CoChat

Real-time finger motion recognition using skin-conformable electronics

Open access
Cho, Haein, Lee, Inho, Jang, Jingon, Kim, Jae-Hyun, Lee, Hanbee, Park, Sungjun, Wang, Gunuk · 2023 · Nature Electronics

Published version of a preprint

The DOI matches its Crossref record; 56 of the 56 references it cites were found in a registry or an index.

Abstract

Interpreting and tracking finger motion in free space is of use in the development of control interfaces for augmented and virtual reality systems. One approach to create human–machine interfaces capable of accurate finger motion recognition is to use wearable sensors with integrated neuromorphic computing. Here we show that an integrated titanium-oxide-based artificial synapse array and organic motion sensor can be conformably attached to a finger and provide real-time motion recognition. The synaptic device and sensor exhibit well-defined synaptic and light-responsive electrical properties, respectively, as well as flexibility and mechanical robustness. The integrated synapses–sensor enables optical–electrical signal conversion and summation of post-synaptic current. Finger motions for time-resolved digit patterns (0–9) can be learned and recognized with an accuracy of up to 95% at varying strains and up to 100 strain cycles. An integrated artificial synapse array and light-responsive motion sensor can be conformably attached to a finger and used to track finger motion in three-dimensional space.

Overview

Integrity signals

Registry

Crossref · 10.1038/s41928-023-01012-z

Cites

56 of 56 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 56 references

Research works printed but not linked: 1

  1. Srivastava, N., Hinton, G., Krizhevsky, A., Sutskever, I. & Salakhutdinov, R. Dropout: a simple way to prevent neural networks from overfitting. J. Mach. Learn. Res. 15, 1929–1958 (2014).

Cited by

See all 88

Metadata

Authors
Cho, H., Lee, I., Jang, J., Kim, J.-H., Lee, H., Park, S., & Wang, G.
Affiliations
  • Korea University (KR)
  • Ajou University (KR)
Corresponding author
  • Park, Sungjun
  • Wang, Gunuk
Venue
Nature Electronics
Published
2023-08-10
Volume
6
Issue
8
Pages
619-629
ISSN
2520-1131 (ISSN-L)
OpenAlex
W4385737773
Cited by
87
References
56
Citations by year
2026: 19 · 2025: 36 · 2024: 29 · 2023: 3
FWCI
6.46
Type
journal article
Language
en
Open access
Licence
Locations
  • Nature Electronics (publishedVersion)
  • Research Square (acceptedVersion, cc-by)
Funders
  • National Research Foundation of Korea
  • Ministry of Education
  • Korea Electric Power Corporation
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced Memory and Neural Computing
  • Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Nanomaterials and Printing Technologies
Keywords
finger motion recognition, neuromorphic computing, artificial synapses, titanium oxide, wearable sensors, human-machine interaction, virtual reality control, strain sensing, digit recognition

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Real-time finger motion recognition using skin-conformable electronics. https://app.cochat.ai/papers/10.1038/s41928-023-01012-z
The paper
Cho, H., Lee, I., Jang, J., Kim, J.-H., Lee, H., Park, S., & Wang, G. (2023). Real-time finger motion recognition using skin-conformable electronics. Nature Electronics. https://doi.org/10.1038/s41928-023-01012-z

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.