Microfluidic co-culture system for cancer migratory analysis and anti-metastatic drugs screening
Open accessThe DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
Tumour metastasis is an important reason for cancer death, and cancer cell migration is an important step in the process of tumour metastasis. Studying cancer cell migration is of great significance. Here, we present a novel microfluidic co-culture system and establish mild, moderate and severe cancer models by using HMEpiC and MDA-MB–231 cells to study cancer cell migration and anti-cancer drug screening. Using this device, we achieved high cell viability (over 90%) and a stable analysis of the migration ability of cancer cells. We observed that the density of the cancer cells determined the probability of the occurrence of metastatic cells and that the induction of normal cells affected the metastatic velocity of each cancer cell. We verified that the increase in the migration ability of MDA-MB-231 cells co-cultured with HMEpiC cells was relative to the increased secretion of IL-6 and that this was verified by an IL-6 inhibitor assay. This co-culture also led to decreased CK-14 secretion and morphological changes in HMEpiC cells. Finally, significant inhibition of paclitaxel and tamoxifen on cancer migration was observed. Taken together, our microfluidic device could be a useful tool for the quantitation of the migratory capability and anti-metastatic drug screening.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biomarkers for epithelial-mesenchymal transitions
Zeisberg, M., & Neilson, E. G. (2009) · Journal of Clinical Investigation · doi:10.1172/jci36183 · Cited by 2,299 · cited 1×
“This is an important feature of EMT 46,47 , and we also observed a morphological change in the HMEpiC cells co-cultured with cancer cells (Fig.”
Three-dimensional microfluidic model for tumor cell intravasation and endothelial barrier function
Zervantonakis, I. K., Hughes-Alford, S. K., Charest, J. L., Condeelis, J. S., Gertler, F. B., & Kamm, R. D. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1210182109 · Cited by 872 · cited 3×
“…based on microfluidic devices, and some scholars have established co-culture tumour models in microfluidic devices to solely study cancer cell migration 11,27 , only a few studies have focused on the interaction between cells and studied the role of normal cells in breast cancer migration 10,28 .”
Interstitial flow influences direction of tumor cell migration through competing mechanisms
Polacheck, W. J., Charest, J. L., & Kamm, R. D. (2011) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1103581108 · Cited by 509 · cited 1×
“In addition, the factors of the tumour microenvironment, such as cell density, greatly influence cancer cell migration and drug screening 10,25,26,29,30 .”
Sung, K. E., Yang, N., Pehlke, C., Keely, P. J., Eliceiri, K. W., Friedl, A., & Beebe, D. J. (2011) · Integr. Biol. · doi:10.1039/c0ib00063a · Cited by 226
A microengineered pathophysiological model of early-stage breast cancer
Choi, Y., Hyun, E., Seo, J., Blundell, C., Kim, H. C., Lee, E., Lee, S. H., Moon, A., Moon, W. K., & Huh, D. (2015) · Lab on a Chip · doi:10.1039/c5lc00514k · Cited by 222
Nguyen, T. A., Yin, T.-I., Reyes, D., & Urban, G. A. (2013) · Analytical Chemistry · doi:10.1021/ac402761s · Cited by 189
Migration dynamics of breast cancer cells in a tunable 3D interstitial flow chamber
Haessler, U., Teo, J. C. M., Foretay, D., Renaud, P., & Swartz, M. A. (2012) · Integrative Biology · doi:10.1039/c1ib00128k · Cited by 176
Cross talk between cancer and immune cells: exploring complex dynamics in a microfluidic environment
Businaro, L., De Ninno, A., Schiavoni, G., Lucarini, V., Ciasca, G., Gerardino, A., Belardelli, F., Gabriele, L., & Mattei, F. (2013) · Lab Chip · doi:10.1039/c2lc40887b · Cited by 162 · cited 2×
“…based on microfluidic devices, and some scholars have established co-culture tumour models in microfluidic devices to solely study cancer cell migration 11,27 , only a few studies have focused on the interaction between cells and studied the role of normal cells in breast cancer migration 10,28 .”
Cited by
Application of microfluidic chip technology in pharmaceutical analysis: A review
Cui, P., & Wang, S. (2019) · Journal of Pharmaceutical Analysis · doi:10.1016/j.jpha.2018.12.001 · Cited by 390
Shirure, V. S., Bi, Y., Curtis, M. B., Lezia, A., Goedegebuure, M. M., Goedegebuure, S. P., Aft, R., Fields, R. C., & George, S. C. (2018) · Lab on a Chip · doi:10.1039/c8lc00596f · Cited by 316
Tumour-on-a-chip: microfluidic models of tumour morphology, growth and microenvironment
Tsai, H.-F., Trubelja, A., Shen, A. Q., & Bao, G. (2017) · Journal of The Royal Society Interface · doi:10.1098/rsif.2017.0137 · Cited by 214
Cell Culture Based in vitro Test Systems for Anticancer Drug Screening
Kitaeva, K. V., Rutland, C. S., Rizvanov, A. A., & Solovyeva, V. V. (2020) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2020.00322 · Cited by 142
Wang, Y., Wu, D., Wu, G., Wu, J., Lu, S., Lo, J., He, Y., Zhao, C., Zhao, X., Zhang, H., et al. (2020) · Theranostics · doi:10.7150/thno.38736 · Cited by 93
“In another study, normal breast cells are co-cultured with breast cancer cells to simulate cancer models at mild, moderate, and severe stages, in which cell density is found to be highly correlated with the incidence of metastasis [28].”
BackgroundA 3D Microfluidic Model to Recapitulate Cancer Cell Migration and Invasion
Toh, Y.-C., Raja, A., Yu, H., & Van Noort, D. (2018) · Bioengineering · doi:10.3390/bioengineering5020029 · Cited by 57
“Microfluidic cancer migration models also allow the application of chemo-attractant gradients [16,17], improve imaging resolution [18] and can look at interaction with other cells [19,20].”
BackgroundMicrofluidic system for modelling 3D tumour invasion into surrounding stroma and drug screening
Du, Z., Mi, S., Yi, X., Xu, Y., & Sun, W. (2018) · Biofabrication · doi:10.1088/1758-5090/aac70c · Cited by 42
Self-citation
Metadata
- Authors
- Mi, S., Du, Z., Xu, Y., Wu, Z., Qian, X., Zhang, M., & Sun, W.
- Venue
- Scientific Reports
- Published
- 2016-10-20
- Volume
- 6
- Issue
- 1
- Pages
- 35544-35544
- ISSN
- 2045-2322 (ISSN-L)
- OpenAlex
- W2533232420
- Cited by
- 83
- References
- 8
- FWCI
- 4.48
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.