The DOI matches its Crossref record; 83 of the 83 references it cites were found in a registry or an index.
Current strategies towards hemocompatible coatings
Abstract
A wide range of biomedical devices is applied clinically in contact with blood. Tailoring the surface properties of the involved biomaterials is a common approach to enhance performance and to limit adverse reactions. This review summarizes current trends in coating technologies developed for that purpose. Inorganic coatings were shown to substantially improve the durability and inertness of biomaterials while a number of advanced polymer coatings were demonstrated to be very effective by targeting specific biochemical pathways. However, to fully utilize the power of these bioactive coatings safety issues need to be thoroughly addressed in future studies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The surface science of titanium dioxide
Diebold, U. (2003) · Surface Science Reports · doi:10.1016/s0167-5729(02)00100-0 · Cited by 7,944
Light-induced amphiphilic surfaces
Wang, R., Hashimoto, K., Fujishima, A., Chikuni, M., Kojima, E., Kitamura, A., Shimohigoshi, M., & Watanabe, T. (1997) · Nature · doi:10.1038/41233 · Cited by 3,384
Gorbet, M. B., & Sefton, M. V. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2004.01.023 · Cited by 1,347
Weitz, J. I., Hudoba, M., Massel, D., Maraganore, J., & Hirsh, J. (1990) · Journal of Clinical Investigation · doi:10.1172/jci114723 · Cited by 1,123
The VIVA Trial: Vascular Endothelial Growth Factor in Ischemia for Vascular Angiogenesis
Henry, T. D., Annex, B. H., McKendall, G. R., Azrin, M. A., Lopez, J. J., Giordano, F. J., Shah, P. K., Willerson, J. T., Benza, R. L., Berman, D. S., et al. (2003) · Circulation · doi:10.1161/01.cir.0000061911.47710.8a · Cited by 1,025
The Structure of a Complex of Recombinant Hirudin and Human α-Thrombin
Rydel, T. J., Ravichandran, K. G., Tulinsky, A., Bode, W., Huber, R., Roitsch, C., & Fenton, J. W. (1990) · Science · doi:10.1126/science.2374926 · Cited by 709
Di Nisio, M., Middeldorp, S., & Büller, H. R. (2005) · New England Journal of Medicine · doi:10.1056/nejmra044440 · Cited by 655
Protein adsorption to poly(ethylene oxide) surfaces
Gombotz, W. R., Guanghui, W., Horbett, T. A., & Hoffman, A. S. (1991) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820251211 · Cited by 634
Endothelial Progenitor Cell Capture by Stents Coated With Antibody Against CD34
Aoki, J., Serruys, P. W., van Beusekom, H., Ong, A. T. L., McFadden, E. P., Sianos, G., van der Giessen, W. J., Regar, E., de Feyter, P. J., Davis, H. R., et al. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.01.048 · Cited by 545
Hedman, M., Hartikainen, J., Syvänne, M., Stjernvall, J., Hedman, A., Kivelä, A., Vanninen, E., Mussalo, H., Kauppila, E., Simula, S., et al. (2003) · Circulation · doi:10.1161/01.cir.0000070540.80780.92 · Cited by 537
Losordo, D. W., Vale, P. R., Hendel, R. C., Milliken, C. E., Fortuin, F. D., Cummings, N., Schatz, R. A., Asahara, T., Isner, J. M., & Kuntz, R. E. (2002) · Circulation · doi:10.1161/01.cir.0000015982.70785.b7 · Cited by 466
Heparin Bonding on Colloidal Graphite Surfaces
Gott, V. L., Whiffen, J. D., & Dutton, R. C. (1963) · Science · doi:10.1126/science.142.3597.1297 · Cited by 457
Larm, O., Larsson, R., & Olsson, P. (1983) · Biomaterials, Medical Devices, and Artificial Organs · doi:10.3109/10731198309118804 · Cited by 437
Molecular basis of biomaterial-mediated foreign body reactions
Hu, W.-J., Eaton, J. W., Ugarova, T. P., & Tang, L. (2001) · Blood · doi:10.1182/blood.v98.4.1231 · Cited by 431
Structure and function of thrombomodulin: a natural anticoagulant
Dittman, W., & Majerus, P. (1990) · Blood · doi:10.1182/blood.v75.2.329.329 · Cited by 411
Serruys, P. W., Emanuelsson, H., van der Giessen, W., Lunn, A. C., Kiemeney, F., Macaya, C., Rutsch, W., Heyndrickx, G., Suryapranata, H., Legrand, V., et al. (1996) · Circulation · doi:10.1161/01.cir.93.3.412 · Cited by 408
Shen, M., Martinson, L., Wagner, M. S., Castner, D. G., Ratner, B. D., & Horbett, T. A. (2002) · Journal of Biomaterials Science, Polymer Edition · doi:10.1163/156856202320253910 · Cited by 296
Inflammation and the Activated Protein C Anticoagulant Pathway
Esmon, C. (2006) · Seminars in Thrombosis and Hemostasis · doi:10.1055/s-2006-939554 · Cited by 249
Maleic Anhydride CopolymersA Versatile Platform for Molecular Biosurface Engineering
Pompe, T., Zschoche, S., Herold, N., Salchert, K., Gouzy, M.-F., Sperling, C., & Werner, C. (2003) · Biomacromolecules · doi:10.1021/bm034071c · Cited by 236
Self-citationIn vitro hemocompatibility testing of biomaterials according to the ISO 10993-4
Seyfert, U. T., Biehl, V., & Schenk, J. (2002) · Biomolecular Engineering · doi:10.1016/s1389-0344(02)00015-1 · Cited by 232
Ishihara, K., Fukumoto, K., Iwasaki, Y., & Nakabayashi, N. (1999) · Biomaterials · doi:10.1016/s0142-9612(98)00206-3 · Cited by 227
Protein repellant silicone surfaces by covalent immobilization of poly(ethylene oxide)
Chen, H., Zhang, Z., Chen, Y., Brook, M. A., & Sheardown, H. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.07.068 · Cited by 223
Volumetric interpretation of protein adsorption: Competition from mixtures and the Vroman effect
Noh, H., & Vogler, E. A. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2006.09.006 · Cited by 214
Titanium with different oxides: in vitro studies of protein adsorption and contact activation
Wälivaara, B., Aronsson, B.-O., Rodahl, M., Lausmaa, J., & Tengvall, P. (1994) · Biomaterials · doi:10.1016/0142-9612(94)90038-8 · Cited by 208
Weitz, J. I., Leslie, B., & Hudoba, M. (1998) · Circulation · doi:10.1161/01.cir.97.6.544 · Cited by 194
Mechanism of Heparin Activation of Antithrombin
Desai, U. R., Petitou, M., Björk, I., & Olson, S. T. (1998) · Journal of Biological Chemistry · doi:10.1074/jbc.273.13.7478 · Cited by 189
Kidane, A. G., Salacinski, H., Tiwari, A., Bruckdorfer, K. R., & Seifalian, A. M. (2004) · Biomacromolecules · doi:10.1021/bm0344553 · Cited by 166
Hansson, K. M., Tosatti, S. G. P., Isaksson, J., Wetterö, J., Textor, M., Lindahl, T. L., & Tengvall, P. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2004.03.036 · Cited by 158
Walluscheck, K. P., Steinhoff, G., Kelm, S., & Haverich, A. (1996) · European Journal of Vascular and Endovascular Surgery · doi:10.1016/s1078-5884(96)80251-6 · Cited by 158
Chitosan based surfactant polymers designed to improve blood compatibility on biomaterials
Sagnella, S. M., & Mai-ngam, K. (2005) · Colloids and Surfaces B Biointerfaces · doi:10.1016/j.colsurfb.2004.07.001 · Cited by 155
Current trends in biocompatibility testing
Kirkpatrick, C. J., Bittinger, F., Wagner, M., Köhler, H., van Kooten, T. G., Klein, C. L., & Otto, M. (1998) · Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine · doi:10.1243/0954411981533845 · Cited by 145
Autologous Human Tissue-Engineered Heart Valves
Mol, A., Rutten, M. C. M., Driessen, N. J. B., et al. (2006) · Circulation · doi:10.1161/circulationaha.105.001123 · Cited by 143
Weber, L. M., He, J., Bradley, B., HASKINS, K. M., & Anseth, K. S. (2005) · Acta Biomaterialia · doi:10.1016/j.actbio.2005.10.005 · Cited by 140
de Wouwer, M. V., Plaisance, S., Vriese, A. D., Waelkens, E., Collen, D., Persson, J., Daha, M. R., & Conway, E. M. (2006) · Journal of Thrombosis and Haemostasis · doi:10.1111/j.1538-7836.2006.02033.x · Cited by 140
In situ conformational analysis of fibrinogen adsorbed on Si surfaces
Tunç, S., Maitz, M. F., Steiner, G. R., Vázquez, L., Pham, M. T., & Salzer, R. (2005) · Colloids and Surfaces B Biointerfaces · doi:10.1016/j.colsurfb.2005.03.004 · Cited by 137
Self-citationWestedt, U., Wittmar, M., Hellwig, M., Hanefeld, P., Greiner, A., Schaper, A., & Kissel, T. (2006) · Journal of Controlled Release · doi:10.1016/j.jconrel.2005.12.012 · Cited by 134
Labarre, D., Vauthier, C., Chauvierre, C., Petri, B., Müller, R., & Chehimi, M. M. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2005.01.019 · Cited by 131
Pan, C., Tang, J., Weng, Y., Wang, J., & Huang, N. (2006) · Journal of Controlled Release · doi:10.1016/j.jconrel.2006.08.023 · Cited by 128
Suggs, L. J., Shive, M. S., Garcia, C. A., Anderson, J. M., & Mikos, A. G. (1999) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199907)46:1<22::aid-jbm3>3.0.co;2-r · Cited by 127
In vitro hemocompatibility of self-assembled monolayers displaying various functional groups
Sperling, C., Schweiss, R., Streller, U., & Werner, C. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2005.04.042 · Cited by 121
Self-citationEndothelial cell seeding of polymeric vascular grafts
Kristin, J. P. (2004) · Frontiers in bioscience · doi:10.2741/1302 · Cited by 118
Zhou, Z., & Meyerhoff, M. E. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2005.04.046 · Cited by 115
Surface modification of biomaterials by plasma immersion ion implantation
Huang, N., Yang, P., Leng, Y. X., Wang, J., Sun, H. L., Chen, J., & Wan, G. (2004) · Surface and Coatings Technology · doi:10.1016/j.surfcoat.2004.04.041 · Cited by 115
Fleser, P. S., Nuthakki, V. K., Malinzak, L. E., Callahan, R. E., Seymour, M. L., Reynolds, M. M., Merz, S. I., Meyerhoff, M. E., Bendick, P. J., Zelenock, G. B., et al. (2004) · Journal of Vascular Surgery · doi:10.1016/j.jvs.2004.07.007 · Cited by 111
Heparin coating of the stent graft — effects on platelets, coagulation and complement activation
Christensen, K., Larsson, R. L., Emanuelsson, H., Elgue, G., & Larsson, A. (2001) · Biomaterials · doi:10.1016/s0142-9612(00)00190-3 · Cited by 107
Massia, S. P., & Hubbell, J. A. (1992) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(19)50210-1 · Cited by 101
Santerre, J. P., ten Hove, P., VanderKamp, N. H., & Brash, J. L. (1992) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820260105 · Cited by 101
Liaw, P. C., Becker, D. L., Stafford, A. R., Fredenburgh, J. C., & Weitz, J. I. (2001) · Journal of Biological Chemistry · doi:10.1074/jbc.m010584200 · Cited by 98
Andersson, J., Sánchez, J., Ekdahl, K. N., Elgue, G., Nilsson, B., & Larsson, R. (2003) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.10104 · Cited by 98
On the blood compatibility of end-point immobilized heparin
Olsson, P., Sánchez, J., Mollnes, T. E., & Riesenfeld, J. (2000) · Journal of Biomaterials Science Polymer Edition · doi:10.1163/156856200744192 · Cited by 89
Endothelial Recovery: The Next Target in Restenosis Prevention
Losordo, D. W., Isner, J. M., & Díaz‐Sandoval, L. J. (2003) · Circulation · doi:10.1161/01.cir.0000071083.31270.c3 · Cited by 89
Sub‐micron texturing for reducing platelet adhesion to polyurethane biomaterials
Milner, K. R., Snyder, A. J., & Siedlecki, C. A. (2005) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.30554 · Cited by 87
Phaneuf, M. D., Berceli, S. A., Bide, M., Quist, W. C., & LoGerfo, F. W. (1997) · Biomaterials · doi:10.1016/s0142-9612(96)00193-7 · Cited by 86
Sperling, C., Salchert, K., Streller, U., & Werner, C. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2003.12.014 · Cited by 84
Self-citationSeifert, B., Romaniuk, P., & Groth, T. (1997) · Biomaterials · doi:10.1016/s0142-9612(97)00079-3 · Cited by 81
Sperling, C., Houška, M., Brynda, E., Streller, U., & Werner, C. (2005) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.30519 · Cited by 79
Self-citationJahangir, A., McClung, W. G., Cornelius, R. M., McCloskey, C. B., Brash, J. L., & Santerre, J. P. (2002) · Journal of Biomedical Materials Research · doi:10.1002/jbm.10033 · Cited by 78
Aldenhoff, Y. B. J., van der Veen, F. H., Woorst, J. T., Habets, J., Poole-Warren, L. A., & Koole, L. H. (2000) · Journal of Biomedical Materials Research · Cited by 78
Microencapsulated human hepatoma (HepG2) cells: In vitro growth and protein release
Uludag, H., & Sefton, M. V. (1993) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820271002 · Cited by 74
Blood Vessels Engineered from Human Cells
Gong, Z., & Niklason, L. E. (2006) · Trends in Cardiovascular Medicine · doi:10.1016/j.tcm.2006.02.006 · Cited by 70
Flow cytometric study of in vitro neutrophil activation by biomaterials
Gorbet, M., Yeo, E. L., & Sefton, M. V. (1999) · Journal of Biomedical Materials Research · Cited by 69
Endothelialization of Microporous YIGSR/PEG-Modified Polyurethaneurea
Jun, H., & West, J. L. (2005) · Tissue Engineering · doi:10.1089/ten.2005.11.1133 · Cited by 68
Videm, V., Mollnes, T. E., Bergh, K., Fosse, E. T., Mohr, B., Hagve, T., Aasen, A. O., & Svennevig, J. L. (1999) · Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/s0022-5223(99)70302-8 · Cited by 66
Videm, V., Mollnes, T. E., Fosse, E. T., et al. (1999) · Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/s0022-5223(99)70301-6 · Cited by 60
Clarotti, G., Schué, F., Sledz, J., Aoumar, A. A. B., Geckeler, K. E., Orsetti, A., & Paleirac, G. (1992) · Biomaterials · doi:10.1016/0142-9612(92)90176-o · Cited by 60
In Vivo Assessment of a Novel Dacron Surface with Covalently Bound Recombinant Hirudin
Wyers, M. C., Phaneuf, M. D., Rzucidlo, E. M., Contreras, M., LoGerfo, F. W., & Quist, W. C. (1999) · Cardiovascular Pathology · doi:10.1016/s1054-8807(99)00005-8 · Cited by 58
Gorbet, M., & Sefton, M. V. (2001) · Journal of Laboratory and Clinical Medicine · doi:10.1067/mlc.2001.114677 · Cited by 57
Biodegradable membrane‐covered stent from chitosan‐based polymers
Thierry, B., Merhi, Y., Silver, J., & Tabrizian, M. (2005) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.30450 · Cited by 57
Cao, L., Sukavaneshvar, S., Ratner, B. D., & Horbett, T. A. (2006) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.30908 · Cited by 53
In vitro blood reactivity to hydroxylated and non-hydroxylated polymer surfaces
Sperling, C., Maitz, M. F., Talkenberger, S., Gouzy, M.-F., Groth, T., & Werner, C. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.04.041 · Cited by 53
Self-citationIn vitro cytotoxicity of nitric oxide-releasing sol–gel derived materials
Nablo, B. J., & Schoenfisch, M. H. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.11.015 · Cited by 51
Arica, M. Y., Bayramoğlu, G., Arıca, B., Yalçın, E., Ito, K., & Yağcı, Y. (2005) · Macromolecular Bioscience · doi:10.1002/mabi.200500091 · Cited by 46
The scientific basis for selection of measures of thrombogenicity.
Lane, D. A., & Sk, B. (1994) · PubMed · Cited by 41
Maitz, M. F., & Shevchenko, N. (2005) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.30526 · Cited by 40
Self-citationMeasuring the degree of plasma contact activation induced by artificial materials
Sánchez, J., Lundquist, P. B., Elgue, G., et al. (2002) · Thrombosis Research · doi:10.1016/s0049-3848(02)00051-8 · Cited by 39
Mechanism of the participation of the contact system in the Vroman effect. Review and summary
Scott, C. F. (1991) · Journal of Biomaterials Science Polymer Edition · doi:10.1080/09205063.1991.9756658 · Cited by 37
Heparin-bonded surfaces in extracorporeal membrane oxygenation for cardiac support
von Segesser, L. K. (1996) · The Annals of Thoracic Surgery · doi:10.1016/0003-4975(95)01011-4 · Cited by 34
Surface Modification of Titanium Based Biomaterials by Ion Beam
Xianghuai, L., Zheng, Z., Zhuyao, Z., Nan, H., Ping, Y., Cai, G., & Yuanru, C. (1996) · Journal of Biomaterials Applications · doi:10.1177/088532829601000403 · Cited by 32
Immobilization of human thrombomodulin on glass beads and its anticoagulant activity
Akashi, M., Maruyama, I., Fukudome, N., & Yashima, E. (1992) · Bioconjugate Chemistry · doi:10.1021/bc00017a002 · Cited by 32
A novel textured surface for blood-contact
Fujisawa, N., Poole-Warren, L. A., Woodard, J. C., Bertram, C., & Schindhelm, K. (1999) · Biomaterials · doi:10.1016/s0142-9612(98)00251-8 · Cited by 32
Review paper: Principles and Applications of Surface Analytical Techniques at the Vascular Interface
Kannan, R. Y., Salacinski, H. J., Vara, D. S., Odlyha, M., & Seifalian, A. M. (2006) · Journal of Biomaterials Applications · doi:10.1177/0885328206065728 · Cited by 26
Berceli, S. A., Phaneuf, M. D., & LoGerfo, F. W. (1998) · Journal of Vascular Surgery · doi:10.1016/s0741-5214(98)70014-x · Cited by 21
Improved biocompatability of silicone rubber by removal of surface entrapped air nuclei
KALMAN, P. G., Ward, C. A., McKeown, N. B., McCullough, D., & Romaschin, A. D. (1991) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820250207 · Cited by 20
Cited by
Advances in polymers for anti-biofouling surfaces
Krishnan, S., Weinman, C. J., & Ober, C. K. (2008) · Journal of Materials Chemistry · doi:10.1039/b801491d · Cited by 824
A bioinspired omniphobic surface coating on medical devices prevents thrombosis and biofouling
Leslie, D. C., Waterhouse, A., Berthet, J. B., Valentin, T. M., Watters, A. L., Jain, A., Kim, P., Hatton, B. D., Nedder, A., Donovan, K., et al. (2014) · Nature Biotechnology · doi:10.1038/nbt.3020 · Cited by 758
Metwally, S., & Stachewicz, U. (2019) · Materials Science and Engineering: C · doi:10.1016/j.msec.2019.109883 · Cited by 382
Surface modification of biomaterials and biomedical devices using additive manufacturing
Bose, S., Robertson, S. F., & Bandyopadhyay, A. (2018) · Acta Biomaterialia · doi:10.1016/j.actbio.2017.11.003 · Cited by 305
Polysaccharide biomaterials for drug delivery and regenerative engineering
Shelke, N. B., James, R., Laurencin, C. T., & Kumbar, S. G. (2014) · Polymers for Advanced Technologies · doi:10.1002/pat.3266 · Cited by 281
Metadata
- Authors
- Werner, C., Maitz, M. F., & Sperling, C.
- Venue
- Journal of Materials Chemistry
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2007
- Volume
- 17
- Issue
- 32
- Pages
- 3376
- ISSN
- 0959-9428 (ISSN-L)
- 1364-5501
- OpenAlex
- W2008510868
- Cited by
- 258
- References
- 83
- FWCI
- 6.24
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.