The DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
Microsample preparation by dielectrophoresis: isolation of malaria
Open accessAbstract
An important enabling factor for realising integrated micro fluidic analysis instruments for medical diagnostics purposes is front-end sample preparation. Dielectrophoresis is a method that offers great potential for cell discrimination and isolation for sample processing, and here we have applied it to the problem of isolating malaria-infected cells from blood. During development of the malarial pathogen, Plasmodium falciparum, increases occur in the ionic permeability of the plasma membrane of infected erythrocytes. When challenged by suspension in a low conductivity medium, infected cells lose internal ions while uninfected cells retain them. The resultant dielectric differences between infected and uninfected cells were exploited by dielectrophoretic manipulation in spatially inhomogeneous, travelling electrical fields produced by two types of microelectrode arrays. Parasitised cells of ring form or later stage from cultures and clinical specimens were isolated by steric dielectric field-flow-fractionation, focused at the centre of a spiral electrode array, and identified and counted. The dielectrophoretic methods require only a few micro litres of blood, and should be applicable to the production of small, low-cost automated devices for assessing parasite concentrations with potential applicability to drug sensitivity studies and the diagnosis of malaria. By simple adjustment of the electrical field parameters, other cell subpopulations that characterise disease, such as residual cancer cells in blood, can be similarly isolated and analysed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Human Malaria Parasites in Continuous Culture
Trager, W., & Jensen, J. B. (1976) · Science · doi:10.1126/science.781840 · Cited by 7,844
Dielectrophoresis: The Behavior of Neutral Matter in Nonuniform Electric Fields
Pohl, H. A. (1978) · Medical Entomology and Zoology · Cited by 935
Pethig, R., & Kell, D. B. (1987) · Physics in Medicine and Biology · doi:10.1088/0031-9155/32/8/001 · Cited by 796
Separation of human breast cancer cells from blood by differential dielectric affinity.
Becker, F. F., Wang, X. B., Huang, Y., Pethig, R., Vykoukal, J., & Gascoyne, P. R. (1995) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.92.3.860 · Cited by 680
Self-citationSeparation of Submicron Bioparticles by Dielectrophoresis
Morgan, H., Hughes, M. P., & Green, N. G. (1999) · Biophysical Journal · doi:10.1016/s0006-3495(99)76908-0 · Cited by 523
Dielectrophoretic Sorting of Particles and Cells in a Microsystem
Fiedler, S., Shirley, S. G., Schnelle, T., & Fuhr, G. (1998) · Analytical Chemistry · doi:10.1021/ac971063b · Cited by 432
Dielectrophoretic separation of cancer cells from blood
Gascoyne, P. R. C., Wang, X.-B., Huang, Y., & Becker, F. F. (1997) · IEEE Transactions on Industry Applications · doi:10.1109/28.585856 · Cited by 406
Self-citationHoward, R. J., Uni, S., Aikawa, M., Aley, S. B., Leech, J. H., Lew, A. M., Wellems, T. E., Rener, J., & Taylor, D. W. (1986) · The Journal of cell biology · doi:10.1083/jcb.103.4.1269 · Cited by 321
Introducing dielectrophoresis as a new force field for field-flow fractionation
Huang, Y., Wang, X. B., Becker, F. F., & Gascoyne, P. R. (1997) · Biophysical Journal · doi:10.1016/s0006-3495(97)78144-x · Cited by 302
Self-citationA review of practical techniques for the diagnosis of malaria
T. MAKLER C. J. PALMER A. L. AGER, M. (1998) · Annals of Tropical Medicine And Parasitology · doi:10.1080/00034989859401 · Cited by 301
Cited by
Microfluidics: Fluid physics at the nanoliter scale
Squires, T. M., & Quake, S. R. (2005) · Reviews of Modern Physics · doi:10.1103/revmodphys.77.977 · Cited by 4,379
Microfluidic diagnostic technologies for global public health
Yager, P., Edwards, T., Fu, E., Helton, K., Nelson, K., Tam, M. R., & Weigl, B. H. (2006) · Nature · doi:10.1038/nature05064 · Cited by 1,979
Massively parallel manipulation of single cells and microparticles using optical images
Chiou, P. Y., Ohta, A. T., & Wu, M. C. (2005) · Nature · doi:10.1038/nature03831 · Cited by 1,444
Particle separation by dielectrophoresis
Gascoyne, P. R. C., & Vykoukal, J. (2002) · ELECTROPHORESIS · doi:10.1002/1522-2683(200207)23:13<1973::aid-elps1973>3.0.co;2-1 · Cited by 826
Self-citationPCR microfluidic devices for DNA amplification
Zhang, C., Xu, J., Ma, W., & Zheng, W. (2006) · Biotechnology Advances · doi:10.1016/j.biotechadv.2005.10.002 · Cited by 634
Microfluidics for cell separation
Bhagat, A. A. S., Bow, H., Hou, H. W., Tan, S. J., Han, J., & Lim, C. T. (2010) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-010-0611-4 · Cited by 632
Toner, M., & Irimia, D. (2005) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.7.011205.135108 · Cited by 623
Isolation of rare cells from cell mixtures by dielectrophoresis
Gascoyne, P. R. C., Noshari, J., Anderson, T. J., & Becker, F. F. (2009) · ELECTROPHORESIS · doi:10.1002/elps.200800373 · Cited by 436
Self-citationCurrent and Developing Technologies for Monitoring Agents of Bioterrorism and Biowarfare
Lim, D. V., Simpson, J. M., Kearns, E. A., & Kramer, M. F. (2005) · Clinical Microbiology Reviews · doi:10.1128/cmr.18.4.583-607.2005 · Cited by 417
Dielectrophoresis in microfluidics technology
Çetin, B., & Li, D. (2011) · ELECTROPHORESIS · doi:10.1002/elps.201100167 · Cited by 411
Gupta, V., Jafferji, I., Garza, M., Melnikova, V. O., Hasegawa, D. K., Pethig, R., & Davis, D. W. (2012) · Biomicrofluidics · doi:10.1063/1.4731647 · Cited by 383
On-chip micromanipulation and assembly of colloidal particles by electric fields
Velev, O. D., & Bhatt, K. H. (2006) · Soft Matter · doi:10.1039/b605052b · Cited by 361
Heath, J. R., & Davis, M. E. (2008) · Annual Review of Medicine · doi:10.1146/annurev.med.59.061506.185523 · Cited by 354
Dielectrophoresis-Based Sample Handling in General-Purpose Programmable Diagnostic Instruments
Gascoyne, P. R. C., & Vykoukal, J. V. (2004) · Proceedings of the IEEE · doi:10.1109/jproc.2003.820535 · Cited by 321
Self-citationGagnon, Z. R. (2011) · ELECTROPHORESIS · doi:10.1002/elps.201100060 · Cited by 317
Rare cell isolation and analysis in microfluidics
Chen, Y., Li, P., Huang, P.-H., Xie, Y., Mai, J. D., Wang, L., Nguyen, N.-T., & Huang, T. J. (2014) · Lab on a Chip · doi:10.1039/c3lc90136j · Cited by 307
Hou, H. W., Bhagat, A. A. S., Lin Chong, A. G., Mao, P., Wei Tan, K. S., Han, J., & Lim, C. T. (2010) · Lab on a Chip · doi:10.1039/c003873c · Cited by 300
Isolation of Circulating Tumor Cells by Dielectrophoresis
Gascoyne, P., & Shim, S. (2014) · Cancers · doi:10.3390/cancers6010545 · Cited by 275
Self-citationDielectrophoretic separation of bioparticles in microdevices: A review
Jubery, T. Z., Srivastava, S. K., & Dutta, P. (2014) · ELECTROPHORESIS · doi:10.1002/elps.201300424 · Cited by 262
Urban, P., & Fernandez-Busquets, X. (2014) · Current Medicinal Chemistry · doi:10.2174/09298673113206660292 · Cited by 39
Metadata
- Authors
- Gascoyne, P., Mahidol, C., Ruchirawat, M., Satayavivad, J., Watcharasit, P., & Becker, F. F.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2002
- Volume
- 2
- Issue
- 2
- Pages
- 70
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2125231985
- Cited by
- 278
- References
- 33
- FWCI
- 7.47
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.