Managing evaporation for more robust microscale assays : Part 1. Volume loss in high throughput assays
Open accessThe DOI matches its Crossref record; 49 of the 49 references it cites were found in a registry or an index.
Abstract
Evaporation is a well known issue when handling small liquid volumes. Here we present a review of microscale assays prone to evaporation and methods to make them more robust. Applications for these assays span from combinatorial chemistry to cell-biology where the stability of concentrations and osmolarity can be critical. A dimensionless evaporation number Ev is presented and used to characterize volume loss in short term and long term microscale assays. Ev can be used both as a design tool and as an analysis parameter. The advantageous use of evaporation in some applications is also discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“Rapid evaporation in microtiter plates is an acknowledged issue [41, 42].”
From The role of Raman spectroscopy in biopharmaceuticals from development to manufacturing (2022) · cites this paper as [42]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Capillary flow as the cause of ring stains from dried liquid drops
Deegan, R. D., Bakajin, O., Dupont, T. F., Huber, G., Nagel, S. R., & Witten, T. A. (1997) · Nature · doi:10.1038/39827 · Cited by 6,435
Microfluidics: Fluid physics at the nanoliter scale
Squires, T. M., & Quake, S. R. (2005) · Reviews of Modern Physics · doi:10.1103/revmodphys.77.977 · Cited by 4,379
Fabrication of microfluidic systems in poly(dimethylsiloxane)
McDonald, J. C., Duffy, D. C., Anderson, J. R., Chiu, D. T., Wu, H., Schueller, O. J. A., & Whitesides, G. M. (2000) · Electrophoresis · doi:10.1002/(sici)1522-2683(20000101)21:1<27::aid-elps27>3.0.co;2-c · Cited by 3,329
Contact line deposits in an evaporating drop
Deegan, R. D., Bakajin, O., Dupont, T. F., Huber, G., Nagel, S. R., & Witten, T. A. (2000) · Physical Review E · doi:10.1103/physreve.62.756 · Cited by 2,300
Berg, H. C., & Purcell, E. M. (1977) · Biophysical Journal · doi:10.1016/s0006-3495(77)85544-6 · Cited by 1,758
Cho, S. K., Moon, H., & Kim, C.-J. (2003) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2002.807467 · Cited by 1,598
Vali, G. (1971) · Journal of the Atmospheric Sciences · doi:10.1175/1520-0469(1971)028<0402:qeoera>2.0.co;2 · Cited by 852
A passive pumping method for microfluidic devices
Walker, G. M., & Beebe, D. J. (2002) · Lab on a Chip · doi:10.1039/b204381e · Cited by 420
Self-citationFlow and Fracture in Drying Nanoparticle Suspensions
Dufresne, E. R., Corwin, E. I., Greenblatt, N. A., Ashmore, J., Wang, D. Y., Dinsmore, A. D., Cheng, J. X., Xie, X. S., Hutchinson, J. W., & Weitz, D. A. (2003) · Physical Review Letters · doi:10.1103/physrevlett.91.224501 · Cited by 326
Jackman, R. J., Duffy, D. C., Ostuni, E., Willmore, N. D., & Whitesides, G. M. (1998) · Analytical Chemistry · doi:10.1021/ac971295a · Cited by 304
Research works printed but not linked: 3
- Litborn, 2000, Electrophoresis, 21, 91, 10.1002/(SICI)1522-2683(20000101)21:1<91::AID-ELPS91>3.0.CO;2-Y · doi:10.1002/(sici)1522-2683(20000101)21:1<91::aid-elps91>3.0.co;2-y
- Poulard, 2005, J. Phys.: Condens. Matter, 17, S4213
- Duguid, 1971, J. Atmos. Sci., 28, 1233, 10.1175/1520-0469(1971)028<1233:TEROSF>2.0.CO;2 · doi:10.1175/1520-0469(1971)028
Cited by
The present and future role of microfluidics in biomedical research
Sackmann, E. K., Fulton, A. L., & Beebe, D. J. (2014) · Nature · doi:10.1038/nature13118 · Cited by 2,995
Self-citationEngineers are from PDMS-land, Biologists are from Polystyrenia
Berthier, E., Young, E. W. K., & Beebe, D. (2012) · Lab on a Chip · doi:10.1039/c2lc20982a · Cited by 799
Self-citationFundamentals of microfluidic cell culture in controlled microenvironments
Young, E. W. K., & Beebe, D. J. (2010) · Chemical Society Reviews · doi:10.1039/b909900j · Cited by 615
Self-citationLecault, V., VanInsberghe, M., Sekulovic, S., Knapp, D. J. H. F., Wohrer, S., Bowden, W., Viel, F., McLaughlin, T., Jarandehei, A., Miller, M., et al. (2011) · Nature Methods · doi:10.1038/nmeth.1614 · Cited by 335
Droplet Microarrays: From Surface Patterning to High‐Throughput Applications
Feng, W., Ueda, E., & Levkin, P. A. (2018) · Advanced Materials · doi:10.1002/adma.201706111 · Cited by 246
Paguirigan, A. L., & Beebe, D. J. (2008) · BioEssays · doi:10.1002/bies.20804 · Cited by 208
Self-citationAutomated cell culture in high density tubeless microfluidic device arrays
Meyvantsson, I., Warrick, J. W., Hayes, S., Skoien, A., & Beebe, D. J. (2008) · Lab on a Chip · doi:10.1039/b715375a · Cited by 172
Self-citationApplication of microbioreactors in fermentation process development: a review
Schäpper, D., Alam, M. N. H. Z., Szita, N., Eliasson Lantz, A., & Gernaey, K. V. (2009) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-009-2955-x · Cited by 160
Microscale electroporation: challenges and perspectives for clinical applications
Lee, W. G., Demirci, U., & Khademhosseini, A. (2009) · Integrative Biology · doi:10.1039/b819201d · Cited by 154
Open Microfluidic Capillary Systems
Berthier, E., Dostie, A. M., Lee, U. N., Berthier, J., & Theberge, A. B. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.9b01429 · Cited by 148
Self-citationThe role of Raman spectroscopy in biopharmaceuticals from development to manufacturing
Esmonde-White, K. A., Cuellar, M., & Lewis, I. R. (2022) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-021-03727-4 · Cited by 152
Paguirigan, A. L., & Beebe, D. J. (2009) · Integrative Biology · doi:10.1039/b814565b · Cited by 136
Self-citationSticker, D., Rothbauer, M., Lechner, S., Hehenberger, M.-T., & Ertl, P. (2015) · Lab on a Chip · doi:10.1039/c5lc01028d · Cited by 129
Yarmush, M. L., & King, K. R. (2009) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160502 · Cited by 138
Passive microfluidic pumping using coupled capillary/evaporation effects
Lynn, N. S., Jr., & Dandy, D. S. (2009) · Lab on a Chip · doi:10.1039/b912213c · Cited by 121
Microfluidics: a concise review of the history, principles, design, applications, and future outlook
Hajam, M. I., & Khan, M. M. (2023) · Biomaterials Science · doi:10.1039/d3bm01463k · Cited by 132
Label‐Free Optofluidic Nanobiosensor Enables Real‐Time Analysis of Single‐Cell Cytokine Secretion
Li, X., Soler, M., Szydzik, C., Khoshmanesh, K., Schmidt, J., Coukos, G., Mitchell, A., & Altug, H. (2018) · Small · doi:10.1002/smll.201800698 · Cited by 110
A direct-to-biology high-throughput chemistry approach to reactive fragment screening
Thomas, R. P., Heap, R. E., Zappacosta, F., Grant, E. K., Pogány, P., Besley, S., Fallon, D. J., Hann, M. M., House, D., Tomkinson, N. C. O., et al. (2021) · Chemical Science · doi:10.1039/d1sc03551g · Cited by 95
Nelson, W. C., Peng, I. X., Lee, G. A., Loo, J. A., Garrell, R. L., & Kim, C. (2010) · Analytical Chemistry · doi:10.1021/ac101833b · Cited by 91
Bio-inspired wettability patterns for biomedical applications
Chi, J., Zhang, X., Wang, Y., Shao, C., Shang, L., & Zhao, Y. (2020) · Materials Horizons · doi:10.1039/d0mh01293a · Cited by 93
Du, Y., Shim, J., Vidula, M., Hancock, M. J., Lo, E., Chung, B. G., T. Borenstein, J., Khabiry, M., M. Cropek, D., & Khademhosseini, A. (2009) · Lab Chip · doi:10.1039/b815990d · Cited by 89
Liu, E. Y., Jung, S., & Yi, H. (2016) · Langmuir · doi:10.1021/acs.langmuir.6b02591 · Cited by 86
Miniaturizing chemistry and biology using droplets in open systems
Zeng, Y., Khor, J. W., van Neel, T. L., Tu, W., Berthier, J., Thongpang, S., Berthier, E., & Theberge, A. B. (2023) · Nature Reviews Chemistry · doi:10.1038/s41570-023-00483-0 · Cited by 91
Self-citationCharacterizing asthma from a drop of blood using neutrophil chemotaxis
Sackmann, E. K., Berthier, E., Schwantes, E. A., Fichtinger, P. S., Evans, M. D., Dziadzio, L., Huttenlocher, A., Mathur, S. K., & Beebe, D. J. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1324043111 · Cited by 81
“Briefly, the diagnostic chip has two primary components: (i) a functionalized migration channel in the base, where the rapid neutrophil purification and chemotaxis are performed, and (ii) a multifunction lid that houses all of the reagents required for the diagnostic test and mitigates evaporation, which can be detrim…”
BackgroundSelf-citationFabrication of whole-thermoplastic normally closed microvalve, micro check valve, and micropump
Pourmand, A., Shaegh, S. A. M., Ghavifekr, H. B., Aghdam, E. N., Dokmeci, M. R., Khademhosseini, A., & Zhang, Y. S. (2017) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2017.12.132 · Cited by 80
Microfluidic kit-on-a-lid: a versatile platform for neutrophil chemotaxis assays
Sackmann, E. K., Berthier, E., Young, E. W. K., Shelef, M. A., Wernimont, S. A., Huttenlocher, A., & Beebe, D. J. (2012) · Blood · doi:10.1182/blood-2012-03-416453 · Cited by 80
Self-citation“One Cell−One Well”: A New Approach to Inkjet Printing Single Cell Microarrays
Liberski, A. R., Delaney, J. T., & Schubert, U. S. (2010) · ACS Combinatorial Science · doi:10.1021/co100061c · Cited by 77
Zhang, J. Y., Do, J., Premasiri, W. R., Ziegler, L. D., & Klapperich, C. M. (2010) · Lab on a Chip · doi:10.1039/c0lc00051e · Cited by 80
Microfluidic Evaporation, Pervaporation, and Osmosis: From Passive Pumping to Solute Concentration
Bacchin, P., Leng, J., & Salmon, J. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00459 · Cited by 84
An arrayed high-content chemotaxis assay for patient diagnosis
Berthier, E., Surfus, J., Verbsky, J., Huttenlocher, A., & Beebe, D. (2010) · Integrative Biology · doi:10.1039/c0ib00030b · Cited by 68
Self-citationKo, Y., Maeng, J., Hwang, S. Y., & Ahn, Y. (2018) · SLAS TECHNOLOGY · doi:10.1177/2472630318783948 · Cited by 67
Lewis, C. L., Choi, C., Lin, Y., Lee, C., & Yi, H. (2010) · Analytical Chemistry · doi:10.1021/ac101032r · Cited by 64
Bischel, L. L., Mader, B. R., Green, J. M., Anna Huttenlocher, A., & Beebe, D. J. (2013) · Lab on a Chip · doi:10.1039/c3lc50099c · Cited by 63
Self-citationGradient generation platforms: new directions for an established microfluidic technology
Berthier, E., & Beebe, D. J. (2014) · Lab Chip · doi:10.1039/c4lc00448e · Cited by 63
Self-citationCell confinement in patterned nanoliter droplets in a microwell array by wiping
Kang, L., HANCOCK, M. J., Brigham, M. D., & Khademhosseini, A. (2009) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.32557 · Cited by 56
“By maintaining the array in a humid environment, evaporation is minimized and the droplets can be maintained.(24) Furthermore, provided the contact line of each droplet is inside the well, it cannot escape due to contact line pinning.”
Development of a single-use microbioreactor for cultivation of microorganisms
Schäpper, D., Stocks, S. M., Szita, N., Lantz, A. E., & Gernaey, K. V. (2010) · Chemical Engineering Journal · doi:10.1016/j.cej.2010.02.038 · Cited by 53
Berthier, E., Warrick, J., Yu, H., & Beebe, D. J. (2008) · Lab on a Chip · doi:10.1039/b717423c · Cited by 53
Self-citationChen, H., Li, X., & Li, D. (2022) · Nanotechnology and Precision Engineering · doi:10.1063/10.0013222 · Cited by 53
Developments in the integration and application of terahertz spectroscopy with microfluidics
Alfihed, S., Holzman, J. F., & Foulds, I. G. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112393 · Cited by 53
Rapid Manufacturing of Multilayered Microfluidic Devices for Organ on a Chip Applications
Paoli, R., Giuseppe, D. D., Badiola-Mateos, M., Martinelli, E., Lopez-Martinez, M. J., & Samitier, J. (2021) · Sensors · doi:10.3390/s21041382 · Cited by 48
“Samples were treated with O2 plasma (t = [1, 2, 5] min, 29.”
MethodScreening the Cellular Microenvironment: A Role for Microfluidics
Warrick, J. W., Murphy, W. L., & Beebe, D. J. (2008) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2008.2008241 · Cited by 45
“micro-scale technology, such as the possible effects of evaporation, depletion of soluble factors, and buildup of waste products in small volumes [36]–[40].”
Self-citationYunker, P. J., Gratale, M. D., Lohr, M., Still, T., Lubensky, T. C., & Yodh, A. G. (2012) · Physical Review Letters · doi:10.1103/physrevlett.108.228303 · Cited by 38
Going with the Flow: Modeling the Tumor Microenvironment Using Microfluidic Technology
Xie, H., Appelt, J. W., & Jenkins, R. W. (2021) · Cancers · doi:10.3390/cancers13236052 · Cited by 42
In Situ Assembly and Screening of Enzyme Inhibitors with Surface‐Tension Microarrays
Mugherli, L., Burchak, O. Ν., Balakireva, L. A., Thomas, A. M., Chatelain, F., & Balakirev, M. Y. (2009) · Angewandte Chemie International Edition · doi:10.1002/anie.200901139 · Cited by 38
Evaporation from microreservoirs
Lynn, N. S., Jr., Henry, C. S., & Dandy, D. S. (2009) · Lab on a Chip · doi:10.1039/b900556k · Cited by 38
Effect of Microculture on Cell Metabolism and Biochemistry: Do Cells Get Stressed in Microchannels?
Su, X., Theberge, A. B., January, C. T., & Beebe, D. J. (2013) · Analytical Chemistry · doi:10.1021/ac3027228 · Cited by 35
Self-citationBackward flow in a surface tension driven micropump
Ju, J., Park, J. Y., Kim, K. C., Kim, H. D., Berthier, E., Beebe, D. J., & Lee, S.-H. (2008) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/18/8/087002 · Cited by 34
“Evaporation has been used to generate flow from the output drop to the inlet port after the pressure balance is reached [7, 13].”
MethodSelf-citationReproducibility of Uniform Spheroid Formation in 384-Well Plates
Das, V., Fürst, T., Gurská, S., Džubák, P., & Hajdúch, M. (2016) · SLAS DISCOVERY · doi:10.1177/1087057116651867 · Cited by 39
“Sustainable improvements in culture conditions that prevent uneven loss of the medium decrease well-to-well variability in assay readouts.(9,10) Additionally, use of embryograde mineral oil is another alternative cost-effective approach of reducing medium evaporation from MPs.”
BackgroundInfluentialA Novel 96well-formatted Micro-gap Plate Enabling Drug Response Profiling on Primary Tumour Samples
Ma, W., Hsiung, L.-C., Wang, C.-H., Chiang, C., Lin, C., Huang, C., & Wo, A. M. (2015) · Scientific Reports · doi:10.1038/srep09656 · Cited by 31
Rise of the Micromachines: Microfluidics and the Future of Cytometry
Włodkowic, D., & Darżynkiewicz, Z. (2011) · Methods in cell biology · doi:10.1016/b978-0-12-374912-3.00005-5 · Cited by 30
“1) (Beebe et al., 2002; Berthier et al., 2008a, b; Wlodkowic et al., 2009a).”
An inertia enhanced passive pumping mechanism for fluid flow in microfluidic devices
Resto, P. J., Berthier, E., Beebe, D. J., & Williams, J. C. (2012) · Lab on a Chip · doi:10.1039/c2lc20858j · Cited by 29
Self-citationOverview of Materials for Microfluidic Applications
Roy, E., Pallandre, A., Zribi, B., Horny, M.-C., Delapierre, F. D., Cattoni, A., Gamby, J., & Haghiri‐Gosnet, A. (2016) · InTech eBooks · doi:10.5772/65773 · Cited by 39
A Disposable Microfluidic Virus Concentration Device Based on Evaporation and Interfacial Tension
Zhang, J. Y., Mahalanabis, M., Landaverde, L., Chang, J. C., Pollock, N. R., & Klapperich, C. M. (2013) · Diagnostics · doi:10.3390/diagnostics3010155 · Cited by 28
Interfacial Tension Driven Open Droplet Microfluidics
Khor, J. W., Lee, U. N., Berthier, J., Berthier, E., & Theberge, A. B. (2023) · Advanced Materials Interfaces · doi:10.1002/admi.202202234 · Cited by 27
“Methods to address evaporation and contamination such as secondary containment and sacrificial liquid droplets(38) or wells have been successfully employed with primary human samples.”
BackgroundSelf-citationKit-On-A-Lid-Assays for accessible self-contained cell assays
Berthier, E., Guckenberger, D. J., Cavnar, P. J., Huttenlocher, A., Keller, N. P., & Beebe, D. J. (2012) · Lab on a Chip · doi:10.1039/c2lc41019b · Cited by 29
Self-citationZhou, L., Zhuang, G., & Li, G. (2018) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2018.01.158 · Cited by 22
Preprogrammed, Parallel On-Chip Immunoassay Using System-Level Capillarity Control
Kim, S., Paczesny, S., Takayama, S., & Kurabayashi, K. (2013) · Analytical Chemistry · doi:10.1021/ac401292d · Cited by 22
Injection molded open microfluidic well plate inserts for user-friendly coculture and microscopy
Day, J. H., Nicholson, T. M., Su, X., van Neel, T. L., Clinton, I., Kothandapani, A., Lee, J., Greenberg, M. H., Amory, J. K., Walsh, T. J., et al. (2019) · Lab on a Chip · doi:10.1039/c9lc00706g · Cited by 25
3D Printed Tooling for Injection Molded Microfluidics
Convery, N., Samardzhieva, I., Stormonth-Darling, J., Harrison, S. P., Sullivan, G. J., & Gadegaard, N. (2021) · Macromolecular Materials and Engineering · doi:10.1002/mame.202100464 · Cited by 20
Leaf‐Inspired Patterned Organohydrogel Surface for Ultrawide Time‐Range Open Biosensing
Gao, H., Wan, X., Yang, Y., Lu, J., Zhu, Q., Xu, L., & Wang, S. (2023) · Advanced Science · doi:10.1002/advs.202207702 · Cited by 20
MICROBIOREACTORS AS ENGINEERING TOOLS FOR BIOPROCESS DEVELOPMENT
Prado, R., & Borges, É. R. (2018) · Brazilian Journal of Chemical Engineering · doi:10.1590/0104-6632.20180354s20170433 · Cited by 19
“Nevertheless, PDMS membranes are not selective to gases, allowing the diffusion of water vapour out of the fermentative chamber (Berthier et al., 2008; Schäpper et al., 2009).”
BackgroundOpenly Accessible Microfluidic Liquid Handlers for Automated High-Throughput Nanoliter Cell Culture
Zhou, Y., Pang, Y., & Huang, Y. (2012) · Analytical Chemistry · doi:10.1021/ac203469v · Cited by 18
Current Advances and Future Prospects of Bulk and Microfluidic‐Enabled Electroporation Systems
Li, F., Dong, C., Chen, T., Yu, S., & Chen, C. (2025) · Biotechnology and Bioengineering · doi:10.1002/bit.28965 · Cited by 17
“However, it should be noted that PDMS may have detrimental effects on biochemical reactions, as it releases oligomers (Regehr et al. 2009), absorbs small molecules (Toepke and Beebe 2006), permeates vapor (Berthier et al. 2008), and its controversial biocompatibility (Sackmann et al. 2014).”
Open multi-culture platform for simple and flexible study of multi-cell type interactions
Álvarez-García, Y. R., Ramos-Cruz, K. P., Agostini-Infanzón, R. J., Stallcop, L. E., Beebe, D. J., Warrick, J. W., & Domenech, M. (2018) · Lab on a Chip · doi:10.1039/c8lc00560e · Cited by 16
Self-citationDevelopment of in vitro model of exosome transport in microfluidic gut-brain axis-on-a-chip
Seo, G. M., Lee, H., Kang, Y. J., Kim, D., & Sung, J. H. (2024) · Lab on a Chip · doi:10.1039/d4lc00490f · Cited by 15
Addressable droplet microarrays for single cell protein analysis
Salehi‐Reyhani, A., Burgin, E., Ces, O., Willison, K. R., & Klug, D. R. (2014) · The Analyst · doi:10.1039/c4an01208a · Cited by 14
Transport velocity of droplets on ratchet conveyors
Holmes, H. R., & Böhringer, K. F. (2017) · Advances in Colloid and Interface Science · doi:10.1016/j.cis.2017.08.009 · Cited by 13
Droplet microfluidic technologies for next-generation high-throughput screening
Ali, M., Kim, W., & Park, J. (2023) · Frontiers in Lab on a Chip Technologies · doi:10.3389/frlct.2023.1230791 · Cited by 13
Ek, P., & Roeraade, J. (2011) · Analytical Chemistry · doi:10.1021/ac201308n · Cited by 12
High-Density Self-Contained Microfluidic KOALA Kits for Use by Everyone
Guckenberger, D. J., Berthier, E., & Beebe, D. J. (2014) · SLAS TECHNOLOGY · doi:10.1177/2211068214560609 · Cited by 12
Self-citationMicrofluidic devices for cell manipulation
Fatoyinbo, H. O. (2013) · Elsevier eBooks · doi:10.1533/9780857097040.3.283 · Cited by 11
Size based sorting and patterning of microbeads by evaporation driven flow in a 3D micro-traps array
Wong, C. C., Liu, Y., Wang, K. Y., & Rahman, A. (2013) · Lab on a Chip · doi:10.1039/c3lc50274k · Cited by 11
Zhang, H., Tiggelaar, R. M., Schlautmann, S., Bart, J., & Gardeniers, H. J. G. E. (2015) · Electrophoresis · doi:10.1002/elps.201500285 · Cited by 10
An overview of microfluidic devices
Maghsoudi, S., Rabiee, N., Ahmadi, S., Rabiee, M., Bagherzadeh, M., & Karimi, M. (2020) · Elsevier eBooks · doi:10.1016/b978-0-12-818791-3.00005-x · Cited by 11
Lopes, L. F. D. P., Agostini, V. O., & Muxagata, E. (2017) · Ecotoxicology and Environmental Safety · doi:10.1016/j.ecoenv.2017.12.004 · Cited by 9
Wörner, M., Cai, X., Alla, H., & Yue, P. (2018) · Fluid Dynamics Research · doi:10.1088/1873-7005/aaaef6 · Cited by 9
Zhang, C., & Xing, D. (2009) · Microfluidics and Nanofluidics · doi:10.1007/s10404-009-0508-4 · Cited by 8
“One of the well-known issues using miniaturized bioreaction systems is evaporation at the open air‐liquid interfaces ( Berthier et al. 2008a, b; Lynn et al. 2009; Eijkel and van den Berg 2005).”
BackgroundInfluentialDas, V., Fürst, T., Gurská, S., Džubák, P., & Hajdúch, M. (2017) · Journal of Visualized Experiments · doi:10.3791/55403 · Cited by 13
In Situ Assembly and Screening of Enzyme Inhibitors with Surface‐Tension Microarrays
Mugherli, L., Burchak, O. Ν., Balakireva, L. A., Thomas, A. M., Chatelain, F., & Balakirev, M. Y. (2009) · Angewandte Chemie · doi:10.1002/ange.200901139 · Cited by 9
Leslie, D. C., Melnikoff, B. A., Marchiarullo, D. J., Cash, D. R., Ferrance, J. P., & Landers, J. P. (2010) · Lab on a Chip · doi:10.1039/c003244a · Cited by 8
Rocha, D. S., de Campos, R. P. S., Silva‐Neto, H. A., Duarte‐Junior, G. F., Fethi Bedioui, A., & Coltro, W. K. T. (2023) · Analytica Chimica Acta · doi:10.1016/j.aca.2023.341077 · Cited by 8
Detection of ricin in beverages using cell-free protein synthesis in a microfluidic device
Khnouf, R., Chapman, B. D., Jin, S., Beebe, D. J., & Fan, Z. H. (2015) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2015.06.077 · Cited by 8
Self-citationCoffee-rings and glasses: Colloids out of equilibrium
Yunker, P. J. (2012) · Cited by 8
Electrospray ionization mass spectrometry from discrete nanoliter‐sized sample volumes
Ek, P., Stjernström, M., Emmer, Å., & Roeraade, J. (2010) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.4674 · Cited by 7
Lee, Y., Lee, G., Cho, M., & Park, J. (2019) · Journal of Micromechanics and Microengineering · doi:10.1088/1361-6439/ab0796 · Cited by 7
Shen, X., Hasyyati, F. I., Schroën, K. G. P. H., van der Gucht, J., & Deshpande, S. (2025) · Small · doi:10.1002/smll.202507603 · Cited by 6
Li, M., Hu, H., Zhang, M., Ding, H., Wen, J., Xie, L., & Du, P. (2023) · Langmuir · doi:10.1021/acs.langmuir.3c01884 · Cited by 6
A microfluidic multiwell chip for enzyme-free detection of mRNA from few cells
Haider, M., Ji, B., Haselgrübler, T., Sonnleitner, A., Aberger, F., & Hesse, J. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.06.019 · Cited by 6
“Despite the numerous advantages of passive microfluidic devices, partial evaporation can be a major challenge when handling minute amounts of fluid (Berthier et al., 2008).”
BackgroundA novel technique for positioning multiple cell types by liquid handling
Luong-Van, E. K., Kang, R. K. C., & Birch, W. R. (2009) · Biointerphases · doi:10.1116/1.3122025 · Cited by 6
Simple microfluidic device for spectroelectrochemistry
Wang, W., Grace, H. M., & Flowers, P. A. (2022) · Microchemical Journal · doi:10.1016/j.microc.2022.107718 · Cited by 5
Schneider, L., Fraser, M., & Tripathi, A. (2021) · RSC Advances · doi:10.1039/d1ra01732b · Cited by 4
Cell-based Microfluidic Assays in Translational Medicine
Sackmann, E. K., Casavant, B. P., Moussavi-Harami, S. F., Beebe, D. J., & Lang, J. M. (2013) · Springer eBooks · doi:10.1007/978-1-4471-4372-7_33 · Cited by 4
Self-citationDang, K. M., Rinklin, P., Schnitker, J., Haberkorn, B., Zobel, K., Gribaudo, S., Perrier, A. L., Carolus, J., Daenen, M., Weigel, S., et al. (2017) · physica status solidi (a) · doi:10.1002/pssa.201600729 · Cited by 4
Dhall, A., Masiello, T. J., Gattu, S., Strohmayer, M., Butt, L., Hemachandra, L. P. M., Schujman, S. B., Tokranova, N. A., Khoury, J. T., Rao, S. S. P., et al. (2019) · Surfaces · doi:10.3390/surfaces2010009 · Cited by 4
“Furthermore, the high vapor permeability of PDMS can lead to evaporation [19].”
BackgroundLaboratory Techniques in Cellular and Molecular Medicine
Ed., J. S., Janošťáková, A., Das, V., Kudlová, N., Stránská, J., Buriánová, R., Kotulová, J., Schadich, E., Ondra, M., Kubíčková, A., et al. (2022) · doi:10.5507/lf.22.24460499 · Cited by 8
Microfluidics for Cell Culture
Devadas, D., & Young, E. W. K. (2016) · Springer eBooks · doi:10.1007/978-3-319-30019-1_15 · Cited by 3
Microfluidic devices for cell manipulation
Fatoyinbo, H. O., & Li, X. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-819971-8.00017-2 · Cited by 2
Ultra‐High‐Throughput Nanoliter‐Scale Liquid‐Liquid Extractions and Reaction Mixture Purification
Iwohn, M. J., Wiedmann, J. J., & Levkin, P. A. (2025) · Advanced Materials Interfaces · doi:10.1002/admi.202500465 · Cited by 1
Chen, S., Deng, C., Liu, Y., Huang, X., Chen, X., Yang, G., & Liu, H. (2025) · BMC Microbiology · doi:10.1186/s12866-025-04340-6 · Cited by 2
“These include interference from colored monomers on OD 600 readings [35], microplate evaporation effects, and subjective errors associated with manual turbidity interpretation [36].”
Integrated Microfluidic Sample Preparation for Chip-based Molecular Diagnostics
Zhang, J. Y., Cao, Q., Mahalanabis, M., & Klapperich, C. M. (2012) · WORLD SCIENTIFIC eBooks · doi:10.1142/9789814405522_0007 · Cited by 1
Metadata
- Authors
- Berthier, E., Warrick, J., Yu, H., & Beebe, D. J.
- Affiliations
- University of Canterbury (NZ)
- University of Wisconsin–Madison (US)
- Corresponding author
- Beebe, David J.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2008
- Volume
- 8
- Issue
- 6
- Pages
- 852
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- PMC
- PMC2453240
- OpenAlex
- W2076407216
- Cited by
- 114
- References
- 47
- Citations by year
- 2026: 1 · 2025: 4 · 2024: 1 · 2023: 8 · 2022: 3 · 2021: 8 · 2020: 3 · 2019: 5 · 2018: 7 · 2017: 6 · 2016: 7 · 2015: 4 · 2014: 5 · 2013: 10 · 2012: 11
- FWCI
- 0.79
- Type
- journal article
- Language
- en
- Open access
- green
- europepmc.org
- Locations
- Lab on a Chip (publishedVersion)
- PubMed (publishedVersion)
- Europe PMC (PubMed Central) (acceptedVersion)
- PubMed Central (acceptedVersion)
- Funders
- MacDiarmid Institute for Advanced Materials and Nanotechnology
- National Cancer Institute (K25CA104162, R21CA122672)
- U.S. National Library of Medicine (T15LM007359)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Physical Sciences › Chemical Engineering › Fluid Flow and Transfer Processes › Innovative Microfluidic and Catalytic Techniques Innovation
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrowetting and Microfluidic Technologies
- Keywords
- evaporation, volume loss, high-throughput screening, combinatorial chemistry, osmolarity, assay robustness
- MeSH terms
- Autoanalysis, Biological Assay, Biology, Cell Physiological Phenomena, Miniaturization, Volatilization, Reproducibility of Results, Combinatorial Chemistry Techniques, Microfluidic Analytical Techniques
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.