The DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.
Continuous cuffless blood pressure monitoring with a wearable ring bioimpedance device
Open accessAbstract
Smart rings provide unique opportunities for continuous physiological measurement. They are easy to wear, provide little burden in comparison to other smart wearables, are suitable for nocturnal settings, and can be sized to provide ideal contact between the sensors and the skin at all times. Continuous measuring of blood pressure (BP) provides essential diagnostic and prognostic value for cardiovascular health management. However, conventional ambulatory BP measurement devices operate using an inflating cuff that is bulky, intrusive, and impractical for frequent or continuous measurements. We introduce ring-shaped bioimpedance sensors leveraging the deep tissue sensing ability of bioimpedance while introducing no sensitivity to skin tones, unlike optical modalities. We integrate unique human finger finite element model with exhaustive experimental data from participants and derive optimum design parameters for electrode placement and sizes that yields highest sensitivity to arterial volumetric changes, with no discrimination against varying skin tones. BP is constructed using machine learning algorithms. The ring sensors are used to estimate arterial BP showing peak correlations of 0.81, and low error (systolic BP: 0.11 ± 5.27 mmHg, diastolic BP: 0.11 ± 3.87 mmHg) for >2000 data points and wide BP ranges (systolic: 89-213 mmHg and diastolic: 42-122 mmHg), highlighting the significant potential use of bioimpedance ring for accurate and continuous estimation of BP.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Figures








Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Additionally, other types of devices are being evaluated for similar purposes, including a”
From Unlocking Tomorrow’s Health Care: Expanding the Clinical Scope of Wearables by Applying Artificial Intelligence (2024) · cites this paper as [26]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The validity and practicality of sun-reactive skin types I through VI
Fitzpatrick, T. B. (1988) · Archives of Dermatology · doi:10.1001/archderm.1988.01670060015008 · Cited by 4,339
Compilation of the Dielectric Properties of Body Tissues at RF and Microwave Frequencies.
Gabriel, C. (1996) · doi:10.21236/ada303903 · Cited by 2,108
Definitions and Diagnosis of Pulmonary Hypertension
Hoeper, M. M., Bogaard, H. J., Condliffe, R., Frantz, R. P., Khanna, D., Kurzyna, M., Langleben, D., Manes, A., Satoh, T., Torres, F., et al. (2013) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2013.10.032 · Cited by 1,763
Investigating sources of inaccuracy in wearable optical heart rate sensors
Bent, B., Goldstein, B. A., Kibbe, W. A., & Dunn, J. P. (2020) · npj Digital Medicine · doi:10.1038/s41746-020-0226-6 · Cited by 673
Graphene Electronic Tattoo Sensors
Kabiri Ameri, S., Ho, R., Jang, H., Tao, L., Wang, Y., Wang, L., Schnyer, D. M., Akinwande, D., & Lu, N. (2017) · ACS Nano · doi:10.1021/acsnano.7b02182 · Cited by 669
Stergiou, G. S., Alpert, B., Mieke, S., Asmar, R., Atkins, N., Eckert, S., Frick, G., Friedman, B., Graßl, T., Ichikawa, T., et al. (2018) · Hypertension · doi:10.1161/hypertensionaha.117.10237 · Cited by 469
Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring
Fine, J., Branan, K. L., Rodriguez, A. J., Boonya-ananta, T., Ajmal, Ramella-Roman, J. C., McShane, M. J., & Coté, G. L. (2021) · Biosensors · doi:10.3390/bios11040126 · Cited by 348
Sympathetic Neural Mechanisms in Human Cardiovascular Health and Disease
Charkoudian, N., & Rabbitts, J. A. (2009) · Mayo Clinic Proceedings · doi:10.4065/84.9.822 · Cited by 270
Continuous cuffless monitoring of arterial blood pressure via graphene bioimpedance tattoos
Kireev, D., Sel, K., Ibrahim, B., Kumar, N., Akbari, A., Jafari, R., & Akinwande, D. (2022) · Nature Nanotechnology · doi:10.1038/s41565-022-01145-w · Cited by 249
Self-citationSoft Wearable Pressure Sensors for Beat‐to‐Beat Blood Pressure Monitoring
Kim, J. P., Chou, E., Le, J., Wong, S., Chu, M. L., & Khine, M. (2019) · Advanced Healthcare Materials · doi:10.1002/adhm.201900109 · Cited by 241
Magder, S. A. (2018) · Critical Care · doi:10.1186/s13054-018-2171-1 · Cited by 234
Nocturnal blood pressure and cardiovascular disease: a review of recent advances
Yano, Y., & Kario, K. (2012) · Hypertension Research · doi:10.1038/hr.2012.26 · Cited by 227
Influence of skin type and wavelength on light wave reflectance
Fallow, B. A., Tarumi, T., & Tanaka, H. (2013) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-013-9436-7 · Cited by 162
A Review of Wearable Multi-Wavelength Photoplethysmography
Ray, D., Collins, T., Woolley, S., & Ponnapalli, P. (2023) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2021.3121476 · Cited by 155
Ding, X., & Zhang, Y. (2019) · Biomedical Engineering Letters · doi:10.1007/s13534-019-00096-x · Cited by 142
Blood Pressure Monitoring for the Anesthesiologist: A Practical Review
Bartels, K., Esper, S. A., & Thiele, R. H. (2016) · Anesthesia & Analgesia · doi:10.1213/ane.0000000000001340 · Cited by 135
Ibrahim, B., & Jafari, R. (2019) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2019.2946661 · Cited by 108
Self-citationFinger arterial pressure measurement with Finapres.
Wesseling, K. H. (1996) · PubMed · Cited by 105
Cuffless Blood Pressure Monitoring: Promises and Challenges
Pandit, J. A., Lores, E., & Batlle, D. (2020) · Clinical Journal of the American Society of Nephrology · doi:10.2215/cjn.03680320 · Cited by 101
Spīgulis, J., Gailite, L., Lihachev, A., & Erts, R. (2007) · Applied Optics · doi:10.1364/ao.46.001754 · Cited by 98
Diagnosis and management of patients with white-coat and masked hypertension
Mancia, G., Bombelli, M., Seravalle, G., & Grassi, G. M. (2011) · Nature Reviews Cardiology · doi:10.1038/nrcardio.2011.115 · Cited by 90
Blood Pressure Measurement by Arterial Tonometry in Controlled Hypotension
Kemmotsu, O., Ueda, M., Otsuka, H., Yamamura, T., Okamura, A., Ishikawa, T., Winter, D. C., & Eckerle, J. S. (1991) · Anesthesia & Analgesia · doi:10.1213/00000539-199107000-00011 · Cited by 88
HISTORY OF BIOIMPEDANCE AND BIOELECTRICITY
Grimnes, S., & Martinsen, Ø. G. (2008) · Elsevier eBooks · doi:10.1016/b978-0-12-374004-5.00010-6 · Cited by 88
Superficial palmar arch: an arterial diameter study
Fazan, V. P. S., Borges, C. T., Silva, J. H. D., Caetano, A. G., & Filho, O. A. R. (2004) · Journal of Anatomy · doi:10.1111/j.0021-8782.2004.00281.x · Cited by 85
Sel, K., Osman, D., & Jafari, R. (2021) · IEEE Open Journal of Engineering in Medicine and Biology · doi:10.1109/ojemb.2021.3085482 · Cited by 63
Self-citationNon-invasive cuff-less blood pressure estimation using a hybrid deep learning model
Yang, S., Zhang, Y., Cho, S., Correia, R. G., & Morgan, S. P. (2021) · Optical and Quantum Electronics · doi:10.1007/s11082-020-02667-0 · Cited by 61
From 3D tissue data to impedance using Simpleware ScanFE+IP and COMSOL Multiphysics – a tutorial
Pettersen, F., & Høgetveit, J. O. (2011) · Journal of Electrical Bioimpedance · doi:10.5617/jeb.173 · Cited by 55
Blood pressure monitoring in sleep: time to wake up
Kwon, Y., Stafford, P. L., Lim, D. C., Park, S., Kim, S., Berry, R. B., & Calhoun, D. A. (2019) · Blood Pressure Monitoring · doi:10.1097/mbp.0000000000000426 · Cited by 53
Single-Channel Bioimpedance Measurement for Wearable Continuous Blood Pressure Monitoring
Wang, T.-W., Chen, W.-X., Chu, H.-W., & Lin, S. (2020) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2020.3035578 · Cited by 50
ImpediBands: Body Coupled Bio-Impedance Patches for Physiological Sensing Proof of Concept
Sel, K., Ibrahim, B., & Jafari, R. (2020) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2020.2995810 · Cited by 33
Self-citationIn-office and out-of-office blood pressure measurement
Asayama, K., Ohkubo, T., & Imai, Y. (2021) · Journal of Human Hypertension · doi:10.1038/s41371-021-00486-8 · Cited by 32
Soleimani, E., Mokhtari‐Dizaji, M., Fatouraee, N., & Saberi, H. (2016) · ULTRASONOGRAPHY · doi:10.14366/usg.16019 · Cited by 27
Sel, K., Kireev, D., Brown, A., Ibrahim, B., Akinwande, D., & Jafari, R. (2019) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas.2019.8919003 · Cited by 24
Self-citationA Wrist-worn Respiration Monitoring Device using Bio-Impedance
Sel, K., Brown, A., Jang, H., Krumholz, H. M., Lu, N., & Jafari, R. (2020) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc44109.2020.9176367 · Cited by 19
Self-citationBlood Pressure Estimation using a Single Channel Bio-Impedance Ring Sensor
Osman, D., Jankovic, M., Sel, K., Pettigrew, R. I., & Jafari, R. (2022) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc48229.2022.9871653 · Cited by 13
Self-citationWearable ring bioelectrical impedance analyzer for estimation and monitoring of body fat
Usman, M., Gupta, A. K., & Xue, W. (2022) · Smart Health · doi:10.1016/j.smhl.2022.100275 · Cited by 7
Boosted-SpringDTW for Comprehensive Feature Extraction of PPG Signals
Martinez, J., Sel, K., Mortazavi, B. J., & Jafari, R. (2022) · IEEE Open Journal of Engineering in Medicine and Biology · doi:10.1109/ojemb.2022.3174806 · Cited by 7
Self-citationHow Much Energy Can We Harvest Daily for Wearable Applications?
Tuncel, Y., Başaklar, T., & Ogras, U. Y. (2021) · IEEE/ACM International Symposium on Low Power Electronics and Design (ISLPED) · doi:10.1109/islped52811.2021.9502507 · Cited by 6
Monte Carlo Modeling of a Photoplethysmographic (PPG) in Individuals with Obesity
Boonya-ananta, T., Rodriguez, A. J., Hansen, A. K., Hutcheson, J. D., & Ramella‐Roman, J. C. (2020) · Optics in the Life Sciences · doi:10.1364/translational.2020.jtu3a.39 · Cited by 4
Research works printed but not linked: 2
- Grimnes, S. & Martinsen, O. G. Bioimpedance and bioelectricity basics. (Academic press, 2011).
- Kireev, D. et al. Continuous cuffless monitoring of arterial blood pressure via graphene bioimpedance tattoos. Nat. Nanotechnol. 17, 864–870 (2022). · DOI
Cited by
Sorted by citations
Self-Powered Sensing in Wearable Electronics─A Paradigm Shift Technology
Tang, W., Sun, Q., & Wang, Z. L. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00305 · Cited by 332
Transforming Cardiovascular Care With Artificial Intelligence: From Discovery to Practice
Khera, R., Oikonomou, E. K., Nadkarni, G. N., Morley, J., Wiens, J., Butte, A. J., & Topol, E. J. (2024) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2024.05.003 · Cited by 324
A review on flexible wearables – Recent developments in non-invasive continuous health monitoring
Kazanskiy, N. L., Khonina, S. N., & Butt, M. A. (2024) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2023.114993 · Cited by 216
E-Tattoos: Toward Functional but Imperceptible Interfacing with Human Skin
Li, H., Tan, P., Rao, Y., Bhattacharya, S., Wang, Z., Kim, S., Gangopadhyay, S., Shi, H., Jankovic, M., Huh, H., et al. (2024) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00626 · Cited by 144
Sel, K., Hawkins-Daarud, A. J., Chaudhuri, A., Osman, D., Bahai, A. R. S., Paydarfar, D., Willcox, K. E., Chung, C., & Jafari, R. (2025) · npj Digital Medicine · doi:10.1038/s41746-025-01447-y · Cited by 148
Self-citation
Metadata
- Authors
- Sel, K., Osman, D., Huerta, N., Edgar, A., Pettigrew, R. I., & Jafari, R.
- Affiliations
- Texas A&M University (US)
- Corresponding author
- Jafari, Roozbeh
- Venue
- npj Digital Medicine
- Published
- 2023-03-30
- Volume
- 6
- Issue
- 1
- Pages
- 59-59
- ISSN
- 2398-6352 (ISSN-L)
- PMC
- PMC10063561
- OpenAlex
- W4361279210
- Cited by
- 100
- References
- 40
- Citations by year
- 2026: 23 · 2025: 41 · 2024: 25 · 2023: 11
- FWCI
- 7.88
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Locations
- npj Digital Medicine (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- U.S. Department of Health & Human Services | NIH | National Heart, Lung, and Blood Institute (1R01HL151240)
- U.S. Department of Health & Human Services | NIH | National Institute of Biomedical Imaging and Bioengineering (1R01EB028106)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrical and Bioimpedance Tomography
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
- Keywords
- cuffless blood pressure measurement, bioimpedance, smart rings, continuous blood pressure estimation, electrode placement optimization, cardiovascular monitoring
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review