Managing evaporation for more robust microscale assays : Part 1. Volume loss in high throughput assays
Open accessThe DOI matches its Crossref record; 49 of the 49 references it cites were found in a registry or an index.
Abstract
Evaporation is a well known issue when handling small liquid volumes. Here we present a review of microscale assays prone to evaporation and methods to make them more robust. Applications for these assays span from combinatorial chemistry to cell-biology where the stability of concentrations and osmolarity can be critical. A dimensionless evaporation number Ev is presented and used to characterize volume loss in short term and long term microscale assays. Ev can be used both as a design tool and as an analysis parameter. The advantageous use of evaporation in some applications is also discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“Rapid evaporation in microtiter plates is an acknowledged issue [41, 42].”
From The role of Raman spectroscopy in biopharmaceuticals from development to manufacturing (2022) · cites this paper as [42]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Capillary flow as the cause of ring stains from dried liquid drops
Deegan, R. D., Bakajin, O., Dupont, T. F., Huber, G., Nagel, S. R., & Witten, T. A. (1997) · Nature · doi:10.1038/39827 · Cited by 6,435
Microfluidics: Fluid physics at the nanoliter scale
Squires, T. M., & Quake, S. R. (2005) · Reviews of Modern Physics · doi:10.1103/revmodphys.77.977 · Cited by 4,379
Fabrication of microfluidic systems in poly(dimethylsiloxane)
McDonald, J. C., Duffy, D. C., Anderson, J. R., Chiu, D. T., Wu, H., Schueller, O. J. A., & Whitesides, G. M. (2000) · Electrophoresis · doi:10.1002/(sici)1522-2683(20000101)21:1<27::aid-elps27>3.0.co;2-c · Cited by 3,329
Contact line deposits in an evaporating drop
Deegan, R. D., Bakajin, O., Dupont, T. F., Huber, G., Nagel, S. R., & Witten, T. A. (2000) · Physical Review E · doi:10.1103/physreve.62.756 · Cited by 2,300
Berg, H. C., & Purcell, E. M. (1977) · Biophysical Journal · doi:10.1016/s0006-3495(77)85544-6 · Cited by 1,758
Cho, S. K., Moon, H., & Kim, C.-J. (2003) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2002.807467 · Cited by 1,598
Vali, G. (1971) · Journal of the Atmospheric Sciences · doi:10.1175/1520-0469(1971)028<0402:qeoera>2.0.co;2 · Cited by 852
A passive pumping method for microfluidic devices
Walker, G. M., & Beebe, D. J. (2002) · Lab on a Chip · doi:10.1039/b204381e · Cited by 420
Self-citationFlow and Fracture in Drying Nanoparticle Suspensions
Dufresne, E. R., Corwin, E. I., Greenblatt, N. A., Ashmore, J., Wang, D. Y., Dinsmore, A. D., Cheng, J. X., Xie, X. S., Hutchinson, J. W., & Weitz, D. A. (2003) · Physical Review Letters · doi:10.1103/physrevlett.91.224501 · Cited by 326
Jackman, R. J., Duffy, D. C., Ostuni, E., Willmore, N. D., & Whitesides, G. M. (1998) · Analytical Chemistry · doi:10.1021/ac971295a · Cited by 304
Research works printed but not linked: 3
- Litborn E, Emmer A, Roeraade J. Electrophoresis. 2000;21:91–99. doi: 10.1002/(SICI)1522-2683(20000101)21:1<91::AID-ELPS91>3.0.CO;2-Y. [DOI] [PubMed] [Google Scholar] · doi:10.1002/(sici)1522-2683(20000101)21:1<91::aid-elps91>3.0.co;2-y
- Poulard C, Guena G, Cazabat AM. J Phys: Condens Matter. 2005;17:S4213–S4227. [Google Scholar]
- Duguid HA, Stampfer JF. J Atmos Sci. 1971;28:1233. [Google Scholar] · doi:10.1175/1520-0469(1971)028
Cited by
The present and future role of microfluidics in biomedical research
Sackmann, E. K., Fulton, A. L., & Beebe, D. J. (2014) · Nature · doi:10.1038/nature13118 · Cited by 2,995
Self-citationEngineers are from PDMS-land, Biologists are from Polystyrenia
Berthier, E., Young, E. W. K., & Beebe, D. (2012) · Lab on a Chip · doi:10.1039/c2lc20982a · Cited by 799
Self-citationFundamentals of microfluidic cell culture in controlled microenvironments
Young, E. W. K., & Beebe, D. J. (2010) · Chemical Society Reviews · doi:10.1039/b909900j · Cited by 615
Self-citationLecault, V., VanInsberghe, M., Sekulovic, S., Knapp, D. J. H. F., Wohrer, S., Bowden, W., Viel, F., McLaughlin, T., Jarandehei, A., Miller, M., et al. (2011) · Nature Methods · doi:10.1038/nmeth.1614 · Cited by 335
Droplet Microarrays: From Surface Patterning to High‐Throughput Applications
Feng, W., Ueda, E., & Levkin, P. A. (2018) · Advanced Materials · doi:10.1002/adma.201706111 · Cited by 246
Metadata
- Authors
- Berthier, E., Warrick, J., Yu, H., & Beebe, D. J.
- Affiliations
- University of Canterbury (NZ)
- University of Wisconsin–Madison (US)
- Corresponding author
- Beebe, David J.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2008
- Volume
- 8
- Issue
- 6
- Pages
- 852
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- PMC
- PMC2453240
- OpenAlex
- W2076407216
- Cited by
- 114
- References
- 47
- Citations by year
- 2026: 1 · 2025: 4 · 2024: 1 · 2023: 8 · 2022: 3 · 2021: 8 · 2020: 3 · 2019: 5 · 2018: 7 · 2017: 6 · 2016: 7 · 2015: 4 · 2014: 5 · 2013: 10 · 2012: 11
- FWCI
- 0.79
- Type
- journal article
- Language
- en
- Open access
- green
- europepmc.org
- Locations
- Lab on a Chip (publishedVersion)
- PubMed (publishedVersion)
- Europe PMC (PubMed Central) (acceptedVersion)
- PubMed Central (acceptedVersion)
- Funders
- MacDiarmid Institute for Advanced Materials and Nanotechnology
- National Cancer Institute (K25CA104162, R21CA122672)
- U.S. National Library of Medicine (T15LM007359)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Physical Sciences › Chemical Engineering › Fluid Flow and Transfer Processes › Innovative Microfluidic and Catalytic Techniques Innovation
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrowetting and Microfluidic Technologies
- Keywords
- evaporation, volume loss, high-throughput screening, combinatorial chemistry, osmolarity, assay robustness
- MeSH terms
- Autoanalysis, Biological Assay, Biology, Cell Physiological Phenomena, Miniaturization, Volatilization, Reproducibility of Results, Combinatorial Chemistry Techniques, Microfluidic Analytical Techniques
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.