Micro-bioreactor array for controlling cellular microenvironments
Open accessAbstract
High throughput experiments can be used to spatially and temporally investigate the many factors that regulate cell differentiation. We have developed a micro-bioreactor array (MBA) that is fabricated using soft lithography and contains twelve independent micro-bioreactors perfused with culture medium. The MBA enables cultivation of cells that are either attached to substrates or encapsulated in hydrogels, at variable levels of hydrodynamic shear, and with automated image analysis of the expression of cell differentiation markers. The flow and mass transport in the MBA were characterized by computational fluid dynamic (CFD) modeling. The representative MBA configurations were validated using the C2C12 cell line, primary rat cardiac myocytes and human embryonic stem cells (hESCs) (lines H09 and H13). To illustrate the utility of the MBA for controlled studies of hESCs, we established correlations between the expression of smooth muscle actin and cell density for three different flow configurations.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Novel 3D cell culture platforms are being created to better mimic in vivo conditions and are sometimes called spheroid or organoid culture.
“To overcome this limitation, novel 3D cell culture platforms are being created to better mimic in vivo conditions and are sometimes called spheroid or organoid culture, as described below (37,61,84,98,117,118).”
From Modeling physiological events in 2D vs. 3D cell culture (2017) · cites this paper as [37]
Cites
The origins and the future of microfluidics
Whitesides, G. M. (2006) · Nature · doi:10.1038/nature05058 · Cited by 9,687 · see citing works
Soft Lithography in Biology and Biochemistry
Whitesides, G. M., Ostuni, E., Takayama, S., Jiang, X., & Ingber, D. E. (2001) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.3.1.335 · Cited by 2,603 · see citing works
Poly(dimethylsiloxane) as a Material for Fabricating Microfluidic Devices
McDonald, J. C., & Whitesides, G. M. (2002) · Accounts of Chemical Research · doi:10.1021/ar010110q · Cited by 2,463 · see citing works
Tissue Engineering--Current Challenges and Expanding Opportunities
Griffith, L. G., & Naughton, G. K. (2002) · Science · doi:10.1126/science.1069210 · Cited by 2,348 · see citing works
El-Ali, J., Sorger, P. K., & Jensen, K. F. (2006) · Nature · doi:10.1038/nature05063 · Cited by 2,105 · see citing works
Physics and Applications of Microfluidics in Biology
Beebe, D. J., Mensing, G. A., & Walker, G. M. (2002) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.4.112601.125916 · Cited by 1,803 · see citing works
Out of Eden: Stem Cells and Their Niches
Watt, F. M., & Hogan, A. B. L. M. (2000) · Science · doi:10.1126/science.287.5457.1427 · Cited by 1,754 · see citing works
Socializing with the Neighbors
Fuchs, E. V., Tumbar, T., & Guasch, G. (2004) · Cell · doi:10.1016/s0092-8674(04)00255-7 · Cited by 1,711 · see citing works
Patterning proteins and cells using soft lithography
Kane, R. S. (1999) · Biomaterials · doi:10.1016/s0142-9612(99)00165-9 · Cited by 1,492 · see citing works
Radisic, M., Park, H., Shing, H., Consi, T. R., Schöen, F. J., Langer, R., Freed, L. E., & Vunjak‐Novakovic, G. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0407817101 · Cited by 913 · see citing works
Self-citationBryant, S. J., Nuttelman, C. R., & Anseth, K. S. (2000) · Journal of Biomaterials Science Polymer Edition · doi:10.1163/156856200743805 · Cited by 775 · see citing works
Nanoliter-scale synthesis of arrayed biomaterials and application to human embryonic stem cells
Anderson, D. G., Levenberg, S., & Langer, R. (2004) · Nature Biotechnology · doi:10.1038/nbt981 · Cited by 747 · see citing works
Self-citationProbing the role of multicellular organization in three-dimensional microenvironments
Albrecht, D. R., Underhill, G. H., Wassermann, T., Sah, R. L., & Bhatia, S. N. (2006) · Nature Methods · doi:10.1038/nmeth873 · Cited by 553 · see citing works
A microfabricated array bioreactor for perfused 3D liver culture
Powers, M. J., Domanský, K., Mofrad, M. R. K., Kalezi, A., Capitano, A. T., Upadhyaya, A., Kurzawski, P., Wack, K. E., Stolz, D. B., Kamm, R. D., et al. (2002) · Biotechnology and Bioengineering · doi:10.1002/bit.10143 · Cited by 464 · see citing works
A novel 3D mammalian cell perfusion-culture system in microfluidic channels
Toh, Y.-C., Zhang, C., Zhang, J., Khong, Y. M., Chang, S., Samper, V. D., van Noort, D., Hutmacher, D. W., & Yu, H. (2007) · Lab on a Chip · doi:10.1039/b614872g · Cited by 414 · see citing works
Microfluidic Devices for the High-Throughput Chemical Analysis of Cells
McClain, M. A., Culbertson, C. T., Jacobson, S. C., et al. (2003) · Analytical Chemistry · doi:10.1021/ac0346510 · Cited by 381 · see citing works
Controlled, Scalable Embryonic Stem Cell Differentiation Culture
Dang, S. M., Gerecht, S., Chen, J., Itskovitz‐Eldor, J., & Zandstra, P. W. (2004) · Stem Cells · doi:10.1634/stemcells.22-3-275 · Cited by 314 · see citing works
Self-citationMicrofabrication and microfluidics for tissue engineering: state of the art and future opportunities
Andersson, H., & van den Berg, A. (2004) · Lab on a Chip · doi:10.1039/b314469k · Cited by 309 · see citing works
Bioreactor design for tissue engineering
Pörtner, R., Nagel-Heyer, S., Goepfert, C., Adamietz, P., & Meenen, N. M. (2005) · Journal of Bioscience and Bioengineering · doi:10.1263/jbb.100.235 · Cited by 305 · see citing works
Length Control of the Metaphase Spindle
Goshima, G., Wollman, R., Stuurman, N., Scholey, J. M., & Vale, R. D. (2005) · Current Biology · doi:10.1016/j.cub.2005.09.054 · Cited by 266 · see citing works
Synthetic nano-fibrillar extracellular matrices with predesigned macroporous architectures
Zhang, R., & Ma, P. X. (2000) · Journal of Biomedical Materials Research · doi:10.1002/1097-4636(200011)52:2 · Cited by 265 · see citing works
Microfluidic arrays for logarithmically perfused embryonic stem cell culture
Kim, L. Y., Vahey, M. D., Lee, H.-Y., & Joel Voldman, B. (2006) · Lab on a Chip · doi:10.1039/b511718f · Cited by 262 · see citing works
Khademhosseini, A., Yeh, J., Eng, G. M., Karp, J. M., Kaji, H., Borenstein, J. T., Farokhzad, O. C., & Langer, R. (2005) · Lab on a Chip · doi:10.1039/b508096g · Cited by 238 · see citing works
Self-citationGerecht‐Nir, S., Cohen, S., & Itskovitz‐Eldor, J. (2004) · Biotechnology and Bioengineering · doi:10.1002/bit.20045 · Cited by 234 · see citing works
Microfabricated platform for studying stem cell fates
Chin, V. I., Taupin, P., Sanga, S., Scheel, J. R., Gage, F. H., & Bhatia, S. N. (2004) · Biotechnology and Bioengineering · doi:10.1002/bit.20254 · Cited by 202 · see citing works
Gerecht‐Nir, S., Cohen, S., Ziskind, A., et al. (2004) · Biotechnology and Bioengineering · doi:10.1002/bit.20248 · Cited by 182 · see citing works
Dynamic Gene Expression Profiling Using a Microfabricated Living Cell Array
Thompson, D. M., King, K. R., Wieder, K. J., et al. (2004) · Analytical Chemistry · doi:10.1021/ac0354241 · Cited by 170 · see citing works
Design and Fabrication of Topologically Complex, Three-Dimensional Microstructures
Jackman, R. J., Brittain, S. T., Adams, A., et al. (1998) · Science · doi:10.1126/science.280.5372.2089 · Cited by 168 · see citing works
Schofield, R. (1983) · PubMed · Cited by 164 · see citing works
Stem cells and tissue engineering: past, present, and future
POLAK, J. M., & BISHOP, A. E. (2006) · Annals of the New York Academy of Sciences · doi:10.1196/annals.1346.001 · Cited by 155 · see citing works
Gerecht‐Nir, S., Ziskind, A., Cohen, S., et al. (2003) · Laboratory Investigation · doi:10.1097/01.lab.0000106502.41391.f0 · Cited by 155 · see citing works
Chung, C., Mesa, J. M., Randolph, M. A., Yaremchuk, M. J., & Burdick, J. A. (2006) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.30660 · Cited by 147 · see citing works
Self-citationMicrofabricated grooved substrates as platforms for bioartificial liver reactors
Park, J., Francois Berthiaume, B., Toner, M., Yarmush, M. L., & Tilles, A. W. (2005) · Biotechnology and Bioengineering · doi:10.1002/bit.20463 · Cited by 144 · see citing works
A Novel Perfusion Bioreactor Providing a Homogenous Milieu for Tissue Regeneration
Dvir, T., Benishti, N., Shachar, M., & Cohen, S. (2006) · Tissue Engineering · doi:10.1089/ten.2006.12.2843 · Cited by 127 · see citing works
Engineering tissues for in vitro applications
Khetani, S. R., & Bhatia, S. N. (2006) · Current Opinion in Biotechnology · doi:10.1016/j.copbio.2006.08.009 · Cited by 127 · see citing works
Bioreactor cultivation of osteochondral grafts
Vunjak‐Novakovic, G., Meinel, L., Altman, G. H., & Kaplan, D. L. (2005) · Orthodontics and Craniofacial Research · doi:10.1111/j.1601-6343.2005.00334.x · Cited by 120 · see citing works
Self-citationChung, C., Mesa, J. M., Miller, G. J., Randolph, M. A., Gill, T. J., & Burdick, J. A. (2006) · Tissue Engineering · doi:10.1089/ten.2006.12.2665 · Cited by 114 · see citing works
Self-citationKoller, M. R., BENDER, J. G., Miller, W. M., et al. (1993) · Nature Biotechnology · doi:10.1038/nbt0393-358 · Cited by 97 · see citing works
Handheld recirculation system and customized media for microfluidic cell culture
Futai, N., Gu, W. J., Song, J. W., et al. (2005) · Lab on a Chip · doi:10.1039/b510901a · Cited by 96 · see citing works
Influence of inflammatory cells and serum on the performance of implantable glucose sensors
Gerritsen, M., Jansen, J. A., Kros, A., Vriezema, D. M., Sommerdijk, N. A. J. M., Nolte, R. J. M., Lutterman, J. A., van Hövell, S. W. F. M., & van der Gaag, A. (2000) · Journal of Biomedical Materials Research · doi:10.1002/1097-4636(200101)54:1 · Cited by 89 · see citing works
Huang, H., Nakayama, Y., Qin, K., et al. (2005) · Journal of Artificial Organs · doi:10.1007/s10047-005-0291-2 · Cited by 78 · see citing works
Perfusion cultures of human embryonic stem cells
Fong, W. J., Tan, H. L., Choo, A. B. H., et al. (2005) · Bioprocess and Biosystems Engineering · doi:10.1007/s00449-005-0421-5 · Cited by 62 · see citing works
Powell, K. (2005) · Nature · doi:10.1038/435268a · Cited by 55 · see citing works
Moreira, J. L., Santana, P. C., Feliciano, A. S., Cruz, P. E., Racher, A. J., Griffiths, J. B., & Carrondo, M. J. T. (1995) · Biotechnology Progress · doi:10.1021/bp00035a012 · Cited by 53 · see citing works
Practical Aspects of Cardiac Tissue Engineering With Electrical Stimulation
Cannizzaro, C., Tandon, N. M., Figallo, E., Park, H., Gerecht, S., Radisic, M., Elvassore, N., & Vunjak‐Novakovic, G. (2007) · Methods in molecular medicine · doi:10.1007/978-1-59745-443-8_16 · Cited by 46 · see citing works
Self-citationNew radiopaque polyHEMA‐based hydrogel particles
Horák, D., Metalová, M., & Rypáček, F. (1997) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199702)34:2 · Cited by 43 · see citing works
Transport in a Grooved Perfusion Flat-Bed Bioreactor for Cell Therapy Applications
Horner, M., Miller, W. M., Ottino, J. M., et al. (1998) · Biotechnology Progress · doi:10.1021/bp980067e · Cited by 42 · see citing works
Continuous flow separation of particles within an asymmetric microfluidic device
Zhang, X., Cooper, J. M., Monaghan, P. B., et al. (2006) · Lab on a Chip · doi:10.1039/b515272k · Cited by 41 · see citing works
Stem cells: So what's in a niche?
Jones, L. (2001) · Current Biology · doi:10.1016/s0960-9822(01)00288-3 · Cited by 26 · see citing works
Fabrication of Micromachined Magnetic Particle Separators for Bioseparation in Microfluidic Systems
Choi, J. (2006) · Humana Press eBooks · doi:10.1385/1-59259-997-4:65 · Cited by 12 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Modeling physiological events in 2D vs. 3D cell culture
Duval, K., Grover, H., Han, L.-H., Mou, Y., Pegoraro, A. F., Fredberg, J., & Chen, Z. (2017) · Physiology · doi:10.1152/physiol.00036.2016 · Cited by 1,849 · see citing works
Engineered Microenvironments for Controlled Stem Cell Differentiation
Burdick, J. A., & Vunjak-Novakovic, G. (2009) · Tissue Engineering Part A · doi:10.1089/ten.tea.2008.0131 · Cited by 485 · see citing works
Self-citationScalable Stirred-Suspension Bioreactor Culture of Human Pluripotent Stem Cells
Kehoe, D. E., Jing, D., Lock, L. T., & Tzanakakis, E. S. (2010) · Tissue Engineering Part A · doi:10.1089/ten.tea.2009.0454 · Cited by 264 · see citing works
A gel-free 3D microfluidic cell culture system
Ong, S.-M., Zhang, C., Toh, Y.-C., Kim, S. H., Foo, H. L., Tan, C. H., van Noort, D., Park, S., & Yu, H. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.04.022 · Cited by 172 · see citing works
Development and analysis of multi-layer scaffolds for tissue engineering
Papenburg, B. J., Liu, J., Higuera, G. A., Barradas, A. M. C., de Boer, J., van Blitterswijk, C. A., Wessling, M., & Stamatialis, D. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2009.07.057 · Cited by 125 · see citing works
Titmarsh, D. M., Glass, N. R., Mills, R. J., Hidalgo, A., Wolvetang, E. J., Porrello, E. R., Hudson, J. E., & Cooper-White, J. J. (2016) · Scientific Reports · doi:10.1038/srep24637 · Cited by 59 · see citing works
Advances in microfluidic 3D cell culture for preclinical drug development
(2022) · Progress in Molecular Biology and Translational Science · doi:10.1016/bs.pmbts.2021.07.022 · Cited by 23 · see citing works
- Authors
- Figallo, E., Cannizzaro, C., Gerecht, S., Burdick, J. A., Langer, R., Elvassore, N., & Vunjak-Novakovic, G.
- Affiliations
- University of Padua (IT)
- Massachusetts Institute of Technology (US)
- University of Pennsylvania (US)
- Corresponding author
- Elvassore, Nicola
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2007
- Volume
- 7
- Issue
- 6
- Pages
- 710
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W1982220375
- Cited by
- 220
- References
- 50
- Citations by year
- 2025: 2 · 2024: 4 · 2023: 6 · 2022: 6 · 2021: 7 · 2020: 9 · 2019: 3 · 2018: 11 · 2017: 8 · 2016: 7 · 2015: 15 · 2014: 9 · 2013: 19 · 2012: 18
- FWCI
- 17.45
- Type
- journal article
- Language
- en
- Open access
- green
- doi.org
- Locations
- Lab on a Chip (publishedVersion)
- PubMed (publishedVersion)
- Padua Research Archive (University of Padova) (submittedVersion)
- Columbia Academic Commons (Columbia University)
- Funders
- National Institutes of Health (2r01hl076485-16)
- National Heart, Lung, and Blood Institute (R01-HL076485)
- National Institute of Biomedical Imaging and Bioengineering (P41EB002520)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › 3D Printing in Biomedical Research
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Cell Biology › Cellular Mechanics and Interactions
- Keywords
- cell microenvironment, cell differentiation, hydrogel encapsulation, hydrodynamic shear, C2C12 myoblasts, cardiomyocytes, human embryonic stem cells, smooth muscle actin, cell density, computational fluid dynamics, high-throughput cell culture, soft lithography
- MeSH terms
- Actins, Animals, Cell Count, Cell Differentiation, Computer Simulation, Culture Media, Humans, Models, Biological, Muscle, Smooth, Rheology, Cell Culture Techniques, Bioreactors, Tissue Engineering, Myocytes, Cardiac, Shear Strength, Nanotechnology, Rats, Embryonic Stem Cells
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review