Extraction and biomolecular analysis of dermal interstitial fluid collected with hollow microneedles
Open accessThe DOI matches its Crossref record; 42 of the 42 references it cites were found in a registry or an index.
Abstract
Dermal interstitial fluid (ISF) is an underutilized information-rich biofluid potentially useful in health status monitoring applications whose contents remain challenging to characterize. Here, we present a facile microneedle approach for dermal ISF extraction with minimal pain and no blistering for human subjects and rats. Extracted ISF volumes were sufficient for determining transcriptome, and proteome signatures. We noted similar profiles in ISF, serum, and plasma samples, suggesting that ISF can be a proxy for direct blood sampling. Dynamic changes in RNA-seq were recorded in ISF from induced hypoxia conditions. Finally, we report the first isolation and characterization, to our knowledge, of exosomes from dermal ISF. The ISF exosome concentration is 12–13 times more enriched when compared to plasma and serum and represents a previously unexplored biofluid for exosome isolation. This minimally invasive extraction approach can enable mechanistic studies of ISF and demonstrates the potential of ISF for real-time health monitoring applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
NIH Image to ImageJ: 25 years of image analysis
Schneider, C. A., Rasband, W. S., & Eliceiri, K. W. (2012) · Nature Methods · doi:10.1038/nmeth.2089 · Cited by 64,638
Fast gapped-read alignment with Bowtie 2
Langmead, B., & Salzberg, S. L. (2012) · Nature Methods · doi:10.1038/nmeth.1923 · Cited by 56,400
HTSeq—a Python framework to work with high-throughput sequencing data
Anders, S., Pyl, P. T., & Huber, W. (2015) · Bioinformatics · doi:10.1093/bioinformatics/btu638 · Cited by 21,464
DAVID: Database for Annotation, Visualization, and Integrated Discovery
Dennis, G., Sherman, B. T., Hosack, D. A., Yang, J., Gao, W., Lane, H. C., & Lempicki, R. A. (2003) · Genome Biology · doi:10.1186/gb-2003-4-5-p3 · Cited by 9,327
Adjusting batch effects in microarray expression data using empirical Bayes methods
Johnson, W. E., Li, C., & Rabinovic, A. (2007) · Biostatistics · doi:10.1093/biostatistics/kxj037 · Cited by 8,658
2016 update of the PRIDE database and its related tools
Vizcaíno, J. A., Csordas, A., del-Toro, N., Dianes, J. A., Griss, J., Lavidas, I., Mayer, G., Perez-Riverol, Y., Reisinger, F., Ternent, T., et al. (2016) · Nucleic Acids Research · doi:10.1093/nar/gkv1145 · Cited by 3,451
Semi-supervised learning for peptide identification from shotgun proteomics datasets
Käll, L., Canterbury, J. D., Weston, J., Noble, W. S., & MacCoss, M. J. (2007) · Nature Methods · doi:10.1038/nmeth1113 · Cited by 2,424
Witwer, K. W., Buzás, E. I., Bemis, L. T., Bora, A., Lässer, C., Lötvall, J., Nolte‐‘t Hoen, E. N., Piper, M. G., Sivaraman, S., Skog, J., et al. (2013) · Journal of Extracellular Vesicles · doi:10.3402/jev.v2i0.20360 · Cited by 2,421
Orthogonality of Separation in Two-Dimensional Liquid Chromatography
Gilar, M., Olivova, P., Daly, A. E., & Gebler, J. C. (2005) · Analytical Chemistry · doi:10.1021/ac050923i · Cited by 816
Baranyai, T., Herczeg, K., Onódi, Z., Voszka, I., Módos, K., Marton, N., Nagy, G., Mäger, I., Wood, M. J., El Andaloussi, S., et al. (2015) · PLOS ONE · doi:10.1371/journal.pone.0145686 · Cited by 670
Cited by
Accessing analytes in biofluids for peripheral biochemical monitoring
Heikenfeld, J., Jajack, A., Feldman, B., Granger, S. W., Gaitonde, S., Begtrup, G., & Katchman, B. A. (2019) · Nature Biotechnology · doi:10.1038/s41587-019-0040-3 · Cited by 758
Hydrogel‐Forming Microneedles: Current Advancements and Future Trends
Turner, J. G., White, L. R., Estrela, P., & Leese, H. S. (2021) · Macromolecular Bioscience · doi:10.1002/mabi.202000307 · Cited by 413
Sampling interstitial fluid from human skin using a microneedle patch
Samant, P. P., Niedzwiecki, M. M., Raviele, N., Tran, V., Mena-Lapaix, J., Walker, D. I., Felner, E. I., Jones, D. P., Miller, G. W., & Prausnitz, M. R. (2020) · Science Translational Medicine · doi:10.1126/scitranslmed.aaw0285 · Cited by 379
Opportunities and challenges in the diagnostic utility of dermal interstitial fluid
Friedel, M., Thompson, I. A. P., Kasting, G., Polsky, R., Cunningham, D., Soh, H. T., & Heikenfeld, J. (2023) · Nature Biomedical Engineering · doi:10.1038/s41551-022-00998-9 · Cited by 360
Self-citationFrom Diagnosis to Treatment: Recent Advances in Patient-Friendly Biosensors and Implantable Devices
Li, P., Lee, G.-H., Kim, S. Y., Kwon, S. Y., Kim, H.-R., & Park, S. (2021) · ACS Nano · doi:10.1021/acsnano.0c06688 · Cited by 359
Goud, K. Y., Moonla, C., Mishra, R. K., Yu, C., Narayan, R., Litvan, I., & Wang, J. (2019) · ACS Sensors · doi:10.1021/acssensors.9b01127 · Cited by 354
Lab under the Skin: Microneedle Based Wearable Devices
Teymourian, H., Tehrani, F., Mahato, K., & Wang, J. (2021) · Advanced Healthcare Materials · doi:10.1002/adhm.202002255 · Cited by 310
Hollow microneedles: A perspective in biomedical applications
Cárcamo-Martínez, Á., Mallon, B., Domínguez-Robles, J., Vora, L. K., Anjani, Q. K., & Donnelly, R. F. (2021) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2021.120455 · Cited by 285
A Hydrogel Microneedle Patch for Point‐of‐Care Testing Based on Skin Interstitial Fluid
He, R., Niu, Y., Li, Z., Li, A., Yang, H., Xu, F., & Li, F. (2020) · Advanced Healthcare Materials · doi:10.1002/adhm.201901201 · Cited by 257
Microneedle biomedical devices
Zheng, M., Sheng, T., Yu, J., Gu, Z., & Xu, C. (2023) · Nature Reviews Bioengineering · doi:10.1038/s44222-023-00141-6 · Cited by 235
“The second is using hollow 83 , porous 84–86 and grooved solid MNs 87 to generate a capillary effect for ISF extraction.”
Al Sulaiman, D., Chang, J. Y. H., Bennett, N. R., Topouzi, H., Higgins, C. A., Irvine, D. J., & Ladame, S. (2019) · ACS Nano · doi:10.1021/acsnano.9b04783 · Cited by 233
3D-printed microneedles in biomedical applications
Dabbagh, S. R., Sarabi, M. R., Rahbarghazi, R., Sokullu, E., Yetisen, A. K., & Tasoglu, S. (2021) · iScience · doi:10.1016/j.isci.2020.102012 · Cited by 231
Microneedles for transdermal diagnostics: Recent advances and new horizons
Liu, G.-S., Kong, Y., Wang, Y., Luo, Y., Fan, X., Xie, X., Yang, B.-R., & Wu, M. X. (2020) · Biomaterials · doi:10.1016/j.biomaterials.2019.119740 · Cited by 231
“Analyte Sensor structure Detection method Test subject Detection site Ref Glucose Hydrogel SMNs Glucose assay kit Mouse Off device [34] Metal HMN + Paper sensor Colorimetry Rabbit On device [89] Si HMNs + Sensor Electrochemistry Human On device [40] Metal SMNs + PEDOT Electrochemistry –”
BackgroundInfluentialMicroneedle Aptamer-Based Sensors for Continuous, Real-Time Therapeutic Drug Monitoring
Wu, Y., Tehrani, F., Teymourian, H., Mack, J., Shaver, A., Reynoso, M., Kavner, J., Huang, N., Furmidge, A., Duvvuri, A., et al. (2022) · Analytical Chemistry · doi:10.1021/acs.analchem.2c00829 · Cited by 212
Skin in the diagnostics game: Wearable biosensor nano- and microsystems for medical diagnostics
Dervisevic, M., Alba, M., Prieto-Simon, B., & Voelcker, N. H. (2020) · Nano Today · doi:10.1016/j.nantod.2019.100828 · Cited by 203
Microneedle system for tissue engineering and regenerative medicine
Zhang, Y., Xu, Y., Kong, H., Zhang, J., Chan, H. F., Wang, J., Shao, D., Tao, Y., & Li, M. (2023) · Exploration · doi:10.1002/exp.20210170 · Cited by 200
Vora, L. K., Sabri, A. H., McKenna, P. E., Himawan, A., Hutton, A. R. J., Detamornrat, U., Paredes, A. J., Larrañeta, E., & Donnelly, R. F. (2023) · Nature Reviews Bioengineering · doi:10.1038/s44222-023-00108-7 · Cited by 193
Biomarkers and Detection Platforms for Human Health and Performance Monitoring: A Review
Sim, D., Brothers, M. C., Slocik, J. M., Islam, A. E., Maruyama, B., Grigsby, C. C., Naik, R. R., & Kim, S. S. (2022) · Advanced Science · doi:10.1002/advs.202104426 · Cited by 186
A practical guide to the development of microneedle systems – In clinical trials or on the market
Lee, K. J., Jeong, S. S., Roh, D. H., Kim, D. Y., Choi, H.-K., & Lee, E. H. (2020) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2019.118778 · Cited by 173
Biosensing in dermal interstitial fluid using microneedle based electrochemical devices
Madden, J., O'Mahony, C., Thompson, M., O'Riordan, A., & Galvin, P. (2020) · Sensing and Bio-Sensing Research · doi:10.1016/j.sbsr.2020.100348 · Cited by 161
A microneedle device for rapid dermal interstitial fluid sampling
Hung, A. H., Kamat, N. U., Bermudez, A., Boczek, S. M., Garcia-Marqués, F. J., Tan, Y. L., Hwang, J. (., Sinawang, P. D., Ilyin, D., Jacobson, G. B., et al. (2025) · Science Advances · doi:10.1126/sciadv.adx5492 · Cited by 22
A Microneedle Device for Rapid Dermal Interstitial Fluid Sampling
Hung, A. H., Rajesh, N. U., Bermudez, A., Boczek, S. M., Garcia-Marqués, F. J., Tan, Y. L., Hwang, J. (., Sinawang, P. D., Ilyin, D., Jacobson, G. B., et al. (2025) · doi:10.1101/2025.03.13.641882 · Cited by 22
Metadata
- Authors
- Miller, P. R., Taylor, R. M., Tran, B. Q., Boyd, G., Glaros, T., Chavez, V. H., Krishnakumar, R., Sinha, A., Poorey, K., Williams, K. P., Branda, S. S., Baca, J. T., & Polsky, R.
- Venue
- Communications Biology
- Published
- 2018-10-22
- Volume
- 1
- Issue
- 1
- Pages
- 173-173
- ISSN
- 2399-3642 (ISSN-L)
- OpenAlex
- W2896348701
- Cited by
- 258
- References
- 42
- FWCI
- 4.47
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.