Flexible Neural Electrode Array Based-on Porous Graphene for Cortical Microstimulation and Sensing
Open accessThe DOI matches its Crossref record; 46 of the 47 references it cites were found in a registry or an index.
Abstract
Neural sensing and stimulation have been the backbone of neuroscience research, brain-machine interfaces and clinical neuromodulation therapies for decades. To-date, most of the neural stimulation systems have relied on sharp metal microelectrodes with poor electrochemical properties that induce extensive damage to the tissue and significantly degrade the long-term stability of implantable systems. Here, we demonstrate a flexible cortical microelectrode array based on porous graphene, which is capable of efficient electrophysiological sensing and stimulation from the brain surface, without penetrating into the tissue. Porous graphene electrodes show superior impedance and charge injection characteristics making them ideal for high efficiency cortical sensing and stimulation. They exhibit no physical delamination or degradation even after 1 million biphasic stimulation cycles, confirming high endurance. In in vivo experiments with rodents, same array is used to sense brain activity patterns with high spatio-temporal resolution and to control leg muscles with high-precision electrical stimulation from the cortical surface. Flexible porous graphene array offers a minimally invasive but high efficiency neuromodulation scheme with potential applications in cortical mapping, brain-computer interfaces, treatment of neurological disorders, where high resolution and simultaneous recording and stimulation of neural activity are crucial.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures





Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“The first is penetrating microelectrodes with low-charge/phase thresholds, high-charge density thresholds and smaller surface area, which are more suitable for stimulating specific functional areas in a selective and high spatial resolution way.[543,544]”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [543]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Measurement of the Elastic Properties and Intrinsic Strength of Monolayer Graphene
Lee, C., Wei, X., Kysar, J. W., & Hone, J. (2008) · Science · doi:10.1126/science.1157996 · Cited by 20,847
Superior Thermal Conductivity of Single-Layer Graphene
Balandin, A. A., Ghosh, S., Bao, W., Calizo, I., Teweldebrhan, D., Miao, F., & Lau, C. N. (2008) · Nano Letters · doi:10.1021/nl0731872 · Cited by 13,823
Graphene photonics and optoelectronics
Bonaccorso, F., Sun, Z., Hasan, T., & Ferrari, A. C. (2010) · Nature Photonics · doi:10.1038/nphoton.2010.186 · Cited by 7,726
Science and technology roadmap for graphene, related two-dimensional crystals, and hybrid systems
Ferrari, A. C., Bonaccorso, F., Fal'ko, V., Novoselov, K. S., Roche, S., Bøggild, P., Borini, S., Koppens, F. H. L., Palermo, V., Pugno, N., et al. (2015) · Nanoscale · doi:10.1039/c4nr01600a · Cited by 3,027
Laser-induced porous graphene films from commercial polymers
Lin, J., Peng, Z., Liu, Y., Ruiz-Zepeda, F., Ye, R., Samuel, E. L. G., Yacaman, M. J., Yakobson, B. I., & Tour, J. M. (2014) · Nature Communications · doi:10.1038/ncomms6714 · Cited by 2,946
Neural Stimulation and Recording Electrodes
Cogan, S. F. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160518 · Cited by 2,243
Liu, H., Liu, Y., & Zhu, D. (2011) · J. Mater. Chem. · doi:10.1039/c0jm02922j · Cited by 1,629
(2001) · New England Journal of Medicine · doi:10.1056/nejmoa000827 · Cited by 1,514
Viventi, J., Kim, D.-H., Vigeland, L., Frechette, E. S., Blanco, J. A., Kim, Y.-S., Avrin, A. E., Tiruvadi, V. R., Hwang, S.-W., Vanleer, A. C., et al. (2011) · Nature Neuroscience · doi:10.1038/nn.2973 · Cited by 1,136
NeuroGrid: recording action potentials from the surface of the brain
Khodagholy, D., Gelinas, J. N., Thesen, T., Doyle, W., Devinsky, O., Malliaras, G. G., & Buzsáki, G. (2015) · Nature Neuroscience · doi:10.1038/nn.3905 · Cited by 938
Flexible Boron-Doped Laser-Induced Graphene Microsupercapacitors
Peng, Z., Ye, R., Mann, J. A., Zakhidov, D., Li, Y., Smalley, P. R., Lin, J., & Tour, J. M. (2015) · ACS Nano · doi:10.1021/acsnano.5b00436 · Cited by 712
Canales, A., Jia, X., Froriep, U. P., Koppes, R. A., Tringides, C. M., Selvidge, J., Lu, C., Hou, C., Wei, L., Fink, Y., et al. (2015) · Nature Biotechnology · doi:10.1038/nbt.3093 · Cited by 668
Three-dimensional graphene foam as a biocompatible and conductive scaffold for neural stem cells
Li, N., Zhang, Q., Gao, S., Song, Q., Huang, R., Wang, L., Liu, L., Dai, J., Tang, M., & Cheng, G. (2013) · Scientific Reports · doi:10.1038/srep01604 · Cited by 660
Maynard, E. M., Nordhausen, C. T., & Normann, R. A. (1997) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/s0013-4694(96)95176-0 · Cited by 640
High‐Performance Pseudocapacitive Microsupercapacitors from Laser‐Induced Graphene
Li, L., Zhang, J., Peng, Z., Li, Y., Gao, C., Ji, Y., Ye, R., Kim, N. D., Zhong, Q., Yang, Y., et al. (2016) · Advanced Materials · doi:10.1002/adma.201503333 · Cited by 571
Kuzum, D., Takano, H., Shim, E., Reed, J. C., Juul, H., Richardson, A. G., de Vries, J., Bink, H., Dichter, M. A., Lucas, T. H., et al. (2014) · Nature Communications · doi:10.1038/ncomms6259 · Cited by 546
Self-citationA model of safe levels for electrical stimulation
Shannon, R. V. (1992) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.126616 · Cited by 526
Flexible and Stackable Laser-Induced Graphene Supercapacitors
Peng, Z., Lin, J., Ye, R., Samuel, E. L. G., & Tour, J. M. (2015) · ACS Applied Materials & Interfaces · doi:10.1021/am509065d · Cited by 470
Brain-Computer Interfaces Using Electrocorticographic Signals
Schalk, G., & Leuthardt, E. C. (2011) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2011.2172408 · Cited by 427
Neural Stimulation with a Carbon Nanotube Microelectrode Array
Wang, K., Fishman, H. A., Dai, H., & Harris, J. S. (2006) · Nano Letters · doi:10.1021/nl061241t · Cited by 415
Three-dimensional macroporous nanoelectronic networks as minimally invasive brain probes
Xie, C., Liu, J., Fu, T.-M., Dai, X., Zhou, W., & Lieber, C. M. (2015) · Nature Materials · doi:10.1038/nmat4427 · Cited by 404
Strong Suppression of Electrical Noise in Bilayer Graphene Nanodevices
Lin, Y.-M., & Avouris, P. (2008) · Nano Letters · doi:10.1021/nl080241l · Cited by 396
Tissue damage thresholds during therapeutic electrical stimulation
Cogan, S. F., Ludwig, K. A., Welle, C. G., & Takmakov, P. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/2/021001 · Cited by 386
In vitro electrical properties for iridium oxide versus titanium nitride stimulating electrodes
Weiland, J. D., Anderson, D. J., & Humayun, M. S. (2002) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2002.805487 · Cited by 382
Highly Conformable Conducting Polymer Electrodes for In Vivo Recordings
Khodagholy, D., Doublet, T., Gurfinkel, M., Quilichini, P., Ismailova, E., Leleux, P., Herve, T., Sanaur, S., Bernard, C., & Malliaras, G. G. (2011) · Advanced Materials · doi:10.1002/adma.201102378 · Cited by 373
Zesiewicz, T. A., Elble, R., Louis, E. D., Hauser, R. A., Sullivan, K. L., Dewey, R. B., Ondo, W. G., Gronseth, G. S., & Weiner, W. J. (2005) · Neurology · doi:10.1212/01.wnl.0000163769.28552.cd · Cited by 371
Rose, T. L., & Robblee, L. S. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.61038 · Cited by 358
Chemical Doping of Large-Area Stacked Graphene Films for Use as Transparent, Conducting Electrodes
Kasry, A., Kuroda, M. A., Martyna, G. J., Tulevski, G. S., & Bol, A. A. (2010) · ACS Nano · doi:10.1021/nn100508g · Cited by 342
Soft Materials in Neuroengineering for Hard Problems in Neuroscience
Jeong, J.-W., Shin, G., Park, S. I., Yu, K. J., Xu, L., & Rogers, J. A. (2015) · Neuron · doi:10.1016/j.neuron.2014.12.035 · Cited by 333
Poly (3,4-Ethylenedioxythiophene) for Chronic Neural Stimulation
Cui, X. T., & Zhou, D. D. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.909811 · Cited by 277
Technology Insight: neuroengineering and epilepsy—designing devices for seizure control
Stacey, W. C., & Litt, B. (2008) · Nature Clinical Practice Neurology · doi:10.1038/ncpneuro0750 · Cited by 234
Over-pulsing degrades activated iridium oxide films used for intracortical neural stimulation
Cogan, S. F., Guzelian, A. A., Agnew, W. F., Yuen, T. G. H., & McCreery, D. B. (2004) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2004.02.019 · Cited by 210
Wilks, S. (2009) · Frontiers in Neuroengineering · doi:10.3389/neuro.16.007.2009 · Cited by 188
Comparison of neural damage induced by electrical stimulation with faradaic and capacitor electrodes
McCreery, D. B., Agnew, W. F., Yuen, T. G. H., & Bullara, L. A. (1988) · Annals of Biomedical Engineering · doi:10.1007/bf02368010 · Cited by 163
Towards Large-Scale, Human-Based, Mesoscopic Neurotechnologies
Chang, E. F. (2015) · Neuron · doi:10.1016/j.neuron.2015.03.037 · Cited by 163
Layered Carbon Nanotube-Polyelectrolyte Electrodes Outperform Traditional Neural Interface Materials
Jan, E., Hendricks, J. L., Husaini, V., Richardson-Burns, S. M., Sereno, A., Martin, D. C., & Kotov, N. A. (2009) · Nano Letters · doi:10.1021/nl902187z · Cited by 125
PEDOT-CNT-Coated Low-Impedance, Ultra-Flexible, and Brain-Conformable Micro-ECoG Arrays
Castagnola, E., Maiolo, L., Maggiolini, E., Minotti, A., Marrani, M., Maita, F., Pecora, A., Angotzi, G. N., Ansaldo, A., Boffini, M., et al. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2342880 · Cited by 113
Johnson, L. A., Wander, J. D., Sarma, D., Su, D. K., Fetz, E. E., & Ojemann, J. G. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/3/036021 · Cited by 111
Moran, D. W. (2010) · Current Opinion in Neurobiology · doi:10.1016/j.conb.2010.09.010 · Cited by 104
Biocompatibility of pristine graphene for neuronal interface: Laboratory investigation
Sahni, D., Jea, A. H., Mata, J. A., Marcano, D. C., Sivaganesan, A., Berlin, J. M., Tatsui, C. E., Sun, Z., Luerssen, T. G., Meng, S., et al. (2013) · Journal of Neurosurgery Pediatrics · doi:10.3171/2013.1.peds12374 · Cited by 99
Chronic epidural motor cortical stimulation for movement disorders
Priori, A., & Lefaucheur, J. (2007) · The Lancet Neurology · doi:10.1016/s1474-4422(07)70056-x · Cited by 80
Assessment of capacitor electrodes for intracortical neural stimulation
Rose, T. L., Kelliher, E. M., & Robblee, L. S. (1985) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(85)90001-9 · Cited by 77
Huang, H.-C., Chung, C.-J., Hsieh, C., Kuo, P., & Teng, H. (2016) · Nano Energy · doi:10.1016/j.nanoen.2015.12.012 · Cited by 71
Optogenetic micro-electrocorticography for modulating and localizing cerebral cortex activity
Richner, T. J., Thongpang, S., Brodnick, S. K., Schendel, A. A., Falk, R., Krugner-Higby, L. A., Pashaie, R., & Williams, J. C. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/1/016010 · Cited by 69
A microelectrode for delivery of defined charge densities
Bullara, L. A., McCreery, D. B., Yuen, T. G. H., & Agnew, W. F. (1983) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(83)90104-8 · Cited by 35
Cogan, S. F., Ehrlich, J., Plante, T. D., Gingerich, M. D., & Shire, D. B. (2010) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2050690 · Cited by 35
Research works printed but not linked: 1
- Peng, Z., Lin, J., Ye, R., Samuel, E. & Tour, J. Flexible and Stackable Laser-Induced Graphene Supercapacitors. ACS Appl. Mater. Interfaces 7, 3414–3419 (2015). · DOI · Paper page
Cited by
Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics
Heng, W., Solomon, S., & Gao, W. (2022) · Advanced Materials · doi:10.1002/adma.202107902 · Cited by 609
Two-Dimensional Ti3C2 MXene for High-Resolution Neural Interfaces
Driscoll, N., Richardson, A. G., Maleski, K., Anasori, B., Adewole, O., Lelyukh, P., Escobedo, L., Cullen, D. K., Lucas, T. H., Gogotsi, Y., et al. (2018) · ACS Nano · doi:10.1021/acsnano.8b06014 · Cited by 312
Self-citationEmerging Modalities and Implantable Technologies for Neuromodulation
Won, S. M., Song, E., Reeder, J. T., & Rogers, J. A. (2020) · Cell · doi:10.1016/j.cell.2020.02.054 · Cited by 291
Liang, Y., Offenhäusser, A., Ingebrandt, S., & Mayer, D. (2021) · Advanced Healthcare Materials · doi:10.1002/adhm.202100061 · Cited by 239
Next-generation interfaces for studying neural function
Frank, J. A., Antonini, M.-J., & Anikeeva, P. (2019) · Nature Biotechnology · doi:10.1038/s41587-019-0198-8 · Cited by 241
Metadata
- Authors
- Lu, Y., Lyu, H., Richardson, A. G., Lucas, T. H., & Kuzum, D.
- Affiliations
- University of California San Diego (US)
- University of Pennsylvania (US)
- Venue
- Scientific Reports
- Published
- 2016-09-19
- Volume
- 6
- Issue
- 1
- Pages
- 33526-33526
- ISSN
- 2045-2322 (ISSN-L)
- PMC
- PMC5027596
- OpenAlex
- W2521706094
- Cited by
- 213
- References
- 47
- Citations by year
- 2026: 13 · 2025: 19 · 2024: 19 · 2023: 23 · 2022: 22 · 2021: 44 · 2020: 23 · 2019: 17 · 2018: 20 · 2017: 12
- FWCI
- 9.16
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by
- creativecommons.org/licenses/by/4.0 (tdm)
- creativecommons.org/licenses/by/4.0 (vor)
- Locations
- Scientific Reports (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- eScholarship (California Digital Library) (submittedVersion, cc-by)
- eScholarship (California Digital Library) (submittedVersion)
- Funders
- University of California, San Diego
- Office of Naval Research
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
- Social Sciences › Education › Undergraduate Neuroscience Education and Research
- Keywords
- porous graphene, neural sensing, brain-computer interface, neuromodulation, charge injection, electrode impedance, cortical mapping
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.