CoChat

Flexible Neural Electrode Array Based-on Porous Graphene for Cortical Microstimulation and Sensing

Open access

The DOI matches its Crossref record; 46 of the 47 references it cites were found in a registry or an index.

Abstract

Neural sensing and stimulation have been the backbone of neuroscience research, brain-machine interfaces and clinical neuromodulation therapies for decades. To-date, most of the neural stimulation systems have relied on sharp metal microelectrodes with poor electrochemical properties that induce extensive damage to the tissue and significantly degrade the long-term stability of implantable systems. Here, we demonstrate a flexible cortical microelectrode array based on porous graphene, which is capable of efficient electrophysiological sensing and stimulation from the brain surface, without penetrating into the tissue. Porous graphene electrodes show superior impedance and charge injection characteristics making them ideal for high efficiency cortical sensing and stimulation. They exhibit no physical delamination or degradation even after 1 million biphasic stimulation cycles, confirming high endurance. In in vivo experiments with rodents, same array is used to sense brain activity patterns with high spatio-temporal resolution and to control leg muscles with high-precision electrical stimulation from the cortical surface. Flexible porous graphene array offers a minimally invasive but high efficiency neuromodulation scheme with potential applications in cortical mapping, brain-computer interfaces, treatment of neurological disorders, where high resolution and simultaneous recording and stimulation of neural activity are crucial.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/srep33526

Cites

46 of 46 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1 Porous graphene electrode array fabrication. Schematics illustrating (a) laser pyrolysis, (b) metal interconnects and (c) SU-8 encapsulation. (d) Photograph of a fabricated 64-electrode array. (e) Tilt SEM image of a 64-spot porous graphene array. Scale bar: 1mm. The inset is the SEM image of an individual spot. Scale bar: 100 μm. (f) Impedance of all 64 electrodes at 1 kHz.
Figure 1 Porous graphene electrode array fabrication. Schematics illustrating (a) laser pyrolysis, (b) metal interconnects and (c) SU-8 encapsulation. (d) Photograph of a fabricated 64-electrode array. (e) Tilt SEM image of a 64-spot porous graphene array. Scale bar: 1mm. The inset is the SEM image of an individual spot. Scale bar: 100 μm. (f) Impedance of all 64 electrodes at 1 kHz.CC BY · PubMed Central
Figure 2 3D porous graphene fabricated by direct laser pyrolysis method. (a) Raman spectra of porous graphene samples at different power levels, with ID/IG ratio for each sample shown in (b). (c) SEM image of the porous morphology of surface. Scale bar: 2 μm. (d) SEM image of the cross-section view of porous graphene. Scale bar:100 μm.
Figure 2 3D porous graphene fabricated by direct laser pyrolysis method. (a) Raman spectra of porous graphene samples at different power levels, with ID/IG ratio for each sample shown in (b). (c) SEM image of the porous morphology of surface. Scale bar: 2 μm. (d) SEM image of the cross-section view of porous graphene. Scale bar:100 μm.CC BY · PubMed Central
Figure 3 Electrochemical characterization. (a) Electrochemical Impedance Spectroscopy (EIS) comparison among doped and undoped porous graphene and Au electrodes. (b) CV characterization of porous graphene and Au electrodes. Measurement of the charge injection limit with cathodal-first symmetric biphasic current pulses for the porous graphene electrode (c) before and (d) after doping. (e) Cycling with biphasic stimulation pulses to study degradation during charge injection. (f) EIS before and after 1 million stimulation cycles.
Figure 3 Electrochemical characterization. (a) Electrochemical Impedance Spectroscopy (EIS) comparison among doped and undoped porous graphene and Au electrodes. (b) CV characterization of porous graphene and Au electrodes. Measurement of the charge injection limit with cathodal-first symmetric biphasic current pulses for the porous graphene electrode (c) before and (d) after doping. (e) Cycling with biphasic stimulation pulses to study degradation during charge injection. (f) EIS before and after 1 million stimulation cycles.CC BY · PubMed Central
Figure 4 In vivo high resolution cortical sensing. (a) A 16-electrode array placed at the pial surface of barrel cortex. (b) A 10-second recording example from an electrode. (c) Average power spectral density of the recorded signal over 5 minutes. (d) Spontaneous up and down states recorded cross the 16-electrode array. The distribution of down state amplitudes varied on a cycle-by-cycle basis. (e) Schematic of somatosensory-evoked potential recording setup. (f) Recorded somatosensory-evoked potentials. (g) The amplitude and (h) latency of the first positive peak of the somatosensory-evoked potentials.
Figure 4 In vivo high resolution cortical sensing. (a) A 16-electrode array placed at the pial surface of barrel cortex. (b) A 10-second recording example from an electrode. (c) Average power spectral density of the recorded signal over 5 minutes. (d) Spontaneous up and down states recorded cross the 16-electrode array. The distribution of down state amplitudes varied on a cycle-by-cycle basis. (e) Schematic of somatosensory-evoked potential recording setup. (f) Recorded somatosensory-evoked potentials. (g) The amplitude and (h) latency of the first positive peak of the somatosensory-evoked potentials.CC BY · PubMed Central
Figure 5 In vivo stimulation from cortical surface. (a) Schematic of cortical stimulation evoking transient ankle and knee flexion in the hindlimb. (b) A 16-electrode array placed on the pial surface of the motor cortex. (c) A resistive flex sensor spanning the knee joint. The inset illustrates the flexibility of the 16-electrode array as fabricated. (d) Stimulus evoking current (representing movement) response of the flex sensor in arbitrary units. (e) Movement response versus stimulation amplitude.
Figure 5 In vivo stimulation from cortical surface. (a) Schematic of cortical stimulation evoking transient ankle and knee flexion in the hindlimb. (b) A 16-electrode array placed on the pial surface of the motor cortex. (c) A resistive flex sensor spanning the knee joint. The inset illustrates the flexibility of the 16-electrode array as fabricated. (d) Stimulus evoking current (representing movement) response of the flex sensor in arbitrary units. (e) Movement response versus stimulation amplitude.CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 46 references

Research works printed but not linked: 1

  1. Peng, Z., Lin, J., Ye, R., Samuel, E. & Tour, J. Flexible and Stackable Laser-Induced Graphene Supercapacitors. ACS Appl. Mater. Interfaces 7, 3414–3419 (2015). · DOI · Paper page

Cited by

See all 213

Metadata

Authors
Lu, Y., Lyu, H., Richardson, A. G., Lucas, T. H., & Kuzum, D.
Affiliations
  • University of California San Diego (US)
  • University of Pennsylvania (US)
Venue
Scientific Reports
Published
2016-09-19
Volume
6
Issue
1
Pages
33526-33526
ISSN
2045-2322 (ISSN-L)
OpenAlex
W2521706094
Cited by
213
References
47
Citations by year
2026: 13 · 2025: 19 · 2024: 19 · 2023: 23 · 2022: 22 · 2021: 44 · 2020: 23 · 2019: 17 · 2018: 20 · 2017: 12
FWCI
9.16
Type
journal article
Language
en
Open access
Licence
Locations
  • Scientific Reports (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • eScholarship (California Digital Library) (submittedVersion, cc-by)
  • eScholarship (California Digital Library) (submittedVersion)
Funders
  • University of California, San Diego
  • Office of Naval Research
Topics
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
  • Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
  • Social Sciences › Education › Undergraduate Neuroscience Education and Research
Keywords
porous graphene, neural sensing, brain-computer interface, neuromodulation, charge injection, electrode impedance, cortical mapping

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.