Neuromodulation accompanying focused ultrasound-induced blood-brain barrier opening
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Burst-mode focused ultrasound (FUS) induces microbubble cavitation in the vasculature and temporarily disrupts the blood-brain barrier (BBB) to enable therapeutic agent delivery. However, it remains unclear whether FUS-induced BBB opening is accompanied by neuromodulation. Here we characterized the functional effects of FUS-induced BBB opening by measuring changes in somatosensory evoked potentials (SSEPs) and blood-oxygen-level dependent (BOLD) responses. Rats underwent burst-mode FUS (mechanical index (MI) of 0.3, 0.55 or 0.8) to the forelimb region in the left primary somatosensory cortex to induce BBB opening. Longitudinal measurements were followed for up to 1 week to characterize the temporal dynamics of neuromodulation. We observed that 0.8-MI FUS profoundly suppressed SSEP amplitude and prolonged latency and this effect lasted 7 days. 0.55-MI FUS resulted in minimal and short-term suppression of SSEP for less than 60 minutes and didn’t affect latency. BOLD responses were also suppressed in an MI-dependent manner, mirroring the effect on SSEPs. Furthermore, repetitive delivery of 0.55-MI FUS every 3 days elicited no accumulative effects on SSEPs or tissue integrity. This is the first evidence that FUS-induced BBB opening is accompanied by reversible changes in neuron responses and may provide valuable insight toward the development of FUS-induced BBB opening for clinical applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Transcranial direct current stimulation: State of the art 2008
Nitsche, M. A., Cohen, L. G., Wassermann, E. M., Priori, A., Lang, N., Antal, A., Paulus, W., Hummel, F., Boggio, P. S., Fregni, F., et al. (2008) · Brain Stimulation · doi:10.1016/j.brs.2008.06.004 · Cited by 3,057
Dynamics of blood flow and oxygenation changes during brain activation: the Balloon model
Buxton, R. B., Wong, E. C., & Frank, L. R. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910390602 · Cited by 1,665
Nitsche, M. A., Schauenburg, A., Lang, N., Liebetanz, D., Exner, C., Paulus, W., & Tergau, F. (2003) · Journal of Cognitive Neuroscience · doi:10.1162/089892903321662994 · Cited by 1,032
Repetitive transcranial magnetic stimulation or transcranial direct current stimulation?
Priori, A., Hallett, M., & Rothwell, J. C. (2009) · Brain Stimulation · doi:10.1016/j.brs.2009.02.004 · Cited by 282
Liu, H., Hsu, P., Chu, P., Wai, Y., Chen, J., Shen, C., Yen, T., & Wang, J. (2009) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21599 · Cited by 54
Self-citation
Cited by
Ultrasound Neuromodulation: A Review of Results, Mechanisms and Safety
Blackmore, J., Shrivastava, S., Sallet, J., Butler, C. R., & Cleveland, R. O. (2019) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2018.12.015 · Cited by 556
Wireless and battery-free technologies for neuroengineering
Won, S. M., Cai, L., Gutruf, P., & Rogers, J. A. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00683-3 · Cited by 360
Advanced optoacoustic methods for multiscale imaging of in vivo dynamics
Deán-Ben, X. L., Gottschalk, S., Mc Larney, B., Shoham, S., & Razansky, D. (2017) · Chemical Society Reviews · doi:10.1039/c6cs00765a · Cited by 337
Ultrasonic Neuromodulation Causes Widespread Cortical Activation via an Indirect Auditory Mechanism
Sato, T., Shapiro, M. G., & Tsao, D. Y. (2018) · Neuron · doi:10.1016/j.neuron.2018.05.009 · Cited by 329
Magnetic iron oxide nanoparticles for brain imaging and drug delivery
Qiao, R., Fu, C., Forgham, H., Javed, I., Huang, X., Zhu, J., Whittaker, A. K., & Davis, T. P. (2023) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2023.114822 · Cited by 245
Focused ultrasound for neuromodulation
Darrow, D. P. (2019) · Neurotherapeutics · doi:10.1007/s13311-018-00691-3 · Cited by 190
A review of low-intensity focused ultrasound for neuromodulation
Baek, H., Pahk, K. J., & Kim, H. (2017) · Biomedical Engineering Letters · doi:10.1007/s13534-016-0007-y · Cited by 184
Park, J., Aryal, M., Vykhodtseva, N., Zhang, Y.-Z., & McDannold, N. (2017) · Journal of Controlled Release · doi:10.1016/j.jconrel.2016.10.011 · Cited by 162
“These studies suggest that MRI contrast agents can predict drug or tracer concentrations in the normal brain, even when large drug carriers (liposomes) are used [11, 22,25,26].”
Applications of focused ultrasound-mediated blood-brain barrier opening
Gorick, C. M., Breza, V. R., Nowak, K. M., Cheng, V. W. T., Fisher, D. G., Debski, A. C., Hoch, M. R., Demir, Z. E. F., Tran, N. M., Schwartz, M. R., et al. (2022) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2022.114583 · Cited by 144
Ozdas, M. S., Shah, A. S., Johnson, P. M., Patel, N., Marks, M., Yasar, T. B., Stalder, U., Bigler, L., von der Behrens, W., Sirsi, S. R., et al. (2020) · Nature Communications · doi:10.1038/s41467-020-18059-7 · Cited by 63
Metadata
- Authors
- Chu, P.-C., Liu, H.-L., Lai, H.-Y., Lin, C.-Y., Tsai, H.-C., & Pei, Y.-C.
- Venue
- Scientific Reports
- Published
- 2015-10-22
- Volume
- 5
- Issue
- 1
- Pages
- 15477-15477
- ISSN
- 2045-2322 (ISSN-L)
- OpenAlex
- W2417435166
- Cited by
- 127
- References
- 5
- FWCI
- 5.35
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.