The DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.
Continuous cuffless blood pressure monitoring with a wearable ring bioimpedance device
Open accessAbstract
Smart rings provide unique opportunities for continuous physiological measurement. They are easy to wear, provide little burden in comparison to other smart wearables, are suitable for nocturnal settings, and can be sized to provide ideal contact between the sensors and the skin at all times. Continuous measuring of blood pressure (BP) provides essential diagnostic and prognostic value for cardiovascular health management. However, conventional ambulatory BP measurement devices operate using an inflating cuff that is bulky, intrusive, and impractical for frequent or continuous measurements. We introduce ring-shaped bioimpedance sensors leveraging the deep tissue sensing ability of bioimpedance while introducing no sensitivity to skin tones, unlike optical modalities. We integrate unique human finger finite element model with exhaustive experimental data from participants and derive optimum design parameters for electrode placement and sizes that yields highest sensitivity to arterial volumetric changes, with no discrimination against varying skin tones. BP is constructed using machine learning algorithms. The ring sensors are used to estimate arterial BP showing peak correlations of 0.81, and low error (systolic BP: 0.11 ± 5.27 mmHg, diastolic BP: 0.11 ± 3.87 mmHg) for >2000 data points and wide BP ranges (systolic: 89-213 mmHg and diastolic: 42-122 mmHg), highlighting the significant potential use of bioimpedance ring for accurate and continuous estimation of BP.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Figures








Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Additionally, other types of devices are being evaluated for similar purposes, including a”
From Unlocking Tomorrow’s Health Care: Expanding the Clinical Scope of Wearables by Applying Artificial Intelligence (2024) · cites this paper as [26]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The validity and practicality of sun-reactive skin types I through VI
Fitzpatrick, T. B. (1988) · Archives of Dermatology · doi:10.1001/archderm.1988.01670060015008 · Cited by 4,339
Compilation of the Dielectric Properties of Body Tissues at RF and Microwave Frequencies.
Gabriel, C. (1996) · doi:10.21236/ada303903 · Cited by 2,108
Definitions and Diagnosis of Pulmonary Hypertension
Hoeper, M. M., Bogaard, H. J., Condliffe, R., Frantz, R. P., Khanna, D., Kurzyna, M., Langleben, D., Manes, A., Satoh, T., Torres, F., et al. (2013) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2013.10.032 · Cited by 1,763
Investigating sources of inaccuracy in wearable optical heart rate sensors
Bent, B., Goldstein, B. A., Kibbe, W. A., & Dunn, J. P. (2020) · npj Digital Medicine · doi:10.1038/s41746-020-0226-6 · Cited by 673
Graphene Electronic Tattoo Sensors
Kabiri Ameri, S., Ho, R., Jang, H., Tao, L., Wang, Y., Wang, L., Schnyer, D. M., Akinwande, D., & Lu, N. (2017) · ACS Nano · doi:10.1021/acsnano.7b02182 · Cited by 669
Stergiou, G. S., Alpert, B., Mieke, S., Asmar, R., Atkins, N., Eckert, S., Frick, G., Friedman, B., Graßl, T., Ichikawa, T., et al. (2018) · Hypertension · doi:10.1161/hypertensionaha.117.10237 · Cited by 469
Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring
Fine, J., Branan, K. L., Rodriguez, A. J., Boonya-ananta, T., Ajmal, Ramella-Roman, J. C., McShane, M. J., & Coté, G. L. (2021) · Biosensors · doi:10.3390/bios11040126 · Cited by 348
Sympathetic Neural Mechanisms in Human Cardiovascular Health and Disease
Charkoudian, N., & Rabbitts, J. A. (2009) · Mayo Clinic Proceedings · doi:10.4065/84.9.822 · Cited by 270
Continuous cuffless monitoring of arterial blood pressure via graphene bioimpedance tattoos
Kireev, D., Sel, K., Ibrahim, B., Kumar, N., Akbari, A., Jafari, R., & Akinwande, D. (2022) · Nature Nanotechnology · doi:10.1038/s41565-022-01145-w · Cited by 249
Self-citationSoft Wearable Pressure Sensors for Beat‐to‐Beat Blood Pressure Monitoring
Kim, J. P., Chou, E., Le, J., Wong, S., Chu, M. L., & Khine, M. (2019) · Advanced Healthcare Materials · doi:10.1002/adhm.201900109 · Cited by 241
Research works printed but not linked: 2
- Grimnes, S. & Martinsen, O. G. Bioimpedance and bioelectricity basics. (Academic press, 2011).
- Kireev, D. et al. Continuous cuffless monitoring of arterial blood pressure via graphene bioimpedance tattoos. Nat. Nanotechnol. 17, 864–870 (2022). · DOI
Cited by
Sorted by citations
Self-Powered Sensing in Wearable Electronics─A Paradigm Shift Technology
Tang, W., Sun, Q., & Wang, Z. L. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00305 · Cited by 332
Transforming Cardiovascular Care With Artificial Intelligence: From Discovery to Practice
Khera, R., Oikonomou, E. K., Nadkarni, G. N., Morley, J., Wiens, J., Butte, A. J., & Topol, E. J. (2024) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2024.05.003 · Cited by 324
A review on flexible wearables – Recent developments in non-invasive continuous health monitoring
Kazanskiy, N. L., Khonina, S. N., & Butt, M. A. (2024) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2023.114993 · Cited by 216
E-Tattoos: Toward Functional but Imperceptible Interfacing with Human Skin
Li, H., Tan, P., Rao, Y., Bhattacharya, S., Wang, Z., Kim, S., Gangopadhyay, S., Shi, H., Jankovic, M., Huh, H., et al. (2024) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00626 · Cited by 144
Sel, K., Hawkins-Daarud, A. J., Chaudhuri, A., Osman, D., Bahai, A. R. S., Paydarfar, D., Willcox, K. E., Chung, C., & Jafari, R. (2025) · npj Digital Medicine · doi:10.1038/s41746-025-01447-y · Cited by 148
Self-citationConsumer Wearable Health and Fitness Technology in Cardiovascular Medicine
Petek, B. J., Al‐Alusi, M. A., Moulson, N., Grant, A. J., Besson, C., Guseh, J. S., Wasfy, M. M., Grémeaux, V., Churchill, T. W., & Baggish, A. L. (2023) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2023.04.054 · Cited by 113
Sel, K., Mohammadi, A., Pettigrew, R. I., & Jafari, R. (2023) · npj Digital Medicine · doi:10.1038/s41746-023-00853-4 · Cited by 95
Self-citationParupelli, S. K., & Desai, S. S. (2023) · Bioengineering · doi:10.3390/bioengineering11010032 · Cited by 69
Cuffless Blood Pressure in clinical practice: challenges, opportunities and current limits.
Henry, B., Merz, M., Hoang, H., Abdulkarim, G., Wosik, J., & Schoettker, P. (2024) · Blood Pressure · doi:10.1080/08037051.2024.2304190 · Cited by 55
Liu, Z.-D., Li, Y., Zhang, Y., Zeng, J., Chen, Z.-X., Liu, J., & Miao, F. (2024) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2024.3395445 · Cited by 52
Recent Advances in the Wearable Devices for Monitoring and Management of Heart Failure
Odeh, V. A., Chen, Y., Wang, W., & Ding, X. (2024) · Reviews in Cardiovascular Medicine · doi:10.31083/j.rcm2510386 · Cited by 54
Emerging intelligent wearable devices for cardiovascular health monitoring
Wang, Y., Zou, Y., & Li, Z. (2024) · Nano Today · doi:10.1016/j.nantod.2024.102544 · Cited by 38
Petrušić, I., Chiang, C., García‐Azorín, D., Ha, W., Ornello, R., Pellesi, L., Rubio‐Beltrán, E., Ruscheweyh, R., Waliszewska‐Prosół, M., & Wells-Gatnik, W. D. (2025) · The Journal of Headache and Pain · doi:10.1186/s10194-024-01944-7 · Cited by 36
Marvasti, T. B., Gao, Y., Murray, K. R., Hershman, S., McIntosh, C., & Moayedi, Y. (2024) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2024.07.009 · Cited by 35
Advances in Cardiovascular Wearable Devices
Iqbal, S. M. A., Leavitt, M. A., Mahgoub, I., & Asghar, W. (2024) · Biosensors · doi:10.3390/bios14110525 · Cited by 37
Artificial intelligence-enhanced patient evaluation: bridging art and science
Oikonomou, E. K., & Khera, R. (2024) · European Heart Journal · doi:10.1093/eurheartj/ehae415 · Cited by 34
PPG and Bioimpedance-Based Wearable Applications in Heart Rate Monitoring—A Comprehensive Review
Lapsa, D., Janeliukštis, R., Metshein, M., & Selavo, L. (2024) · Applied Sciences · doi:10.3390/app14177451 · Cited by 30
Al‐Shami, A., Ma, H., Banks, M., Amirghasemi, F., Mohamed, M. A., Soleimani, A., Nejad, S. K., Ong, V., Tasso, A., Berkmen, A., et al. (2025) · Advanced Functional Materials · doi:10.1002/adfm.202420973 · Cited by 30
Mechanics and bio-interface engineering in flexible biosensors for continuous health monitoring
Qaiser, N., Suryaprabha, T., Vetrano, F., Hwang, B., & El‐Atab, N. (2026) · npj Flexible Electronics · doi:10.1038/s41528-025-00524-2 · Cited by 32
Dai, P., Cong, Z., Sun, Y. Y., Yan, W., Chen, P., Wang, X., & Jiang, C. (2024) · Measurement · doi:10.1016/j.measurement.2024.114874 · Cited by 26
Aspects of 6th generation sensing technology: from sensing to sense
Mazumdar, H., Khondakar, K. R., Das, S., & Kaushik, A. K. (2024) · Frontiers in Nanotechnology · doi:10.3389/fnano.2024.1434014 · Cited by 26
Transfer Learning Enhanced Blood Pressure Monitoring Based on Flexible Optical Pulse Sensing Patch
Liu, Z., Xiang, C., Tong, Y., Li, K. H., & Guan, X. (2025) · ACS Sensors · doi:10.1021/acssensors.4c03404 · Cited by 20
From Wearables to Implantables: Harnessing Sensor Technologies for Continuous Health Monitoring
Koruprolu, A., Hack, T., Ghadami, O., Jain, A., & Hall, D. A. (2025) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2025.3568754 · Cited by 20
Xiang, T., Jin, Y., Liu, Z., Clifton, L., Clifton, D. A., Zhang, Y., Zhang, Q., Ji, N., & Zhang, Y. (2025) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2025.3548771 · Cited by 20
Wearable Blood Pressure Monitoring Devices: Understanding Heterogeneity in Design and Evaluation
Cheung, M. Y., Sabharwal, A., Coté, G. L., & Veeraraghavan, A. (2024) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2024.3434344 · Cited by 23
Liang, C., Zhou, J., Qiu, S., Zhao, L., Mao, X., Yang, X., Zhang, Y., & Zhao, N. (2025) · Nature Communications · doi:10.1038/s41467-025-67118-4 · Cited by 17
Shen, Z., Li, J., Hu, H., Du, C., Ding, X., Pan, T., & Yu, X. (2025) · AI Sensors · doi:10.3390/aisens1020008 · Cited by 12
Baker, S., Yogavijayan, T., & Kandasamy, Y. (2023) · Healthcare · doi:10.3390/healthcare11243107 · Cited by 11
Cuffless Blood Pressure Monitor for Home and Hospital Use
TAMURA, T., & Huang, M. (2025) · Sensors · doi:10.3390/s25030640 · Cited by 11
Garrett, A., Kim, B., Gurel, N. Z., Sie, E. J., Wilson, B. K., Marsili, F., Forman, J. P., Hamburg, N. M., Boas, D. A., & Roblyer, D. M. (2025) · Biomedical Optics Express · doi:10.1364/boe.560022 · Cited by 12
Yang, B., Liu, L., Wu, W., Zhou, M., Liu, H., & Ning, X. (2023) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2023.3346527 · Cited by 9
Ring-Type Biomedical Eddy Current Sensor for Continuous Blood Pressure Monitoring
Ni, S.-H., Sung, Y., Hsu, D.-Y., Huang, C.-Y., Lai, D.-N., & Wang, T.-W. (2024) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2024.3450913 · Cited by 11
Fully Integrated Flexible Electromagnetic Induction-Based Patch for Noncontact Health Monitoring
Hsu, D.-Y., Sung, Y., Lyu, E.-Z., Huang, C.-Y., Huang, Y.-X., Chang, C.-C., Tsai, Y.-S., Chen, C.-K., Ni, S.-H., Chen, Y.-J., et al. (2025) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2025.3554322 · Cited by 10
Hsiao, C., Hong, S., Branan, K. L., McMurray, J. P., & Coté, G. L. (2025) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2025.110357 · Cited by 9
PITN: Physics-Informed Temporal Networks for Cuffless Blood Pressure Estimation
Wang, R., Qi, M., Shao, Y., Zhou, A., & Ma, H. (2025) · IEEE Transactions on Mobile Computing · doi:10.1109/tmc.2025.3627091 · Cited by 9
Danesh, H., Shirzadfar, H., Manian, M., & Pazhom, M. (2025) · Smart Wearable Technology · doi:10.47852/bonviewswt52026420 · Cited by 8
Maged, R., El‑Hameed, A. S. A., & Hamad, E. K. I. (2025) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2025.117132 · Cited by 8
Metshein, M., Abdullayev, A., Gautier, A., Larras, B., Frappé, A., Cardiff, B., Annus, P., Land, R., & Märtens, O. (2023) · Sensors · doi:10.3390/s23167111 · Cited by 8
Electrical bioimpedance in the era of artificial intelligence
Hou, J., Nesaragi, N., & Tronstad, C. (2024) · Journal of Electrical Bioimpedance · doi:10.2478/joeb-2024-0001 · Cited by 8
A Skin-Tone Insensitive, Fully Integrated Smartwatch for Continuous Blood Pressure Measurement
Huang, C.-Y., Sung, Y., Ni, S.-H., & Wang, T.-W. (2024) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2024.3502829 · Cited by 7
Sensor for cardiovascular health status monitoring: A review
Petronienė, J. J., Vaičiūnas, G., Garbinčius, G., Dzedzickis, A., & Bučinskas, V. (2025) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2025.116720 · Cited by 7
Smart Ring in Clinical Medicine: A Systematic Review
Gong, E. J., Bang, C. S., Lee, J. J., & Baik, G. H. (2025) · Biomimetics · doi:10.3390/biomimetics10120819 · Cited by 6
Artificial Intelligence-Driven Wearable Sensors for Cardiovascular Health Monitoring
Deng, H. T., Ma, B., Chen, G., Chi, J., Tong, J., Yu, F., Lü, B., Chen, Y., Zhao, C., Zhang, C., et al. (2026) · ACS Sensors · doi:10.1021/acssensors.5c04840 · Cited by 6
Wearable Bioimpedance Sensor Characterization for Blood Flow Monitoring
Sel, K., Asgar, S. A. G., Osman, D., Wu, P., & Jafari, R. (2023) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas58349.2023.10388901 · Cited by 6
Self-citationSharma, S., Pradhan, G. B., Lim, S., Sapkota, S., Lee, Y., & Park, J. Y. (2025) · Advanced Functional Materials · doi:10.1002/adfm.202516764 · Cited by 5
Continuous Monitoring of Body Fluid by Flexible Bio‐Integrated Flow Sensors
Ma, Z., Zhang, D., Sabri, M. F. M., & Jiang, Y. (2026) · Advanced Materials · doi:10.1002/adma.202523029 · Cited by 5
Wu, X., Zhu, C., Zheng, L., Song, Y., Wang, J., Zhang, X., Yao, Z., Han, Y., Wang, Z., Jiang, Z., et al. (2026) · Nature Sensors · doi:10.1038/s44460-026-00044-0 · Cited by 5
Signal Acquisition and Algorithm Design for Bioimpedance-Based Heart Rate Estimation from the Wrist
Lapsa, D., Metshein, M., Krivošei, A., Janeliukštis, R., Märtens, O., & Elsts, A. (2024) · Applied Sciences · doi:10.3390/app14219632 · Cited by 6
A Novel Wearable Device for Continuous Blood Pressure Monitoring Utilizing Strain Gauge Technology
McMurray, J. P., DeVries, A., Frazee, K. P., Sizemore, B., Branan, K. L., Jennings, R., & Coté, G. L. (2025) · Biosensors · doi:10.3390/bios15070413 · Cited by 6
Robust Peak Detection for Photoplethysmography Signal Analysis
Goda, M. Á., Charlton, P. H., & Behar, J. A. (2023) · Computing in cardiology · doi:10.22489/cinc.2023.189 · Cited by 5
Xiang, T., Zhang, Y., & Zhang, Y. (2024) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc53108.2024.10782499 · Cited by 5
Wearable multimodal sensing for geriatric healthcare
Kim, B., Ding, S., & Wang, J. (2026) · Soft Science · doi:10.20517/ss.2026.14 · Cited by 4
Wireless arm-worn bioimpedance sensor for continuous assessment of whole-body hydration
Jankovic, M., Kang, S.-M., Bhattacharya, S., Kashanchi, J., Wang, J., Deoli, K., Huang, T., Johnson, A., Ambani, K., Kim, S., et al. (2025) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2504278122 · Cited by 4
Ma, Z., Caldwell, R., Attia, Z. I., Friedman, P. A., Lerman, A., Ng, C. T., & Herrmann, J. (2026) · Trends in Cardiovascular Medicine · doi:10.1016/j.tcm.2026.01.006 · Cited by 4
Recent progress in blood flow sensing
Chen, R. Y., Liang, J., Li, M., & Meng, E. F. (2025) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2025.116457 · Cited by 3
Cardiovascular digital twins using a Windkessel physics informed neural network
Osman, D., Sel, K., Spatz, E. S., & Jafari, R. (2026) · npj Digital Medicine · doi:10.1038/s41746-026-02610-9 · Cited by 3
Self-citationPetrova, G. I., Radev, H., Shopov, M., & Kakanakov, N. R. (2025) · Applied Sciences · doi:10.3390/app15137609 · Cited by 3
VisRing: A Display-Extended Smartring for Nano Visualizations
Lu, T., Krauter, C., Liu, R., Schulte, M., Achberger, A., Blascheck, T., Sedlmair, M., & Gowda, M. (2025) · ACM Symposium on User Interface Software and Technology (UIST) · doi:10.1145/3746059.3747806 · Cited by 3
A Wearable Solution of Muscle Atrophy Assessment: Oriented Toward Upper Limb Rehabilitation
Wang, Q., Wang, D., Yang, C., Huang, X., Fang, F., Song, Z., & Xiang, W. D. (2024) · Electronics · doi:10.3390/electronics13204138 · Cited by 2
Advances in principles and technologies of non-mechanical blood pressure monitoring
Zheng, Z., Hao, H., Huang, Y., Lyu, R., Ma, H., Zhang, Y., Liu, J., Shao, C., & Zhou, A. (2026) · npj Cardiovascular Health · doi:10.1038/s44325-025-00102-5 · Cited by 2
Advanced ambulatory and continuous sensing technologies for cardiovascular connected healthcare
Ke, Y., Li, J., Li, T., Xu, W., Ni, D., Ye, X., Li, Z., Yang, F., & Wang, Z. L. (2026) · Nano Energy · doi:10.1016/j.nanoen.2026.112011 · Cited by 2
Learning Human–Environment Interactions via Wearable AI Interfaces
Wen, F., Wang, S., & Zhang, T. (2026) · ACS Nano · doi:10.1021/acsnano.6c05494 · Cited by 2
Recent Progress on Skin-Compatible Flexible Photoplethysmography Sensor
Kim, J., Jeong, J., Lee, H., Kim, D., & Park, S. (2024) · Journal of Flexible and Printed Electronics · doi:10.56767/jfpe.2024.3.2.163 · Cited by 2
Kumar, N., Leo, S., Zhao, J., Lalande, S., & Akinwande, D. (2025) · IEEE MTT-S International Microwave Biomedical Conference (IMBioC) · doi:10.1109/imbioc63524.2025.10989672 · Cited by 1
Lowe, A., Yu, Y., & Chandel, T. (2025) · Journal of Human Hypertension · doi:10.1038/s41371-025-01040-6 · Cited by 1
Nanoelectronic accessory integration: A finger-worn wearable platform for rapid nitrite detection
Hatamie, A., Mohammadlou, S., Haghighi, S. K., Madani, S., & Angizi, S. (2025) · Journal of Electroanalytical Chemistry · doi:10.1016/j.jelechem.2025.119640 · Cited by 1
Maeng, S. J., Park, S., Jo, I. J., Lee, G. T., Hwang, S. Y., Chung, M. J., Kim, J., Yoo, H., & Yoon, H. J. (2025) · Critical Care · doi:10.1186/s13054-025-05772-2 · Cited by 1
Wearable tattoo sensors for human and plants – Current challenges and prospects
Kazanskiy, N. L., Владимирович, Г. Н., & Khonina, S. N. (2025) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2025.117313 · Cited by 1
Zhang, J., Guan, C., Wu, D., Chen, Z., Liu, G., Nie, Y., Shokouhimehr, M., He, F., & Liu, Z. (2026) · Measurement Science and Technology · doi:10.1088/1361-6501/ae3cb4 · Cited by 1
Cuffless Blood Pressure Estimation Using Magnetic Flux In A Ring Form Factor
Asgar, S. A. G., Sel, K., Paul, A., Pettigrew, R. I., & Jafari, R. (2024) · IEEE International Conference on Acoustics Speech and Signal Processing · doi:10.1109/icassp48485.2024.10445982 · Cited by 1
Self-citationAssessment of a Bioimpedance Analog Front-End for Blood Pulse Wave Detection
Imbriglia, M., Picariello, F., Tudosa, I., Vito, L. D., & Daponte, P. (2024) · IEEE International Symposium on Medical Measurements and Applications (MeMeA) · doi:10.1109/memea60663.2024.10596785 · Cited by 1
Boutros, P., Kassem, N., & Barteit, S. (2025) · Progress in molecular biology and translational science · doi:10.1016/bs.pmbts.2025.05.006 · Cited by 1
Li, Z., Lu, T., Liu, R., Yuan, S., Gosalia, J., Bowlus, C. K., Proctor, D. N., Pawelczyk, J. A., Jin, Y., & Gowda, M. (2025) · Proceedings of the ACM on Interactive Mobile Wearable and Ubiquitous Technologies · doi:10.1145/3770689 · Cited by 1
Saadat, M., Sel, K., Peixoto, A. J., Mortazavi, B. J., Spatz, E. S., & Jafari, R. (2025) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc58623.2025.11253195 · Cited by 1
Self-citationGhaemi, S., Rodoshi, R. T., Shultana, S., Shehu, A., & Barbará, D. (2025) · ACM International Conference on Bioinformatics, Computational Biology, and Health Informatics (ACM-BCB) · doi:10.1145/3768322.3769024 · Cited by 1
Agarwal, S., Singh, V. P., Ganguly, P., Munnangi, P., Collins, C., Sarker, S., Shenoi, J., Heston, S., Pandita, S., Pandita, T. K., et al. (2023) · Elsevier eBooks · doi:10.1016/b978-0-12-824010-6.00051-4 · Cited by 1
Self-citationPearls and pitfalls of cuffless blood pressure monitoring devices
Iacobescu, R.-A., Florescu, B.-D., Dimache, A.-M., Corneanu, L. E., & Coman, A. E. (2023) · Romanian Medical Journal · doi:10.37897/rmj.2023.3.2 · Cited by 1
Perspectives of Global Standards on Validation of Blood Pressure Measuring Devices
Fang, J., Ji, N., Deng, M., Du, C., Xiang, T., Liu, Z., Zhang, Y., & Pan, T. (2025) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2025.3587411 · Cited by 1
Garrett, A., Kim, B., Gurel, N. Z., Sie, E. J., Wilson, B. K., Marsili, F., Forman, J. P., Hamburg, N. M., Boas, D. A., & Roblyer, D. M. (2024) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2024.08.16.608163 · Cited by 1
Wearable Dual-Modality Plethysmography for Arterial Modulation and Blood Pressure DipPreprint
Jung, S., & Thomson, S. (2026) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.64898/2026.04.17.719282 · Cited by 1
How individuals perceive and process diagnostic device errors
Becker, M. Y., & Matt, C. (2024) · Journal of Decision System · doi:10.1080/12460125.2024.2354578
Artificial intelligence at the point-of-care in cardio-oncology
Guo, J., & DeCara, J. M. (2025) · Elsevier eBooks · doi:10.1016/b978-0-443-29829-5.00009-8
Liu, Y., Li, J., Jia, S., Lu, Y., Shi, D., & Shi, L. (2025) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2025.3577840
Liu, Z., Kong, X., & Shi, Y. (2025) · Springer eBooks · doi:10.1007/978-981-96-8646-9_7
Feasibility of Estimating Brachial Artery Impedance During Flow-Mediated Dilation Intervention
Shah, S., Sudarsan, N., Manoj, R., Kiran, R. V., Nabeel, P. M., & Joseph, J. (2025) · IEEE International Symposium on Medical Measurements and Applications (MeMeA) · doi:10.1109/memea65319.2025.11068005
Noori, S., Firouzmand, M., Nafisi, V. R., & Hooman, N. (2025) · Journal of Kidney Diseases · doi:10.61882/ijkd.19.04.8556
Smart Skin and Beyond: Unlocking the Full Potential of Wearable Health Sensors
Chaiya, N., Tangkuaram, T., & Moonla, C. (2025) · Springer eBooks · doi:10.1007/978-981-95-2117-3_11
Demonstration of VisRing: A Display-Extended Smartring for Nano Visualizations
Liu, R., Krauter, C., Lu, T., Schulte, M., Achberger, A., Blascheck, T., Sedlmair, M., & Gowda, M. (2025) · ACM Symposium on User Interface Software and Technology (UIST) · doi:10.1145/3746058.3758997
Pradhan, G. B., Sharma, S., & Park, J. Y. (2026) · IEEE International Conference on Micro Electro Mechanical Systems (MEMS) · doi:10.1109/mems64181.2026.11419453
Emerging Role of Technology for Quality Care in the Field of Physiotherapy
Bansal, A., & Sharma, P. (2026) · Journal of Health and Allied Sciences NU · doi:10.25259/jhasnu_140_2025
A Smart Wearable System for Predictive Cardiac Using IoT, ML and RPA
Manasa, M., R, M. P., & Amith Shekhar, C. (2025) · International Conference on Emerging Technologies in Electronics and Green Energy (ICETEG) · doi:10.1109/iceteg66194.2025.11473058
Metshein, M. (2026) · Instruments · doi:10.3390/instruments10020026
Thomson, S., Jung, S., Pantelopoulos, A., Deshpande, A., Cai, L. Z., Blanchard, E., Wasson, M. J., Mukherjee, D., Sunden, L., Sheng, S., et al. (2026) · medRxiv · doi:10.64898/2026.06.17.26355894
Fu, Z., Lyu, L., Zhang, Y., Tin, C., Miao, F., & Chan, R. H. M. (2026) · IEEE Sensors Journal · doi:10.1109/jsen.2026.3709367
Aloui, Z., & Landry, C. (2026) · Artery Research · doi:10.1007/s44200-026-00120-3
Clinical Evaluation of a Multimodal On-Body Sensor ArrayPreprint
Nnadi, B., Rapuri, S., Harris, C., Rattray, J., Tenore, F. V., Gamaldo, C. E., Etienne-Cummings, R., & Stevens, R. D. (2026) · medRxiv · doi:10.64898/2026.07.29.26359254
Blood pressure monitoring via wearable devices and artificial intelligence in hypertension detection
Neri, L., Orro, A., Paolocci, N., Borghi, C., & Bagha, M. (2026) · Journal of Hypertension · doi:10.1097/hjh.0000000000004419
Li, M., Deng, X., Yao, P., Jia, L., Lv, X., Song, Y., Wu, Y., Li, Z., & Liu, Z. (2026) · Nano Energy · doi:10.1016/j.nanoen.2026.112383
All-Fabric Bioimpedance Sensor for Joint Motion Tracking
Patamia, E. D., Mullen, C., & Andrew, T. L. (2026) · IEEE Sensors Journal · doi:10.1109/jsen.2026.3733616
User Attitudes and Technological Adoption in Hypertension Self-Monitoring
Santos, C., Carmichael, J., & Singh, A. (2026) · ACM Transactions on Computing for Healthcare · doi:10.1145/3845799
Metadata
- Authors
- Sel, K., Osman, D., Huerta, N., Edgar, A., Pettigrew, R. I., & Jafari, R.
- Affiliations
- Texas A&M University (US)
- Corresponding author
- Jafari, Roozbeh
- Venue
- npj Digital Medicine
- Published
- 2023-03-30
- Volume
- 6
- Issue
- 1
- Pages
- 59-59
- ISSN
- 2398-6352 (ISSN-L)
- PMC
- PMC10063561
- OpenAlex
- W4361279210
- Cited by
- 100
- References
- 40
- Citations by year
- 2026: 23 · 2025: 41 · 2024: 25 · 2023: 11
- FWCI
- 7.88
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Locations
- npj Digital Medicine (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- U.S. Department of Health & Human Services | NIH | National Heart, Lung, and Blood Institute (1R01HL151240)
- U.S. Department of Health & Human Services | NIH | National Institute of Biomedical Imaging and Bioengineering (1R01EB028106)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrical and Bioimpedance Tomography
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
- Keywords
- cuffless blood pressure measurement, bioimpedance, smart rings, continuous blood pressure estimation, electrode placement optimization, cardiovascular monitoring
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review