Engineering a 3D microfluidic culture platform for tumor-treating field application
Open accessThe DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
The limitations of current cancer therapies highlight the urgent need for a more effective therapeutic strategy. One promising approach uses an alternating electric field; however, the mechanisms involved in the disruption of the cancer cell cycle as well as the potential adverse effects on non-cancerous cells must be clarified. In this study, we present a novel microfluidic device with embedded electrodes that enables the application of an alternating electric field therapy to cancer cells in a 3D extracellular matrix. To demonstrate the potential of our system to aid in designing and testing new therapeutic approaches, cancer cells and cancer cell aggregates were cultured individually or co-cultured with endothelial cells. The metastatic potential of the cancer cells was reduced after electric field treatment. Moreover, the proliferation rate of the treated cancer cells was lower compared with that of the untreated cells, whereas the morphologies and proliferative capacities of the endothelial cells were not significantly affected. These results demonstrate that our novel system can be used to rapidly screen the effect of an alternating electric field on cancer and normal cells within an in vivo-like microenvironment with the potential to optimize treatment protocols and evaluate synergies between tumor-treating field treatment and chemotherapy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The present and future role of microfluidics in biomedical research
Sackmann, E. K., Fulton, A. L., & Beebe, D. J. (2014) · Nature · doi:10.1038/nature13118 · Cited by 2,995
Alternating electric fields arrest cell proliferation in animal tumor models and human brain tumors
Kirson, E. D., Dbalý, V., Tovaryš, F., Vymazal, J., Soustiel, J. F., Itzhaki, A., Mordechovich, D., Steinberg-Shapira, S., Gurvich, Z., Schneiderman, R., et al. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0702916104 · Cited by 894
Disruption of cancer cell replication by alternating electric fields
Kirson, E. D., Gurvich, Z., Schneiderman, R., Dekel, E., Itzhaki, A., Wasserman, Y., Schatzberger, R., & Palti, Y. (2004) · Cancer research · doi:10.1158/0008-5472.can-04-0083 · Cited by 827
Microfluidic assay for simultaneous culture of multiple cell types on surfaces or within hydrogels
Shin, Y., Han, S., Jeon, J. S., Yamamoto, K., Zervantonakis, I. K., Sudo, R., Kamm, R. D., & Chung, S. (2012) · Nature Protocols · doi:10.1038/nprot.2012.051 · Cited by 617
Self-citationDudley, A. C. (2012) · Cold Spring Harbor Perspectives in Medicine · doi:10.1101/cshperspect.a006536 · Cited by 424
Tumor treating fields: A new frontier in cancer therapy
Davies, A. M., Weinberg, U., & Palti, Y. (2013) · Annals of the New York Academy of Sciences · doi:10.1111/nyas.12112 · Cited by 193
Bai, J., Adriani, G., Dang, T.-M., Tu, T.-Y., Leong Penny, H.-X., Wong, S.-C., Kamm, R. D., & Thiery, J.-P. (2015) · Oncotarget · doi:10.18632/oncotarget.4716 · Cited by 110
Self-citationTumor treating fields: concept, evidence and future
Pless, M., & Weinberg, U. (2011) · Expert Opinion on Investigational Drugs · doi:10.1517/13543784.2011.583236 · Cited by 78
Cited by
Modelling cancer in microfluidic human organs-on-chips
Sontheimer-Phelps, A., Hassell, B. A., & Ingber, D. E. (2019) · Nature Reviews Cancer · doi:10.1038/s41568-018-0104-6 · Cited by 906
PDMS with designer functionalities—Properties, modifications strategies, and applications
Wolf, M. P., Salieb-Beugelaar, G. B., & Hunziker, P. (2018) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2018.06.001 · Cited by 853
Adriani, G., Ma, D., Pavesi, A., Kamm, R. D., & Goh, E. L. K. (2017) · Lab on a Chip · doi:10.1039/c6lc00638h · Cited by 443
Self-citationTumor-Treating Fields: A Fourth Modality in Cancer Treatment
Mun, E. J., Babiker, H. M., Weinberg, U., Kirson, E. D., & Von Hoff, D. D. (2018) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-17-1117 · Cited by 380
Applications of tumor chip technology
Hachey, S. J., & Hughes, C. C. W. (2018) · Lab on a Chip · doi:10.1039/c8lc00330k · Cited by 128
Characterizing the role of monocytes in T cell cancer immunotherapy using a 3d microfluidic model
Lee, S. W. L., Adriani, G., Ceccarello, E., Pavesi, A., Tan, A. T., Bertoletti, A., Kamm, R. D., & Wong, S. C. (2018) · Frontiers in Immunology · doi:10.3389/fimmu.2018.00416 · Cited by 109
Self-citationRodenhizer, D., Dean, T., D'Arcangelo, E., & McGuigan, A. P. (2018) · Advanced Healthcare Materials · doi:10.1002/adhm.201701174 · Cited by 80
A microfluidic platform for drug screening in a 3D cancer microenvironment
Pandya, H. J., Dhingra, K., Prabhakar, D., Chandrasekar, V., Natarajan, S. K., Vasan, A. S., Kulkarni, A., & Shafiee, H. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2017.03.054 · Cited by 76
Ozkan, A., Ghousifam, N., Hoopes, P. J., Yankeelov, T. E., & Rylander, M. N. (2019) · Biotechnology and Bioengineering · doi:10.1002/bit.26919 · Cited by 73
Fibroblast-associated tumour microenvironment induces vascular structure-networked tumouroid
Lee, S. W., Kwak, H. S., Kang, M.-H., Park, Y.-Y., & Jeong, G. S. (2018) · Scientific Reports · doi:10.1038/s41598-018-20886-0 · Cited by 68
Bridging the gap between tumor-on-chip and clinics: a systematic review of 15 years of studies
Bouquerel, C., Dubrova, A., Hofer, I., Phan, D. T. T., Bernheim, M., Ladaigue, S., Cavaniol, C., Maddalo, D., Cabel, L., Mechta-Grigoriou, F., et al. (2023) · Lab on a Chip · doi:10.1039/d3lc00531c · Cited by 58
Progress in melanoma modelling in vitro
Marconi, A., Quadri, M., Saltari, A., & Pincelli, C. (2018) · Experimental Dermatology · doi:10.1111/exd.13670 · Cited by 51
Mimicking Embedded Vasculature Structure for 3D Cancer on a Chip Approaches through Micromilling
Wan, L., Skoko, J., Yu, J., Ozdoganlar, O. B., LeDuc, P. R., & Neumann, C. A. (2017) · Scientific Reports · doi:10.1038/s41598-017-16458-3 · Cited by 38
Porat, Y., Giladi, M., Schneiderman, R. S., Blat, R., Shteingauz, A., Zeevi, E., Munster, M., Voloshin, T., Kaynan, N., Tal, O., et al. (2017) · Journal of Visualized Experiments · doi:10.3791/55820-v · Cited by 25
Metadata
- Authors
- Pavesi, A., Adriani, G., Tay, A., Warkiani, M. E., Yeap, W. H., Wong, S. C., & Kamm, R. D.
- Venue
- Scientific Reports
- Published
- 2016-05-24
- Volume
- 6
- Issue
- 1
- Pages
- 26584-26584
- ISSN
- 2045-2322 (ISSN-L)
- OpenAlex
- W2407836966
- Cited by
- 84
- References
- 8
- FWCI
- 7.30
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.