The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Microfluidic large-scale integration on a chip for mass production of monodisperse droplets and particles
Abstract
In this study, we report the mass production of monodisperse emulsion droplets and particles using microfluidic large-scale integration on a chip. The production module comprises a glass microfluidic chip with planar microfabricated 16-256 droplet-formation units (DFUs) and a palm-sized stainless steel holder having several layers for supplying liquids into the inlets of the mounted chip. By using a module having 128 cross-junctions (i.e., 256 DFUs) arranged circularly on a 4 cm x 4 cm chip, we could produce droplets of photopolymerizable acrylate monomer at a throughput of 320.0 mL h(-1). The product was monodisperse, having a mean diameter of 96.4 microm, with a coefficient of variation (CV) of 1.3%. Subsequent UV polymerization off the module yielded monodisperse acrylic microspheres at a throughput of approximately 0.3 kg h(-1). Another module having 128 co-flow geometries could produce biphasic Janus droplets of black and white segments at 128.0 mL h(-1). The product had a mean diameter of 142.3 microm, with a CV of 3.3%. This co-flow module could also be applied in the mass production of homogeneous monomer droplets.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Engineering Flows in Small Devices: Microfluidics Toward a Lab-on-a-Chip
Stone, H. A., Stroock, A. D., & Ajdari, A. (2004) · Annual Review of Fluid Mechanics · doi:10.1146/annurev.fluid.36.050802.122124 · Cited by 3,666
Monodisperse Double Emulsions Generated from a Microcapillary Device
Utada, A. S., Lorenceau, E., Link, D. R., Kaplan, P. D., Stone, H. A., & Weitz, D. A. (2005) · Science · doi:10.1126/science.1109164 · Cited by 2,248
Reactions in Droplets in Microfluidic Channels
Song, H., Chen, D. L., & Ismagilov, R. F. (2006) · Angewandte Chemie International Edition · doi:10.1002/anie.200601554 · Cited by 1,847
Controlled microfluidic interfaces
Atencia, J., & Beebe, D. J. (2005) · Nature · doi:10.1038/nature04163 · Cited by 1,006
Xu, S., Nie, Z., Seo, M., Lewis, P., Kumacheva, E., Stone, H. A., Garstecki, P., Weibel, D. B., Gitlin, I., & Whitesides, G. M. (2005) · Angewandte Chemie International Edition · doi:10.1002/anie.200462226 · Cited by 830
Microreactors: New Technology for Modern Chemistry
Ehrfeld, W., Hessel, V., & Löwe, H. (2000) · Wiley eBooks · doi:10.1002/3527601953 · Cited by 778
Nisisako, T., Torii, T., Takahashi, T., & Takizawa, Y. (2006) · Advanced Materials · doi:10.1002/adma.200502431 · Cited by 724
Self-citationNie, Z., Li, W., Seo, M., Xu, S., & Kumacheva, E. (2006) · Journal of the American Chemical Society · doi:10.1021/ja060882n · Cited by 689
Okushima, S., Nisisako, T., Torii, T., & Higuchi, T. (2004) · Langmuir · doi:10.1021/la0480336 · Cited by 656
Self-citationDroplet formation in a microchannel network
Nisisako, T., Torii, T., & Higuchi, T. (2002) · Lab Chip · doi:10.1039/b108740c · Cited by 607
Self-citationShestopalov, I., Tice, J. D., & Ismagilov, R. F. (2004) · Lab on a Chip · doi:10.1039/b403378g · Cited by 571
Polymer Particles with Various Shapes and Morphologies Produced in Continuous Microfluidic Reactors
Nie, Z., Xu, S., Seo, M., Lewis, P. C., & Kumacheva, E. (2005) · Journal of the American Chemical Society · doi:10.1021/ja042494w · Cited by 531
Controlled Synthesis of Nonspherical Microparticles Using Microfluidics
Dendukuri, D., Tsoi, K., Hatton, T. A., & Doyle, P. S. (2005) · Langmuir · doi:10.1021/la047368k · Cited by 482
Hung, L.-H., Choi, K. M., Tseng, W.-Y., Tan, Y.-C., Shea, K. J., & Lee, A. P. (2006) · Lab on a Chip · doi:10.1039/b513908b · Cited by 392
Droplet Control for Microfluidics
Joanicot, M., & Ajdari, A. (2005) · Science · doi:10.1126/science.1112615 · Cited by 379
An Axisymmetric Flow‐Focusing Microfluidic Device
Takeuchi, S., Garstecki, P., Weibel, D. B., & Whitesides, G. M. (2005) · Advanced Materials · doi:10.1002/adma.200401738 · Cited by 370
Novel microreactors for functional polymer beads
Nisisako, T., Torii, T., & Higuchi, T. (2004) · Chemical Engineering Journal · doi:10.1016/j.cej.2003.11.019 · Cited by 346
Self-citationMiniaturising the laboratory in emulsion droplets
Griffiths, A. D., & Tawfik, D. S. (2006) · Trends in Biotechnology · doi:10.1016/j.tibtech.2006.06.009 · Cited by 346
Controlled formulation of monodisperse double emulsions in a multiple-phase microfluidic system
Nisisako, T., Okushima, S., & Torii, T. (2005) · Soft Matter · doi:10.1039/b501972a · Cited by 335
Self-citationZheng, B., Tice, J. D., & Ismagilov, R. F. (2004) · Analytical Chemistry · doi:10.1021/ac0495743 · Cited by 321
Microfluidic Assembly of Homogeneous and Janus Colloid-Filled Hydrogel Granules
Shepherd, R. F., Conrad, J. C., Rhodes, S. K., Link, D. R., Marquez, M., Weitz, D. A., & Lewis, J. A. (2006) · Langmuir · doi:10.1021/la060759+ · Cited by 273
Microfluidic consecutive flow-focusing droplet generators
Seo, M., Paquet, C., Nie, Z., Xu, S., & Kumacheva, E. (2007) · Soft Matter · doi:10.1039/b700687j · Cited by 263
Martín‐Banderas, L., Flores‐Mosquera, M., Riesco‐Chueca, P., Rodríguez‐Gil, A., Cebolla, Á., Chávez, S., & Gañán‐Calvo, A. M. (2005) · Small · doi:10.1002/smll.200500087 · Cited by 206
Polymer chemistry in flow: New polymers, beads, capsules, and fibers
Steinbacher, J. L., & McQuade, D. T. (2006) · Journal of Polymer Science Part A Polymer Chemistry · doi:10.1002/pola.21630 · Cited by 119
Multiphase flows in microfluidics
Baroud, C. N., & Willaime, H. (2004) · Comptes Rendus Physique · doi:10.1016/j.crhy.2004.04.006 · Cited by 101
The potential of micromixers for contacting of disperse liquid phases
Haverkamp, V., Ehrfeld, W., Gebauer, K., Hessel, V., Löwe, H., Richter, T., & Wille, C. (1999) · Fresenius Journal of Analytical Chemistry · doi:10.1007/s002160051397 · Cited by 96
Cited by
Cambié, D., Bottecchia, C., Straathof, N. J. W., Hessel, V., & Noël, T. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00707 · Cited by 1,502
Hydrogel microparticles for biomedical applications
Daly, A. C., Riley, L., Segura, T., & Burdick, J. A. (2019) · Nature Reviews Materials · doi:10.1038/s41578-019-0148-6 · Cited by 1,249
Passive and active droplet generation with microfluidics: a review
Zhu, P., & Wang, L. (2017) · Lab on a Chip · doi:10.1039/c6lc01018k · Cited by 1,238
Seemann, R., Brinkmann, M., Pfohl, T., & Herminghaus, S. (2012) · Reports on Progress in Physics · doi:10.1088/0034-4885/75/1/016601 · Cited by 1,049
Advanced materials and processing for drug delivery: The past and the future
Zhang, Y., Chan, H. F., & Leong, K. W. (2013) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2012.10.003 · Cited by 1,000
Metadata
- Authors
- Nisisako, T., & Torii, T.
- Venue
- Lab Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2008
- Volume
- 8
- Issue
- 2
- Pages
- 287-293
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2012874220
- Cited by
- 415
- References
- 26
- FWCI
- 14.63
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.