at several pH. Our device shows a responsivity of about 12 kHz/pH unit when measured in artificial sweat formulation in the pH range 3–8. To the best of our knowledge, this is the first time that hydrogel mass variations are sensed by a flexible resonator, fostering the development of a new class of compliant and wearable devices.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/s41598-020-67706-y

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 10 references

Research works printed but not linked: 34

  1. Steinhubl, S. R., Muse, E. D. & Topol, E. J. The emerging field of mobile health. Sci. Transl. Med. 7, 283rv3. https://doi.org/10.1126/scitranslmed.aaa3487 (2015). · DOI · Paper page
  2. Gatzoulis, L. & Iakovidis, I. Wearable and portable eHealth systems. IEEE Eng. Med. Biol. Mag. 26, 51–56. https://doi.org/10.1109/EMB.2007.901787 (2007). · DOI · Paper page
  3. Qian, R.-C. & Long, Y.-T. Wearable chemosensors: a review of recent progress. ChemistryOpen 7, 118–130. https://doi.org/10.1002/open.201700159 (2018). · DOI
  4. Mena-Bravo, A. & Luque de Castro, M. D. Sweat: a sample with limited present applications and promising future in metabolomics. J. Pharm. Biomed. Anal. 90, 139–147. https://doi.org/10.1016/j.jpba.2013.10.048 (2014). · DOI · Paper page
  5. Beauchamp, M. & Lands, L. C. Sweat-testing: a review of current technical requirements. Pediatr. Pulmonol. 39, 507–511. https://doi.org/10.1002/ppul.20226 (2005). · DOI
  6. Sonner, Z. et al. The microfluidics of the eccrine sweat gland, including biomarker partitioning, transport, and biosensing implications. Biomicrofluidics 9, 031301. https://doi.org/10.1063/1.4921039 (2015). · DOI · Paper page
  7. Nikolajek, W. P. & Emrich, H. M. pH of sweat of patients with cystic fibrosis. Klinische Wochenschrift 54, 287–288. https://doi.org/10.1007/BF01468925 (1976). · DOI
  8. Nakata, S., Arie, T., Akita, S. & Takei, K. Wearable, flexible, and multifunctional healthcare device with an ISFET chemical sensor for simultaneous sweat PH and skin temperature monitoring. ACS Sens. 2, 443–448. https://doi.org/10.1021/acssensors.7b00047 (2017). · DOI · Paper page
  9. Diculescu, V. C. et al. Palladium/palladium oxide coated electrospun fibers for wearable sweat pH-sensors. Sci. Rep. 9, 8902. https://doi.org/10.1038/s41598-019-45399-2 (2019). · DOI
  10. Chung, M., Fortunato, G. & Radacsi, N. Wearable flexible sweat sensors for healthcare monitoring: a review. J. R. Soc. Interface 16, 20190217. https://doi.org/10.1098/rsif.2019.0217 (2019). · DOI · Paper page
  11. Sonawane, A., Manickam, P. & Bhansali, S. Stability of enzymatic biosensors for wearable applications. IEEE Rev. Biomed. Eng. 10, 174–186. https://doi.org/10.1109/RBME.2017.2706661 (2017). · DOI
  12. Dhanjai, et al. Polymer hydrogel interfaces in electrochemical sensing strategies: a review. Trends Anal. Chem. 118, 488–501. https://doi.org/10.1016/j.trac.2019.06.014 (2019). · DOI
  13. Culver, H. R., Clegg, J. R. & Peppas, N. A. Analyte-responsive hydrogels: intelligent materials for biosensing and drug delivery. Acc. Chem. Res. 50, 170–178. https://doi.org/10.1021/acs.accounts.6b00533 (2017). · DOI · Paper page
  14. Goy, C. B., Chaile, R. E. & Madrid, R. E. Microfluidics and hydrogel: a powerful combination. React. Funct. Polym. 145, 104314. https://doi.org/10.1016/j.reactfunctpolym.2019.104314 (2019). · DOI
  15. Banerjee, H., Suhail, M. & Ren, H. Hydrogel actuators and sensors for biomedical soft robots: brief overview with impending challenges. Biomimetics 3, 15 (2018). · DOI · Paper page
  16. Peterson, D. S. Encyclopedia of Microfluidics and Nanofluidics 1–5 (Springer, New York, 2013).
  17. Sannino, A., Pappadà, S., Giotta, L., Valli, L. & Maffezzoli, A. Spin coating cellulose derivatives on quartz crystal microbalance plates to obtain hydrogel-based fast sensors and actuators. J. Appl. Polym. Sci. 106, 3040–3050. https://doi.org/10.1002/app.25899 (2007). · DOI
  18. Dou, Q. et al. High performance boronic acid-containing hydrogel for biocompatible continuous glucose monitoring. RSC Adv. 7, 41384–41390 (2017). · DOI · Paper page
  19. Millet, L. J. et al. Characterization of mass and swelling of hydrogel microstructures using MEMS resonant mass sensor arrays. Small 8, 2555–2562. https://doi.org/10.1002/smll.201200470 (2012). · DOI
  20. del Rey, M. et al. Monitoring swelling and deswelling of thin polymer films by microcantilever sensors. Sens. Actuators B Chem. 204, 602–610 (2014). · doi:10.1016/j.snb.2014.08.021
  21. Bose, S., Keller, S. S., Boisen, A. & Almdal, K. Microcantilever sensors for fast analysis of enzymatic degradation of poly (d,l-lactide). Polym. Degrad. Stab. 119, 1–8 (2015). · DOI
  22. Natta, L. et al. Soft and flexible piezoelectric smart patch for vascular graft monitoring based on aluminum nitride thin film. Sci. Rep. https://doi.org/10.1038/s41598-019-44784-1 (2019). · DOI
  23. Ge, C. & Cretu, E. A sacrificial-layer-free fabrication technology for MEMS transducer on flexible substrate. Sens. Actuators A 286, 202–210. https://doi.org/10.1016/j.sna.2018.12.049 (2019). · doi:10.1016/j.sna.2018.12.049
  24. Lamanna, L. et al. Flexible and transparent aluminum-nitride-based surface-acoustic-wave device on polymeric polyethylene naphthalate. Adv. Electron. Mater. https://doi.org/10.1002/aelm.201900095 (2019). · DOI
  25. Wang, X., Liu, Z. & Zhang, T. Flexible sensing electronics for wearable/attachable health monitoring. Small 13, 1602790. https://doi.org/10.1002/smll.201602790 (2017). · DOI · Paper page
  26. Mastronardi, V. M. et al. Low stiffness tactile transducers based on AlN thin film and polyimide. Appl. Phys. Lett. 106, 162901. https://doi.org/10.1063/1.4918749 (2015). · DOI
  27. Abgrall, P., Conedera, V., Camon, H., Gue, A. M. & Nguyen, N. T. SU-8 as a structural material for labs-on-chips and microelectromechanical systems. Electrophoresis 28, 4539–4551 (2007). · DOI · Paper page
  28. Voskerician, G. et al. Biocompatibility and biofouling of MEMS drug delivery devices. Biomaterials 24, 1959–1967 (2003). · DOI · Paper page
  29. Nemani, K. V., Moodie, K. L., Brennick, J. B., Su, A. & Gimi, B. In vitro and in vivo evaluation of SU-8 biocompatibility. Mater. Sci. Eng. C 33, 4453–4459 (2013). · DOI · Paper page
  30. Yuk, H., Zhang, T., Lin, S., Parada, G. A. & Zhao, X. Tough bonding of hydrogels to diverse non-porous surfaces. Nat. Mater. 15, 190 (2016). · DOI · Paper page
  31. Scarpa, E. et al. Microfabrication of pH-responsive 3D hydrogel structures via two-photon polymerization of high-molecular-weight poly(ethylene glycol) diacrylates. Sens. Actuators B Chem. 279, 418–426. https://doi.org/10.1016/j.snb.2018.09.079 (2019). · DOI
  32. Brand, O. et al. Resonant MEMS: Fundamentals, Implementation, and Application (Wiley, Hoboken, 2015). · DOI
  33. Curto, V. F., Coyle, S., Byrne, R., Diamond, D. & Benito-Lopez, F. Real-time sweat analysis: concept and development of an autonomous wearable micro-fluidic platform. Procedia Eng. 25, 1561–1564. https://doi.org/10.1016/j.proeng.2011.12.386 (2011). · DOI
  34. Aydin, D. et al. Polymeric substrates with tunable elasticity and nanoscopically controlled biomolecule presentation. Langmuir 26, 15472–15480 (2010). · DOI

Cited by

See all 90

Metadata

Authors
Scarpa, E., Mastronardi, V. M., Guido, F., Algieri, L., Qualtieri, A., Fiammengo, R., Rizzi, F., & De Vittorio, M.
Venue
Scientific Reports
Published
2020-07-02
Volume
10
Issue
1
ISSN
2045-2322
Cited by
90
References
10
Language
en
Licence

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Wearable piezoelectric mass sensor based on pH sensitive hydrogels for sweat pH monitoring. https://app.cochat.ai/papers/10.1038/s41598-020-67706-y
The paper
Scarpa, E., Mastronardi, V. M., Guido, F., Algieri, L., Qualtieri, A., Fiammengo, R., Rizzi, F., & De Vittorio, M. (2020). Wearable piezoelectric mass sensor based on pH sensitive hydrogels for sweat pH monitoring. Scientific Reports. https://doi.org/10.1038/s41598-020-67706-y

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.