Electric field standing wave artefacts in FTIR micro-spectroscopy of biological materials
The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Abstract
FTIR absorption micro-spectroscopy is a widely used, powerful technique for analysing biological materials. In principle it is a straightforward linear absorption spectroscopy, but it can be affected by artefacts that complicate the interpretation of the data. In this article, artefacts produced by the electric-field standing-wave (EFSW) in micro-reflection-absorption (transflection) spectroscopy are investigated. An EFSW is present at reflective metallic surfaces due to the interference of incident and reflected light. The period of this standing wave is dependent on the wavelength of the radiation and can produce non-linear changes in absorbance with increasing sample thickness (non-Beer-Lambert like behaviour). A protein micro-structure was produced as a simple experimental model for a biological cell and used to evaluate the differences between FTIR spectra collected in transmission and transflection. By varying the thickness of the protein samples, the relationship between the absorbance and sample thickness in transflection was determined, and shown to be consistent with optical interference due to the EFSW coupled with internal reflection from the sample top surface. FTIR spectral image data from MCF 7 breast adenocarcinoma cells was then analysed to determine the severity of the EFSW artefact in data from a real sample. The results from these measurements confirmed that the EFSW artefact has a profound effect on transflection spectra, and in this case the main spectral variations were related to the sample thickness rather than any biochemical differences.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Matplotlib: a 2D graphics environment
Hunter, J. D. (2007) · Computing in Science & Engineering · doi:10.1109/mcse.2007.55 · Cited by 39,249
WSXM: A software for scanning probe microscopy and a tool for nanotechnology
Horcas, I., Fernández, R., Gómez-Rodríguez, J. M., Colchero, J., Gómez-Herrero, J., & Baro, A. M. (2007) · Review of Scientific Instruments · doi:10.1063/1.2432410 · Cited by 7,738
Capillary flow as the cause of ring stains from dried liquid drops
Deegan, R. D., Bakajin, O., Dupont, T. F., Huber, G., Nagel, S. R., & Witten, T. A. (1997) · Nature · doi:10.1038/39827 · Cited by 6,435
Python for scientific computing
Oliphant, T. E. (2007) · Computing in Science & Engineering · doi:10.1109/mcse.2007.58 · Cited by 3,303
The Use and Misuse of FTIR Spectroscopy in the Determination of Protein Structure
Jackson, M., & Mantsch, H. H. (1995) · Critical Reviews in Biochemistry and Molecular Biology · doi:10.3109/10409239509085140 · Cited by 2,037
Infrared Study of Adsorbed Molecules on Metal Surfaces by Reflection Techniques
Greenler, R. G. (1966) · The Journal of Chemical Physics · doi:10.1063/1.1726462 · Cited by 1,526
Hansen, W. N. (1968) · Journal of the Optical Society of America · doi:10.1364/josa.58.000380 · Cited by 729
Pulsed terahertz spectroscopy of DNA, bovine serum albumin and collagen between 0.1 and 2.0 THz
Markelz, A. G., Roitberg, A., & Heilweil, E. J. (2000) · Chemical Physics Letters · doi:10.1016/s0009-2614(00)00227-x · Cited by 705
Applications of ATR-FTIR spectroscopic imaging to biomedical samples
Kazarian, S. G., & Chan, K. L. A. (2006) · Biochimica et Biophysica Acta (BBA) - Biomembranes · doi:10.1016/j.bbamem.2006.02.011 · Cited by 379
Infrared Spectra of Monolayers on Metal Mirrors
Francis, S. A., & Ellison, A. H. (1959) · Journal of the Optical Society of America · doi:10.1364/josa.49.000131 · Cited by 343
Research works printed but not linked: 1
- Filik, J. Phys.: Conf. Ser.
Cited by
Items 101–122 of 122
Wilk, A., Dróźdż, A., Olbrich, K., Janik-Olchawa, N., Setkowicz, Z., & Chwiej, J. G. (2022) · Spectrochimica Acta Part A Molecular and Biomolecular Spectroscopy · doi:10.1016/j.saa.2022.122086 · Cited by 4
Inverted Transflection Spectroscopy of Live Cells Using Metallic Grating on Elevated Nanopillars
Mahalanabish, A., Huang, S. H., & Shvets, G. B. (2024) · ACS Sensors · doi:10.1021/acssensors.3c02031 · Cited by 5
Steger, S., Stege, H., Bretz, S., & Hãhn, O. (2020) · Journal of Cultural Heritage · doi:10.1016/j.culher.2020.11.008 · Cited by 3
"ISOLATION AND QUANTIFICATION OF CELLULOSE FROM VARIOUS FOOD-GRADE MACROALGAL SPECIES"
", Muthukumar, J., & Chidambaram, R. (2023) · Cellulose Chemistry and Technology · doi:10.35812/cellulosechemtechnol.2023.57.23 · Cited by 6
Cold shock induces apoptosis of dorsal root ganglion neurons plated on infrared windows
Aboualizadeh, E., Mattson, E. C., O’Hara, C. L., Smith, A. K., Stucky, C. L., & Hirschmugl, C. J. (2015) · The Analyst · doi:10.1039/c5an00729a · Cited by 3
Maurais, J., & Ayotte, P. (2020) · The Journal of Chemical Physics · doi:10.1063/1.5141934 · Cited by 3
Data Preprocessing and Data Processing in Microspectral Analysis
(2015) · Wiley eBooks · doi:10.1002/9781118824924.ch12 · Cited by 3
Mayerhöfer, T. G., Pahlow, S., Huebner, U., & Popp, J. (2025) · Applied Spectroscopy · doi:10.1177/00037028251368394 · Cited by 2
Lima, C. A. (2015) · Digital Library of Theses and Dissertations (Universidade de São Paulo) · doi:10.11606/d.85.2015.tde-28082015-100900 · Cited by 2
Deviations from the (Bouguer-) Beer-Lambert approximation
Mayerhöfer, T. G. (2024) · Elsevier eBooks · doi:10.1016/b978-0-443-22031-9.00013-6 · Cited by 1
Fourier Transform Infrared (Ft-Ir) Spectroscopic Imaging for Solid Tumor Histopathology
Biswas, S., Walsh, M. J., & Bhargava, R. (2013) · Challenges and advances in computational chemistry and physics · doi:10.1007/978-94-007-7832-0_16 · Cited by 2
Perspectives of environmental health issues addressed by advanced nanostructures
Baia, L., Baia, M., Hernádi, K., Pap, Z., & Popp, J. (2020) · Elsevier eBooks · doi:10.1016/b978-0-12-815882-1.00013-6 · Cited by 1
An Introduction to Infra‐red and R aman Spectroscopies for Pharmaceutical and Biomedical Studies
Chan, K. L. A. (2019) · Wiley eBooks · doi:10.1002/9781119483977.ch13 · Cited by 2
Chemometrics of biological tissues using infrared spectroscopy
de Castro, P. A. A. (2022) · Digital Library of Theses and Dissertations (Universidade de São Paulo) · doi:10.11606/t.85.2022.tde-12092022-112422 · Cited by 1
Diagnostic neuropathology of brain tumours using biophotonics and spectrometry
Mudariki, T. (2016) · CLOK (University of Central Lancashire)
Absorption spectral imaging in the mid-infrared and its application in cancer diagnosis
Drummond, L. A. (2014) · Spiral (Imperial College London) · doi:10.25560/44834
“However, transflection has inherent issues that result in the data from such a setup being untrustworthy due to the electric-field standing wave at the reflective interface giving rise to a spectrum that is nonlinear across wavelengths [39-41].”
BackgroundSkin cancer diagnosis using infrared microspectroscopy imaging as a molecular pathology tool
Lima, C. A. (2019) · Digital Library of Theses and Dissertations (Universidade de São Paulo) · doi:10.11606/t.85.2019.tde-05062019-155251
Ho, D. M., Banaś, A., Banaś, K., Mali, U., & Breese, M. B. H. (2026) · Sensors · doi:10.3390/s26051491
“Although minor scan-to-scan variability is expected due to random noise, the significant differences in band intensities observed here, coupled with the high signal-to-noise ratio (SNR) of the spectra, strongly suggest genuine chemical heterogeneity rather than instrumental artifact [28–31].”
Diagnostic pré-symptomatique rapide du sepsis par spectroscopie vibrationnelle
Lovergne, L. (2018) · theses.fr (ABES) · doi:10.70675/ffbeee35z7493z4e25za44dzc5b31c20ada0 · Cited by 1
Developing biophotonique techniques for the rapid diagnosis of cancer from biofluids.
Hussain, S. R. (2019) · theses.fr (ABES) · doi:10.70675/3d5a49c5z2759z457cz98fdz241c81d1347c
A linear calibration method for scattering semiconductors using the Kubelka-Munk function
Zhao, S., Luo, L., Zhang, F., Jiang, B., Jaroniec, M., & Zhang, L. (2026) · iScience · doi:10.1016/j.isci.2026.117932
Metadata
- Authors
- Filik, J., Frogley, M. D., Pijanka, J. K., Wehbe, K., & Cinque, G.
- Affiliations
- Diamond Light Source (GB)
- Corresponding author
- Frogley, Mark D.
- Venue
- The Analyst
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2012
- Volume
- 137
- Issue
- 4
- Pages
- 853
- ISSN
- 0003-2654 (ISSN-L)
- 1364-5528
- OpenAlex
- W1995206944
- Cited by
- 122
- References
- 34
- Citations by year
- 2026: 2 · 2025: 4 · 2024: 2 · 2023: 1 · 2022: 10 · 2021: 3 · 2020: 12 · 2019: 5 · 2018: 7 · 2017: 8 · 2016: 12 · 2015: 17 · 2014: 11 · 2013: 21 · 2012: 7
- FWCI
- 8.20
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- The Analyst (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Spectroscopy Techniques in Biomedical and Chemical Research
- Physical Sciences › Chemistry › Analytical Chemistry › Spectroscopy and Chemometric Analyses
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Near-Field Optical Microscopy
- Keywords
- sample thickness dependence, optical interference, spectral image analysis
- MeSH terms
- Absorption, Breast Neoplasms, Female, Humans, Scattering, Radiation, Artifacts, Spectroscopy, Fourier Transform Infrared, Cell Line, Tumor
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.