The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Multi-step synthesis of nanoparticles performed on millisecond time scale in a microfluidic droplet-based system
Abstract
This paper reports a plug-based, microfluidic method for performing multi-step chemical reactions with millisecond time-control. It builds upon a previously reported method where aqueous reagents were injected into a flow of immiscible fluid (fluorocarbons)(H. Song et al., Angew. Chem. Int. Ed., 2003, 42, 768). The aqueous reagents formed plugs--droplets surrounded and transported by the immiscible fluid. Winding channels rapidly mixed the reagents in droplets. This paper shows that further stages of the reaction could be initiated by flowing additional reagent streams directly into the droplets of initial reaction mixture. The conditions necessary for an aqueous stream to merge with aqueous droplets were characterized. The Capillary number could be used to predict the behavior of the two-phase flow at the merging junction. By transporting solid reaction products in droplets, the products were kept from aggregating on the walls of the microchannels. To demonstrate the utility of this microfluidic method it was used to synthesize colloidal CdS and CdS/CdSe core-shell nanoparticles.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Murray, C. B., Norris, D. J., & Bawendi, M. G. (1993) · Journal of the American Chemical Society · doi:10.1021/ja00072a025 · Cited by 9,282
Engineering Flows in Small Devices: Microfluidics Toward a Lab-on-a-Chip
Stone, H. A., Stroock, A. D., & Ajdari, A. (2004) · Annual Review of Fluid Mechanics · doi:10.1146/annurev.fluid.36.050802.122124 · Cited by 3,666
Formation of dispersions using “flow focusing” in microchannels
Anna, S. L., Bontoux, N., & Stone, H. A. (2003) · Applied Physics Letters · doi:10.1063/1.1537519 · Cited by 2,302
Dynamic Pattern Formation in a Vesicle-Generating Microfluidic Device
Thorsen, T., Roberts, R. W., Arnold, F. H., & Quake, S. R. (2001) · Physical Review Letters · doi:10.1103/physrevlett.86.4163 · Cited by 2,051
An Integrated Nanoliter DNA Analysis Device
Burns, M. A., Johnson, B. N., Brahmasandra, S. N., Handique, K., Webster, J. R., Krishnan, M., Sammarco, T. S., Man, P. M., Jones, D., Heldsinger, D., et al. (1998) · Science · doi:10.1126/science.282.5388.484 · Cited by 1,299
Microreaction engineering — is small better?
Jensen, K. F. (2001) · Chemical Engineering Science · doi:10.1016/s0009-2509(00)00230-x · Cited by 1,124
A Microfluidic System for Controlling Reaction Networks in Time
Song, H., Tice, J. D., & Ismagilov, R. F. (2003) · Angewandte Chemie International Edition · doi:10.1002/anie.200390203 · Cited by 1,082
Self-citationTice, J. D., Song, H., Lyon, A. D., & Ismagilov, R. F. (2003) · Langmuir · doi:10.1021/la030090w · Cited by 722
Self-citationScreening of Protein Crystallization Conditions on a Microfluidic Chip Using Nanoliter-Size Droplets
Zheng, B., Roach, L. S., & Ismagilov, R. F. (2003) · Journal of the American Chemical Society · doi:10.1021/ja037166v · Cited by 697
Self-citationMillisecond Kinetics on a Microfluidic Chip Using Nanoliters of Reagents
Song, H., & Ismagilov, R. F. (2003) · Journal of the American Chemical Society · doi:10.1021/ja0354566 · Cited by 693
Self-citationMicrofluidics: Basic issues, applications, and challenges
Stone, H. A., & Kim, S. (2001) · AIChE Journal · doi:10.1002/aic.690470602 · Cited by 552
Ismagilov, R. F., Stroock, A. D., Kenis, P. J. A., Whitesides, G., & Stone, H. A. (2000) · Applied Physics Letters · doi:10.1063/1.126351 · Cited by 540
Self-citationMicro reactors: principles and applications in organic synthesis
Fletcher, P. D. I., Haswell, S. J., Pombo-Villar, E., Warrington, B. H., Watts, P., Wong, S. Y. F., & Zhang, X. (2002) · Tetrahedron · doi:10.1016/s0040-4020(02)00432-5 · Cited by 468
Song, H., Bringer, M. R., Tice, J. D., Gerdts, C. J., & Ismagilov, R. F. (2003) · Applied Physics Letters · doi:10.1063/1.1630378 · Cited by 430
Self-citationZheng, B., Tice, J. D., Roach, L. S., & Ismagilov, R. F. (2004) · Angewandte Chemie International Edition · doi:10.1002/anie.200453974 · Cited by 398
Self-citationA Continuous‐Flow Microcapillary Reactor for the Preparation of a Size Series of CdSe Nanocrystals
Yen, B. K. H., Stott, N. E., Jensen, K. F., & Bawendi, M. G. (2003) · Advanced Materials · doi:10.1002/adma.200305162 · Cited by 239
Coupled Composite CdS−CdSe and Core−Shell Types of (CdS)CdSe and (CdSe)CdS Nanoparticles
Tian, Y., Newton, T., Kotov, N. A., Guldi, D. M., & Fendler, J. H. (1996) · The Journal of Physical Chemistry · doi:10.1021/jp951965l · Cited by 234
Design and fabrication of microfluidic devices for multiphase mixing and reaction
Losey, M. W., Jackman, R. J., Firebaugh, S. L., Schmidt, M. A., & Jensen, K. F. (2002) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2002.803416 · Cited by 232
Drop deformation, breakup, and coalescence with compatibilizer
Hu, Y. T., Pine, D. J., & Leal, L. G. (2000) · Physics of Fluids · doi:10.1063/1.870254 · Cited by 227
A Continuous-Flow Capillary Mixing Method to Monitor Reactions on the Microsecond Time Scale
Shastry, M. C. R., Luck, S. D., & Roder, H. (1998) · Biophysical Journal · doi:10.1016/s0006-3495(98)77977-9 · Cited by 216
Efficient Mixing and Reactions within Microfluidic Channels Using Microbead-Supported Catalysts
Seong, G. H., & Crooks, R. M. (2002) · Journal of the American Chemical Society · doi:10.1021/ja020932y · Cited by 193
Microfabricated Multiphase Reactors for the Selective Direct Fluorination of Aromatics
de Mas, N., Günther, A., Schmidt, M. A., & Jensen, K. F. (2003) · Industrial & Engineering Chemistry Research · doi:10.1021/ie020717q · Cited by 185
A Microreactor for the Nitration of Benzene and Toluene
Burns, J. R., & Ramshaw, C. (2002) · Chemical Engineering Communications · doi:10.1080/00986440214585 · Cited by 137
Coalescence during emulsification
Lobo, L. A., & Svereika, A. (2003) · Journal of Colloid and Interface Science · doi:10.1016/s0021-9797(03)00069-9 · Cited by 118
Rise of Liquids and Bubbles in Angular Capillary Tubes
Bico, J., & Quéré, D. (2002) · Journal of Colloid and Interface Science · doi:10.1006/jcis.2001.8106 · Cited by 116
Kamholz, A. E., & Yager, P. (2002) · Sensors and Actuators B Chemical · doi:10.1016/s0925-4005(01)00990-x · Cited by 113
Sondi, I., Siiman, O., Koester, S., & Matijević, E. (2000) · Langmuir · doi:10.1021/la991109r · Cited by 110
Protein nanoparticles formation by supercritical antisolvent with enhanced mass transfer
Chattopadhyay, P., & Gupta, R. B. (2002) · AIChE Journal · doi:10.1002/aic.690480207 · Cited by 109
The effect of slight deformation on droplet coalescence in linear flows
Rother, M. A., & Davis, R. H. (2001) · Physics of Fluids · doi:10.1063/1.1358871 · Cited by 82
Chattopadhyay, P., & Gupta, R. B. (2002) · Industrial & Engineering Chemistry Research · doi:10.1021/ie020205b · Cited by 80
Cited by
Teh, S.-Y., Lin, R., Hung, L.-H., & Lee, A. P. (2008) · Lab on a Chip · doi:10.1039/b715524g · Cited by 2,690
Reactions in Droplets in Microfluidic Channels
Song, H., Chen, D. L., & Ismagilov, R. F. (2006) · Angewandte Chemie International Edition · doi:10.1002/anie.200601554 · Cited by 1,847
Self-citationLab-on-a-chip: microfluidics in drug discovery
Dittrich, P. S., & Manz, A. (2006) · Nature Reviews Drug Discovery · doi:10.1038/nrd1985 · Cited by 1,844
Microfluidic lab-on-a-chip platforms: requirements, characteristics and applications
Mark, D., Haeberle, S., Roth, G., von Stetten, F., & Zengerle, R. (2010) · Chemical Society Reviews · doi:10.1039/b820557b · Cited by 1,647
Control and detection of chemical reactions in microfluidic systems
deMello, A. J. (2006) · Nature · doi:10.1038/nature05062 · Cited by 1,495
Metadata
- Authors
- Shestopalov, I., Tice, J. D., & Ismagilov, R. F.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2004
- Volume
- 4
- Issue
- 4
- Pages
- 316
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2112073512
- Cited by
- 571
- References
- 30
- FWCI
- 19.43
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.