Managing evaporation for more robust microscale assays : Part 1. Volume loss in high throughput assays
Open accessThe DOI matches its Crossref record; 49 of the 49 references it cites were found in a registry or an index.
Abstract
Evaporation is a well known issue when handling small liquid volumes. Here we present a review of microscale assays prone to evaporation and methods to make them more robust. Applications for these assays span from combinatorial chemistry to cell-biology where the stability of concentrations and osmolarity can be critical. A dimensionless evaporation number Ev is presented and used to characterize volume loss in short term and long term microscale assays. Ev can be used both as a design tool and as an analysis parameter. The advantageous use of evaporation in some applications is also discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“Rapid evaporation in microtiter plates is an acknowledged issue [41, 42].”
From The role of Raman spectroscopy in biopharmaceuticals from development to manufacturing (2022) · cites this paper as [42]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Capillary flow as the cause of ring stains from dried liquid drops
Deegan, R. D., Bakajin, O., Dupont, T. F., Huber, G., Nagel, S. R., & Witten, T. A. (1997) · Nature · doi:10.1038/39827 · Cited by 6,435
Microfluidics: Fluid physics at the nanoliter scale
Squires, T. M., & Quake, S. R. (2005) · Reviews of Modern Physics · doi:10.1103/revmodphys.77.977 · Cited by 4,379
Fabrication of microfluidic systems in poly(dimethylsiloxane)
McDonald, J. C., Duffy, D. C., Anderson, J. R., Chiu, D. T., Wu, H., Schueller, O. J. A., & Whitesides, G. M. (2000) · Electrophoresis · doi:10.1002/(sici)1522-2683(20000101)21:1<27::aid-elps27>3.0.co;2-c · Cited by 3,329
Contact line deposits in an evaporating drop
Deegan, R. D., Bakajin, O., Dupont, T. F., Huber, G., Nagel, S. R., & Witten, T. A. (2000) · Physical Review E · doi:10.1103/physreve.62.756 · Cited by 2,300
Berg, H. C., & Purcell, E. M. (1977) · Biophysical Journal · doi:10.1016/s0006-3495(77)85544-6 · Cited by 1,758
Cho, S. K., Moon, H., & Kim, C.-J. (2003) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2002.807467 · Cited by 1,598
Vali, G. (1971) · Journal of the Atmospheric Sciences · doi:10.1175/1520-0469(1971)028<0402:qeoera>2.0.co;2 · Cited by 852
A passive pumping method for microfluidic devices
Walker, G. M., & Beebe, D. J. (2002) · Lab on a Chip · doi:10.1039/b204381e · Cited by 420
Self-citationFlow and Fracture in Drying Nanoparticle Suspensions
Dufresne, E. R., Corwin, E. I., Greenblatt, N. A., Ashmore, J., Wang, D. Y., Dinsmore, A. D., Cheng, J. X., Xie, X. S., Hutchinson, J. W., & Weitz, D. A. (2003) · Physical Review Letters · doi:10.1103/physrevlett.91.224501 · Cited by 326
Jackman, R. J., Duffy, D. C., Ostuni, E., Willmore, N. D., & Whitesides, G. M. (1998) · Analytical Chemistry · doi:10.1021/ac971295a · Cited by 304
Evaporation of Microdroplets and the Wetting of Solid Surfaces
Rowan, S. M., Newton, M. I., & McHale, G. (1995) · The Journal of Physical Chemistry · doi:10.1021/j100035a034 · Cited by 293
Heo, Y. S., Cabrera, L. M., Song, J. W., Futai, N., Tung, Y.-C., Smith, G. D., & Takayama, S. (2007) · Analytical Chemistry · doi:10.1021/ac061990v · Cited by 245
Su, F., Chakrabarty, K., & Fair, R. B. (2006) · IEEE Transactions on Computer-Aided Design of Integrated Circuits and Systems · doi:10.1109/tcad.2005.855956 · Cited by 231
Micro total analysis system (�-TAS) in biotechnology
Lee, S. J., & Lee, S. Y. (2004) · Applied Microbiology and Biotechnology · doi:10.1007/s00253-003-1515-0 · Cited by 222
Evaporation and the Wetting of a Low-Energy Solid Surface
McHale, G., Rowan, S. M., Newton, M. I., & Banerjee, M. K. (1998) · The Journal of Physical Chemistry B · doi:10.1021/jp972552i · Cited by 193
Flow rate analysis of a surface tension driven passive micropump
Berthier, E., & Beebe, D. J. (2007) · Lab on a Chip · doi:10.1039/b707637a · Cited by 191
Self-citationAutomated cell culture in high density tubeless microfluidic device arrays
Meyvantsson, I., Warrick, J. W., Hayes, S., Skoien, A., & Beebe, D. J. (2008) · Lab on a Chip · doi:10.1039/b715375a · Cited by 172
Self-citationCharacterization of an Inkjet Chemical Microdispenser for Combinatorial Library Synthesis
Lemmo, A. V., Fisher, J. T., Geysen, H. M., & Rose, D. J. (1997) · Analytical Chemistry · doi:10.1021/ac960808v · Cited by 148
Electrochemical Analysis in Picoliter Microvials
Clark, R. A., Hietpas, P. B., & Ewing, A. G. (1997) · Analytical Chemistry · doi:10.1021/ac960559a · Cited by 117
An evaporation-based microfluidic sample concentration method
Walker, G. M., & Beebe, D. J. (2002) · Lab on a Chip · doi:10.1039/b202473j · Cited by 106
Self-citationMicromachining Sensors for Electrochemical Measurement in Subnanoliter Volumes
Bratten, C. D. T., Cobbold, P. H., & Cooper, J. M. (1997) · Analytical Chemistry · doi:10.1021/ac960743w · Cited by 100
Continuous flow in open microfluidics using controlled evaporation
Zimmermann, M., Bentley, S., Schmid, H., Hunziker, P., & Delamarche, E. (2005) · Lab on a Chip · doi:10.1039/b510044e · Cited by 85
Satoh, W., Hosono, H., & Suzuki, H. R. (2005) · Analytical Chemistry · doi:10.1021/ac050821s · Cited by 84
Evaporation driven pumping for chromatography application
Goedecke, N., Eijkel, J. C. T., & Manz, A. (2002) · Lab on a Chip · doi:10.1039/b208031c · Cited by 83
Diffusion-driven evaporation of sessile drops
Poulard, C., Guéna, G., & Cazabat, A. M. (2005) · Journal of Physics Condensed Matter · doi:10.1088/0953-8984/17/49/015 · Cited by 69
An Evaporation-Based Disposable Micropump Concept for Continuous Monitoring Applications
Effenhauser, C. S., Harttig, H., & Krämer, P. (2002) · Biomedical Microdevices · doi:10.1023/a:1014215728074 · Cited by 64
Micro-evaporation electrolyte concentrator
Timmer, B. H., van Delft, K. M., Olthuis, W., Bergveld, P., & van den Berg, A. (2003) · Sensors and Actuators B Chemical · doi:10.1016/s0925-4005(03)00108-4 · Cited by 63
Water in micro- and nanofluidics systems described using the water potential
Eijkel, J. C. T., & van den Berg, A. (2005) · Lab on a Chip · doi:10.1039/b509819j · Cited by 60
Transpiration-based micropump for delivering continuous ultra-low flow rates
Namasivayam, V., Larson, R. G., Burke, D., & Burns, M. A. (2003) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/13/2/314 · Cited by 54
How Does Water Ascend in Tall Trees and Other Vascular Plants?
Zimmermann, U. S. (1995) · Annals of Botany · doi:10.1006/anbo.1995.1131 · Cited by 54
Berthier, E., Warrick, J., Yu, H., & Beebe, D. J. (2008) · Lab on a Chip · doi:10.1039/b717423c · Cited by 53
Self-citationDiffusional microtitration: acid/base titrations in pico- and femtoliter samples
Gratzl, M., & Chen, Y. (1993) · Analytical Chemistry · doi:10.1021/ac00063a025 · Cited by 52
Wikswo, J. P., Prokop, A., Baudenbacher, F., Cliffel, D., Csukas, B., & Velkovsky, M. (2006) · IEE Proceedings - Nanobiotechnology · doi:10.1049/ip-nbt:20050045 · Cited by 51
Hu, G., & Li, D. (2007) · Biomedical Microdevices · doi:10.1007/s10544-006-9035-1 · Cited by 48
Lauffenburger, D. A., & Cozens-Roberts, C. (1989) · Biotechnology and Bioengineering · doi:10.1002/bit.260331102 · Cited by 46
Parallel reactions in open chip-based nanovials with continuous compensation for solvent evaporation
Litborn, E., Emmer, Å., & Roeraade, J. (2000) · Electrophoresis · Cited by 42
Chip-based nanovials for tryptic digest and capillary electrophoresis
Litborn, E., Emmer, Å., & Roeraade, J. (1999) · Analytica Chimica Acta · doi:10.1016/s0003-2670(99)00486-9 · Cited by 36
Ultrathin Slab Gel Separations of DNA Using a Single Capillary Sample Introduction System
Hietpas, P. B., Bullard, K. M., Gutman, D. A., & Ewing, A. G. (1997) · Analytical Chemistry · doi:10.1021/ac970070x · Cited by 33
Hietpas, P. B., & Ewing, A. G. (1995) · Journal of Liquid Chromatography · doi:10.1080/10826079508014611 · Cited by 33
Evaporation-induced solvent migration in electrically-driven thin layer chromatography
Shafik, T., Howard, A. G., Moffatt, F., & Wilson, I. D. (1999) · Journal of Chromatography A · doi:10.1016/s0021-9673(99)00269-1 · Cited by 31
The Evaporation Rates of Small, Freely Falling Water Drops
Duguid, H. A., & STAMPFER, J. F. (1971) · Journal of the Atmospheric Sciences · Cited by 31
Evaporation of small water drops maintained at constant volume
Peiss, C. N. (1989) · Journal of Applied Physics · doi:10.1063/1.343165 · Cited by 30
Liquid lid for biochemical reactions in chip-based nanovials
Litborn, E., & Roeraade, J. (2000) · Journal of Chromatography B Biomedical Sciences and Applications · doi:10.1016/s0378-4347(00)00037-2 · Cited by 29
Neugebauer, S., Evans, S. R., Aguilar, Z. P., Mosbach, M., Fritsch, I., & Schuhmann, W. W. (2003) · Analytical Chemistry · doi:10.1021/ac0346860 · Cited by 29
Diffusional Microtitration: Reagent Delivery by a Diffusional Microburet into Microscopic Samples
Chen, Y., & Gratzl, M. (1994) · Analytical Chemistry · doi:10.1021/ac00085a009 · Cited by 26
Kuz, V. A. (1991) · Journal of Applied Physics · doi:10.1063/1.347643 · Cited by 22
Reliability Considerations for the BioMEMS Designer
Pan, J. (2004) · Proceedings of the IEEE · doi:10.1109/jproc.2003.820532 · Cited by 19
Approximations for diffusion from a disc source
Warrick, A. W., Broadbridge, P., & Lomen, D. O. (1992) · Applied Mathematical Modelling · doi:10.1016/0307-904x(92)90067-d · Cited by 17
Mayer, G., & Köhler, J. M. (1997) · Sensors and Actuators A Physical · doi:10.1016/s0924-4247(97)01354-x · Cited by 16
Research works printed but not linked: 3
- Litborn, 2000, Electrophoresis, 21, 91, 10.1002/(SICI)1522-2683(20000101)21:1<91::AID-ELPS91>3.0.CO;2-Y · doi:10.1002/(sici)1522-2683(20000101)21:1<91::aid-elps91>3.0.co;2-y
- Poulard, 2005, J. Phys.: Condens. Matter, 17, S4213
- Duguid, 1971, J. Atmos. Sci., 28, 1233, 10.1175/1520-0469(1971)028<1233:TEROSF>2.0.CO;2 · doi:10.1175/1520-0469(1971)028
Cited by
The present and future role of microfluidics in biomedical research
Sackmann, E. K., Fulton, A. L., & Beebe, D. J. (2014) · Nature · doi:10.1038/nature13118 · Cited by 2,995
Self-citationEngineers are from PDMS-land, Biologists are from Polystyrenia
Berthier, E., Young, E. W. K., & Beebe, D. (2012) · Lab on a Chip · doi:10.1039/c2lc20982a · Cited by 799
Self-citationFundamentals of microfluidic cell culture in controlled microenvironments
Young, E. W. K., & Beebe, D. J. (2010) · Chemical Society Reviews · doi:10.1039/b909900j · Cited by 615
Self-citationLecault, V., VanInsberghe, M., Sekulovic, S., Knapp, D. J. H. F., Wohrer, S., Bowden, W., Viel, F., McLaughlin, T., Jarandehei, A., Miller, M., et al. (2011) · Nature Methods · doi:10.1038/nmeth.1614 · Cited by 335
Droplet Microarrays: From Surface Patterning to High‐Throughput Applications
Feng, W., Ueda, E., & Levkin, P. A. (2018) · Advanced Materials · doi:10.1002/adma.201706111 · Cited by 246
Metadata
- Authors
- Berthier, E., Warrick, J., Yu, H., & Beebe, D. J.
- Affiliations
- University of Canterbury (NZ)
- University of Wisconsin–Madison (US)
- Corresponding author
- Beebe, David J.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2008
- Volume
- 8
- Issue
- 6
- Pages
- 852
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- PMC
- PMC2453240
- OpenAlex
- W2076407216
- Cited by
- 114
- References
- 47
- Citations by year
- 2026: 1 · 2025: 4 · 2024: 1 · 2023: 8 · 2022: 3 · 2021: 8 · 2020: 3 · 2019: 5 · 2018: 7 · 2017: 6 · 2016: 7 · 2015: 4 · 2014: 5 · 2013: 10 · 2012: 11
- FWCI
- 0.79
- Type
- journal article
- Language
- en
- Open access
- green
- europepmc.org
- Locations
- Lab on a Chip (publishedVersion)
- PubMed (publishedVersion)
- Europe PMC (PubMed Central) (acceptedVersion)
- PubMed Central (acceptedVersion)
- Funders
- MacDiarmid Institute for Advanced Materials and Nanotechnology
- National Cancer Institute (K25CA104162, R21CA122672)
- U.S. National Library of Medicine (T15LM007359)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Physical Sciences › Chemical Engineering › Fluid Flow and Transfer Processes › Innovative Microfluidic and Catalytic Techniques Innovation
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrowetting and Microfluidic Technologies
- Keywords
- evaporation, volume loss, high-throughput screening, combinatorial chemistry, osmolarity, assay robustness
- MeSH terms
- Autoanalysis, Biological Assay, Biology, Cell Physiological Phenomena, Miniaturization, Volatilization, Reproducibility of Results, Combinatorial Chemistry Techniques, Microfluidic Analytical Techniques
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.