Implantable FES system for upright mobility and bladder and bowel function for individuals with spinal cord injury
The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Abstract
Study design Postintervention. Objectives To determine the effectiveness of the Praxis multifunctional implantable functional electrical stimulation (FES) system (Neopraxis Pty. Ltd, Lane Cove, NSW, Australia) to provide standing and stepping ability and bladder and bowel management for individuals with motor complete thoracic level spinal cord injuries (SCI). Setting Pediatric orthopedic hospital specializing in SCI. Subjects Three males, ages 17 and 21 years, with motor-complete thoracic level SCI and intact lower motor neurons to the muscles targeted for stimulation. Methods Each subject was successfully implanted with the Praxis FES system. All three subjects received electrodes for upright mobility and the first two subjects received additional electrodes for stimulated bladder and bowel management. Following training, subjects were evaluated in their ability to use FES for nine mobility activities. Acute and chronic experiments of the effect of stimulation on bowel and bladder function were also performed. Results All three subjects could independently stand up from the wheelchair and could walk at least 6 m using a swing through gait pattern. Two subjects were able to independently perform swing through gait for 6 min and one subject was able to independently ascend and descend stairs. Suppression of reflex bladder contractions by neuromodulation (subject 1) and stimulated contractions of the rectum (subject 2) were observed in acute experiments. When stimulation was a…
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“PDMS is now the material of choice for most nerve cuffs in clinical practice, including those for vagus nerve (Ben-Menachem et al., 2015) and sacral nerve stimulation (Brindley et al., 1982; Johnston et al., 2005).”
From Foreign Body Reaction to Implanted Biomaterials and Its Impact in Nerve Neuroprosthetics (2021) · cites this paper as Johnston et al., 2005
Citations
Cites
BONE MINERAL DENSITY AND INDEXES OF BONE METABOLISM IN SPINAL CORD INJURY
Szollar, S. M., Martin, E. M. E., Sartoris, D. J., Parthemore, J. G., & Deftos, L. J. (1998) · American Journal of Physical Medicine & Rehabilitation · doi:10.1097/00002060-199801000-00005 · Cited by 174
Synthesis of paraplegic gait with multichannel functional neuromuscular stimulation
Kobetic, R., & Marsolais, E. B. (1994) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.313148 · Cited by 165
Creasey, G. H., Grill, J. H., Korsten, M. A., Hoi Sang, U., Betz, R., Anderson, R. U., & Walter, J. W. (2001) · Archives of Physical Medicine and Rehabilitation · doi:10.1053/apmr.2001.25911 · Cited by 154
Self-citationThe acute effects of continuous and conditional neuromodulation on the bladder in spinal cord injury
Kirkham, A. P. S., Shah, N., Knight, S. L., Shah, P. J. R., & Craggs, M. D. (2001) · Spinal Cord · doi:10.1038/sj.sc.3101177 · Cited by 148
Jones, L. M., Goulding, A., & GERRARD, D. F. (1998) · Spinal Cord · doi:10.1038/sj.sc.3100664 · Cited by 120
Binnie, N. R., Smith, A. N., Creasey, G. H., & Edmond, P. (1991) · Spinal Cord · doi:10.1038/sc.1991.63 · Cited by 94
Self-citationKirkham, A. P. S., Knight, S. L., Craggs, M. D., Casey, A. T. H., & Shah, P. J. R. (2002) · Spinal Cord · doi:10.1038/sj.sc.3101278 · Cited by 85
Implantable selective stimulator to improve bladder voiding: design and chronic experiments in dogs
Boyer, S., Sawan, M., Abdel-Gawad, M., Robin, S., & Elhilali, M. M. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.895949 · Cited by 77
Demineralization in tetraplegic and paraplegic man over time
Szollar, S. M., Martin, E. M. E., Parthemore, J. G., Sartoris, D. J., & Deftos, L. J. (1997) · Spinal Cord · doi:10.1038/sj.sc.3100401 · Cited by 66
Densitometric patterns of spinal cord injury associated bone loss
Szollar, S. M., Martin, E. M. E., Parthemore, J. G., Sartoris, D. J., & Deftos, L. J. (1997) · Spinal Cord · doi:10.1038/sj.sc.3100394 · Cited by 59
Kagaya, H., Shimada, Y., Ebata, K., Sato, M., Satô, K., YUKAWA, T., & Obinata, G. (1995) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/s0003-9993(95)80556-7 · Cited by 56
Functional Electrical Stimulation For Walking In Paraplegia: 17-Year Follow-Up Of 2 Cases
Agarwal, S., Kobetic, R., Nandurkar, S., & Marsolais, E. B. (2003) · The Journal of Spinal Cord Medicine · doi:10.1080/10790268.2003.11753666 · Cited by 49
Johnston, T., Betz, R., Smith, B. T., & Mulcahey, M. J. (2003) · Spinal Cord · doi:10.1038/sj.sc.3101392 · Cited by 47
Self-citationUhlir, J. P., Triolo, R. J., Davis, J. A., & Bieri, C. (2004) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2004.827224 · Cited by 44
Previnaire, J.-G., Soler, J. M., & Perrigot, M. (1998) · Spinal Cord · doi:10.1038/sj.sc.3100440 · Cited by 43
Selective suppression of sphincter activation during sacral anterior nerve root stimulation
Bhadra, N., Grünewald, V., Creasey, G., & Mortimer, J. T. (2002) · Neurourology and Urodynamics · doi:10.1002/nau.2068 · Cited by 40
Self-citationDavis, R., Houdayer, T., Andrews, B., & Barriskill, A. (1999) · Artificial Organs · doi:10.1046/j.1525-1594.1999.06368.x · Cited by 37
Self-citationEffects of functional electrical stimulation on the joints of adolescents with spinal cord injury
Betz, R., Boden, B. P., Triolo, R. J., Mesgarzadeh, M., Gardner, E., & Fife, R. S. (1996) · Spinal Cord · doi:10.1038/sc.1996.25 · Cited by 28
Self-citationDevelopment of functional electrical stimulators utilizing cochlear implant technology
Davis, R., Patrick, J. F., & Barriskill, A. (2001) · Medical Engineering & Physics · doi:10.1016/s1350-4533(01)00023-6 · Cited by 26
Self-citationInter-rater Reliability of a Clinical Test of Standing Function
Triolo, R. J., Bevelheimer, T., Eisenhower, G., & Wormser, D. (1995) · The Journal of Spinal Cord Medicine · doi:10.1080/10790268.1995.11719375 · Cited by 23
Percutaneous Implantation of Iliopsoas for Functional Neuromuscular Stimulation
Nandurkar, S., Marsolais, E. B., & Kobetic, R. (2001) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-200108000-00030 · Cited by 15
Cited by
Foreign Body Reaction to Implanted Biomaterials and Its Impact in Nerve Neuroprosthetics
Carnicer-Lombarte, A., Chen, S.-T., Malliaras, G. G., & Barone, D. G. (2021) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2021.622524 · Cited by 454
“These include sacral nerve stimulation to restore bladder and bowel function (Brindley et al., 1982; Johnston et al., 2005) and peroneal nerve stimulation for the treatment of foot drop (Liberson et al.”
BackgroundNeurogenic bowel management after spinal cord injury: a systematic review of the evidence
the SCIRE Research Team, Krassioukov, A., Eng, J. J., Claxton, G., Sakakibara, B. M., & Shum, S. (2010) · Spinal Cord · doi:10.1038/sc.2010.14 · Cited by 226
Functional electrical stimulation of walking: Function, exercise and rehabilitation
Thrasher, T. A., & Popović, M. R. (2008) · Annales de Réadaptation et de Médecine Physique · doi:10.1016/j.annrmp.2008.05.006 · Cited by 130
Kesar, T. M., & Binder‐Macleod, S. A. (2006) · Experimental Physiology · doi:10.1113/expphysiol.2006.033886 · Cited by 128
Functional Electrical Stimulation in Spinal Cord Injury: From Theory to Practice
Martin, R. A., Sadowsky, C. L., Obst, K., Meyer, B., & McDonald, J. W. (2012) · Topics in Spinal Cord Injury Rehabilitation · doi:10.1310/sci1801-28 · Cited by 120
Metadata
- Authors
- Johnston, T. E., Betz, R. R., Smith, B. T., Benda, B. J., Mulcahey, M. J., Davis, R., Houdayer, T. P., Pontari, M. A., Barriskill, A., & Creasey, G. H.
- Affiliations
- Shriners Hospitals for Children - Philadelphia (US)
- Temple University Hospital (US)
- Baltimore Museum of Art (US)
- Case Western Reserve University (US)
- Venue
- Spinal Cord
- Published
- 2005-07-05
- Volume
- 43
- Issue
- 12
- Pages
- 713-723
- ISSN
- 1362-4393 (ISSN-L)
- 1476-5624
- OpenAlex
- W2017877008
- Cited by
- 60
- References
- 21
- Citations by year
- 2025: 1 · 2023: 3 · 2022: 3 · 2021: 3 · 2020: 4 · 2019: 3 · 2018: 4 · 2016: 5 · 2015: 1 · 2014: 3 · 2012: 5
- FWCI
- 1.11
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Spinal Cord (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Shriners Hospitals for Children
- Topics
- Health Sciences › Medicine › Clinical Neurology › Spinal Cord Injury Research
- Health Sciences › Medicine › Rehabilitation › Stroke Rehabilitation and Recovery
- Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
- Keywords
- spinal cord injury, thoracic spinal cord injury, bladder management, bowel function, neuromodulation, motor complete injury, adolescents and young adults
- MeSH terms
- Adolescent, Adult, Urinary Bladder, Neurogenic, Electric Stimulation Therapy, Fecal Incontinence, Humans, Male, Spinal Cord Injuries, Thoracic Vertebrae, Treatment Outcome, Equipment Failure Analysis, Recovery of Function, Gait Disorders, Neurologic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.