The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
A passive pumping method for microfluidic devices
Abstract
The surface energy present in a small drop of liquid is used to pump the liquid through a microchannel. The flow rate is determined by the volume of the drop present on the pumping port of the microchannel. A flow rate of 1.25 microL s(-1) is demonstrated using 0.5 microL drops of water. Two other fluid manipulations are demonstrated using the passive pumping method: pumping liquid to a higher gravitational potential energy and creating a plug within a microchannel.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rapid Prototyping of Microfluidic Systems in Poly(dimethylsiloxane)
Duffy, D. C., McDonald, J. C., Schueller, O. J. A., & Whitesides, G. M. (1998) · Analytical Chemistry · doi:10.1021/ac980656z · Cited by 5,288
Monolithic Microfabricated Valves and Pumps by Multilayer Soft Lithography
Unger, M. A., Chou, H.-P., Thorsen, T., Scherer, A., & Quake, S. R. (2000) · Science · doi:10.1126/science.288.5463.113 · Cited by 4,010
Microfabricated Centrifugal Microfluidic Systems: Characterization and Multiple Enzymatic Assays
Duffy, D. C., Gillis, H. L., Lin, J., Sheppard, N. F., & Kellogg, G. J. (1999) · Analytical Chemistry · doi:10.1021/ac990682c · Cited by 478
Microchip Injection and Separation Anomalies Due to Pressure Effects
Crabtree, H. J., Cheong, E. C. S., Tilroe, D., & Backhouse, C. (2001) · Analytical Chemistry · doi:10.1021/ac010217r · Cited by 138
Cited by
The present and future role of microfluidics in biomedical research
Sackmann, E. K., Fulton, A. L., & Beebe, D. J. (2014) · Nature · doi:10.1038/nature13118 · Cited by 2,995
Self-citationCell migration into scaffolds under co-culture conditions in a microfluidic platform
Chung, S., Sudo, R., Mack, P. J., Wan, C.-R., Vickerman, V., & Kamm, R. D. (2009) · Lab Chip · doi:10.1039/b807585a · Cited by 519
Disposable Smart Lab on a Chip for Point-of-Care Clinical Diagnostics
Ahn, C. H., Choi, J.-W., Beaucage, G., Nevin, J., Lee, J.-B., Puntambekar, A., & Lee, R. J. Y. (2004) · Proceedings of the IEEE · doi:10.1109/jproc.2003.820548 · Cited by 504
Capillary microfluidics in microchannels: from microfluidic networks to capillaric circuits
Olanrewaju, A., Beaugrand, M., Yafia, M., & Juncker, D. (2018) · Lab on a Chip · doi:10.1039/c8lc00458g · Cited by 451
Experimental anti-tumor therapy in 3-D: Spheroids – old hat or new challenge?
Friedrich, J., Ebner, R., & Kunz-Schughart, L. A. (2007) · International Journal of Radiation Biology · doi:10.1080/09553000701727531 · Cited by 446
Microfluidics for flow cytometric analysis of cells and particles
Huh, D., Gu, W., Kamotani, Y., Grotberg, J. B., & Takayama, S. (2005) · Physiological Measurement · doi:10.1088/0967-3334/26/3/r02 · Cited by 396
Integrated Microreactors for Reaction Automation: New Approaches to Reaction Development
McMullen, J. P., & Jensen, K. F. (2010) · Annual Review of Analytical Chemistry · doi:10.1146/annurev.anchem.111808.073718 · Cited by 359
Microfluidics for medical diagnostics and biosensors
Rivet, C., Lee, H., Hirsch, A., Hamilton, S., & Lu, H. (2011) · Chemical Engineering Science · doi:10.1016/j.ces.2010.08.015 · Cited by 356
Cell Culture Models in Microfluidic Systems
Meyvantsson, I., & Beebe, D. J. (2008) · Annual Review of Analytical Chemistry · doi:10.1146/annurev.anchem.1.031207.113042 · Cited by 345
Self-citationAn outlook on microfluidics: the promise and the challenge
Battat, S., Weitz, D. A., & Whitesides, G. M. (2022) · Lab on a Chip · doi:10.1039/d1lc00731a · Cited by 333
Microvalves and Micropumps for BioMEMS
Au, A. K., Lai, H., Utela, B. R., & Folch, A. (2011) · Micromachines · doi:10.3390/mi2020179 · Cited by 332
Organs-on-chips: breaking the in vitro impasse
Meer, A. D. V. D., & Berg, A. V. D. (2012) · Integrative Biology · doi:10.1039/c2ib00176d · Cited by 314
Tubeless microfluidic angiogenesis assay with three-dimensional endothelial-lined microvessels
Bischel, L. L., Young, E. W. K., Mader, B. R., & Beebe, D. J. (2013) · Biomaterials · doi:10.1016/j.biomaterials.2012.11.005 · Cited by 265
Self-citationSung, K. E., Yang, N., Pehlke, C., Keely, P. J., Eliceiri, K. W., Friedl, A., & Beebe, D. J. (2011) · Integr. Biol. · doi:10.1039/c0ib00063a · Cited by 226
Self-citationPermeation-driven flow in poly(dimethylsiloxane) microfluidic devices.
Randall, G. C., & Doyle, P. S. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0503287102 · Cited by 220
Nguyen, T. A., Yin, T.-I., Reyes, D., & Urban, G. A. (2013) · Analytical Chemistry · doi:10.1021/ac402761s · Cited by 189
Berthier, E., Warrick, J., Yu, H., & Beebe, D. J. (2008) · Lab on a Chip · doi:10.1039/b717422e · Cited by 114
Self-citationMicrofluidic model of ductal carcinoma in situ with 3D, organotypic structure
Bischel, L. L., Beebe, D. J., & Sung, K. E. (2015) · BMC Cancer · doi:10.1186/s12885-015-1007-5 · Cited by 110
Self-citationMethods to study the tumor microenvironment under controlled oxygen conditions
Byrne, M. B., Leslie, M. T., Gaskins, H. R., & Kenis, P. J. A. (2014) · Trends in Biotechnology · doi:10.1016/j.tibtech.2014.09.006 · Cited by 104
Lugo-Cintrón, K. M., Gong, M. M., Ayuso, J. M., Tomko, L. A., Beebe, D. J., Virumbrales-Muñoz, M., & Ponik, S. M. (2020) · Cancers · doi:10.3390/cancers12051173 · Cited by 103
Self-citationGong, M. M., Lugo-Cintron, K. M., White, B. R., Kerr, S. C., Harari, P. M., & Beebe, D. J. (2019) · Biomaterials · doi:10.1016/j.biomaterials.2019.119225 · Cited by 87
Self-citationKim, S. M., Kang, Y. S., Ahn, C., Jang, S., Kim, M., Sung, Y.-E., Yoo, S. J., & Choi, M. (2016) · Journal of Power Sources · doi:10.1016/j.jpowsour.2016.03.083 · Cited by 52
Regier, M. C., Maccoux, L. J., Weinberger, E. M., Regehr, K. J., Berry, S. M., Beebe, D. J., & Alarid, E. T. (2016) · Biomedical Microdevices · doi:10.1007/s10544-016-0083-x · Cited by 23
Self-citation
Metadata
- Authors
- Walker, G. M., & Beebe, D. J.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2002
- Volume
- 2
- Issue
- 3
- Pages
- 131
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2049550437
- Cited by
- 420
- References
- 4
- FWCI
- 1.72
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.