The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Pillar-induced droplet merging in microfluidic circuits
Abstract
A novel method is presented for controllably merging aqueous microdroplets within segmented flow microfluidic devices. Our approach involves exploiting the difference in hydrodynamic resistance of the continuous phase and the surface tension of the discrete phase through the use of passive structures contained within a microfluidic channel. Rows of pillars separated by distances smaller than the representative droplet dimension are installed within the fluidic network and define passive merging elements or chambers. Initial experiments demonstrate that such a merging element can controllably adjust the distance between adjacent droplets. In a typical scenario, a droplet will enter the chamber, slow down and stop. It will wait and then merge with the succeeding droplets until the surface tension is overwhelmed by the hydraulic pressure. We show that such a merging process is independent of the inter-droplet separation but rather dependent on the droplet size. Moreover, the number of droplets that can be merged at any time is also dependent on the mass flow rate and volume ratio between the droplets and the merging chamber. Finally, we note that the merging of droplet interfaces occurs within both compressing and the decompressing regimes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Xia, Y., & Whitesides, G. M. (1998) · Angewandte Chemie International Edition · doi:10.1002/(sici)1521-3773(19980316)37:5<550::aid-anie550>3.0.co;2-g · Cited by 4,285
Formation of dispersions using “flow focusing” in microchannels
Anna, S. L., Bontoux, N., & Stone, H. A. (2003) · Applied Physics Letters · doi:10.1063/1.1537519 · Cited by 2,302
Dynamic Pattern Formation in a Vesicle-Generating Microfluidic Device
Thorsen, T., Roberts, R. W., Arnold, F. H., & Quake, S. R. (2001) · Physical Review Letters · doi:10.1103/physrevlett.86.4163 · Cited by 2,051
Continuous Particle Separation Through Deterministic Lateral Displacement
Huang, L. R., Cox, E. C., Austin, R. H., & Sturm, J. C. (2004) · Science · doi:10.1126/science.1094567 · Cited by 1,634
Control and detection of chemical reactions in microfluidic systems
deMello, A. J. (2006) · Nature · doi:10.1038/nature05062 · Cited by 1,495
Self-citationGeometrically Mediated Breakup of Drops in Microfluidic Devices
Link, D. R., Anna, S. L., Weitz, D. A., & Stone, H. A. (2004) · Physical Review Letters · doi:10.1103/physrevlett.92.054503 · Cited by 1,202
Shestopalov, I., Tice, J. D., & Ismagilov, R. F. (2004) · Lab on a Chip · doi:10.1039/b403378g · Cited by 571
He, M., Edgar, J. S., Jeffries, G. D. M., Lorenz, R. M., Shelby, J. P., & Chiu, D. T. (2005) · Analytical Chemistry · doi:10.1021/ac0480850 · Cited by 518
Prakash, M., & Gershenfeld, N. (2007) · Science · doi:10.1126/science.1136907 · Cited by 511
Tan, Y.-C., Fisher, J. S., Lee, A. I., Cristini, V., & Lee, A. P. (2004) · Lab on a Chip · doi:10.1039/b403280m · Cited by 509
Cited by
Single-cell analysis and sorting using droplet-based microfluidics
Mazutis, L., Gilbert, J., Ung, W. L., Weitz, D. A., Griffiths, A. D., & Heyman, J. A. (2013) · Nature Protocols · doi:10.1038/nprot.2013.046 · Cited by 1,355
Droplet microfluidic technology for single-cell high-throughput screening
Brouzes, E., Medkova, M., Savenelli, N., Marran, D., Twardowski, M., Hutchison, J. B., Rothberg, J. M., Link, D. R., Perrimon, N., & Samuels, M. L. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0903542106 · Cited by 1,069
Dynamics of microfluidic droplets
Baroud, C. N., Gallaire, F., & Dangla, R. (2010) · Lab on a Chip · doi:10.1039/c001191f · Cited by 1,067
Microdroplets in Microfluidics: An Evolving Platform for Discoveries in Chemistry and Biology
Theberge, A. B., Courtois, F., Schaerli, Y., Fischlechner, M., Abell, C., Hollfelder, F., & Huck, W. T. S. (2010) · Angewandte Chemie International Edition · doi:10.1002/anie.200906653 · Cited by 1,059
Seemann, R., Brinkmann, M., Pfohl, T., & Herminghaus, S. (2012) · Reports on Progress in Physics · doi:10.1088/0034-4885/75/1/016601 · Cited by 1,049
Droplet Microfluidics—A Tool for Single‐Cell Analysis
Joensson, H. N., & Andersson Svahn, H. (2012) · Angewandte Chemie International Edition · doi:10.1002/anie.201200460 · Cited by 557
Droplet microfluidics for microbiology: techniques, applications and challenges
Kaminski, T. S., Scheler, O., & Garstecki, P. (2016) · Lab on a Chip · doi:10.1039/c6lc00367b · Cited by 424
Latest Developments in Micro Total Analysis Systems
Arora, A., Simone, G., Salieb-Beugelaar, G. B., Kim, J. T., & Manz, A. (2010) · Analytical Chemistry · doi:10.1021/ac100969k · Cited by 421
Sequential bottom-up assembly of mechanically stabilized synthetic cells by microfluidics
Weiss, M., Frohnmayer, J. P., Benk, L. T., Haller, B., Janiesch, J.-W., Heitkamp, T., Börsch, M., Lira, R. B., Dimova, R., Lipowsky, R., et al. (2018) · Nature Materials · doi:10.1038/nmat5005 · Cited by 404
Shembekar, N., Chaipan, C., Utharala, R., & Merten, C. A. (2016) · Lab on a Chip · doi:10.1039/c6lc00249h · Cited by 372
Analytical detection techniques for droplet microfluidics—A review
Zhu, Y., & Fang, Q. (2013) · Analytica Chimica Acta · doi:10.1016/j.aca.2013.04.064 · Cited by 365
Droplet microfluidics: recent developments and future applications
Casadevall i Solvas, X., & deMello, A. (2011) · Chem. Commun. · doi:10.1039/c0cc02474k · Cited by 353
Self-citationMoragues, T., Arguijo, D., Beneyton, T., Modavi, C., Simutis, K., Abate, A. R., Baret, J.-C., deMello, A. J., Densmore, D., & Griffiths, A. D. (2023) · Nature Reviews Methods Primers · doi:10.1038/s43586-023-00212-3 · Cited by 316
Self-citationIndustrial lab-on-a-chip: Design, applications and scale-up for drug discovery and delivery
Vladisavljević, G. T., Khalid, N., Neves, M. A., Kuroiwa, T., Nakajima, M., Uemura, K., Ichikawa, S., & Kobayashi, I. (2013) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2013.07.017 · Cited by 313
Droplets Formation and Merging in Two-Phase Flow Microfluidics
Gu, H., Duits, M. H. G., & Mugele, F. (2011) · International Journal of Molecular Sciences · doi:10.3390/ijms12042572 · Cited by 312
Functional single-cell hybridoma screening using droplet-based microfluidics
Debs, B. E., Utharala, R., Balyasnikova, I. V., Griffiths, A. D., & Merten, C. A. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1204514109 · Cited by 276
Concentration gradient generation methods based on microfluidic systems
Wang, X., Liu, Z., & Pang, Y. (2017) · RSC Advances · doi:10.1039/c7ra04494a · Cited by 219
Metadata
- Authors
- Niu, X., Gulati, S., Edel, J. B., & deMello, A. J.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2008
- Volume
- 8
- Issue
- 11
- Pages
- 1837
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2021247449
- Cited by
- 374
- References
- 18
- FWCI
- 14.28
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.