The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Fluorescence-activated droplet sorting (FADS): efficient microfluidic cell sorting based on enzymatic activity
Abstract
We describe a highly efficient microfluidic fluorescence-activated droplet sorter (FADS) combining many of the advantages of microtitre-plate screening and traditional fluorescence-activated cell sorting (FACS). Single cells are compartmentalized in emulsion droplets, which can be sorted using dielectrophoresis in a fluorescence-activated manner (as in FACS) at rates up to 2000 droplets s(-1). To validate the system, mixtures of E. coli cells, expressing either the reporter enzyme beta-galactosidase or an inactive variant, were compartmentalized with a fluorogenic substrate and sorted at rates of approximately 300 droplets s(-1). The false positive error rate of the sorter at this throughput was <1 in 10(4) droplets. Analysis of the sorted cells revealed that the primary limit to enrichment was the co-encapsulation of E. coli cells, not sorting errors: a theoretical model based on the Poisson distribution accurately predicted the observed enrichment values using the starting cell density (cells per droplet) and the ratio of active to inactive cells. When the cells were encapsulated at low density ( approximately 1 cell for every 50 droplets), sorting was very efficient and all of the recovered cells were the active strain. In addition, single active droplets were sorted and cells were successfully recovered.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rapid Prototyping of Microfluidic Systems in Poly(dimethylsiloxane)
Duffy, D. C., McDonald, J. C., Schueller, O. J. A., & Whitesides, G. M. (1998) · Analytical Chemistry · doi:10.1021/ac980656z · Cited by 5,288
Formation of dispersions using “flow focusing” in microchannels
Anna, S. L., Bontoux, N., & Stone, H. A. (2003) · Applied Physics Letters · doi:10.1063/1.1537519 · Cited by 2,302
Geometrically Mediated Breakup of Drops in Microfluidic Devices
Link, D. R., Anna, S. L., Weitz, D. A., & Stone, H. A. (2004) · Physical Review Letters · doi:10.1103/physrevlett.92.054503 · Cited by 1,202
Self-citationA Microfluidic System for Controlling Reaction Networks in Time
Song, H., Tice, J. D., & Ismagilov, R. F. (2003) · Angewandte Chemie International Edition · doi:10.1002/anie.200390203 · Cited by 1,082
Man-made cell-like compartments for molecular evolution
Tawfik, D. S., & Griffiths, A. D. (1998) · Nature Biotechnology · doi:10.1038/nbt0798-652 · Cited by 956
Self-citationPolymyxin and Related Peptide Antibiotics
Storm, D. R., Rosenthal, K. S., & Swanson, P. E. (1977) · Annual Review of Biochemistry · doi:10.1146/annurev.bi.46.070177.003451 · Cited by 759
Electric Control of Droplets in Microfluidic Devices
Link, D. R., Grasland‐Mongrain, E., Duri, A., Sarrazin, F., Cheng, Z., Cristobal, G., Márquez, M., & Weitz, D. A. (2006) · Angewandte Chemie International Edition · doi:10.1002/anie.200503540 · Cited by 754
Self-citationClausell-Tormos, J., Lieber, D., Baret, J.-C., El-Harrak, A., Miller, O. J., Frenz, L., Blouwolff, J., Humphry, K. J., Köster, S., Duan, H., et al. (2008) · Chemistry & Biology · doi:10.1016/j.chembiol.2008.04.004 · Cited by 720
Self-citationBiocompatible surfactants for water-in-fluorocarbon emulsions
Holtze, C., Rowat, A. C., Agresti, J. J., Hutchison, J. B., Angilè, F. E., Schmitz, C. H. J., Köster, S., Duan, H., Humphry, K. J., Scanga, R. A., et al. (2008) · Lab on a Chip · doi:10.1039/b806706f · Cited by 670
Self-citationDrop-based microfluidic devices for encapsulation of single cells
Köster, S., Angilè, F. E., Duan, H., Agresti, J. J., Wintner, A., Schmitz, C., Rowat, A. C., Merten, C. A., Pisignano, D., Griffiths, A. D., et al. (2008) · Lab on a Chip · doi:10.1039/b802941e · Cited by 518
Self-citationControlled encapsulation of single-cells into monodisperse picolitre drops
Edd, J. F., Di Carlo, D., Humphry, K. J., Köster, S., Irimia, D., Weitz, D. A., & Toner, M. (2008) · Lab on a Chip · doi:10.1039/b805456h · Cited by 511
Self-citationQuantitative detection of protein expression in single cells using droplet microfluidics
Huebner, A., Srisa-Art, M., Holt, D., Abell, C., Hollfelder, F., deMello, A. J., & Edel, J. B. (2007) · Chemical Communications · doi:10.1039/b618570c · Cited by 370
Miniaturising the laboratory in emulsion droplets
Griffiths, A. D., & Tawfik, D. S. (2006) · Trends in Biotechnology · doi:10.1016/j.tibtech.2006.06.009 · Cited by 346
Self-citationMicrofluidic high-throughput encapsulation and hydrodynamic self-sorting of single cells
Chabert, M., & Viovy, J.-L. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0708321105 · Cited by 344
Electrocoalescence of drops synchronized by size-dependent flow in microfluidic channels
Ahn, K., Agresti, J., Chong, H., Marquez, M., & Weitz, D. A. (2006) · Applied Physics Letters · doi:10.1063/1.2218058 · Cited by 300
Self-citationThe Future of High-Throughput Screening
Mayr, L. M., & Fuerst, P. (2008) · SLAS Discovery · doi:10.1177/1087057108319644 · Cited by 276
Aharoni, A., Amitai, G., Bernath, K., Magdassi, S., & Tawfik, D. S. (2005) · Chemistry & Biology · doi:10.1016/j.chembiol.2005.09.012 · Cited by 225
Mastrobattista, E., Taly, V., Chanudet, E., Treacy, P., Kelly, B. T., & Griffiths, A. D. (2005) · Chemistry & Biology · doi:10.1016/j.chembiol.2005.09.016 · Cited by 222
Self-citationMicrosolidics: Fabrication of Three‐Dimensional Metallic Microstructures in Poly(dimethylsiloxane)
Siegel, A. C., Bruzewicz, D. A., Weibel, D. B., & Whitesides, G. M. (2007) · Advanced Materials · doi:10.1002/adma.200601787 · Cited by 212
Droplet breakup in microfluidic junctions of arbitrary angles
Ménétrier-Deremble, L., & Tabeling, P. (2006) · Physical Review E · doi:10.1103/physreve.74.035303 · Cited by 190
Courtois, F., Olguin, L. F., Whyte, G., Bratton, D., Huck, W. T. S., Abell, C., & Hollfelder, F. (2008) · ChemBioChem · doi:10.1002/cbic.200700536 · Cited by 183
From Microdroplets to Microfluidics: Selective Emulsion Separation in Microfluidic Devices
Fidalgo, L. M., Whyte, G., Bratton, D., Kaminski, C. F., Abell, C., & Huck, W. T. S. (2008) · Angewandte Chemie International Edition · doi:10.1002/anie.200704903 · Cited by 165
Microfluidic-Based Cell Sorting of Francisella tularensis Infected Macrophages Using Optical Forces
Perroud, T. D., Kaiser, J. N., Sy, J. C., Lane, T. W., Branda, C., Singh, A. K., & Patel, K. D. (2008) · Analytical Chemistry · doi:10.1021/ac8007779 · Cited by 93
Commercial high speed machines open new opportunities in high throughput flow cytometry (HTFC)
Ashcroft, R. G., & Lopez, P. (2000) · Journal of Immunological Methods · doi:10.1016/s0022-1759(00)00219-2 · Cited by 77
International Society for Analytical Cytology Biosafety Standard for Sorting of Unfixed Cells
Schmid, I., Lambert, C., Ambrozak, D. R., Marti, G. E., Moss, D. M., & Perfetto, S. P. (2007) · Cytometry Part A · doi:10.1002/cyto.a.20390 · Cited by 52
Cited by
Droplet barcoding for single-cell transcriptomics applied to embryonic stem cells
Klein, A. M., Mazutis, L., Akartuna, I., Tallapragada, N., Veres, A., Li, V., Peshkin, L., Weitz, D. A., & Kirschner, M. W. (2015) · Cell · doi:10.1016/j.cell.2015.04.044 · Cited by 3,356
Self-citationSingle-cell analysis and sorting using droplet-based microfluidics
Mazutis, L., Gilbert, J., Ung, W. L., Weitz, D. A., Griffiths, A. D., & Heyman, J. A. (2013) · Nature Protocols · doi:10.1038/nprot.2013.046 · Cited by 1,355
Self-citationUltrahigh-throughput screening in drop-based microfluidics for directed evolution
Agresti, J. J., Antipov, E., Abate, A. R., Ahn, K., Rowat, A. C., Baret, J.-C., Marquez, M., Klibanov, A. M., Griffiths, A. D., & Weitz, D. A. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0910781107 · Cited by 1,149
Self-citationMicrodroplets in Microfluidics: An Evolving Platform for Discoveries in Chemistry and Biology
Theberge, A. B., Courtois, F., Schaerli, Y., Fischlechner, M., Abell, C., Hollfelder, F., & Huck, W. T. S. (2010) · Angewandte Chemie International Edition · doi:10.1002/anie.200906653 · Cited by 1,059
Seemann, R., Brinkmann, M., Pfohl, T., & Herminghaus, S. (2012) · Reports on Progress in Physics · doi:10.1088/0034-4885/75/1/016601 · Cited by 1,049
Metadata
- Authors
- Baret, J.-C., Miller, O. J., Taly, V., Ryckelynck, M., El-Harrak, A., Frenz, L., Rick, C., Samuels, M. L., Hutchison, J. B., Agresti, J. J., Link, D. R., Weitz, D. A., & Griffiths, A. D.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2009
- Volume
- 9
- Issue
- 13
- Pages
- 1850
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2029886517
- Cited by
- 951
- References
- 25
- FWCI
- 27.17
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.