CoChat

Implantable selective stimulator to improve bladder voiding: design and chronic experiments in dogs

Boyer, S., Sawan, M., Abdel-Gawad, M., Robin, S., Elhilali, M.M. · 2000 · IEEE Transactions on Rehabilitation Engineering
Cited by 77

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Among the treatments to enhance the bladder voiding, the sacral roots neurostimulation is one of the most promising techniques. The electrostimulation of sacral nerves provokes a simultaneous contraction of the detrusor muscle as well as the external urethral sphincter (EUS). A new simplified-architecture implantable stimulator with its wireless controller have been designed to investigate high-frequency inhibition stimulation strategies. This innovative technique based on high-frequency inhibition reduces sphincter activity during stimulation. Low-frequency current pulses also applied to the sacral roots induces contraction of the detrusor muscle resulting in low pressure voiding. Chronic experiments were carried out on ten male mongrel paraplegic dogs. One cuff electrode was implanted along with each stimulator for eight months. The animals were stimulated twice a day using the prototypes of our implantable selective stimulator while voided and residual urine volume were measured during the procedure. These experiments revealed that the proposed stimulation strategy enhances bladder voiding by more than 50% in comparison with low-frequency only stimulation. The residual urine volume was reduced to an average of 9% and low pressure micturition was achieved as shown by weekly cystourethrogram.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/86.895949

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 77

Metadata

Authors
Boyer, S., Sawan, M., Abdel-Gawad, M., Robin, S., & Elhilali, M. M.
Venue
IEEE Transactions on Rehabilitation Engineering
Published
2000
Volume
8
Issue
4
Pages
464-470
ISSN
1063-6528 (ISSN-L)
OpenAlex
W2156021100
Cited by
77
References
3
FWCI
2.89
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Implantable selective stimulator to improve bladder voiding: design and chronic experiments in dogs. https://app.cochat.ai/papers/10.1109/86.895949
The paper
Boyer, S., Sawan, M., Abdel-Gawad, M., Robin, S., & Elhilali, M. M. (2000). Implantable selective stimulator to improve bladder voiding: design and chronic experiments in dogs. IEEE Transactions on Rehabilitation Engineering. https://doi.org/10.1109/86.895949

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.